Page 1 of CNC Systems OSP-U100M, OSP-U10M, MX-V Series Maintenance Manual

Manual · Okuma

CNC Systems OSP-U100M, OSP-U10M, MX-V Series Maintenance Manual

Manual208 pagesPDF 22 MB

Maintenance manual for the Okuma OSP-U100M and OSP-U10M CNC systems on MX-V series machines, including the FUB-DR3 FieldNet unit.

What this file really is

The old site listed this file as a manual for the Okuma FUB-DR3. This is not a manual for the FUB-DR3 alone but the maintenance manual for the Okuma OSP-U100M/OSP-U10M CNC systems on MX-V series machines, in which the FUB-DR3 is one of the I/O units described.

Download the PDF22 MB

Filed under · 1 model

Filed under these models in the old catalog

Summary

What is in it

The maintenance manual for the Okuma OSP-U100M and OSP-U10M CNC systems used on MX-V series machines. It outlines the system and its units, including the FUB-DR3 FieldNet unit with its power sequence circuit and LED indicators, then covers maintenance and inspection, troubleshooting, the self-diagnostic function, machine diagnosis messages and ATC/APC logic tables, the PLC monitor function, PLC program instructions, installing software and changing the battery.

Its parts

  1. Outline of OSP
  2. Maintenance and Inspection
  3. Troubles and Troubleshooting
  4. Self-Diagnostic Function
  5. Machine Operation Conditions, Diagnosis Messages, and Logic Tables
  6. PLC Monitor Function
  7. PLC Program Instructions
  8. Installing Software
  9. Changing the Battery

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

This is the Okuma Maintenance Manual for the OSP-U100M and OSP-U10M CNC systems on MX-V series machines, publication 4194-E, 1st edition, May 1998. The site files it under the FUB-DR3, the FieldNet Model B unit with the power sequence function, which the manual describes in its system outline. The manual also walks through inspection, troubleshooting, self-diagnostics, PLC program instructions, software installation and battery changing for the CNC.

Read for this summary: pages 1 to 3, 7 to 23, 37 to 41 and 44 of 208.

What it is
FieldNet Model B unit with the FieldNet interface, the power sequence function and a built-in optical conversion module p. 17
Input rating
24 VDC, 14 mA typical p. 19
MOS IC outputs
Most outputs are power MOS IC outputs rated 2 A (24 VDC) p. 18, 20
Relay outputs
Max contact current 5 A or 2 A depending on the contact (30 VDC, 250 VAC, resistance load) p. 21
Output LEDs
Green LEDs OUT1 to OUT12 light when the matching output signal is on p. 22
Oscillator LED
100 Hz oscillator; yellow OSCSTP LED lights if it stops p. 23
OFF delay timers
One 0.3 sec OFF delay timer and one changeable to 5, 10 or 20 sec p. 18
Power sequence inputs
Power ON and OFF buttons, calendar timer, emergency stop button, feed axis stroke end switch, PLC commands p. 19
Output signals
Axis control ON, emergency stop monitor, axis power ON, NC and EC axis brake release, NC power ON and OFF, main breaker OFF, emergency stop p. 22
Companion units
FUB-P4M4: 4 bytes photocoupler inputs, 4 bytes power MOS IC outputs; FUB-P4R2: 4 bytes photocoupler inputs, 2 bytes relay outputs p. 17
CNC power supply unit
Takes 24 VDC and supplies +5 V, +12 V and -12 V to the CPU p. 16
UCMB main board
Main CPU board with one RS232C channel and a 3.5-inch floppy disk drive interface p. 15
Machine power supply
200 V, 50/60 Hz, voltage fluctuation 10% max p. 2
Control enclosure
0 to 40°C, 30 to 95% humidity (no condensation), up to 1000 m (3281 ft.) p. 2

What this manual walks you through

  • Reading the FUB-DR3 power sequence circuit p. 18
  • Matching the FUB-DR3 output LEDs to output signals p. 22
  • How the I/O link and servo link connect the units p. 13
  • General checks when trouble occurs p. 37
  • Finding why a machine stopped and does not restart p. 38
  • Checking input and output signals on the I/O CHECK screen p. 39, 40, 41
  • Reading the power supply unit status LEDs p. 44
  • Site and power requirements for installing the machine p. 2

Good to know

  • Do not remove an NC PCB from the NC rack while power is on. p. 15
  • When removing the UCMB with its battery unit connected, shorting IC or connector pins can wear the battery and lose memory contents. p. 15
  • Turn on the main power disconnect switch first, then the CONTROL ON switch. p. 3
  • Do not feed the machine from a distribution panel that also supplies a major noise source such as a welder. p. 2
  • The CNC power supply unit stops the CPU if it detects an error in the 24 VDC input or the +5 VDC output. p. 16

Questions this manual answers

What is the Okuma FUB-DR3?

A FieldNet Model B unit in the Okuma OSP CNC system that has the FieldNet interface, the power sequence function and a built-in optical conversion module. p. 17

What do the green OUT LEDs on the FUB-DR3 mean?

Each green LED lights when its output signal is on; for example OUT11 is main breaker OFF and OUT12 is emergency stop. p. 22

What does the yellow OSCSTP LED on the FUB-DR3 mean?

It lights when the unit's 100 Hz oscillator stops. p. 23

What are the FUB-DR3 output ratings?

Its power MOS IC outputs are rated 2 A at 24 VDC; its relay contacts allow 5 A or 2 A max at 30 VDC or 250 VAC, resistance load, depending on the contact. p. 20, 21

How do I check whether an input or output signal is on?

Press function key F7 (CHECK DATA) and page to the I/O CHECK screen; a highlighted label means the signal is ON. p. 39, 40

The whole text · 21 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 160151-160
  17. Pages 161 to 170161-170
  18. Pages 171 to 180171-180
  19. Pages 181 to 190181-190
  20. Pages 191 to 200191-200
  21. Pages 201 to 208201-208

The file

Revision and size

RevisionPub. No. 4194-E (ME34-040-R1), 1st Edition, May 1998
PublisherOkuma
Pages208
PDF22 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 3 of 208

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 208
Page 2
Page 2of 208
Page 3
Page 3of 208