Page 171 read from a scan by OCR; it may hold reading errors

4194-E P-160 SECTION 8 INSTALLING SOFTWARE

2-4.

2-5.

2-6.

2-7.

Package Floppy Disk Package floppy disk stores the software common to different machines.

Floppy disk is prepared for the individual functions.

System package

NC application package IGF-M package Option package (I-MAP, MOP-TOOL)

DNC package, etc.

Custom Floppy Disk

The custom floppy disk stores machine-dependent software, such as specification code file, control card file, user specification software file, and data file.

Two custom floppy disks are provided: - NC custom floppy disk - PLC custom floppy disk

System Backup Floppy Disk

The system backup floppy disk stores the backup data of the system data, which is specific to the individual machines. System data must be backed up in regular intervals.

When the machine is delivered, the system backup floppy disk stores the system data set before the shipping of the machine.

The system backup floppy disk is OSP format floppy disk.

Work Disk Work disk is a floppy disk where user's part programs should be stored before changing battery.

The work disk is OSP format floppy disk and should be prepared by the user.

Page 172 read from a scan by OCR; it may hold reading errors

4194-E P-161 SECTION 8 INSTALLING SOFTWARE

3. Media Necessary for Installing Software

3-1. | Control Floppy Disks

3-1-1. Kinds of Control Floppy Disks

(1) NC Custom Floppy Disk NC cusiom floppy disk stores the NC software specific to the individual machines.

** MNC CUSTOM FLOPPY ## <i/ > OSP DATE:1997-07-03 TYPE: MX45VA B601-3181-10

MNCU60100777-01

OSP SERIES

OKUMA CORPORATION

(2) Package Floppy Disks Package floppy disks are provided meeting the user’s machine specifications.

These floppy disks can be identified by labels.

** MNC PACKAGE FLOPPY #+ < 3/ > OSP SERIES TYPE: S/N: MNCA601A000-001

*# SYSTEM PACKAGE FLOPPY ## < 2/ > OSP SERIES TYPE: S/N: SYSEOOAJPN-001 nethe # of | HHH

# ## # # fete FH # HHH OSP SERIES # a ff # ## eHttt # # ##

OKUMA CORPORATION

Page 173 read from a scan by OCR; it may hold reading errors

4194-E P-162 SECTION 8 INSTALLING SOFTWARE

< Package floppy disks >

Label Contents SYSTEM PACKAGE FLOPPY NCOS Utility MCS firmware

FOS (PLC conirol software) PLC monitor software

MNC PACKAGE FLOPPY Machining center NC control software M MACMAN PACKAGE FLOPPY MacMan function NC alarm help message IGF-M PACKAGE FLOPPY IGF-M software M OPTION A/B PACKAGE FLOPPY I-MAP MOP-TOOL DNC PACKAGE FLOPPY DNC-P DNC-T/DT DNC-B/C

IGF-M PACKAGE FLOPPY, M OPTION A/B PACKAGE FLOPPY, and DNC PACKAGE FLOPPY are provided only when the corresponding specification is selected.

Page 174 read from a scan by OCR; it may hold reading errors

4194-E P-163 SECTION 8 INSTALLING SOFTWARE

(3) PLC Custom Floppy Disks PLC custom floppy disks store the PLC software specific to the individual machines.

+ MPLC CUSTOM FLOPPY ## ae ae OSP DATE: 1997-07-03 TYPE :MX45VA S/N:00777 B601-3181-10

MPCU60100777-01A

OSP SERIES

OKUMA CORPORATION

+# MPLC CUSTOM FLOPPY ## Cie, F OSP DATE: 1997-07-03 TYPE: MX45VA S/N:00777 B601-3181-10

MPCU60100777-01B

OSP SERIES

OKUMA CORPORATION

Page 175 read from a scan by OCR; it may hold reading errors

4194-E P-164 SECTION 8 INSTALLING SOFTWARE

3-1-2.

Configuration of Control Floppy Disks

(1)

Control Floppy Disks for the Standard Specifications

For the standard specifications, the following six floppy disks are provided.

++ MNC CUSTOM FLOPPY #+ (NC custom floppy disk)

< 1/

## SYSTEM PACKAGE FLOPPY ##

(system package floppy disk)

< 2/ 6>

** MNC PACKAGE FLOPFY ## (MNC package floppy disk)

< 8/ 6>

*# MACMAN PACKAGE FLOPPY ++

(MacMan package floppy disk)

< 4/ 6>

** MPLC CUSTOM FLOPPY ## (PLC custom floppy disk 1)

< 5/ 6>

+# MPLC CUSTOM FLOPPY ## (PLC custom floppy disk 2)

< 6/ &

Page 176 read from a scan by OCR; it may hold reading errors

4194-E P-165 SECTION 8 INSTALLING SOFTWARE

(2) Coniro! Floppy Disks for Optional Specifications

Configuration of Floppy Disks Floppy Disk Label (No,/Total: Printed at the upper right part of a label) [n = 6 to 10] NC CUSTOM 1/6 1/8 1/7 1/9 1/7 1/9 1/8 | 1/10 1/n FLOPPY SYSTEM PACKAGE 2/6 | 2/8 | 2/7 2/9 2/7 | 2/9 | 2/8 | 2/10 2/n FLOPPY LNC PACKAGE 3/6 | 3/8 3/7 | 3/9 3/7 | 3/9 | 3/8 | 3/10 3/n FLOPPY MACMAN PACKAGE | 4/6 | 4/8 | 4/7 | 4/9 | 4/7 | 4/9 | 4/8 | 4/10 4/n FLOPPY IGF-M PACKAGE 5/8 5/9 5/9 5/10 5/n FLOPPY 6/8 6/9 6/9 6/10 to (n-2)/n M OPTION 5/7 | 7/9 5/8 | 7/10 5/n PACKAGE FLOPPY to (n-2)/n DNC PACKAGE 5/7 | 7/9 | 6/8 | 8/10 5/n FLOPPY to (n-2)/n PLC CUSTOM 5/6 | 7/8 | 6/7 8/9 6/7 8/9 7/8 | 9/10 (n-1)/n FLOPPY 1 PLC CUSTOM 6/6 | 8/8 7/7 | 9/9 7/7 | 9/9 8/8 | 10/10 n/n FLOPPY 2

The order number is entered to the floppy disk label in the following rule. (1) The first floppy disk is the NC custom floppy disk. (2) The package floppy disks are from the second floppy disk to the third one from the last disk. (3) The last two floppy disks are PLC custom floppy disks.

If the total number of floppy disks supplied is “n", configuration of the floppy disks is as explained as below:

(1) The “1/n"th floppy disk is the NC custom floppy disk. (2) Package floppy disks are from the “2/n"th to the “(n-2)/n"th floppy disk. (3) PLC custom floppy disks are the “(n-1)/n"th and “n/n"th floppy disks.

Page 177 read from a scan by OCR; it may hold reading errors

4194-E P-166 SECTION 8 INSTALLING SOFTWARE

3-2. System Backup Floppy Disk

System backup floppy disk storing the system data set before the shipping of the machine is supplied with the control floppy disks.

## SYSTEM BACKUP FLOPPY ## OSP SERIES TYPE :MX45VA S/N:00777

OSP SERIES

OKUMA CORPORATION

3-3. Work Disk Work disks should be prepared by the user. Specification: 3.5 inches, 1.44 MB OSP format < OSP formatting procedure >

1) Press the [EDIT AUX] key on the NC operation panel to select the program operation mode.

2) Press [F2] (INIT), then input the following: = IN FDO:

3) Press the WRITE key. The following message will be displayed: input [Y] in response. = IN FDO: initialize OK (Y/N) ! ¥

4) Now the formatting message shown below will be displayed. Input [Y] in response. = IN FDO: initialize OK (Y/N) ! Y formatting (Y/N) ! Y

S) Now the format type message will be displayed. Input [1] in response. = IN FDO: initialize OK (Y/N) ! Y formatting (Y/N) ! Y format (2DD - 720K = 0, 2HD - 1.44 = 1)! 1

By the steps indicated above, the floppy disk is initialized in the OSP format.

Page 178 read from a scan by OCR; it may hold reading errors

4194-E P-167 SECTION 8 INSTALLING SOFTWARE

4, Steps for Installing Software

Installation of the software is divided into the following five steps. (1) Checking the hardware configuration (2) Initializing the MD (3) Back up of the data (4) Installing the software

(5) Loading the backup data

Page 179 read from a scan by OCR; it may hold reading errors

4194-E P-168 SECTION 8 INSTALLING SOFTWARE

5. Procedure for Installing Software

5-1. | Checking the Hardware Configuration

Check the hardware configuration related to the installation of software.

5-1-1. Checking the UCMB

(1)

Checking the Memory Size Check the memory size of: - Flash memory

- C-MOS memory

Checking the Connection of Backup Battery on UCMB The UCMB has the memory backup battery. Visually check if the battery is connected to the terminal (orange) extending from the board.

When installing the software for the first time, the battery may not be connected. In this case, connect the battery and initialize the memory disk following the steps explained in 5-2. “MD Initialization Processing”.

Page 180 read from a scan by OCR; it may hold reading errors

4194-E P-169 SECTION 8 INSTALLING SOFTWARE

5-2. MOD Initialization Processing

5-2-1. Cases Requiring MD Initialization Processing The MD must be initialized in the following cases, (1) Installing the software in the memory for the first time (2) Battery was not connected to the UCMB. (3) Contents of the MD have been lost diss to low backup battery voltage (4) Changing the MD card or configuration (5) MD card was removed from the UCMB,

Note: If the install mode cannot be established although the battery is connected to the UCMB, the software may have not been installed in the MD card and the MD card may have not been initialized. In this case, initialize the MD.

5-2-2. Procedure 1) Turn on the control power.

2) Place the CNC in the install mode. - Place the MODE toggle switch in the INSTALL frame at the UCMB in the “I” position. - Press the RESET switch.

a : XS-OFR INSTALL = em ! ' © woz O p aaa Sse | -232 a

- The jollowing main menu of the install mode is displayed.

[MAIN MENU] V4. 01 - A (ENG)

INSTALL

FR -INSTALL MD -INSTALL MAINTENANCE eS

INSTALL PROGRAM V4, 01-A (ENG) OKUMA 1997. 10. 31

Please select anumber. (1/2/3/4) !_