Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 14 of 20

I/O Module Type Building Block User's Manual, pages 106 to 109

Pages 106 to 109 of 158: 5. INTERRUPT MODULE; 6. BLANK COVER MODULE

The original document is the PDF (7.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Mitsubishi QG60 and Mitsubishi QX42

Page 106

5 INTERRUPT MODULE

MELSEC-Q

5. INTERRUPT MODULE 5.1 QI60 Interrupt Module For usage of this module, refer to the User’s Manual (Function Explanation, Program Fundamentals) for the CPU module used. Type Specifications Number of input points Isolation method Rated input voltage Rated input current Input derating ON voltage/ON current OFF voltage/OFF current Input impedance Set value 1 TYP. Response OFF to ON MAX. time TYP. ON to OFF MAX. Dielectric withstand voltage Insulation resistance

5

Noise immunity Protection degree Common terminal arrangement Number of occupied I/O points Interrupt processing condition Operation indicator External connections Applicable wire size Applicable crimping terminal Internal current consumption (5VDC) Weight

Interrupt module QI60 16 points Photocoupler 24VDC (+20/-15%, ripple ratio within 5%) Approx. 6mA No 19V or higher/4.0mA or higher 11V or lower/1.7mA or lower Approx. 3.9kΩ 0.1 0.2 0.4 0.6 1 0.05ms 0.15ms 0.30ms 0.55ms 1.05ms 0.10ms 0.20ms 0.40ms 0.60ms 1.20ms 0.15ms 0.20ms 0.35ms 0.60ms 1.10ms 0.20ms 0.30ms 0.50ms 0.70ms 1.30ms 560VAC rms/3 cycles (altitude 2000m) 10MΩ or more by insulation resistance tester By noise simulator of 500Vp-p noise voltage, 1 s noise width and 25 to 60Hz noise frequency First transient noise IEC61000-4-4: 1kV IP2X 16 points/common (common terminal: TB17) 16 points (I/O assignment is set as a 16-point interrupt module.) 3 Set by Switch setting in GX Developer. 2 ON indication (LED) 18-point terminal block (M3 6 screws) 0.3 to 0.75mm2 core (2.8mm OD max.) R1.25-3 (Sleeved crimping terminals cannot be used.) 60mA (TYP. all points ON) 0.20kg

External connection

Terminal block No. TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18

Appearance

QI60 0 1 2 3 4 5 6 7 8 9 A B CDE F

0 1 2 3 4 5 6 7 8 9 A B C D E F - +

COM

NC 24VDC 6mA

0 1 2 3 4 5 6 7 8 9 A B C D E F

Signal name X00 X01 X02 X03 X04 X05 X06 X07 X08 X09 X0A X0B X0C X0D X0E X0F COM Vacant

1: Select the value in PLC parameter. (Default: 0.2ms). Refer to Section 1.3.1 for the setting method. For the CPU modules (Q series) and GX Developer where the response time can be set, refer to Section 1.2.5. 2: For the setting method, refer to the section 1.3.3. 3: When making settings with an SW5D5C-GPPW or earlier GX Developer, select "16 point intelligent Module."

5-1

5-1

Page 107

5 INTERRUPT MODULE

MELSEC-Q

MEMO

5

5-2

5-2

Page 108

6 BLANK COVER MODULE

MELSEC-Q

6. BLANK COVER MODULE This chapter provides the specifications of the blank cover module used to protect the vacant slot (between I/O modules) of the base unit from dust. Table 6.1 Blank Cover Module Specifications Type Item Number of occupied I/O points dimensions Weight

Default: 16 points (Can be changed to 0, 16, 32, 48, 64, 128, 256, 512, 1024 points by "PLC system" of "PLC parameter".) Used as a dustproof cover for a slot not loaded with an I/O module

Application External

QG60

(especially a vacant slot between modules). H

98mm

W

27.4mm

D

90mm 0.07 kg

Load the blank cover module with the connector cover of the base unit fitted.