Manual · Mitsubishi
I/O Module Type Building Block User's Manual
Manual158 pagesPDF 7.3 MB
User's manual for Mitsubishi MELSEC-Q I/O modules: QX input, QY output, combined and interrupt modules, and the QG60 blank cover module.
Covers · 2 models
The models it covers
Summary
What is in it
Mitsubishi Electric user's manual for the MELSEC-Q series building block I/O modules. It gives general specifications and precautions, I/O response time and error-time output settings, and a specification page for each input module (QX10 to QX90H, including the QX42 64-point DC input module), each output module (QY10 to QY82P), the QH42P, QX41Y41P and QX48Y57 combined modules, the QI60 interrupt module and the QG60 blank cover module, plus connectors, terminal block converters, spring clamp terminal blocks, part names, troubleshooting and external dimensions.
Its parts
- General Specifications and Precautions for Use
- Input Module Specifications
- Output Module Specifications
- I/O Combined Module
- Interrupt Module
- Blank Cover Module
- Connectors
- Specifications of Connector/Terminal Block Converter Modules
- Spring Clamp Terminal Block
- Part Names
- I/O Module Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
Mitsubishi user's manual for the MELSEC-Q building block I/O modules: the QX input and QY output modules, the QH42P, QX41Y41P and QX48Y57 combined modules, the QI60 interrupt module and the QG60 blank cover module. It gives each module's specifications plus connectors, terminal block converters, part names, troubleshooting and external dimensions.
- QG60 use
- QG60: blank cover module, a dustproof cover for an empty base unit slot, especially one between I/O modules p. 108
- QG60 size
- QG60: H 98 mm, W 27.4 mm, D 90 mm p. 108
- QG60 I/O points
- QG60: 16 points by default; can be set to 0, 16, 32, 48, 64, 128, 256, 512 or 1024 in the PLC parameter p. 108
- QX42 type
- QX42: 64-point DC input module, positive common type, photocoupler isolated p. 53
- QX42 input voltage
- QX42: 24VDC (+20/-15%, ripple ratio within 5%) p. 53
- QX42 connectors
- QX42: 40-pin connectors, left and right; mating A6CON1, A6CON2, A6CON3 or A6CON4 (optional) p. 53, 54
- QX42 commons
- QX42: 32 points per common, common terminals 1B01, 1B02, 2B01, 2B02 p. 53
- QX42 indicators
- QX42: ON indication LEDs, switched between the first and latter 32 points with a selector switch p. 53, 54
- QX42 response time
- QX42: 1, 5, 10, 20 or 70 ms, set in the PLC parameter (default 10 ms) p. 53
- QX42 terminal blocks
- QX42: A6TBXY36, A6TBXY54 or A6TBX70 converter modules; 64-point modules need two converters and two cables p. 53, 113
- AnS connectors
- A 40-pin connector from a MELSEC-AnS I/O module can be used as is on MELSEC-Q I/O modules p. 153
What this manual walks you through
- QX42 specifications and connector pin-outs p. 53, 54
- Choosing user-prepared 40-pin and 37-pin D-sub connectors and tools p. 110, 111
- Using connector/terminal block converter modules and cables p. 112, 113
- Troubleshooting input signals that do not turn off or pick up noise p. 134, 135, 136
- Troubleshooting output circuits p. 137, 138, 139, 140, 141
- Identifying the parts of an I/O module p. 128, 129, 130, 131
- Setting the input response time against noise p. 19
- External dimensions of I/O modules and the blank cover module p. 142, 143, 144, 145
- Replacing MELSEC-AnS I/O modules with MELSEC-Q modules p. 152, 153
Good to know
- Fit the QG60 with the base unit's connector cover in place. p. 108
- Operate the QX42 indication selector switch with a fingertip, not a screwdriver. p. 128
- On a DC input module, put a diode in parallel with any inductive load. p. 20
- How many inputs may be on at once depends on input voltage and ambient temperature. p. 19
- The conventional A6TB cable for a MELSEC-AnS 37-pin D-sub connector cannot be used on MELSEC-Q modules. p. 153
Questions this manual answers
What is the Mitsubishi QG60?
It is the MELSEC-Q blank cover module, a dustproof cover for an empty slot on the base unit, measuring 98 x 27.4 x 90 mm. p. 108
How many inputs does the QX42 have?
The QX42 is a 64-point, 24VDC, positive common DC input module. p. 53
What connector does the QX42 need?
It takes user-prepared 40-pin connectors: A6CON1, A6CON2, A6CON3 or A6CON4. p. 53, 110
Can the QX42 be wired to a screw terminal block?
Yes, through A6TBXY36, A6TBXY54 or A6TBX70 converter modules; a 64-point module needs two converters and two cables. p. 53, 113
How do I see the LEDs for inputs X20 to X3F on a QX42?
Set the indication selector switch to the right-hand (L) side to show the latter half, X20 to X3F. p. 54
Contents
Chapters and sections
Each line opens the PDF at its page.
- SAFETY PRECAUTIONS3
- CONDITIONS OF USE FOR THE PRODUCT9
- REVISIONS10
- INTRODUCTION14
- ABOUT MANUALS17
- COMPLIANCE WITH EMC AND LOW VOLTAGE DIRECTIVES17
- 1. GENERAL SPECIFICATIONS AND PRECAUTIONS FOR USE19
- 2. INPUT MODULE SPECIFICATIONS41
- 2.1 QX10 AC Input Module41
- 2.2 QX10-TS AC Input Module42
- 2.3 QX28 AC Input Module43
- 2.4 QX40 DC Input Module (Positive Common Type)44
- 2.5 QX40-S1 DC Input Module (Positive Common Type)45
- 2.6 QX40-TS DC Input Module (Positive Common Type)46
- 2.7 QX40H DC High-Speed Input Module (Positive Common Type)47
- 2.8 QX41 DC Input Module (Positive Common Type)49
- 2.9 QX41-S1 DC Input Module (Positive Common Type)50
- 2.10 QX41-S2 DC Input Module (Positive Common Type)52
- 2.11 QX42 DC Input Module (Positive Common Type)53
- 2.12 QX42-S1 DC Input Module (Positive Common Type)55
- 2.13 QX50 DC (Positive Common/Negative Common Shared Type)/ AC Input Module57
- 2.14 QX70 DC Input Module (Positive Common/Negative Common Shared Type)58
- 2.15 QX70H DC High-speed Input Module (Positive Common Type)59
- 2.16 QX71 DC Input Module (Positive/Negative Shared Common Type)61
- 2.17 QX72 DC Input Module (Positive/Negative Shared Common Type)62
- 2.18 QX80 DC Input Module (Negative Common Type)64
- 2.19 QX80-TS DC Input Module (Negative Common Type)65
- 2.20 QX80H DC High-speed Input Module (Negative Common Type)66
- 2.21 QX81 DC Input Module (Negative Common Type)68
- 2.22 QX81-S2 DC Input Module (Negative Common Type)69
- 2.23 QX82 DC Input Module (Negative Common Type)70
- 2.24 QX82-S1 DC Input Module (Negative Common Type)72
- 2.25 QX90H DC High-speed Input Module (Negative Common Type)74
- 3. OUTPUT MODULE SPECIFICATIONS77
37 more lines, from page 79 on
- 3.3 QY18A Contact Output Module (All Points Independent)79
- 3.4 QY22 TRIAC Output Module80
- 3.5 QY40P Transistor Output Module (Sink Type)82
- 3.6 QY40P-TS Transistor Output Module (Sink Type)83
- 3.7 QY41H Transistor High-speed Output Module (Sink Type)84
- 3.8 QY41P Transistor Output Module (Sink Type)85
- 3.9 QY42P Transistor Output Module (Sink Type)86
- 3.10 QY50 Transistor Output Module (Sink Type)87
- 3.11 QY68A Transistor Output Module (All Points Independent, Sink/Source Type)88
- 3.12 QY70 Transistor Output Module (Sink Type)89
- 3.13 QY71 Transistor Output Module (Sink Type)90
- 3.14 QY80 Transistor Output Module (Source Type)91
- 3.15 QY80-TS Transistor Output Module (Source Type)92
- 3.16 QY81P Transistor Output Module (Source Type)94
- 3.17 QY82P Transistor Output Module (Source Type)95
- 4. I/O COMBINED MODULE97
- 5. INTERRUPT MODULE106
- 6. BLANK COVER MODULE108
- 7. CONNECTORS110
- 8. SPECIFICATIONS OF CONNECTOR/TERMINAL BLOCK CONVERTER MODULES112
- 9. SPRING CLAMP TERMINAL BLOCK119
- 10. PART NAMES128
- 11. I/O MODULE TROUBLESHOOTING134
- APPENDICES142
- WARRANTY155
The whole text · 20 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- SAFETY PRECAUTIONS1-8
- Pages 9 to 139-13
- INTRODUCTION14-16
- Pages 17 to 2417-24
- Pages 25 to 3225-32
- Pages 33 to 4033-40
- 2. INPUT MODULE SPECIFICATIONS, pages 41 to 4941-49
- 2. INPUT MODULE SPECIFICATIONS, pages 50 to 5850-58
- 2. INPUT MODULE SPECIFICATIONS, pages 59 to 6759-67
- 2. INPUT MODULE SPECIFICATIONS, pages 68 to 7668-76
- 3. OUTPUT MODULE SPECIFICATIONS, pages 77 to 8677-86
- 3. OUTPUT MODULE SPECIFICATIONS, pages 87 to 9687-96
- 4. I/O COMBINED MODULE97-105
- Pages 106 to 109106-109
- Pages 110 to 118110-118
- 9. SPRING CLAMP TERMINAL BLOCK119-127
- 10. PART NAMES128-133
- 11. I/O MODULE TROUBLESHOOTING134-141
- APPENDICES142-154
- WARRANTY155-158
The file