Page 68
2 INPUT MODULE SPECIFICATIONS
MELSEC-Q
2.21 QX81 DC Input Module (Negative Common Type) Type Specifications
QX81 32 points Photocoupler 24VDC (+20/-15%, ripple ratio within 5%) Approx. 4mA Refer to the derating chart. 19V or higher/3mA or higher 11V or lower/1.7mA or lower Approx. 5.6kΩ 1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter) 1 (Default: 10ms) 1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter) 1 (Default: 10ms) 560VAC rms/3 cycles (altitude 2000m) 10MΩ or more by insulation resistance tester By noise simulator of 500Vp-p noise voltage, 1 s noise width and 25 to 60Hz noise frequency First transient noise IEC61000-4-4: 1kV IP2X 32 points/common (common terminal: 17, 18, 36) 32 points (I/O assignment is set as a 32-point input module.) ON indication (LED) 37-pin D-sub connector 0.088 to 0.3mm2 (For A6CON1E) 2
Number of input points Isolation method Rated input voltage Rated input current Input derating ON voltage/ON current OFF voltage/OFF current Input impedance Response time
DC input module (Negative common type)
OFF to ON ON to OFF
Dielectric withstand voltage Insulation resistance Noise immunity Protection degree Common terminal arrangement Number of occupied I/O points Operation indicator External connections Applicable wire size Applicable connector Applicable connector/terminal block converter module Internal current consumption (5VDC) Weight
QX81 0 1 2 3 4 5 6 7 8 9 A B CDEF 0 1 2 3 4 5 6 7 8 9 A B CDEF QX81 24VDC 4mA
A6CON1E, A6CON2E, A6CON3E (optional) A6TBX36-E, A6TBX54-E, A6TBX70-E 75mA (TYP. all points ON) (0.08A is shown on the rating plate of the module.) 0.16kg
Derating chart (%) 100 90 ON 80 ratio 70 60 50 40 0
Appearance
Pin No.
Pin-Outs
28.8VDC
10 20 30 40 50 55 ( C ) Ambient temperature
External connection
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
Module front view
Signal No.
Pin No.
Signal No.
1
X00
9
X10
20
X01
28
X11
2
X02
10
X12
21
X03
29
X13
3
X04
11
X14
22
X05
30
X15
4
X06
12
X16
23
X07
31
X17
5
X08
13
X18
24
X09
32
X19
6
X0A
14
X1A
25
X0B
33
X1B
7
X0C
15
X1C
26
X0D
34
X1D
8
X0E
16
X1E
27
X0F
35
X1F
17
COM
37
Vacant
36
COM
19
Vacant
18
COM
1: For the setting method, refer to Section 1.3.1. 2: When using A6CON2E or A6CON3E, refer to Chapter 7.
2 - 28
2 - 28
Page 69
2 INPUT MODULE SPECIFICATIONS
MELSEC-Q
2.22 QX81-S2 DC Input Module (Negative Common Type) Type Specifications
QX81-S2 32 points Photocoupler 24VDC (+20/-15%, ripple ratio within 5%) Approx. 6mA Refer to the derating chart. 15V or higher/3mA or higher 5V or lower/1.7mA or lower Approx. 3.6kΩ 1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter) 1 (Default: 10ms) 1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter) 1 (Default: 10ms) 560VAC rms/3 cycles (altitude 2000m) 10MΩ or more by insulation resistance tester By noise simulator of 500Vp-p noise voltage, 1 s noise width and 25 to 60Hz noise frequency First transient noise IEC61000-4-4: 1kV IP2X 32 points/common (common terminal: 17, 18, 36) 32 points (I/O assignment is set as a 32-point input module.) ON indication (LED) 37-pin D-sub connector 0.088 to 0.3mm2 (For A6CON1E) 2
Number of input points Isolation method Rated input voltage Rated input current Input derating ON voltage/ON current OFF voltage/OFF current Input impedance Response time
DC input module (Negative common type)
OFF to ON ON to OFF
Dielectric withstand voltage Insulation resistance Noise immunity Protection degree Common terminal arrangement Number of occupied I/O points Operation indicator External connections Applicable wire size Applicable connector Applicable connector/terminal block converter module Internal current consumption (5VDC) Weight
A6CON1E, A6CON2E, A6CON3E (optional) A6TBX36-E, A6TBX54-E, A6TBX70-E 75mA (TYP. all points ON) (0.08A is shown on the rating plate of the module.) 0.16kg
Derating chart (%) 100 90 80 70 ON ratio 60 50 40 30 20 10 0
Pin No.
Pin-Outs
(31.25%) 24VDC (18.75%) 28.8VDC
10 20 30 40 Ambient temperature
Appearance
50 55 (
)
External connection
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
Module front view
Signal No.
Pin No.
Signal No.
1
X00
9
X10
20
X01
28
X11
2
X02
10
X12
21
X03
29
X13
3
X04
11
X14
22
X05
30
X15
4
X06
12
X16
23
X07
31
X17
5
X08
13
X18
24
X09
32
X19
6
X0A
14
X1A
25
X0B
33
X1B
7
X0C
15
X1C
26
X0D
34
X1D
8
X0E
16
X1E
27
X0F
35
X1F
17
COM
37
Vacant
36
COM
19
Vacant
18
COM
1: For the setting method, refer to Section 1.3.1. 2: When using A6CON2E or A6CON3E, refer to Chapter 7.
2 - 29
2 - 29
Page 70
2 INPUT MODULE SPECIFICATIONS
MELSEC-Q
2.23 QX82 DC Input Module (Negative Common Type) Type Specifications Number of input points Isolation method Rated input voltage Rated input current Input derating ON voltage/ON current OFF voltage/OFF current Input impedance Response time
OFF to ON ON to OFF
Dielectric withstand voltage Insulation resistance Noise immunity Protection degree Common terminal arrangement Number of occupied I/O points Operation indicator External connections Applicable wire size Applicable connector Applicable connector/terminal block converter module Internal current consumption (5VDC) Weight
DC input module (Negative common type) QX82 64 points Photocoupler 24VDC (+20/-15%, ripple ratio within 5%) Approx. 4mA Refer to the derating chart. 19V or higher/3mA or higher 11V or lower/1.7mA or lower Approx. 5.6kΩ 1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter) 1 (Default: 10ms) 1ms/5ms/10ms/20ms/70ms or less (configured in PLC parameter) 1 (Default: 10ms) 560VAC rms/3 cycles (altitude 2000m) 10MΩ or more by insulation resistance tester By noise simulator of 500Vp-p noise voltage, 1 s noise width and 25 to 60Hz noise frequency First transient noise IEC61000-4-4: 1kV IP2X 32 points/common (common terminal: 1B01, 1B02, 2B01, 2B02) 64 points (I/O assignment is set as a 64-point input module.) ON indication (LED), 32 point switch-over using switch 40-pin connector 0.088 to 0.3mm2 (For A6CON1 or A6CON4) 2 A6CON1, A6CON2, A6CON3, A6CON4 (optional)
Appearance
QX82 0 1 2 3 4 5 6 7 8 9 A B CDE F 0 1 2 3 4 5 6 7 8 9 A B CDE F 24VDC 4mA
F
QX82 DISPLAY L, - - - - 90mA (TYP. all points ON) 0.18kg
1: For the setting method, refer to Section 1.3.1. 2: When using A6CON2 or A6CON3, refer to Chapter 7.
2 - 30
2 - 30
Page 71
2 INPUT MODULE SPECIFICATIONS
Derating chart (%) 100 90 80 70 ON ratio/ 60 common 50 40 30 20 0
MELSEC-Q Pin Pin Pin Pin Signal Signal Signal No. Signal No. No. No. No. No. No. No. 4 4 4 4
Pin-Outs
24VDC 26.4VDC 28.8VDC
10 20 30 40 50 55 ( C ) Ambient temperature
External connection
B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1
A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1
Module front view
1B20
X00
1A20
X10
2B20
X20
2A20
X30
1B19
X01
1A19
X11
2B19
X21
2A19
X31
1B18
X02
1A18
X12
2B18
X22
2A18
X32
1B17
X03
1A17
X13
2B17
X23
2A17
X33
1B16
X04
1A16
X14
2B16
X24
2A16
X34
1B15
X05
1A15
X15
2B15
X25
2A15
X35
1B14
X06
1A14
X16
2B14
X26
2A14
X36
1B13
X07
1A13
X17
2B13
X27
2A13
X37
1B12
X08
1A12
X18
2B12
X28
2A12
X38
1B11
X09
1A11
X19
2B11
X29
2A11
X39
1B10
X0A
1A10
X1A
2B10
X2A
2A10
X3A
1B09
X0B
1A09
X1B
2B09
X2B
2A09
X3B
1B08
X0C
1A08
X1C
2B08
X2C
2A08
X3C
1B07
X0D
1A07
X1D
2B07
X2D
2A07
X3D
1B06
X0E
1A06
X1E
2B06
X2E
2A06
X3E
1B05
X0F
1A05
X1F
2B05
X2F
2A05
X3F
1B04 Vacant 1A04 Vacant 2B04 Vacant 2A04 Vacant 1B03 Vacant 1A03 Vacant 2B03 Vacant 2A03 Vacant 1B02 COM1 1A02 Vacant 2B02 COM2 2A02 Vacant
The above diagram shows the first half of 32 points (F). The latter half of 32 points (L) are similar.
1B01 COM1 1A01 Vacant 2B01 COM2 2A01 Vacant
3: Selection of left-hand (F) side provides the first half (X00 to X1F) LED indications, and selection of right-hand (L) side provides the latter half (X20 to X3F) LED indications. 4: Pin number of 1 indicates that of the left-hand side connector, and pin number of 2 indicates that of the right-hand side connector.
2 - 31
2 - 31
Page 72
2 INPUT MODULE SPECIFICATIONS
MELSEC-Q
2.24 QX82-S1 DC Input Module (Negative Common Type) Type Specifications Number of input points Isolation method Rated input voltage Rated input current Input derating ON voltage/ON current OFF voltage/OFF current Input impedance Set value 1 TYP. Response OFF to ON MAX. time TYP. ON to OFF MAX. Dielectric withstand voltage Insulation resistance Noise immunity Protection degree Common terminal arrangement Number of occupied I/O points Operation indicator External connections Applicable wire size Applicable connector Applicable connector/terminal block converter module Internal current consumption (5VDC) Weight
DC input module (Negative common type) QX82-S1 64 points Photocoupler 24VDC (+20/-15%, ripple ratio within 5%) Approx. 4mA Refer to the derating chart. 19V or higher/3.0mA or higher 9.5V or lower/1.5mA or lower Approx. 5.6kΩ 0.1 0.2 0.4 0.6 1 0.05ms 0.15ms 0.30ms 0.55ms 1.05ms 0.12ms 0.20ms 0.40ms 0.60ms 1.20ms 0.15ms 0.20ms 0.35ms 0.60ms 1.10ms 0.20ms 0.30ms 0.50ms 0.70ms 1.30ms 560VAC rms/3 cycles (altitude 2000m) 10MΩ or more by insulation resistance tester By noise simulator of 500Vp-p noise voltage, 1 s noise width and 25 to 60Hz noise frequency First transient noise IEC61000-4-4: 1kV IP2X 32 points/common (common terminal: 1B01, 1B02, 2B01, 2B02) 64 points (I/O assignment is set as a 64-point high-speed input module.) ON indication (LED), 32 point switch-over using switch 40-pin connector 0.088 to 0.3mm2 (For A6CON1 or A6CON4) 2 A6CON1, A6CON2, A6CON3, A6CON4 (optional)
Appearance
QX82-S1 0 1 2 3 4 5 6 7 8 9 A B CDE F 0 1 2 3 4 5 6 7 8 9 A B CDE F 24VDC 4mA
F
QX82-S1 DISPLAY L, - - - - 90mA (TYP. all points ON) 0.18kg
1: Configured in PLC parameter. (Default: 0.2ms) A response time setting value can be changed in GX Developer (SW5D5C-GPPW or later). For the setting method, refer to Section 1.3.1. 2: When using A6CON2 or A6CON3, refer to Chapter 7.
2 - 32
2 - 32
Page 73
2 INPUT MODULE SPECIFICATIONS
Derating chart (%) 100 90 80 ON ratio/ 70 common 60 50 40 30 20 0
Pin Pin Pin Pin Signal Signal Signal Signal No. No. No. No. No. No. No. No. 4 4 4 4
Pin-Outs
24VDC 26.4VDC 28.8VDC
10 20 30 40 50 55 ( C ) Ambient temperature
External connection
MELSEC-Q
B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1
A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1
Module front view
1B20
X00
1A20
X10
2B20
X20
2A20
X30
1B19
X01
1A19
X11
2B19
X21
2A19
X31
1B18
X02
1A18
X12
2B18
X22
2A18
X32
1B17
X03
1A17
X13
2B17
X23
2A17
X33
1B16
X04
1A16
X14
2B16
X24
2A16
X34
1B15
X05
1A15
X15
2B15
X25
2A15
X35
1B14
X06
1A14
X16
2B14
X26
2A14
X36
1B13
X07
1A13
X17
2B13
X27
2A13
X37
1B12
X08
1A12
X18
2B12
X28
2A12
X38
1B11
X09
1A11
X19
2B11
X29
2A11
X39
1B10
X0A
1A10
X1A
2B10
X2A
2A10
X3A
1B09
X0B
1A09
X1B
2B09
X2B
2A09
X3B
1B08
X0C
1A08
X1C
2B08
X2C
2A08
X3C
1B07
X0D
1A07
X1D
2B07
X2D
2A07
X3D
1B06
X0E
1A06
X1E
2B06
X2E
2A06
X3E
1B05
X0F
1A05
X1F
2B05
X2F
2A05
X3F
1B04 Vacant 1A04 Vacant 2B04 Vacant 2A04 Vacant 1B03 Vacant 1A03 Vacant 2B03 Vacant 2A03 Vacant 1B02 COM1 1A02 Vacant 2B02 COM2 2A02 Vacant 1B01 COM1 1A01 Vacant 2B01 COM2 2A01 Vacant
The above diagram shows the first half of 32 points (F). The latter half of 32 points (L) are similar. 3: Selection of left-hand (F) side provides the first half (X00 to X1F) LED indications, and selection of right-hand (L) side provides the latter half (X20 to X3F) LED indications. 4: Pin number of 1 indicates that of the left-hand side connector, and pin number of 2 indicates that of the right-hand side connector.
2 - 33
2 - 33
Page 74
2 INPUT MODULE SPECIFICATIONS
MELSEC-Q
2.25 QX90H DC High-speed Input Module (Negative Common Type) DC high-speed input module (Negative common type)
Type Specifications
QX90H
Appearance
Number of input points Isolation method Rated input voltage Rated input current Input derating
16 points Photocoupler 5VDC (+20/-15%, ripple ratio within 5%) Approx. 6mA None
ON voltage/ON current OFF voltage/OFF current Input impedance SW1 (noise filter) 1 Set value 2 Response TYP. time OFF to ON MAX. TYP. ON to OFF MAX. Function SW2 4 setting Dielectric withstand voltage Insulation resistance
3.5V or higher/3mA or higher 1V or lower/1mA or lower Approx. 470Ω
Noise immunity
5
Protection degree Common terminal arrangement Number of occupied I/O points Interrupt processing condition Operation indicator External connections Applicable wire size Applicable crimping terminal Internal current consumption (5VDC) Weight
OFF
ON
Invalid 0ms 0ms -
3 3 3 3
0.1 0.04ms 0.05ms 0.04ms 0.05ms
0.2 0.10ms 0.15ms 0.10ms 0.15ms
0.4 0.25ms 0.30ms 0.25ms 0.30ms
0.6 0.50ms 0.60ms 0.50ms 0.60ms
1 0.95ms 1.00ms 0.95ms 1.00ms
OFF: Interrupt, ON: High-speed input 560VAC rms/3 cycles (altitude 2000m) 10MΩ or more by insulation resistance tester By noise simulator of 500Vp-p noise voltage, 1 s noise width and 25 to 60Hz noise frequency IP2X 8 points/common (common terminal: TB9, TB18) 16 points (I/O assignment is set as a 16-point high-speed input module or 16point interrupt module.) 4 Set by Switch setting in GX Developer 4 6 ON indication (LED) 18-point terminal block (M3 6 screws) 0.3 to 0.75mm2 core (2.8mm OD max.) R1.25-3 (Sleeved crimping terminals cannot be used.) 80mA (TYP. all points ON) 0.14kg
1: If the noise filter selector switch (switch 1) on the bottom of the module (refer to Chapter 10) is turned on, the noise filter takes effect. The off-status noise filter disables I/O response time setting. After switching on or off the switch 1, reset the power supply of the CPU module. 2: Set an input response time in "I/O response time" combo box of PLC parameter in GX Developer. (Default: 0.2ms) A response time setting value can be changed in GX Developer (SW6D5C-GPPW or later). For the setting details, refer to Section 1.3.1. 3: The actual response time is 5 s delay when turning on, 10 s delay when turning off, because the hardware response time is added. For the details of the CPU overhead time, refer to manuals for the CPU module used (Function Explanation, Program Fundamentals). 4: The module function can be changed according to the status of the function selector switch (switch 2) on the bottom of the module (refer to Chapter 10). ON: High-speed input OFF: Interrupt If the function selector switch (switch 2) setting is changed while the CPU module is in RUN, an error (error code: 2100) occurs. 5: Indicates the noise immunity when the noise filter takes effect (the noise filter selector switch (switch 1) is turned on). 6: For the setting method, refer to Section 1.3.3.
2 - 34
2 - 34
Page 75
2 INPUT MODULE SPECIFICATIONS
External connection
2 - 35
MELSEC-Q Terminal block No.
Signal name
TB1
X00
TB2
X01
TB3
X02
TB4
X03
TB5
X04
TB6
X05
TB7
X06
TB8
X07
TB9
COM1
TB10
X08
TB11
X09
TB12
X0A
TB13
X0B
TB14
X0C
TB15
X0D
TB16
X0E
TB17
X0F
TB18
COM2
2 - 35
Page 76
2 INPUT MODULE SPECIFICATIONS
MELSEC-Q
MEMO
2 - 36
2 - 36