Page 41
4194-E P-30 SECTION 3 TROUBLES AND TROUBLESHOOTING
(3)
Checking the Output Signals
The procedure for checking the status of the spindle tool internal cylinder unclamp solenoid using the I/O CHECK screen is explained below as an example. Other output signals can be checked in the same manner.
From the Field Net input wiring diagram, supplied separately, it is found that the signal for operating the spindle tool internal cylinder unclamp solenoid is output from check No. 29, bit 8.
So, display the CHECK DATA screen for I/O CHECK No. 29 and see the label “olSUC” of bit 8 of OUTPUT. When the label is highlighted, it indicates that the output signal is ON. Conversely, when the label is not highlighted, it indicates that the output signal is OFF.
lf the spindle tool internal cylinder unclamp solenoid has not operated although the output signal for operating the spindle tool internal cylinder unclamp solenoid is ON (label highlighted), the spindle tool internal cylinder unclamp solenoid will be faulty.
Page 42
4194-E P-31 SECTION 3 TROUBLES AND TROUBLESHOOTING
4. CPU Status Indication
Whether the computer is running normally or not can be checked by simply observing the display in the screen at the operation panel. If it is operating, the computer is judged to be running normally. For example, changeover the screen display and when the screen display changes accordingly, you can judge that the computer is running normally.
_ To check the status of the computer, status indicating LED lamps are provided on the UCMB (UC main board) (see Fig. 3-2). ;
(1) Contents of Indication
RUN: RUN The GPU is running to execute an instruction (calculating an instruction).
PRT: PROTECT ERROR The CPU has accessed an address area in the prohibited mode, or it has accessed an unused address area.
PAR: PARITY ERROR During the access to the system bus by the CPU in this board, a parity error was detected in the read data. LOP: LOOP ERROR An interruption processing occurring in a predetermined cycle (RTC) has not finished before the occurrence of the next interruption.
ECC: ERROR CHECK & In the access to the main memory, there was an error in the CORRECT ERROR contents of the memory at the specified address.
DIA: DIAGNOSTIC ERROR |The output diagnose data differed from the normal data ($55).
CYO: CYCLE OVER ERROR |The CPU bus cycle of this board has not finished within a preset time.
SBER: SYSTEM BUS ERROR | Aslave station detected an error while the CPU of this board was accessing the system bus as the bus master.
(2) CPU Operating Status Indication (a) While the CPU is running normally, only the RUN lamp (green) is lit. (b) At the occurrence of a bus error, an LED lamp (red) showing the cause of the error lights. The RUN lamp (green) stays lit during bus error processing. (c) If the CPU enters the halt state due to double-bus error, the RUN lamp (green) goes off.
The LED lamp (red) showing the cause of the double-bus error lights.
(d) If all of the LED lamps are lit, either the 5 V power is not supplied or the CPU is in the reset state.
(e) An error indication shows the trouble of the CPU and it is not cleared by the CNC reset operation.
(f) To restart the CNC, turn off the power once and then turn it back on. If the trouble which has occurred continues, the same error occurs again and the CNC stops. If the CNC operates normally, allow the CNC operating to observe the situation.
Page 43
4194-E P-32 SECTION 3 TROUBLES AND TROUBLESHOOTING bec) =! o JLoKUMA
RUN (green), ?_. 6 aw O lew PRT (red), - O O-
PAR (red) = - - 1 +6 par Oui LOP (red), +~ - eO uP O - ECC (red) 9, - + - -»O ot DIA (red) + = - t - -O 1A CYO (red) 9 - - O on SBER (red), - j7 - *-O SR
O = INSTALL Om © 3 | O .
1b-22
Da he nate [ - ]
Fig. 3-2 LED Indication on UCMB (UC Main Board)
Page 44
4194-E P-33 SECTION 3 TROUBLES AND TROUBLESHOOTING
Power Supply Unit Status Indication
(1) Check by LED Indication
The power supply unit has the function which monitors the input/output voltage and the output current constantly and the function turns off the status indicating LED lamp if an error is detected. To check the siatus of the power supply unit, check the indication of the LED lamps on the power supply unit. See Fig. 3-3.
Indicating lamp (green LED) (A) (B) (C) (D) (E) IN24 V O O O @) +5V O O O #12 V O O O -12V O O O ©: LED ON
(A): The power supply unit is operating normally.
(B): Over current, over voltage, or low voltage of output due to an error of +5 V.
(C): Over current of output due to an error of +12 V.
(D): Over current of output due to an error of, 12 V.
(E): 24 VDC input has lowered to 2.4 V or lower (at 19.2 V or lower, LED status is indefinite.).
(2) Alarm Indication by LED
(a) If a power supply unit alarm occurs due to an error of the +5 V (status indicating LED is OFF), power supply to the CPU is shut off to stop the CPU.
(b) A power supply alarm (status indicating LED is OFF) indicates a trouble related to the power supply unit and the input/output of the power supply unit.
(c) To start the CNC unit, turn the power off once (pressing the CONTROL OFF switch on the NC operation panel) and turn the power on again (pressing the CONTROL ON switch on the NC operation panel). The CPU automatically starts running and the CNC starts operating.
(d) If the trouble which has occurred continues, the same error occurs again and the CNC stops. If the CNC operates normally, allow the CNC operating to observe the situation.
Page 45
4194-E P-34 SECTION 3 TROUBLES AND TROUBLESHOOTING a? JLOKUMA RUN INtay < - _ - __|_____ N24 V (green) = PET ‘ ‘ - - - + _ +5 V (green) O PaR Orlw » - - +12 V (green) O uw O-1 = - - }+ - -12 Vigreen) Ok DIA So O SEE O 18-CPR RESET INSTALL O 7] Ouse 15-0 oO 15-232 18-FDO @
- oe E - ]
Fig. 3-3 LED Indication on the Power Supply Unit
Page 46
4194-E P-35 SECTION 3 TROUBLES AND TROUBLESHOOTING
6. Inspection of Overload Relay
For protecting motors and solenoids, etc., from overcurrent and overload, an overload relay is used.
To reset the tripped relay, push in the reset rod. Note that pushing in the reset rod right after the relay has been tripped, cannot reset the relay. Allow the switch to cool before resetting it.
Magnet Se ees | &) &) &) ®&) [1 1 3125 13 13 \&)
Ai+
I [ oO ‘@) O To reset the relay, press the white part 1 or 2 minutes after it is tripped. A2- - [2 Ti 4 726 314] 6) «&) «&) &) &) This dial is factory-adjusted. Do not touch it. lelele| oO, Overload eee ® es) ®
\
Fig. 3-4 Overload Relay
The circuit breaker and fuses prevent overcurrents from surging through the control circuit.
With circuit breakers, functions of the circuit can be recovered by simply resetting the tripped breaker by holding up the lever.
Page 47
4194-E P-36 SECTION 3 TROUBLES AND TROUBLESHOOTING
7.
Releasing Travel-end Limit
The system panel shown below is provided in the control enclosure and the O.T. RELEASE switch can be used to release the overtravel alarm state caused by the actuation of the overtravel limit switch.
If an overtravel limit switch of an axis is tripped, an alarm message is displayed on the screen and power supply to the servo drive unit is shut off for all axes. To release the overtravel alarm State, follow the procedure indicated below.
< Procedure > (1) Turn the O.T. RELEASE switch up to the “I” position. (2) Press the RESET button on the NC operation panel.
Power supply to the servo drive is turned on for all axes and an alarm message is displayed on the screen. In this state, pulse handle operation only is allowed.
(3) Move the axis, causing the overtravel alarm, in the direction away from the travel-end by turning the pulse handle.
(4) Turn the O.T. RELEASE switch down to the “O” position, then press the RESET bution.
This completes the overtravel alarm release operation. O.T.RELEASE
| ® SENSOR 0O.T.
O
Fig. 3-5
Page 48
tt
4194-E P-37 SECTION 3 TROUBLES AND TROUBLESHOOTING
Check by Machine Diagnosis Messages lf the machine unit such as ATC and APC fails to operate, the self diagnostic function of the CNC displays insufficient conditions for the required operation on the screen, facilitating the check.
For details, refer to Section 5, 2. “Machine Diagnosis Messages”.
Page 49
4194-E P-38 SECTION 4 SELF-DIAGNOSTIC FUNCTION
SECTION4 SELF-DIAGNOSTIC FUNCTION
The CNC unit has the self-diagnostic function using the performance of the built-in computer. The self-diagnostic function provides the following four check functions.
- Check function using the alarm and error display
Check function using the check data display
Check function using the CNC diagnostic display
Check function using the machine diagnostic display
(1)
(2)
Check Function Using the Alarm and Error Display
This function constantly monitors any defect including programming, operational errors and NC malfunctions.
When any defect such as the programming error and CNC malfunction requiring stop of the machine operation occurs, the ALARM lamp goes on, the machine is stopped, and the contents of the alarm will be displayed on the screen. When the defect is an operational error during editing operation, etc. not requiring the machine to be stopped, the ALARM lamp does not go on, but the contents of the error only will be displayed on the screen. From these displays, the contents of the defect can be judged.
Check Function Using the Check data Display
With check data displayed on the screen, it is possible to check internal conditions of the CNC, input/output signals of the CNC and so on. This is a useful function to adjust and check the CNC. Check Function Using the CNC Diagnostic Display
This is the function to constantly monitor the memory in the CNC in the display form of decimal numbers, hexadecimal numbers, floating-point number, bit-string, etc.
Check Function Using the Machine Diagnostic Display
When the machine does not operate because of any of the requirements for the operation of the machine not fulfilled, that unfulfilled condition will be displayed in characters to facilitate operator's inspection work.
Page 50
4194-E P-39 SECTION 4 SELF-DIAGNOSTIC FUNCTION
Alarm and Error Display
The CNC constantly monitors the operating conditions of the machine, the program data and the operation of the machine operator. When any problem takes place, it gives the operator a warning by displaying an alarm message or error message.
(1)
(2)
(3)
Alarm Display
The machine is stopped. The ALARM lamp under NC STATUS goes on. The corresponding alarm message is displayed on the 2nd line of the screen.
Error Display
Mainly warning against any of the items input by the operator, and does not cause the machine to be stopped.
The ALARM lamp does not go on and the error message is displayed on the 18th to 22nd line on the screen. CPU Alarm
This alarm indicates CPU malfunction. When this type of alarm occurs, machine operation cannot be resumed until power supply is turned on again. Naturally, the machine instantly stops.
When the CPU does not function normally, the message is displayed below the central portion on the screen.
Note: For alarm and error messages, refer to Alarm & Error List.