Page 181
4194-E P-170 SECTION 8 INSTALLING SOFTWARE
3) Select “4. MAINTENANCE”.
- The following maintenance tool menu is displayed.
[Maintenance tool]
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration Replace 8. Initialize memory disk
System data store User file store ee al US ia
MAINTENANCE TOOL V1. 00 - A (ENG) OKUMA 1997. 10. 27
Please select anumber, (1/2/3/4/5/6/7/8) Mg
4) Select “8. Initialize memory disk”.
[Maintenance tool ]
User file backup 6. Battery exchange preparation System data backup 7, Battery exchange restoration Replace 8. Initialize memory disk
System data store User file store poh > ER BD ee
Please select anumber. (1/2/3/4/5/6/7/8) 18 Do you want to start memory disk initial ize? (Y/N) LY
Please input a present date. date (Y. M. D) !97. 10. 10
Please input a present time. time (H:M:S) !11:15:00
System initialize memory disk Are you sure? (Y/N) lY
5) The messages change as “doing” ...... “completed” With this, the MD initialization processing is complete.
Install the software in the MD again.
NOTICE : Ifthe MD is initialized, all contents in the MD such as system data and user files are lost. The necessary data must be backed up before initializing the MD.
Page 182
4194-E P-171 SECTION 8 INSTALLING SOFTWARE
5-3. Data Backup
5-3-1. Cases Requiring Data Backup Operation
When installing the software in the memory disk (C-MOS memory) for the machine where the control software has been installed and the NC has ever operated, it is necessary to back up the data. If the software is installed in the memory disk, the memory disk is cleared, parameters are reset to the default values, and all part programs are deleted. Therefore, the necessary data must be saved to the backup disk before installing the software in the memory disk; after the installation of the software, the backup data should be loaded to the memory disk to restore the previous status.
The data that requires backup are indicated below. (1) System data such as zero offset, tool offset, and parameters (2) Part program files such as part programs, subprograms, and schedule programs
[Supplement] When installing the software for the first time, this data backup operation is not necessary. 5-3-2. Backup of the System Data
Backup operation of the system data stores the files having the following extensions in the system backup floppy disk.
- *.PBU - *.PAR - x.UTY
All of the files indicated above are not existent in the system depending on the machine specifications.
5-3-3. Backup of the User Files Save the user files in MD1: to the work floppy disk.
5-3-4. Backup Procedure 1) Turn on the control power.
2) Place the CNC in the install mode. - Place the MODE toggle switch in the INSTALL frame at the UCMB in the “I” position. - Press the RESET switch. - The following main menu of the install mode is displayed.
[MAIN MENU] V4. 01 - A (ENG)
1. INSTALL
2. FR-INSTALL 3. MD -INSTALL 4. MAINTENANCE
INSTALL PROGRAM V4. 01-A OKUMA 1997. 10, 31
Please select anumber. (1/2/3/4) !_
Page 183
4194-E P-172
SECTION 8 INSTALLING SOFTWARE
3) Select "4. MAINTENANCE”,
- The following maintenance too! menu is displayed,
[Maintenance tool]
System data store User file store
AT ING
MAINTENANCE TOOL V1. 00 - A (ENG) OKUMA 1997. 10, 27
Please select anumber. (1/2/3/4/5/6/7/8) fe
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration Replace é 8. Initialize memory disk
4) Store the user files in the backup disk.
- Set a work disk used io back up the user files into the floppy disk drive.
- Select"1. User file backup” and follow the instructions displayed in the screen to store the user files in the backup floppy disk.
[Maintenance tool]
System data backup Replace
User file backup 6. Battery exchange preparation
7, Battery exchange restoration 8. Initialize memory disk
System data store User file store
St FSO fal
~
Please select anumber, (1/2/3/4/5/6/7/8) 11
Please press [Write] key after insert ing auser file backup floppy.
May user files be backed up ona fl oppy? (Y/N) ly (File name)
Backup of user files were completed.
Please select anumber. (1/2/3/4/5/6/7/8) i
5) Store the system data to the backup disk.
- Set a work disk used to back up the system data into the floppy disk drive.
- Select “2. System data backup” and follow the instructions displayed in the screen to store the system data in the backup floppy disk.
NOTICE
: The system data backup operation deletes the existing files in the floppy disk unconditionally.
Page 184
4194-E P-173 SECTION 8 INSTALLING SOFTWARE
[Maintenance too! ]
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration Replace 8. Initialize memory disk
System data store User file store
OF Pn
~~ ~
Please press [WRITE] key after inserting a system backup floppy
May system data of memory be backed up on a floppy? (Y/N) IY (File name)
Backup of system data were completed, Please select anumber. (1/2/3/4/5/6/7/8) !_
Page 185
4194-E P-174 SECTION 8 INSTALLING SOFTWARE
Installing the Control Software
Use Order of Floppy Disks
When installing the software, the order of setting floppy disks the floppy disks in the order shown in the floppy disk label.
is important. Install the software by setting
Floppy disk setting order is indicated in </> atthe upper right part in the label.
## ONC CUSTOM FLOPPY ## OsP TYPE:
S/N:
~
OKUMA CORPORATION
< 1/ 6> se Se oan nese af
Floppy disks of the standard specifications are identified by the installation order numbers as shown below.
< 1/6> ist FD NC custom floppy disk
< 2/6 > 2nd FD System package floppy disk <3/6> 8rd FD NC package floppy disk
< 4/6 > 4th FD MacMan package floppy disk < 5/6 > 5th FD PLC custom floppy disk 1
< 6/6 > 6th FD PLC custom floppy disk 2
The number of package floppy disks varies according to the disks is
<1/n> 1st FD NC custom floppy disk < 2/n >to <(n-2)/n> 2nd FD to 3rd FD from the last Package floppy disks < (n-1)/n > 2nd FD from the last PLC custom floppy disk <n/n> Last FD PLC custom floppy disk
(?NC CUSTOM FLOPPY) (SYSTEM PACKAGE FLOPPY) (?NC PACKAGE FLOPPY)
(? MACMAN PACKAGE FLOPPY) (?PLC CUSTOM FLOPPY 1) (?PLC CUSTOM FLOPPY 2)
selected options. If total number of floppy
“n”, the configuration of floppy disks is as indicated below
(?NC CUSTOM FLOPPY)
(PACKAGE FLOPPY)
(?PLC CUSTOM FLOPPY 1) (?PLC CUSTOM FLOPPY 2)
Page 186
4194-E P-175 SECTION 8 INSTALLING SOFTWARE
5-4-2. Operation Procedure INSTALL Mode
1) Turn on the control power.
2) Place the CNC in the install mode. - Place the MODE toggle switch in the INSTALL frame at the UCMB in the “I” position. - Press the RESET switch.
- The following main menu of the install mode is displayed.
[MAIN MENU] V4. 01 - A (ENG)
INSTALL
FR -INSTALL MD -INSTALL MAINTENANCE oo N=
INSTALL PROGRAM V4. 01 - A (ENG) OKUMA 1997. 10. 31
Please select anumber. (1/2/3/4) !_
3) Select “1. INSTALL”.
- The following screen is displayed.
[INSTALL] ao wr, MAIN MENU
Please select anumber. (1/2/3) 11
Please insert acontrol - floppy. Please press WRITE key after inserting a floppy. Install procedure will be completed by [Q] key.
Page 187
4194-E P-176 SECTION 8 INSTALLING SOFTWARE
4) Install the floppy disks beginning with the first floppy disk. After completion of installation with the last PLC package floppy disk, key in "Q” to return the screen to the main menu.
[MAIN MENU] V4, 01 - A (ENG)
INSTALL
FR -INSTALL MD -INSTALL MAINTENANCE
~~ ~~
CLOSEDEV FR2H:
Erasing ... completed. Writing ... completed, Erasing ... completed. Writing ... completed.
G2 Toes
Please select anumber. (1/2/3/4) !_
5) Return the MODE toggle switch in the INSTALL frame at the UCMB in the “O” position.
6) lithe software cannot be installed by following the steps indicated above, the memory may have not been initialized. In this case, initialize the memory by following the steps explained in 5-2, “MD Initialization Processing”.
This completes the installation of the software. Load the backup data if necessary by following the steps explained in 5-5. “Loading the Backup Data”.
NOTICE : (1) Install the software in the order indicated in the floppy disk labels.
(2) Do not turn the power off while installing the software. If the power has to be turned off, install the software from the beginning again.
(3) After the completion of installation, always input “Q". The data is established by the input of “Q”. If the power is turned off before inputting “Q”, the CNC cannot start normally.
Page 188
4194-E P-177 SECTION 8 INSTALLING SOFTWARE
5-5. Loading the Backup Data
By loading the data and files backed up to the system backup floppy disk and the work disk to MDO: and MD1:, the previous state can be restored.
For the machine for which the software is installed for the first time, loading of the backup data is not necessary.
5-5-1. Backup Data Loading Procedure 1) Turn on the control power.
2) Place the CNC in the install mode. - Place the MODE toggle switch in the INSTALL frame at the UCMB in the “I” position. - Press the RESET switch.
- The following main menu of the install. mode is displayed.
[MAIN MENU] V4. 01 - A (ENG)
1. INSTALL
2. FR-INSTALL 3. MD -INSTALL 4. MAINTENANCE
INSTALL PROGRAM V4. 01-A (ENG) OKUMA 1997. 10. 31
Please select anumber. (1/2/3/4) !_
3) Select “4. MAINTENANCE”.
- The following maintenance tool menu is displayed.
[Maintenance tool ]
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration Replace 8. Initialize memory disk
System data store User file store ge ee IN
MAINTENANCE TOOL V1. 00 - A (ENG) OKUMA 1997. 10. 27
Please select anumber. (1/2/3/4/5/6/7/8) |_
Page 189
4194-E P-178
SECTION 8 INSTALLING SOFTWARE
4) Load the backed up system data.
5)
- Insert the system data backup floppy disk to the floppy disk drive.
- Select “4. System data store" from the maintenance tools and load the the instructions displayed on the screen.
system data by following
[Maintenance tool]
System data store User file store
BY, BeBe boss
~
Please select a number. (1/2/3/4/5/6/7/8) 14
Please press [WRITE] key after inserting a system backup floppy
(File name) <-(File name)
Stores of system data were completed.
Please select a number. (1/2/3/4/5/6/7/8) |_
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration Replace 8. Initialize memory disk
May system data of a floppy be stored on memory? (Y/N) lY
Load the user files.
- Insert the user file backup floppy disk to the floppy disk drive.
- Select “5. User file store” from the maintenance tools and load the user files by following the instructions displayed on the screen.
[Maintenance tool]
System data store User file store i aie ce
~~
Store of system data were completed.
Please select a number. (1/2/3/4/5/6/7/8) 15 Please press [WRITE] key after inserting auser File backup floppy.
(File name) <-(File name)
Stores of user files were completed, Please select a number. (1/2/3/4/5/6/7/8) |_
User file backup 6. Battery exchange preparation System data backup 7. Battery exchange restoration Replace 8. Initialize memory disk
May user files of a floppy be stored on memory? (Y/N) IY
Page 190
4194-E P-179 SECTION 9 CHANGING THE BATTERY
SECTIONS CHANGING THE BATTERY
If the battery has been used to the life, it is necessary to change the battery to the new one.
A battery is used to hold the contents in the memory disk and if it discharges completely, user files, system data and other information in the memory disk are lost.
The UCMB has a large-capacity capacitor (super capacitor) which holds the contents of the memory disk while the battery is changed; the capacitor is re-charged by turning the control power on.
When changing the battery, back up the user files and system data before disconnecting the battery so that they can be restored even when battery change is not successful.
NOTICE
: The capacitor can retain the disk memory data for one hour.
Change the battery within this period.
he Battery Life Warning
According to the status of battery voltage, three levels of warning messages are given.
(1)
Requiring Battery Change
The following message is displayed.
AAWARNNG : Alarm-D Memory board/battery change
(2)
When the battery use time reached the preset time, or if the battery voltage becomes lower than the specified voltage, this message is displayed.
lf this message is displayed, change the battery as soon as possible according to the procedure explained in 2 “Changing the Battery”.
Requiring Immediate Battery Change
The following message is displayed.
AAWARNING : Alarm-A Memory board/battery hurry exchange
(3)
This message is displayed if the battery has been kept used for 10 days since the display of the warning message indicated in (1).
lf this message is displayed, change the battery immediately according to the procedure explained in 2 “Changing the Battery”.
Battery Life and System Down
The following message is displayed.
AAWARNING] |: Aiarm-P Memory board/battery life
This message is displayed if battery voltage is lowered below the battery life voltage.
In this state, contents of the system data and the user files stored in the memory disk are not guaranteed. Even if they are backed up in the install mode, the contents of the backed up data cannot be guaranteed.
To restore the operation, install the control software after changing the battery then set the system data again.