Page 191
4194-E P-180 SECTION 9 CHANGING THE BATTERY
Changing the Battery
< Procedure >
1) Back up the system data and the user file by following the procedure described in 5-3. “Data Backup” in Section 8.
2) Prepare the tools necessary for changing the battery.
- Control enclosure key
- Philips head screwdriver (No. 2) - New battery unit
- Nipper
- Cable ties
Fig. 9-1 Battery unit
3) Place the CNC in the install mode. - Place the MODE toggle switch in the INSTALL frame at the UCMB in the “I” position. - Press the RESET switch.
- The following main menu of the install mode is displayed.
[MAIN MENU] V4. 01 - A (ENG)
1. INSTALL
2, FR-INSTALL 3. MD -INSTALL 4. MAINTENANCE
INSTALL PROGRAM V4, 01-A (ENG) OKUMA 1997. 10. 31
Please select a number, (1/2/3/4) |_
Page 192
4194-E P-181 SECTION 9 CHANGING THE BATTERY
4) Select “4. MAINTENANCE”,
- The following maintenance tool menu is displayed.
[Maintenance tool ]
User file backup System data backup Replace .
6, Battery exchange preparation 7. Battery exchange restoration 8. Initialize memory disk
System data store User file store oF Se
MAINTENANCE TOOL V1. 00 - A (ENG) OKUMA 1997, 10. 27
Please select anumber. (1/2/3/4/5/6/7/8) !_
5) Select “6. Battery exchange preparation”.
- Follow the instructions displayed on the screen to prepare for changing the battery.
[Maintenance tool ]
System data store User file store
Be Bae
~
Please select anumber. (1/2/3/4/5/6/7/8) !6
Do you exchange battery?
Were user files backed up? (Y/N) lY
Were system data backed up? (Y/N) !Y
System is charging condenser.
Please wait forawhile. .............0005-
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration - Replace 8. Initialize memory disk completed
Turn off a power, and please rapidly exchange battery,
[Supplement] lf you input “N”, the screen returns to the maintenance tool menu screen.
Page 193
4194-E P-182 SECTION 9 CHANGING THE BATTERY
6) Change the battery. - Turn off the power and change the battery.
Remove the machine screw at (a) and change the battery unit.
_
8-00 @ xB-FDO 2 ° oe a2 HS 98 28 (a) 33 28) 38 38 33 2 c =F o§ 2 o o° So of ' 08 o8 a5 a) & < ot Oi ae OKUMA OKUMA
Fig. 9-2 7) Restore the CNC.
- Display the maintenance tool menu following steps 3) and 4) and select “7. Battery exchange restoration”.
- Follow the instructions displayed on the screen to restore the CNC.
[Maintenance too! ]
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration Replace 8. Initialize memory disk
System data store User file store
BY Ps 00 os
~
Please select anumber, (1/2/3/4/5/6/7/8) !7
Was battery exchange?
Memory check OK battery voltage OK
Battery life alarmcancel lation. Battery exchange was completed.
Please select anumber. (1/2/3/4/5/6/7/8) 1
- If the battery change has completed normally as shown above, it is not necessary to load the backup system data and user files.
Page 194
4194-E P-183 SECTION 9 CHANGING THE BATTERY
- If the result of memory check is abnormal, the following message is displayed. Data of a memory disk have disappeared.
To restore the CNC in this state, it is necessary to initialize the memory disk and install the software, After installing the software, load the system data and user files from the backup disks.
- If the result of battery voltage check is abnormal, the following message is displayed. Battery voltage insufficiency.
System is charging condenser. Please wait for a while. ...................0. completed
Turn off a power, please confirm battery is exchanged righily.
lf this message is displayed, check the connection of the battery lead connector and the battery itself. After making sure the cause of the problem, change the battery again.
8) Turn on the power. - Place the MODE toggle switch in the INSTALL frame at the UCMB in the "O” position.
- Turn on the control power again.
Page 195
4194-E P-184 SECTION 10 APPENDIX
SECTION 10 APPENDIX
1. Accessories
The following items are supplied with the control enclosure. Since these items are necessary for the service by Okuma, please keep them in places where they are stored when the machine is delivered.
- Check sheet (control system)
- OSP control card
- Floppy disks
1-1. Check Sheet (Control System)
The check sheet shows the results of inspection and the information on after-sale services of the CNC.
1-2. OSP Control Card
The file includes software control card, hardware control card, and data sheet,
The data sheet keeps the record of the system-related parameter data, set at the shipping of the machine.
1-3. Floppy Disks
One set of OSP control floppy disks is provided.
NOTICE
: Keep the following in mind when handling floppy disks.
(1)
Keep the floppy disks in the case when they are not used. The floppy disk case must be kept at the specified place inside the control enclosure; avoid exposure to high temperature, high humidity, and direct sunlight.
Do not attempt to open the floppy disk shutter.
Keep the write-protection tub in the “protected” position to protect the data from being deleted by mistake.
Set a floppy disk in the floppy disk drive correctly. Keep away magnetism.
Less then 4000 A/M (50 Gauss)
Environmental requirements
Temperature: 10 to 50°C (50 to 122°F) Humidity: 20 to 80%RH
Page 196
4194-E P-185 SECTION 10 APPENDIX
2. NC Operation Panel
(1) NC Operation Panel with 14” CRT
-, - Ge Cciqias
Ae
DHE =] Q@am
OS@w HOO 2] GOS
GO @
~
Le [Ln AG ZIEL
~
(clo FF ae) aL fol halal aa x‘
AE ar ae
EPR RYO
Page 197
4194-E P-186 SECTION 10 APPENDIX
(2) NC Operation Panel with LCD (Horizon tal Type), LE) 8&1 J)
BRE
EKcee Hee 19800 li cc E 8008
=}\_ I
2 os = ute ieee a
[ mn SUP. CimMit, Aun S.T.M =
BORD DMM ()
Page 198
4194-E P-187 SECTION 10 APPENDIX
(3) NC Operation Panel with LCD (Vertical Type)
h ( ) ai ay es helt SMHMMmAmAmAME S| J
22S) Ga Gp Gm aa aay ‘Als leo LET fe) aalo ELEC Oa ©
Page 199
(1)
3.
=
NC OPERATION, 7 - - ATC OPERAT | QN - ,
(TJ CYCLE START fulznoa | iinaon [Zirrnon cack] (Frocauul / | r-AXIS SELECT PRX IMAGE |] IMAGE || IMAGE SKIP || BRANCH]| BRANCH DISPLAY an SHINGLE} 1 STOP ||8 kK) (eel = aaa: Mw. x Y 2 x 2 OFF Sa Ie P ~ 4 Fund DAY a ame stall cous (10, vance | [seournce F a . Hl OCONTROL OFF 4 o Lock j{ Run Stop || cock |{ cancer) | wanuac}| sHtet||REStART : > fOl SLIOE WLC mm ¥* JOG, ~Y [7 VA 5 . oes [+] (-] 6 (- | | uicur jl! wa. coovant} [4.0n02J[apanrr % = os WZ Y RESTART (Q] ea, Ee; £ fu Aol vy et or tase 00 cure con [can c | Ga
7, KS ort wove) | HIGH | Suomen UU% OVERRIDE = FC) % SPINOLE OVERRIDE © Iun/ain) SPEED = YO FEEDRATE
40 50 {10 120 139 1000 «0 19 ap HC PANEL, i FREE wmoce ocr a RESET, UY RAPID, EMG. STOP
Machine Operation Panel
Horizontal Type Machine Operation Panel
SECTION 10 APPENDIX
4194-E P-188
Page 200
4194-E P-189 SECTION 10 APPENDIX
(2) Vertical Type Machine Operation Panel f ~) > NC OPERAT 108, - - - - ,, ATE ac EMG . STOP JCONTROLON OCONTROL OFF (7 (a YSLOCK Oca SKIP |] BRANCH|| Branch | |DISPLAY| {OPT soMA!| [SINGLE i | 1 ie bey stop IIBLock CYCLE |] S.T.M le I AT HANDLE ze STOP J| LOCK CANCEL MANUAL | SHIFT || [RESTART r - AXiS SELECT, I ~ Catracn | [Arnon | Aaaacn inca) (A ie | C14 (LHI CYCLE START x y Zz IMAGE |] IMAGE ees ea TH rd ne J ¥ WB SPL a COOLANT], ABADAP aa YY @ | Viren | (| laid Z 5 j{ purse} | voce | |wacuing if WES J HANDLE RELEASE || LOCK Hi (| es) OL Mist Wn Z| 7 (©! SLIDE HOLD a bal a RAPID (Vain) JOG 7% OVERRIDE FO* SPINDLE OVERRIDE Viv (usin) SPEED “% RESET 9 32 0 24 110 120 139 en 1000 40 scanps 5 0 0 ‘ OS DOOR ITERLOCK,,,NC PANEL 0 cD RESTART =f © ERT umoct wer 6000 240 Q) (| 50 0.04 ¢ 10000 400 J /