Pages from an Omron SYSMAC C200H catalog, behind a reseller cover sheet, on the C200H backplanes C200H-BC031-V2, C200H-BC051-V2, C200H-BC081-V2 and C200H-BC101-V2. It shows how a backplane is used for CPU, expansion I/O and slave racks and which power supplies, cables and modules make up a C200H system.

Type
5-slot backplane for the Omron SYSMAC C200H system p. 1, 4
Rack uses
CPU racks, local expansion racks and remote expansion (slave) racks p. 2, 4
Right-most slot
Holds the CPU, the power supply (local expansion racks) or the SYSMAC BUS remote slave/power supply p. 2
Remote rack power
Built into the SYSMAC BUS remote slave modules p. 2
Family sizes
3, 5, 8 and 10 I/O slots: C200H-BC031-V2, C200H-BC051-V2, C200H-BC081-V2, C200H-BC101-V2 p. 2
Expansion I/O racks
Up to two per CPU rack p. 3
I/O connecting cable
CPU rack to expansion I/O racks; 0.3, 0.7, 2, 5 and 10 m lengths p. 3
I/O power supplies
100/200 VAC: C200H-PS221; 24 VAC: C200H-PS211 p. 3
Slave racks
Up to five per CPU rack, by optical or wire cable to a Remote I/O Master Module p. 3
Remote I/O slave modules
100/200 VAC: C200H-RT001-P (optical), C200H-RT201 (wired); 24 VAC: C200H-RT002-P (optical), C200H-RT202 (wired) p. 3

What this manual walks you through

  • Choosing a C200H backplane by number of slots p. 2
  • Building CPU, expansion I/O and slave racks p. 3
  • I/O and special I/O modules that mount on the backplanes p. 4

Good to know

  • The interrupt function of the C200HS-INT01 works only on the CPU rack, and only one such module can be used with a CPU. p. 3

Questions this manual answers

How many slots does the C200H-BC051-V2 have?

It is the 5-slot backplane of the C200H range, which also comes in 3, 8 and 10 slot sizes. p. 1, 2

Where does the CPU go on a C200H backplane?

The CPU, the power supply of a local expansion rack, or the remote slave/power supply mounts in the right-most slot. p. 2

Can the C200H-BC051-V2 be used for an expansion rack?

Yes. The same backplanes are used for CPU, expansion I/O and slave racks. p. 2, 4

How many expansion racks can a C200H CPU rack have?

Up to two expansion I/O racks, plus up to five slave racks through Remote I/O Master Modules. p. 3

The file

Size and text

Pages4
PDF450 KB
TextText from the PDF itself.

Every page · 4

Read it here

The words of each page, so a phone can search and copy them. The pages themselves are in the PDF.

The text of page 1, from the PDF itself

OMRON

SYSMAC - System C200H Backplanes

C200H-BC051-V 5-slot Backplane

Presented by - MRO Electric and Supply Company, Inc. For Product Needs:

Email: sales@MROELECTRIC.COM Call:

1-800-691-8511

Fax: 919-415-1614

http://www.MROELECTRIC.com/

OMRON System C200H

MRO ELECTRIC & SUPPLY Company

mroelectric.com

The text of page 2, from the PDF itself

C200H-series Backplanes

Backplanes1CH2CH0CHC200H-BC031-V21CH2CH3CH2CH3CH4CHC200H-BC051-V24CH5CH6CH7CHC.0CH1CHCO M0CHC200H-BC081-V21CH2CH3CH4CH5CH6CH7CH8CH9CHEL EC TRI0CHC200H-BC101-V2C200H Backplanes

Number of slots 3 slots 5 slots 8 slots 10 slots

Part number C200H-BC031-V2 C200H-BC051-V2 C200H-BC081-V2 C200H-BC101-V2

M

RO

These C200H Backplanes are used for CPU Racks, Local, and Remote Expansion Racks. They are available with 3, 5, 8, and 10 I/O slots. The power supplies for these racks are built into the SYSMAC BUS Remote Slave Modules. The CPU, Power Supply (for Local Expansion Racks), or SYSMAC BUS Remote Slave/Power Supply mounts in the right-most slot of the Rack.

1

1

The text of page 3, from the PDF itself

System ConfigurationCPU RacksCommunications ModulesCPUs

SYSMAC Link Modules C200HS-SLK12/22

C200HS-CPU31 SYSMAC Net Modules C200HS-SNT32

8-slot Rack (Example)

100/200 VAC: 24 VAC
CO M

CPUs with Communications

C200HS-CPU31-E C200H-CPU31-E C200HS-CPU33-E

Link ModulesC200H-CN 1CPU MemoryExpansion I/O Racks

C200H-MR C200H-ME 1 C 2 0 0 H- ME 2

EPROM E E P ROM

C200HS-MP16K C200HS -ME16K

I/O Power Supplies

8-slot Rack (Example)

Up to two Expansion I/O Racks can be connected to each CPU Rack.

RO

100/200 VAC: C200H-PS221 24 VAC: C200H-PS211

MSlave RacksRS-232C: C200HLK201-V1

Remote I/O Master Modules PC Link Modules

C200H RAM EPROM E E P ROM C200HS

EL EC T

Connects the CPU Rack to one or more Expansion I/O Racks. Cables are available in 0.3, 0.7, 2, 5 and 10 m lengths.

RS-422: C200HLK202-V1

RI

Connect with C200H-CN L1 i I/O Connecting Cable

Host Link Modules Optical: C200HLK101-PV1

C.

C200HS-CPU21-E Standard CPUs 100/200 VAC: C200HS-CPU01/21-E C200H-CPU01/21-E 24 VAC: C200HS-CPU03/23-E C200H-CPU03/23-E

C200H-RM201 C200H-RM001 C200H-LK401

Interrupt Input Module The interrupt function of this Module is available only when it is mounted to the CPURack (see note). When mounted to an Expansion Rack, the Module can be used only as a Standard I/O Module. C200HS-INT01

High-Density I/O Modules (Group-2 Modules) Input Modules 32 points

64 points

Remote I/O Slave Modules FUSE

C 2 0 0 H - I LILILILI L1 L2/N

Output Modules

8-slot Rack (Example)

One or more Slave Racks can be connected via optical or wire cable to a Remote I/O Master Module mounted on either a CPU or Expansion I/O Rack. Up to five Slave Racks can be connected per CPU Rack.

32 points

100/200 VAC Optical: C200H-RT001-P Wired: C200H-RT201

64 points

C 2 0 0 H - OLILILILI

24 VAC Optical: C200H-RT002-P Wired: C200H-RT202

Note: Only one Interrupt Input Module can be used with a CPU.

1 9

The text of page 4, from the PDF itself

System Configuration

I/O Modules

Analog Input Modules Analog Output Modules

I nput Modules (C200H-I LILILILI)

8 points C200H-AD001/002 C200H-DA001 Temperature Sensor Modules

16 points

Backplanes The same Backplanes are used for CPU, Expansion I/O, and Slave Packs.

CO MSpecial I/O Modules3-slot Backplane

(AC, DC, AC/DC, transistor inputs)

0CH

Temperature Control Modules

1CH2CHC200H-BC031-V2C200H-TS LILILIC200H-TCLILILIFuzzy Logic ModulePID Control ModulesC.

32 points (Treated as Special I/O Module) Output Modul es (C200H-OLILILILI)

5-slot BackplaneC200H-PIDLILI1CH2CH3CH4CH12 pointsEL EC T

C200H-FZ001 High Speed Counter Modules

RI0CH5 points 8 pointsC200H-BC051-V2

Position Control Modules

16 points 32 points (Treated as Special I/O Module)

DC Input/Transistor Output Modules C200H-MDLILILI (16 inputs and 16 outputs; treated as Special I/O Module.)

C200H-CTLILILI Cam Position Modules

C200H-NCLILILI0CH1CH2CH3CH4CH5CH6CH7CHID Sensor ModuleROB7A Interface ModulesC200H-IDSLILIMC200H-CP1148-slot Backplane

ASCII Module Voice Module

16 points Input

C200H-BC081-V2

16 points Output C200H-B7AI1 C200H-B7AO1

Analog Timer Module10-slot Backplane 0CH1CH2CH3CH4CH5CH6CH7CH8CH9CHC200H-BC101-V2

C200H-ASC02 C200H-OV001

8C200H-TM0012