Manual · Okuma
CNC Systems OSP-U100M, OSP-U10M, MX-V Series Maintenance Manual
Manual208 pagesPDF 22 MB
Maintenance manual for the Okuma OSP-U100M and OSP-U10M CNC systems on MX-V series machines, including the FUB-DR3 FieldNet unit.
What this file really is
The old site listed this file as a manual for the Okuma FUB-DR3. This is not a manual for the FUB-DR3 alone but the maintenance manual for the Okuma OSP-U100M/OSP-U10M CNC systems on MX-V series machines, in which the FUB-DR3 is one of the I/O units described.
Filed under · 1 model
Filed under these models in the old catalog
Summary
What is in it
The maintenance manual for the Okuma OSP-U100M and OSP-U10M CNC systems used on MX-V series machines. It outlines the system and its units, including the FUB-DR3 FieldNet unit with its power sequence circuit and LED indicators, then covers maintenance and inspection, troubleshooting, the self-diagnostic function, machine diagnosis messages and ATC/APC logic tables, the PLC monitor function, PLC program instructions, installing software and changing the battery.
Its parts
- Outline of OSP
- Maintenance and Inspection
- Troubles and Troubleshooting
- Self-Diagnostic Function
- Machine Operation Conditions, Diagnosis Messages, and Logic Tables
- PLC Monitor Function
- PLC Program Instructions
- Installing Software
- Changing the Battery
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
This is the Okuma Maintenance Manual for the OSP-U100M and OSP-U10M CNC systems on MX-V series machines, publication 4194-E, 1st edition, May 1998. The site files it under the FUB-DR3, the FieldNet Model B unit with the power sequence function, which the manual describes in its system outline. The manual also walks through inspection, troubleshooting, self-diagnostics, PLC program instructions, software installation and battery changing for the CNC.
- What it is
- FieldNet Model B unit with the FieldNet interface, the power sequence function and a built-in optical conversion module p. 17
- Input rating
- 24 VDC, 14 mA typical p. 19
- MOS IC outputs
- Most outputs are power MOS IC outputs rated 2 A (24 VDC) p. 18, 20
- Relay outputs
- Max contact current 5 A or 2 A depending on the contact (30 VDC, 250 VAC, resistance load) p. 21
- Output LEDs
- Green LEDs OUT1 to OUT12 light when the matching output signal is on p. 22
- Oscillator LED
- 100 Hz oscillator; yellow OSCSTP LED lights if it stops p. 23
- OFF delay timers
- One 0.3 sec OFF delay timer and one changeable to 5, 10 or 20 sec p. 18
- Power sequence inputs
- Power ON and OFF buttons, calendar timer, emergency stop button, feed axis stroke end switch, PLC commands p. 19
- Output signals
- Axis control ON, emergency stop monitor, axis power ON, NC and EC axis brake release, NC power ON and OFF, main breaker OFF, emergency stop p. 22
- Companion units
- FUB-P4M4: 4 bytes photocoupler inputs, 4 bytes power MOS IC outputs; FUB-P4R2: 4 bytes photocoupler inputs, 2 bytes relay outputs p. 17
- CNC power supply unit
- Takes 24 VDC and supplies +5 V, +12 V and -12 V to the CPU p. 16
- UCMB main board
- Main CPU board with one RS232C channel and a 3.5-inch floppy disk drive interface p. 15
- Machine power supply
- 200 V, 50/60 Hz, voltage fluctuation 10% max p. 2
- Control enclosure
- 0 to 40°C, 30 to 95% humidity (no condensation), up to 1000 m (3281 ft.) p. 2
What this manual walks you through
- Reading the FUB-DR3 power sequence circuit p. 18
- Matching the FUB-DR3 output LEDs to output signals p. 22
- How the I/O link and servo link connect the units p. 13
- General checks when trouble occurs p. 37
- Finding why a machine stopped and does not restart p. 38
- Checking input and output signals on the I/O CHECK screen p. 39, 40, 41
- Reading the power supply unit status LEDs p. 44
- Site and power requirements for installing the machine p. 2
Good to know
- Do not remove an NC PCB from the NC rack while power is on. p. 15
- When removing the UCMB with its battery unit connected, shorting IC or connector pins can wear the battery and lose memory contents. p. 15
- Turn on the main power disconnect switch first, then the CONTROL ON switch. p. 3
- Do not feed the machine from a distribution panel that also supplies a major noise source such as a welder. p. 2
- The CNC power supply unit stops the CPU if it detects an error in the 24 VDC input or the +5 VDC output. p. 16
Questions this manual answers
What is the Okuma FUB-DR3?
A FieldNet Model B unit in the Okuma OSP CNC system that has the FieldNet interface, the power sequence function and a built-in optical conversion module. p. 17
What do the green OUT LEDs on the FUB-DR3 mean?
Each green LED lights when its output signal is on; for example OUT11 is main breaker OFF and OUT12 is emergency stop. p. 22
What does the yellow OSCSTP LED on the FUB-DR3 mean?
It lights when the unit's 100 Hz oscillator stops. p. 23
The whole text · 21 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
- Pages 161 to 170161-170
- Pages 171 to 180171-180
- Pages 181 to 190181-190
- Pages 191 to 200191-200
- Pages 201 to 208201-208
The file