Page 161
4194-E P-150 SECTION 7 PLC PROGRAM INSTRUCTIONS
(2) [SFM257] Parity check
- The function module counts the number of ON bits in the input data and outputs whether the number of ON bits is even or odd.
4 HH FMC SFM257
DATA ’ WMo000 (number of digits to be checked)
i Sey (peer pete oe
+ DATA WI0001 (check data)
DATA 0.0002 (parity)
(3) [SFM258] Byte data transfer
- The function module transfers the higherfower bytes of the transfer source word data to the higher/lower bytes of the transfer destination word data.
higher/lower bytes)
DATA woo002 (transfer destination word)
4 nal FMC SFM258 H at DATA M.0000 (transfer source, if higher/lower bytes)
+ DATA WwI0001 (transfer source word) H
HL DATA M.0001 (transfer destination, +
Page 162
4194-E P-151 SECTION 7 PLC PROGRAM INSTRUCTIONS
(4) [SFM264] Alarm request
- The function module requests an alarm according to the alarm information given in an alarm block. It writes the return value to the alarm block.
FMC SFM264
DATA *LM0010 (start address of alarm block)
Data configuration of alarm block: The size of an alarm block is 16 bytes.
Start address, ~ (WMO000, etc.) (1) Alarm request bit
(2) Alarm number
(3) Object number
(4) Status of operation result
Total 16 bytes
+ - - (5) Alarm code, + - - - (6) Alarm character string,
Page 163
4194-E P-152 SECTION 7 PLC PROGRAM INSTRUCTIONS
(5) [SFM270] Revolving body control
- The function module judges the direction of rotation for shorter path control (if reverse rotation is possible).
- The function module returns the element number of the element appearing immediately before it or returns the number of elements appearing before the target is reached., H+ FMC - SFM270 H
DATA M.0050 (forward/reverse rotation flag) H
(position of element immediately before the target)
DATA WMo006
DATA WMoo000 (number of revolving body elements) + DATA WMO0001 (actual element position) fH + DATA wmo002 (target element position) H T, , (reverse rotation al Gar MiaSY possible/impossible flag) (designation of the position of DATA WMo004 element preceding the target element position)
(6) [SFM272] Code, bit development
- The function module develops the M or T code received as a number into irregular hexadecimal (M., K., etc.).
-
- FMC SFM272
DATA LMooo0o0 (identifier M. address)
DATA 256 (start of a numeric value to be developed)
developed)
DATA WG0259 (code to be developed)
Jee Se ee al DATA 272 (end of a numeric value to be
Page 164
4194-E P-153 SECTION 7 PLC PROGRAM INSTRUCTIONS
(7) [SFM275] M code development
- The function module develops the M code received as a number into internal memory of irregular hexadecimal (M.), referring to the M code configuration data (MC).
| J FMC SFM275 IF 4 DATA * WMo0000 (development type designation) 4 | DATA LMo002 (identifier MC address) H al DATA LMo004 (identifier M. address) H + DATA WG0259 (M code 1) H + DATA WG0273 (M code 2) L at DATA WG0274 (M code 3) + at DATA WG0275 (M code 4) [= at DATA WG0276 (M code 5) sia + DATA WG0277 (M code 6) te 4 Ll DATA WG0278 (M code 7) H mi DATA WG02749 (M code 8) + a DATA WMo0001 (status of operation result) H
Page 165
4194-E P-154 SECTION 7 PLC PROGRAM INSTRUCTIONS
(8) [SFM276] Logic table initialization - The function module initializes the logic table which is used for sequence control of ATC and APC.
- - HT FMC SFM276 H DATA WMo000 (control objective) + DATA LMOoOo01 (start address of logic data) a DATA Wmo002 (alarm number generated L internally) | DATA LMo0003 (alarm code generated internally) DATA LMoo04 (start address of diagnosis table) 4 DATA WM0005 (max. operation step number)
(9) [SFM277] Logic table control - The function module executes sequence control of ATC, APC, etc., - | 1 FMC SFM277
DATA WMo000 (contro! objective)
DATA WMo0001 (operation mode)
DATA WMo002 (operation step number)
DATA LM0004 (start address of output data)
DATA WMo0005 (A/B mode)
See a a ee ae SS ae
+ DATA LMo003 (start address of input data)
Page 166
4194-E P-155 SECTION 7 PLC PROGRAM INSTRUCTIONS
Sern Cb oe Se ce
DATA WMOo0006 bkochg diagnosis specific + DATA WM0007 (alarm number) + DATA | LMO008 (alarm code) b DATA M.0009 (solenoid ON flag) + DATA M.0010 fay operation completion + DATA yo ae iF DATA M.0013 (start position flag) H DATA M.0014 (in-cycle flag) + DATA M.0015 (test result) H DATA WMO016 (interlock code) +
Page 167
4194-E P-156 SECTION 7 PLC PROGRAM INSTRUCTIONS
(10) [SFM278] Magazine data calculation
- The function module calculates the actual pot number from the actual position (APA) of the magazine and the position command value (COM) from the pot number.
| i FMC SFM278 H + DATA - M.0000 (process mode) + + DATA LMo001 (position data) H DATA LMooo02 (pot-to-pot pitch, higher 4 bytes) DATA LMo003 (pot-to-pot pitch, lower 4 bytes) 4 DATA WMO0004 (pot number) 4 4 DATA WMo0005 (max. pot number) H
Page 168
4194-E P-157 SECTION 7 PLC PROGRAM INSTRUCTIONS
(11) [SFM279] Word table search
- The function module compares P1 to the upper one word in the table, where two words are arranged up and down in a pair, starting from address PO, and outputs the lower one word to P3 with “1” set to P4 if the upper one word agrees with P1. If the value of the upper word reaches value P2 in the state these words do not agree with each other, the function module sets “0” for P3 and P4, | FMC ‘SFM279 H 4 DATA LMo000 (table start address) i Re 4 DATA WMO0001 (comparison data) Tt 4 DATA Wmo002 (table end data) H | DATA WMO0003 (data to be fetched) + Hf DATA M.0004 (search result) H
Page 169
eo =, - - - =, i
"
4194-E P-158 SECTION 8 INSTALLING SOFTWARE
SECTIONS INSTALLING SOFTWARE
1. Outline of Install
This section deals with the procedure for installing the software.
Points to be taken into consideration for this operation are shown below: (1) Flash memory and C-MOS memory are used for the main memory.
(2) Software is provided in package floppy disks and custom floppy disks.
Package floppy disks ......... Floppy disks storing the software common to different machines - NC application software - |-MAP, etc.
Custom floppy disks .......... Floppy disks storing machine-specific software - Specification code file - Option software - PBU file, etc.
Page 170
4194-E P-159
SECTION 8 INSTALLING SOFTWARE
2: Glossary of Technical Terms
2-1. | Flash Memory (FR)
Flash memory stores the control program files such as .SYS, .POL, *.MSG, and *.LOB.
Flash memory is divided into the following partitions when the software is installed.
< Partition of flash memory >
Partition Installed Software
FROA: NCOS, MCS firmware, FOS (PLC conirol software), utility
FROB: MacMan software
FROC: NC control software
FROD: IGF-M
FROE: I-MAP, MOP-TOOL
FROF: DNC-P, DNC-T, DNC-DT, TCP/IP firmware, SCCI firmware, CCP firmware
FROG: PLC monitor software
FROH: Super Hi-NC
FR1IC: NC specification code data, control card data, MSB NC specification message, user-specific software
FR1H: NC help message
FR2G: Sequence program
FR2H: Sek screen data, PLC alarm message, PLC help message, system |/O data, logic table ata
2-2. Memory Disk (MD) C-MOS memory area is called memory disk.
It stores the user’s part programs and backup data files (*.PBU).
The memory disk is divided into the following partitions when the software is installed.
< Partitions of memory disk >
Partition Installed Software MDOA: (MDO:) NC data file, MacMan data, PLC monitor data MDOC: IGF-M, I-MAP data, DNC data, MOP-TOOL data MDOE: PLC variable data, PLC constant data, MCS data, PLC axis data, M code data MDOG: MDOH: (MD1:) User’s part programs, etc.
2-3., Install
“Install” means the operation to store the control software in the FR or MD.
NOTICE | |: