Manual · Mitsubishi
Programmable Controllers FX2n Series: Amazing Performance in a Compact Body
Manual23 pagesPDF 1.6 MB
Product brochure for the Mitsubishi FX2n series programmable controllers: features, expansion, networking, instructions and the model range.
What this file really is
The old site listed this file as a manual for the Mitsubishi FX2-40AW and FX2N-16MR. Linked as an FX2-40AW manual, but it is a sales brochure for the FX2n series controllers that never mentions the FX2-40AW.
Names · 1 model
The models it names
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
A Mitsubishi Electric product brochure for the FX2n series of compact programmable controllers. It describes the features (size, speed, high-speed counters and pulse output), power supply and function cards, memory options, special function blocks for analog, temperature and positioning control, serial communication, networking and open networks (Profibus-DP, CC-Link), programming tools and operator displays, the instruction set, specifications, the model range including the FX2n-16MR, terminal layouts and external dimensions.
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Sales brochure for the Mitsubishi FX2n series of programmable controllers, with its features, model range, options and specifications. It names the FX2N-16MR in its model tables but never mentions the FX2-40AW, which the site also files it under. It lets the reader compare base units, extension units, special function blocks and communication boards.
- FX2N-16MR
- FX2N-16MR: 16 I/O base unit, 8 inputs and 8 relay outputs, AC powered p. 14
- Power supply
- AC base units: 100-240V AC +10%/-15%, 50/60Hz; DC base units: 24V DC +20%, -30% p. 14
- Dimensions
- FX2N-16MR: 87 x 90 x 130 mm p. 14
- Processing speed
- 0.08us per basic instruction; applied instructions 1.52us to several 100us p. 22
- Program memory
- Built-in 8K-step RAM; 16K steps max with RAM, EPROM or EEPROM memory cassettes p. 22
- Inputs
- 24V DC, 7mA on X0 to X7 and 5mA from X10, photocoupler isolated, about 10ms response p. 21
- Relay outputs
- 2A per point resistive, 80VA inductive load, 100W lamp load p. 21
- Sensor service supply
- 24V DC, 460mA, or 250mA on units with 32 I/O or less p. 4, 20
- Instructions
- 27 basic, 2 stepladder and 125 applied instructions p. 22
- Devices
- 256 I/O points in all, 3072 auxiliary relays, 1000 states, 256 timers, 256 counters, 8000 general-purpose data registers p. 22
- Real-time clock
- Built in, year to seconds, valid 1980 to 2079 p. 22
- High-speed counters
- 1-phase: 60kHz on 2 points, 10kHz on 4 points; 2-phase: 30kHz on 1 point, 5kHz on 1 point p. 3
- Communication boards
- FX2n-232-BD (RS-232C), FX2n-422-BD (RS-422, second programming port), FX2n-485-BD (RS-485) p. 4, 7, 8
- Environment
- 0 to 55C operating, -20 to +70C storage, 35 to 85%RH without condensation p. 20
What this manual walks you through
- Instruction set: basic and applied instructions p. 12, 13
- Analog, temperature and positioning special function blocks p. 6
- Serial communication and a second programming port p. 7
- Peer-to-peer and multi-drop networks with the FX2n-485-BD p. 8
- Programming software and hand-held programmers p. 10
- Operator interface and display units p. 11
- Model range of base units, extension units, blocks and boards p. 14, 16, 17, 18, 19
- Sizing the 24V DC service supply when blocks are added p. 20
- Input and output specifications p. 21
Good to know
- Older FX programming tools work with the FX2n but need software upgrades for its newer devices and instructions. p. 3
- Only one optional function expansion card can be used at a time. p. 3
- Older FX peripherals need connection cables to work with the FX2n. p. 4
- Special units and blocks of the earlier FX family need the FX2n-CNV-IF converter cable. p. 3
- Up to 8 special function blocks per base unit, power supply permitting. p. 6
Questions this manual answers
What is the FX2N-16MR?
An FX2n series base unit with 16 I/O: 8 inputs and 8 relay outputs, powered from 100-240V AC. p. 14
How much program memory does the FX2n have?
8K steps of built-in RAM, up to 16K steps with a RAM, EPROM or EEPROM memory cassette. p. 22
Will programs from older FX controllers run on the FX2n?
Yes. The FX2n units are program-compatible with earlier FX Series models. p. 3
How fast is the FX2n?
0.08us per basic instruction; applied instructions take 1.52us to several 100us. p. 22
How many special function blocks can an FX2n base unit take?
Up to 8, power supply permitting. p. 6