Page 15
EEPROM-8
(With Write Protect switch)
Memory Cassette, 8,000 Steps - EEPROM + Real Time FXClock EEPROM-8C (Same clock specification as FX-RTC, with Write Protect) FX-EPROMMemory Cassette, 8,000 Steps - EPROM 8 FX-RTC
Real Time Clock Cassette (Year/leap year, month, date, day, hour, minute, and second)
FX Programming Tools FX010LDR
FX0/FX0N Prog. Loader (Transfer FX0S/FX0 programs. Can be used with FX Mem. Cass.) JY992D38301 User's Guide (Incl.)
Handheld Programmer, On-line. 2 x 16 LCD. Req. FX20P-CAB FX-10P-E (+ FX-20P-CADP for FX0/FX0S/FX0N) JY992D33401 (Incl.) Handheld Programmer, On/Off-line, 4 x 16 backlit LCD, FX-20P-E Program Storage. JY992D19101 Operation Manual (Included) FX-20PADP-KIT
FX-20P-E Power Adapter (For off-line programming and transfer to/from programming software) JY992D32501 (Incl.)
FX-20PRWM
Write EEPROM/EPROM cassettes with FX-20P-E JY992D25601 User's Guide (Included)
FX-ROM- Adapter - To program EPROM via programming SOC-1 software Programming s/w for all FX Family PLCs, Single User MELMSW- License FX-1 JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.) Programming s/w for all FX Family PLCs, 5 User License MELMSWJY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL FX-5 (Incl.) MELMSW- Programming s/w for all FX Family PLCs, 10 User
Page 16
FX-10
License JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.)
Programming s/w for all FX Family PLCs, 25 User MELMSW- License FX-25 JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.) Programming s/w for all FX Family PLCs, 50 User MELMSW- License FX-50 JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.) SC09
Converter Cable - For use with programming s/w (9 Pin DSUB to 25 Pin DSUB and 25 Pin DSUB to 8 Pin Mini-DIN)
FX-20PCADP
Cable - 25 Pin DSUB to 8 Pin Mini-DIN (Connects SC05-N or FX-20P-CAB to FX0, FX0S or FX0N)
FX-20PCAB
Cable - FX-10DU-E and Programmers to Enhanced FX or FX2C Base Unit
FX Miscellaneous FX-10PSU
Power Supply, 1A @ 24 VDC, 120/240 VAC Powered JY992D37301 User's Guide (Included)
FX-20PSU
Power Supply, 2A @ 24 VDC, 120/240 VAC Powered JY992D37301 User's Guide (Included)
FX-150EC
Cable - 1.5 meter (5' 11") For Extension Unit. JY992D26501 User's Guide (Included)
FX-300EC
Cable - 3.0 meter (9' 10") For Extension Unit. JY992D26501 User's Guide (Included)
FX-60BC
Cable for Extension Block - .6 meter (2' 0") For Extension Block. JY992D26401 User's Guide (Included)
Y451C03201
Terminal Strip - 24 pin, For use on FX-32Mx, 32Ex, 64Mx, 128Mx
Y451C03202
Terminal Strip - 20 pin, For use on FX-16Mx, 24Mx, 64Mx, 128Mx
Page 17
Y451C03203
Terminal Strip - 38 pin, For use on FX-48Mx, 48Ex, 80Mx, 128Mx
FX-RUNSW-E
Run/Stop Switch JY992D50101 User's Guide (Included)
FX-24SW-E
Input Simulation Switch for FX-24Mx JY992D24801 User's Guide (Included)
FX-32SW-E
Input Simulation Switch for FX-32Mx, 32Ex JY992D24801 User's Guide (Included)
FX-48SW-E
Input Simulation Switch for FX-48Mx, 48Ex JY992D24801 User's Guide (Included)
FX-64SW-E
Input Simulation Switch for FX-64Mx, 64Ex JY992D24801 User's Guide (Included)
FX-80SW-E
Input Simulation Switch for FX-80Mx, 80Ex JY992D24801 User's Guide (Included)
FX-DEMO
FX Demo/Training Kit, Base unit with FX-32MTESS/UL, FX-8EYR-ES/UL, simulation switches & displays. Inc. FX-20P-E.
FX-INTROGUIDE
Introductory Guide To Programmable Controllers
FX101APPLIC
One Hundred And One Ways To Use A Programmable Controller
FX-ADVANFX Advanced Manual MANU F2-40BL
Backup battery for Enhanced FX and FX2C PLCs
FX-40CAP
Backup Capacitor (alternative to battery back-up for Enhanced FX and FX2C) JY992D19401 User's Guide (Included)
2 Port Interface (Simultaneous communication FX-2PIF-001 with PLC from both MTA and MEDOC) JY992D44301 (Included)
FX Operator Interfaces FX-10DU-E
2 line x 16 Backlit LCD, Disp. text & PLC data. Req. FX-20P-CAB (+ FX-20P-CADP for FX0,0S & 0N) JY992D54801 (Included)
Page 18
FX-20DU-E
Data Access Unit, Display PLC data JY992D54801 User's Manual (Included)
FX2C Base Units FX2C64MTESS/UL
32 In / 32 Out
FX2C96MTESS/UL
48 In / 48 Out
FX2C128MTESS/UL
64 In / 64 Out
FX2C160MTESS/UL
80 In / 80 Out
FX2C32 In / 32 Out 64MT-E/UL FX2C128MTE/UL
64 In / 64 Out
FX2C-64MT 32 In / 32 Out FX2C-96MT 48 In / 48 Out FX2C128MT
64 In / 64 Out
FX2C160MT
80 In / 80 Out
24 VDC Input (Sink/Source) Transistor Output (Source) Connector I/O Termination 120/240 VAC Power Supply 2,000 step standard memory (Expandable to 8,000 steps) Use with optional Terminal Block I/O JY992D47401 (Included), JY992D48301 (Optional)
24 VDC Input (Sink) Transistor Output (Sink) Other specs. as FX2C-xxMTESS/UL JY992D47401 (Included), JY992D48301 (Optional) 24 VDC Input (Sink) Transistor Output (Sink) Connector I/O Termination 120/240 VAC Power Supply 2,000 step standard memory (Expandable to 8,000 steps) Use with optional Terminal Block I/O JY992D48301 Programming Manual (Optional)
FX2C Terminal Blocks Note: "/UL" type terminal blocks can only be used with "ESS/UL" type base units
Page 19
16 In or 16 Out
Passive Terminal Block (Use as inputs or outputs) JY992D50401 User's Guide (Included)
FX-32E-TB/UL
32 In or 32 Out
Passive Terminal Block (Use as inputs or outputs) JY992D50401 User's Guide (Included)
FX-16EX-A1TB/UL
16 Inputs
120 VAC Input JY992D50401 User's Guide (Included)
FX-16EYR-ESTB/UL
16 Outputs
Relay Output, 2A/point, 8A/4 points JY992D50401 User's Guide (Included)
FX-16EYT-ESSTB/UL
16 Outputs
Transistor Output (Source), 0.5A/pt, 0.8A/4 pts JY992D50401 User's Guide (Included)
FX-16EYT-ESTB/UL
16 Outputs
Transistor Output (Sink), 0.5A/pt, 0.8A/4 pts JY992D50401 User's Guide (Included)
FX-16EYS-ESTB/UL
16 Outputs
Triac Output, 0.3A/point, 0.8A/4 points JY992D50401 User's Guide (Included)
FX-16E-TB/UL
FX2C Terminal Blocks Note: These terminal blocks can only be used with "MT" and "MTE/UL" base units FX-16E-TB
16 In or 16 Out
Passive Terminal Block (Use as inputs or outputs)
FX-16EX-A1-TB
16 Inputs
120 VAC Input
FX-16EYR-TB
16 Outputs
Relay Output, 2A/point, 8A/4 points
FX-16EYT-TB
16 Outputs
Transistor Output (Sink), 0.5A/pt, 0.8A/4 pts
FX-16EYS-TB
16 Outputs
Triac Output, 0.3A/point, 0.8A/4 points
FX2C Cables FX-16E-150CAB-R
FX2C Base Unit to Terminal Block Cable - 1.5 meter (4' 11")
FX-16E-300CAB-R
FX2C Base Unit to Terminal Block Cable - 3.0 meter (9' 10")
FX-16E-500CAB-R
FX2C Base Unit to Terminal Block Cable - 5.0 meter (16' 5")
Page 20
FX-A32E-150CAB
FX2C Base Unit to A-Series (A6TBXY) Terminal Block Cable - 1.5 meter (4' 11")
FX-A32E-300CAB
FX2C Base Unit to A-Series (A6TBXY) Terminal Block Cable - 3.0 meter (9' 10")
FX-A32E-500CAB
FX2C Base Unit to A-Series (A6TBXY) Terminal Block Cable - 5.0 meter (16' 5")
Page 21
Looking for more information? Visit us on the web at http://www.artisan-scientific.com for more information: • Price Quotations • Drivers· Technical Specifications. Manuals and Documentation
Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment • Fast Shipping and DelIve1y • Tens of Thousands of In-Stock Items • Equipment Demos • Hundreds of Manufacturers Supported
• Leasing / Monthly Rentals
• Consignment
Service Center Repairs
InstraView Remote Inspection
Experienced Engineers and Technicians on staff in our State-of-the-art Full-Service In-House Service Center Facility
Remotely inspect equipment before purchasing with our Innovative InstraView-website at http://www.instraview.com
We bUy used equipment! We also offer credit for Buy-Backs and Trade-Ins Sell your excess. underutilized. and idle used equipment. Contact one of our Customer Service Representatives todayl Talk to a live person: 88EM38-S0URCE fB88-887-68721 I Contact us by email: sales@artisan-scientific.com I Visit our website: http://www.artisan-scientific.com