The text of a manual · part 14 of 21
CNC Systems OSP-U100M, OSP-U10M, MX-V Series Maintenance Manual, pages 131 to 140
Pages 131 to 140 of 208
The original document is the PDF (22 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Okuma FUB-DR3
Page 131
4194-E P-120 SECTION 6 PLC MONITOR FUNCTION
[AUTO OPERATION SEIGYO. MIN OSHT1_N 0] 97/07/15 14:10:00 LADDER MODULE =SPINDLE NO.=! ! a | f 7 AéoY VASOFPL RSTCM ! | PB-RST, | aST |, - ( ) RSTFN RINADY VASOFPL rH - - [ SCODE LMOV_ - ERIDSHE j - SSTB Vv Vv CNNT:Spindle run ready | MODULE | PAGE
[F1 J(F2 |(F3)(F4)(F5)(F6)(F7)(F8)
Fig. 6-4 Screen Displaying Labels
\ cau SELECT | LABEL | SEARCH | ROLL t
[SEARCH] Searches for the specified identifier or label in the ladder diagram.
< Procedure > 1) Press function key [F4] (SEARCH).
2) Input an identifier or a label.
lf necessary, input an option continuously.
3) Press the WRITE key.
The circuit block found first is displayed at the middle in the screen with the cursor on it.
[Supplement] When specifying an identifier, zeros in the higher-digit address can be omitted.!.000F = |.0F When specifying a label, it is not allowed to use a wild card.
Following option designation is possible. Designation of more than options is allowed. The delimiter used between the data and the option is a semicolon “:” and a space must not be entered between the data and the delimiter. If more than one option should be specified, enter a space between options or specify them continuously.
Example: xox:RA XXxx;]RA - Option ;R Search only for contacts.
(default: search for both contacts and coils)
Page 132
- - - 4194-E P-124 SECTION 6 PLC MONITOR FUNCTION
- Option ;W Search only for coils. - Option ;A Search in all programs 1) Inthe ascending order of program numbers 2) In the ascending order of page numbers 3) Inthe ascending order of step numbers - Option ;P Search in the specified program (default) - Option ;C Search for cursor symbol
(If search option for a symbol is specified at the same time, option ;C is given priority.)
(c) Search menu
1)
3)
If you press the WRITE key without inputting anything after pressing the function key, the interactive input mode is set and a message is displayed in the console line. At the same time, search menu items for option designation are displayed at the function keys.
> Input the search symbol!
Pressing the WRITE key after inputting an identifier or a label, the search target symbol is established.
If the WRITE key is pressed without inputting anything, the following message is displayed. > Search for the symbol’s cursor position (Y/N)!
“Y" + [WRITE]: The identifier or label at the cursor position is established as the search target symbol.
“N" + [WRITE]: The screen returns to the input step for an identifier or a label.
If there is no symbol at the cursor position, the following message is displayed. > Symbol not at cursor position. Press WRITE key!
lf you press the WRITE key, search is stopped.
While the search target symbol is not established, only function key [F7] (QUIT) is accepted and other keys are not operative.
When the search target symbol is established, the following message is displayed.
> -kok2k will be searched. Specify the options.
| Identifier or label
To specify an option, press the function keys corresponding to the required options. The message changes according to the designated options,
If the function key of the designated option is pressed again, option designation is canceled.
> 3222 | 22? will be searched. Specify the options.
|, Option Identifier or label
Page 133
4194-E P-122 SECTION 6 PLC MONITOR FUNCTION
- Search menu function
SRCH SEARCH | MODULE | START | CANCEL |
(FU(F2 CFs (FFs) Fe)
[F1] (CONTACT SRCH) Search only for contacts. [F2] (COIL SEARCH) Search only for coils. [F3] (ALL MODULE)
Search in all programs.
CONTACT ie pe. |
4) Press function key [F6] (START) to start search. The circuit block found first is displayed at the middle in the screen with the cursor on it.
If more than one circuit blocks are found, the first one is displayed in the screen and then the following message is displayed.
> Continue searching (Y/N)! “Y" + [WRITE]: The next circuit block is displayed.
“N" + [WRITE]: Search is canceled. Menu returns from the search menu to the function menu.
If you press function key [F7] (CANCEL), the following message is displayed. > Cancel searching (Y/N)!
“Y" + [WRITE]: Search is canceled. Menu returns from the search menu to the function menu.
“N" + [WRITE]: Search is continued. [ROLL t]: Returns the display position within the displayed page. [ROLL |]: Advances the display position within the displayed page.
[Supplement] [ROLL t] and [ROLL J]
1) lf“comment OFF”, display position moves by 8 elements (16 lines) at atime.
2) If*comment ON”, display position moves by 4 elements (16 lines) ata time.
Page 134
4194-E P-123 SECTION 6 PLC MONITOR FUNCTION lf a circuit block is continuous in two or more lines, the symbols shown below are displayed at the left end of the circuit block.
Continuous: upstream and downstream Al Vi \ a Continuous: downstream | | | \ Al Vv | Continuous: upstream Al A | | | | Not continuous | | | | [QUIT] Returns the menu to the PLC monitor function menu. [EXTEND] Calls function 2. (d) Function 2 WO | pant i | | ON ON/OFF | ON/OFF QUIT |[EXTEND] {r \ (F1 )(F2 j(F3 |(F4 |(F5 |(F6 |(F7 JL F8 }
[MD! ON]
Allows the data input for MDI operation.
Pressing [MDI OFF] key returns the mode to accept the input of a command. [COMMENT ON/OFF]
Selects whether or not a comment is displayed below symbols. For a comment, the first 16 characters are displayed.
(Figs. 6-5, 6-6)
Page 135
4194-E P-124 SECTION 6 PLC MONITOR FUNCTION
[AUTO OPERATION SEIGYO. MIN OSHTT_N, a)\ r__ 97/07/15 14:10:00 LADDER MODULE =SPINDLE No. POOR age tO I = 1/24 ods | x. dsdo U. OO0E eats | U. OO0E a Oy L mor a Ms M. 0800, | - - [ LG0452 LMOV =s-: 010020 | - 6. 0220 low Vv
CMNT: Spindle run ready
| COMMENT | DATA ON/OFF} ON/OFF
(FI CF2 }(F3}(F4)(F5)(F6)(F7)(F8)
Fig. 6-5 Display with Comment OFF Setting
CUNT: Spindle run ready
(= OPERATION SEIGYO. MIN OSHTT_N oO] 97/07/15 14:10:00 LADDER MODULE =SPINDLE QO. =; 4 PAGE 1/24 ZI rth Ay | Te ode N..0800 U. O00E Spindle Spindle Spindle run reac seérvo re servo re t foots | NC reset PB, | 8 . OOOE Spindle servo re f= ( ) ( Pa ¢ oda 6 de M. 0800 w | Spindle Spindle Spindle Vv servo re run read servo re
COMMENT | DATA ON/OFF | ON/OFF
¥ | | QUIT ent FI(F2)(F3)(F4)(F5)(F6)(F7)(F8)
Fig. 6-6 Display with Comment ON Seiting
[DATA ON/OFF] Selects whether identifierfabel should be displayed or contents of data memory of identifier should be displayed. [QUIT] Returns the menu to the PLC monitor function menu. [EXTEND] Calls function 1.
Page 136
4194-E P-125 SECTION 6 PLC MONITOR FUNCTION
3-3. Data Trace Function
The data trace function collects the data specified by an identifier or a label in predetermined cycles to the buffer and displays it.
When the data trace function is started, the trace condition setting screen is displayed first.
Press function key [F5] (TRACE SCREEN) and the trace execution/8-kind data display screen is displayed. In the second and later start-up of the data trace function, the function starts from last screen.
(a) Trace condition setting screen
(cm OPERATION SEIGYO. MIN OSHTTN 7)
L_ 97/07/15 14:10:00 |
DATA TRACE
SAMPLING CYCLE tee(a)t22 msec POWER ON TRACE are (b) S48
TRIGGER SIGNAL et (c) oF TRIGGER COND(d) Fr (e) £35
BEFORE TRIGGER ee (fT) Fee AFTER TRIGGER ate(g) ere TRACE DATA CODE
No.1 #REeRbaaE deze No. 2 aepanenes eate No. 3 Pela tta rer: No. 5 fe sees: fer MENU OF SETTING DATA No.6 Reeteater Be es
No. 8 secstence o Eset
Bl F4)(.F5)(F6 | F7 |(F8 |
Ls | (FI(F2) (b) Functions
[SET]
Sets the input data at the cursor position.
Data setting menu changes according to the item to be set. [IDENT/LABEL]
Selects the objective of label display from identifier and label.
If a label is not stored although label display is selected, an identifier is displayed. [TRACE SCREEN]
Changes the screen to the trace execution screen. [QUIT]
Returns the menu to the PLC monitor function menu.
Page 137
4194-E P-126 SECTION 6 PLC MONITOR FUNCTION
< Setting items > Move the cursor to the data setting item using the cursor keys ( @ : @) : ©) ; ©) ). - SAMPLING CYCLE (a)
Set the sampling interval.
6.4 msec 25. 6 msec 102. 4 msec 204, 8 msec 512. 0 msec TS TASK 0 TS TASK 1
CYCLE
OoORWNM =o
Fig. 6-7 Sampling Interval Setting Data Menu
The list of data to be set is displayed.
After pressing function key [F1] (SET), input the number to be selected and press the WRITE key. Selection is possible from the following seven items.
Values in [ ] are set.
0: 6.4msec (Default) 1: 25.6 msec
2: 102.4 msec
3: 204.8 msec
4: 512.0 msec
5: TS TASKO
6: TS TASK1
Page 138
4194-E P-127 SECTION 6 PLC MONITOR FUNCTION
- POWER ON TRACE (b)
Set whether or not data trace is executed at turning on the power.
POWER ON TRACE
0: Tz
NO DATA TRACE DATA TRACE
Fig. 6-8 Power ON Data Trace Setting Data Menu
The list of data which can be set is displayed.
After pressing function key [F1] (SET), input the number heading the data to be selected and press the WRITE key.
Selection is possible from the following two items.
Values in [ ] are set. 0: NO DATA TRACE 1: DATA TRACE
- TRIGGER SIGNAL (c)
Set the identifier used as the trigger for starting sampling.
Default is “blank” (not set) and trigger condition is invalid.
IDENTIFIER
Wi Iz LI WM M
LM WK K, LK ‘
“BIT INPUT
BIT INPUT
BIT INPUT AUXILIARY RELAY AUXILIARY RELAY AUXILIARY RELAY KEEP RELAY
KEEP RELAY
KEEP RELAY TIMER RELAY
Fig. 6-9 Trigger Signal Setting Data Menu
The list of identifiers which can be set is displayed.
Page keys ( : ) are used to change the display page of the list. After pressing function key [F1] (SET), input an identifier and press the WRITE key. The input identifier is set.
Page 139
4194-E P-128 SECTION 6 PLC MONITOR FUNCTION
- TRIGGER COND (d)
Set the sampling trigger condition.
TRIGGER 0: TRIGGER BIT OFF ->ON START 1: TRIGGER BIT ON ->OFF START 2: TRIGGER ->CHANGE START 3: TRIGGER.= STANDARD VALUE START
Fig. 6-10 Trigger Condition Setting Data Menu
The list of data to be set is displayed.
After pressing function key [F1] (SET), input the number to be selected and press the WRITE key.
If the trigger signal is a bit identifier, setting is possible from 0, 1, and 2, and ifthe trigger signalisa word/long word identifier, setting is possible from 2 and 3.
Values in[ ] are set. 0: TRIGGER BIT OFF, > ON START [-> ON] (DEFAULT) 1: TRIGGER BIT ON, > OFF START [+> OFF] 2: TRIGGER, > CHANGE START [-> CHG] 3: TRIGGER = STANDARD VALUE START [= EQU] (the standard value set for the following item is displayed as the trigger condition.) - STANDARD VALUE (e)
Set the standard value if “3: TRIGGER = STANDARD VALUE START’ is set for the trigger condition. The set value is invalid for other trigger conditions.
SET STANDARD VALUE
After pressing function key [F1] (SET), input the number heading the required trigger condition and press the WRITE key.
Page 140
4194-E P-129 SECTION 6 PLC MONITOR FUNCTION
Setting range varies according to the selected trigger signal: Word identifier:, 32768 to 32767 (O000H to FFFFH)
Long word identifier: ~ - 2147483648 to 2147483647 (O0000000H to FFFFFFFFH)
BEFORE TRIGGER (f) Set the number of data to be collected before the trigger condition is established.
After pressing function key [F1] (SET), input the number of data to be collected and press the WRITE key. The input number is set.
Setting range: Oto 511 Default after setting trigger signal is “O”. AFTER TRIGGER (g) Set the number of data to be collected after the trigger condition is established.
After pressing function key [F1] (SET), input the number of data to be collected and press the WRITE key. The input number is set.
Settingrange: Oto0512 Default after setting the trigger signal is “512”. Default before setting the trigger signal is “O”. TRACE DATA (h) Sei the trace target data.
Default is “blank” (not set).
IDENTIFIER WI BIT INPUT l. BIT INPUT LI BIT INPUT
WM = AUXILIARY RELAY M AUXILIARY RELAY LM = AUXILIARY RELAY WK KEEP RELAY
K. KEEP RELAY
LK KEEP RELAY es TIMER RELAY
Fig. 6-11 Trace Signal Name Setting Data Menu
The list of data which can be set is displayed.
Use the page keys ( ' ) to change the list of data.
After pressing function key [F1] (SET), input the identifier to be selected and press the WRITE key. The input identifier is set.