Page 164
Glossary Programmable Controller
A small, computer-like device that can control peripheral equipment, such as an electric door or quality control devices, based on programming and peripheral input devices. Any process that can be controlled using electrical signals can be controlled by a PC. PCs can be used independently or networked together into a system to control more complex operations.
programming device
A peripheral device used to write programs and to input a program to a PC or to alter or monitor a program already stored in the PC. There are dedicated programming devices, such as Programming Consoles, and there are nondedicated programming devices, such as a host computer.
PROM
[P(rogrammable) R(ead) O(nly) M(emory)] A type of ROM into which the program or data may be written after manufacture, by a customer, but which is fixed from that time on.
PROM Writer
A PROM Writer is a device used to write data to ROM, PROM, and EPROM storage chips.
Proximity Switch
A switch that uses magnetic induction to measure the distance of a metallic object from the front of the switch.
Rack PC
A PC that is composed of Units mounted to one or more Racks. This configuration is the most flexible, and most large PCs are Rack PCs. A Rack PC is the opposite of a Package-type PC, which has all of the basic I/O, storage, and control functions built into a single package.
RAM
[R(andom) A(ccess) M(emory)] RAM will not retain data when power is disconnected. Therefore data should not be stored in RAM.
register/registered
Storing text and graphics in the RAM/ROM card from a personal computer or the ASCII Unit. Graphics that have been written to the RAM/ROM card are referred to as registered messages.
Remote I/O Unit
A Unit that extends the distance an Expansion I/O Unit can be from the CPU.
ROM
[R(ead) O(nly) M(emory)] A type of digital storage that cannot be written to. A ROM chip is manufactured with its program or data already stored in it, and it can never be changed. However, the program or data can be read as many times as desired.
switching capacity
The voltage/current that relay can switch ON and OFF.
stepping motor
An output device that rotates according to signals from the Control System. The rotation is very precise and occurs in pre-defined “steps”.
switch
An input device that sends either an ON or OFF signal to the Control System. A switch can be operated either by a person or by the movement of a piece of equipment or material.
system configuration
The arrangement in which Units in a System are connected. This term refers to the conceptual arrangement and wiring together of all the devices needed to comprise the System. In OMRON terminology, system configuration is used to describe the arrangement and connection of the Units comprising a Control System that includes one or more PCs.
150
Page 165
Glossary Unit
In OMRON PC terminology, the word Unit is capitalized to indicate any product sold for a PC System. though most of the names of these products end with the word Unit, not all do, e.g., a Remote Terminal is referred to in a collective sense as a Unit. Context generally makes any limitations of this word clear.
watchdog timer
A special timer inside the CPU that monitors the PC’s cycle time. The watchdog timer sets a flag if the cycle time becomes longer than a certain specified value. This is useful if the correct operation of your System depends on a certain maximum cycle time.
word
In digital circuits, a group of bits. Usually a word consists of four, eight, or sixteen bits. In C-series PCs, a word consists of sixteen bits. Words can be used to store data, or they can be used for I/O.
work bits
Bits in the IR area that are not being used for input or output. These bits can be used in the program in any way desired.
151
Page 166
Page 167
Index A-B Assembly backplane, , connecting cable, CPU, Expansion I/O Unit, I/O Units, mounting the Units, Backplane, IR word allocation, , Backplane Insulating Plates, Battery, Memory Packs, replacement,
C C200H-CPU1 1 battery, replacement, power consumption, calculation examples, Cables, control components, Control System, Cooling clearance between Racks, cooling fan, CPU, C200H-CPU01/03, C200H-CPU1 1, indicators, Peripheral Device Connectors, cable connection, direct mounting, wiring, CPU Rack, Current consumption 24-V supply, 26-V supply, 5-V supply, calculation examples, cycle, cycle time,
D-E Duct work I/O wiring, power cables, electrostatic charge, Emergency stop circuit, Expansion I/O Rack,
F-H factory computer, Fuse CPU and power supply, replacement, Output, replacement, Output Units, Grounding ground terminal, line ground terminal, wire, humidity,
I-L I/O Devices, connections, I/O points, calculating the number of, I/O Unit Cover, I/O Units, A-shape, B-shape, connections, E-shape, input devices, installation, environment, ambient conditions, Insulating plates, IR word allocation, work bits, Limit Switch,
M Memory Packs assembly, battery failure flag, EEPROM chip, EEPROM Pack, EPROM chip how to mount, mounted to the printed circuit board, EPROM Pack, how to mount to CPU, RAM Pack, switches, Mounting requirements, DIN Rail mounting, 16-mm DIN Rail, 7.3-mm DIN Rail, DIN Rail mounting bracket, procedure,
153
Page 168
Index
N-O
S
Noise cables, I/O wiring,
Sequential circuit (for power failure), output devices, servomotors,
Output Units, external fuse,
Solenoid,
Servomotor, servomotor drivers,
Special I/O Units, Remote I/O Slave Rack,
P PC block diagram, flow chart, operation, role of, Photoelectric Switch, Power source, wiring, Power supply, AC power supply, DC power supply, wiring, precautions, general, process control computer, Programming Console, Hand–held, static electricity, preventing, stepping motor, system configuration, System Configurations, Expansion I/O Racks, Host Link Unit, I/O Connecting cable, Memory Packs, Optical Fiber Cable, Remote I/O Master Unit, Remote I/O Slave Unit, Special I/O Units, Standard I/O Units, SYSMAC Link Unit,
T Terminal block, terminal block, wiring,
Proximity Switch,
R Relay, printed circuit board, Relays, Output Unit, replacement, Remote I/O, PC Link Units, Special I/O Units, word allocation,
154
W Wiring AC Input Units, DC Input Units, examples, I/O devices, I/O Units, terminal blocks, word allocation, for expanded PC, work bits,
Page 169
Revision History
A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. W111-E1-10 Revision code
The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code 6
Date July 1989
Revised content Corrections to pages: 3, 6, 16 to 18, 21, 23, 26, 27, 31, 32, 33, 41, 51, 52, 53, 57, 58, and 60.
7
February 1990
Entire manual reorganized and reproduced.
8
October 1990
8A
May 1991
Revision of text and inclusion of new product information (C200H-CPU11-E, SYSMAC NET, SYSMAC LINK, C200H-OC225, and C200H-OD212) Corrections to pages: 7, 10, 12, 13, 15, 16, 23, 27, 28, 34 to 39, 61, 63, 64, 82, 85, 94, 97 to 100, 103, 104. Pages 33 to 38: Completely redone. Page 102: Backplane model numbers revised. Page 103: BC031-V1 and BC101-V1 added to note at bottom of page. Page 104: Microwave ID Sensor and Analog I/O Units added. Page 110: Terminal Resistor and Power Supply Adapter model numbers revised. The manuals has also been reformatted, changing page numbers slightly.
8B
May 1992
8C
December 1993
Page 7: PC Operation Flowchart redone. Page 27: The section reference in the second line corrected to Section 2-6 Memory Packs. Page 28: “Optical Fiber Cable” in the lower left corner corrected to “Optical Fiber Cable or Wire Cable”. Pages 113 to 128: The following instructions are missing from Appendix E Programming Instructions: LMSG(47), TERM(48), SYS(49), CMPL(60), CTW(63), WTC(64), HTS(65), STH(66), VAL(69), SEND(90), and RECV(98). (These instructions were originally added in revision 8, but inadvertently omitted from revision 8A.) Multipoint I/O changed to High-density I/O throughout the manual. Scan time changed to cycle time throughout the manual. Page 10: Model number corrections made in the first paragraph of CPU. Page 28: Reference corrected for SYSMAC NET Link Unit and SYSMAC LINK Unit. Page 32: Table updated. Page 33: Note added, 1.4 V corrected to 1.4 A in the top table. Pages 34, 35: Models added and updated. Page 37: Calculation of power consumption corrected. Page 38: I/O Unit Cover description added. Page 42: Ambient conditions added. Page 79: “8 A/Unit” in Terminal Connections changed to “16 A/Unit”. Page 82: Max. switching capacity changed. Page 92: B7A Interface Unit specifications added. Pages 97 to 105: Appendix C completely updated.
155
Page 170
Revision History Revision code
Date
Revised content
9
February 1999
References to C200H-OA221 removed throughout the manual. Pages 10, 23, 27, 31, 34, 92: C200H-OD21A added. Pages 10, 23, 27, 31, 82, 84: Backplane model information corrected. Pages 13, 19, 23, 63, 98. 99: Added information on E-shape I/O Units. Page 18: Number of terminals for B-shape I/O Units corrected. Pages 34: Model numbers of SYSMAC LINK and SYSMAC NET Link Units changed. C200H-OA224 added. Pages 34, 66: C200H-IA222V added. Pages 34, 76: C200H-OA222V added. C200H-OA222 removed. Pages 34, 78: C200H-OA122-E added. C200H-OA224/OA223 added. Pages 35: Analog I/O Units added/corrected. Pages 39 to 40: Precautions for connecting DC two-wire sensors added. Page 41: Caution added. Page 57: Fuse specifications table added. Pages 60, 61: Added step to procedures. Page 63: Power consumption and dielectric strength corrected, and surge current added. Pages 73 to 76: Specifications for C200H-ID218 and C200H-ID219 DC Input Units added. Page 77: Circuit configuration corrected for C200H-OA121-E. Pages 84, 85: Circuit configurations changed for C200H-OD212 and C200H-OD213. Pages 95, 96: B7A Interface Unit information modified. Page 99: Insulation plate mounting dimensions corrected. Pages 100 to 111: Standard models list updated.
10
January 2001
Page xii: Minor change made to last caution. Page xiii: Changes made to wording of information on grounding and mounting. Pages 16, 17: Minor changes made to graphics. Page 17: Information on LG and GR terminals added. Page 19: “Pack” changed to “Unit” in several places. Information on Memory Units added. Page 37: Minor change to last sentence. Pages 51, 52: Information on power supply wiring added. Page 63: S.I. data replaced with metric equivalent.
156
Page 171
Page 172
OMRON.
OMRON ELECTRONICS LLC
1 Commerce Drive Schaumburg, IL 60173 847.843.7900
For US technical support or other inquiries: 800.556.6766
MRON CANADA, INC.
885 Milner Avenue Toronto, Ontario M1B 5V8 416.286.6465
OMRON ON-LINE
Global - http:/Mwww.omron.com USA - http:/Awww.omron.com/oei Canada - http://www.omron.ca
UNITED STATES
To locate a Regional Sales Office, local Distributor or to obtain product information, call: 847.843.7900
CANADA REGIONAL SALES OFFICES
Ontario Toronto 416.286.6465 Kitchener 519.896.1144 Kingston 613.376.3968
Quebec Montreal 514.636.6676
British Columbia Vancouver 604.522.8855
Alberta Edmonton 403.440.0818 Calgary 403.257.3095
Sao Paulo 55.11.5564.6488
Cono Sur 54.114.787.1129
Florida 954.227.2121 Ciudad Juarez 656.623.7083
Mexico, D.F. 555.534.1195 | Monterrey,N.L. 818.377.4281
W111-E1-10 ©2006 OMRON ELECTRONICS LLC Printed in the U.S.A.
Specifications subject to change without notice.
Page 173