The text of a manual · part 1 of 20
I/O Module Type Building Block User's Manual: SAFETY PRECAUTIONS
Pages 1 to 8 of 158, from I/O Module Type Building Block User's Manual
The original document is the PDF (7.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Mitsubishi QG60 and Mitsubishi QX42
Page 1
I/O Module Type Building Block User's Manual QX10 QX10-TS QX28 QX40 QX40-S1 QX40-TS QX40H QX41 QX41-S1 QX41-S2 QX42 QX42-S1 QX50 QX70 QX70H QX71 QX72 QX80 QX80-TS QX80H QX81 QX81-S2 QX82 QX82-S1 QX90H
QY10 QY10-TS QY18A QY22 QY40P QY40P-TS QY41H QY41P QY42P QY50 QY68A QY70 QY71 QY80 QY80-TS QY81P QY82P QH42P QX41Y41P QX48Y57 QI60
Page 2
Page 3
SAFETY PRECAUTIONS (Read these precautions before using this product.) Before using this product, please read this manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product only. For the safety precautions of the programmable controller system, refer to the user’s manual for the CPU module used. In this manual, the safety precautions are classified into two levels: " ! WARNING" and " ! CAUTION".
! WARNING
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
! CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in minor or moderate injury or property damage.
Under some circumstances, failure to observe the precautions given under " ! CAUTION" may lead to serious consequences. Observe the precautions of both levels because they are important for personal and system safety. Make sure that the end users read this manual and then keep the manual in a safe place for future reference.
[Design Precautions] !
WARNING
• Configure safety circuits external to the programmable controller to ensure that the entire system operates safely even when a fault occurs in the external power supply or the programmable controller. Failure to do so may result in an accident due to an incorrect output or malfunction. (1) Configure external safety circuits, such as an emergency stop circuit, protection circuit, and protective interlock circuit for forward/reverse operation or upper/lower limit positioning. (2) When the programmable controller detects an abnormal condition, it stops the operation and all outputs are: (a) Turned off if the overcurrent or overvoltage protection of the power supply module is activated. (b) Held or turned off according to the parameter setting if the self-diagnostic function of the CPU module detects an error such as a watchdog timer error. Note, however, that AnS series modules on the system turn off all outputs in both cases. All outputs may turn on if an error occurs in a part, such as an I/O control part, where the CPU module cannot detect any error. To ensure safety operation in such a case, provide a safety mechanism or a fail-safe circuit external to the programmable controller. For a failsafe circuit example, refer to the user’s manual for the CPU module used. (3) Outputs may remain on or off due to a failure of an output module relay or transistor. Configure an external circuit for monitoring output signals that could cause a serious accident. A-1
A-1
Page 4
[Design Precautions] !
WARNING
• In an output module, when a load current exceeding the rated current or an overcurrent caused by a load short-circuit flows for a long time, it may cause smoke and fire. To prevent this, configure an external safety circuit, such as a fuse. • Configure a circuit so that the programmable controller is turned on first and then the external power supply. If the external power supply is turned on first, an accident may occur due to an incorrect output or malfunction. • For the operating status of each station after a communication failure, refer to relevant manuals for each network. Incorrect output or malfunction due to a communication failure may result in an accident. • When changing data of the running programmable controller from a peripheral connected to the CPU module or from a personal computer connected to an intelligent function module, configure an interlock circuit in the sequence program to ensure that the entire system will always operate safely. For other controls to a running programmable controller (such as program modification or operating status change), read relevant manuals carefully and ensure the safety before the operation. Especially, in the case of a control from an external device to a remote programmable controller, immediate action cannot be taken for a problem on the programmable controller due to a communication failure. To prevent this, configure an interlock circuit in the sequence program, and determine corrective actions to be taken between the external device and CPU module in case of a communication failure.
!
CAUTION
• Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise. • When a device such as a lamp, heater, or solenoid valve is controlled through an output module, a large current (approximately ten times greater than normal) may flow when the output is turned from off to on. Take measures such as replacing the module with one having a sufficient current rating.
A-2
A-2
Page 5
[Installation Precautions] !
CAUTION
• Use the programmable controller in an environment that meets the general specifications in the user’s manual for the CPU module used. Failure to do so may result in electric shock, fire, malfunction, or damage to or deterioration of the product. • To mount the module, while pressing the module mounting lever located in the lower part of the module, fully insert the module fixing projection(s) in the hole(s) in the base unit and press the module until it snaps into place. Incorrect interconnection may cause malfunction, failure, or drop of the module. When using the programmable controller in an environment of frequent vibrations, fix the module with a screw. Tighten the screw within the specified torque range. Undertightening can cause drop of the screw, short circuit or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction. • When using an extension cable, connect it to the extension cable connector of the base unit securely. Check the connection for looseness. Poor contact may cause incorrect input or output. • When using a memory card, fully insert it into the memory card slot. Check that it is inserted completely. Poor contact may cause malfunction. • Shut off the external power supply for the system in all phases before mounting or removing the module. Failure to do so may result in damage to the product. • Do not touch the module during turning on electricity and immediately after power supply interception. There is fear of a burn. • Do not directly touch any conductive parts and electronic components of the module. Doing so can cause malfunction or failure of the module.
[Wiring Precautions] !
WARNING
• Shut off the external power supply for the system in all phases before wiring. Failure to do so may result in electric shock or damage to the product. • After wiring, attach the included terminal cover to the module before turning it on for operation. Failure to do so may result in electric shock.
A-3
A-3
Page 6
[Wiring Precautions] !
CAUTION
• Individually ground the FG and LG terminals of the programmable controller with a ground resistance of 100 Ω or less. Failure to do so may result in electric shock or malfunction. • Check the rated voltage and terminal layout before wiring to the module, and connect the cables correctly. Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure. • Connectors for external devices must be crimped or pressed with the tool specified by the manufacturer, or must be correctly soldered. Incomplete connections may cause short circuit, fire, or malfunction. • Tighten the terminal screw within the specified torque range. Undertightening can cause short circuit, fire, or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction. • Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can cause a fire, failure, or malfunction. • A protective film is attached to the top of the module to prevent foreign matter, such as wire chips, from entering the module during wiring. Do not remove the film during wiring. Remove it for heat dissipation before system operation. • Mitsubishi Electric programmable controllers must be installed in control panels. Connect the main power supply to the power supply module in the control panel through a relay terminal block. Wiring and replacement of a power supply module must be performed by qualified maintenance personnel with knowledge of protection against electric shock. (For wiring methods, refer to the QCPU User's Manual (Hardware Design, Maintenance and Inspection).)
A-4
A-4
Page 7
[Startup and Maintenance Precautions] !
WARNING
• Do not touch any terminal while power is on. Doing so will cause electric shock. • Correctly connect the battery connector. Do not charge, disassemble, heat, short-circuit, or solder the battery, or throw it into the fire. Doing so will cause the battery to produce heat, explode, or ignite, resulting in injury and fire. • Shut off the external power supply for the system in all phases before cleaning the module or retightening the terminal screws or module fixing screws. Failure to do so may result in electric shock. Undertightening the terminal screws can cause short circuit or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction.
A-5
A-5
Page 8
[Startup and Maintenance Precautions] !
CAUTION
• Before performing online operations (especially, program modification, forced output, and operating status change) for the running CPU module from the peripheral device connected, read relevant manuals carefully and ensure the safety. Improper operation may damage machines or cause accidents. • Do not disassemble or modify the modules. Doing so may cause failure, malfunction, injury, or a fire. • Shut off the external power supply for the system in all phases before mounting or removing the module. Failure to do so may cause the module to fail or malfunction. • After the first use of the product, do not mount/remove the module to/from the base unit, and the terminal block to/from the module more than 50 times (IEC 61131-2 compliant) respectively. Exceeding the limit may cause malfunction. • Before handling the module, touch a grounded metal object to discharge the static electricity from the human body. Failure to do so may cause the module to fail or malfunction.
[Disposal Precautions] !
CAUTION
• When disposing of this product, treat it as industrial waste.
A-6
A-6