Manual · Omron
SYSMAC Programmable Controllers C200H (CPU01-E/03-E/11-E) Installation Guide
Manual173 pagesPDF 1.3 MB
Installation guide for the Omron SYSMAC C200H programmable controller with the CPU01-E, CPU03-E and CPU11-E CPUs.
Covers · 1 model
The models it covers
Summary
What is in it
Omron's installation guide for the C-series C200H programmable controller (CPU01-E/03-E/11-E). It introduces programmable controllers, describes the CPU rack, CPU, expansion I/O racks, power supplies, I/O units and memory units, then explains assembly, I/O word allocation and remote I/O, installation environment and noise prevention, grounding and wiring, and safety circuits. Appendices cover inspection and maintenance, specifications, standard models, Programming Console operation and programming instructions.
Its parts
- Precautions
- Introduction
- Description
- Assembly Instructions
- System Connections
- Installation Environment
- Power Considerations
- Safety Considerations
- Inspection and Maintenance
- Specifications
- Standard Models
- Programming Console Operation
- Programming Instructions
- Glossary
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Omron installation guide W111-E1-10 for the SYSMAC C200H programmable controller, covering the C200H-CPU01-E, CPU03-E and CPU11-E CPUs. It describes the CPU, racks, power supplies, memory and I/O units, then walks through assembly, power wiring, grounding, the installation environment and routine maintenance. Appendices give specifications and standard model numbers.
- Device
- Rack-type programmable controller CPU, in three models: C200H-CPU01-E, C200H-CPU03-E, C200H-CPU11-E p. 25, 121
- Supply voltage
- C200H-CPU01-E and C200H-CPU11-E: 100 to 120 or 200 to 240 VAC; C200H-CPU03-E: 24 VDC p. 25
- Operating voltage range
- C200H-CPU01-E, CPU11-E: 85 to 132/170 to 264 VAC; C200H-CPU03: 20.4 to 26.4 VDC p. 79
- Power fuse
- C200H-CPU01-E, CPU11-E: 2 A 250 V, 5.2 dia. x 20 (MF51NR); C200H-CPU03: 2 A 125 V p. 26, 79
- Program capacity
- 6,974 words with 8K-word memory p. 80
- I/O bits
- 480 (00000 through 02915) p. 80
- Memory Units
- EPROM C200H-MP831; EEPROM C200H-ME431, C200H-ME831; RAM C200H-MR431, C200H-MR831, C200H-MR432, C200H-MR832 p. 33
- Battery Set
- C200H-BAT09, for C200H RAM Memory Unit only p. 125
- Ambient temperature
- 0 to 55°C operating (0 to 45°C for Programming Console); -20 to 65°C storage p. 79
- 24 VDC output
- C200H-CPU01-E, CPU11-E: 0.3 A at 24 VDC +10%/-20%; C200H-CPU03: none p. 79
- Timers/counters
- 512 (TIM/CNT 000 through 511) p. 80
- Humidity
- 35 to 85% RH without condensation p. 79
- I/O Connecting Cables
- C200H-CN311, C200H-CN711, C200H-CN221, C200H-CN521, C200H-CN131; 12 m maximum total length p. 121
- Backplanes
- C200H-BC101-V2, C200H-BC081-V2, C200H-BC051-V2, C200H-BC031-V2 (10, 8, 5 or 3 slots) p. 121
What this manual walks you through
- Identifying CPU parts and front-panel indicators p. 25, 26
- Mounting a Programming Console directly on the CPU p. 27
- Choosing a Memory Unit and setting its write-enable and start-mode switches p. 33, 34
- Keeping rack units within power supply current limits p. 49
- Choosing an installation site and spacing the racks p. 60
- Mounting racks vertically, optionally on DIN rail p. 61
- Grounding the PC and wiring an emergency stop circuit p. 66
- Wiring the AC power supply and selecting the supply voltage p. 67
- Replacing CPU, power supply and output unit fuses p. 73
- Replacing the RAM battery set p. 77
Good to know
- SYSMAC LINK and SYSMAC NET Link Units work only with the C200H-CPU11-E. p. 25
- A battery replacement must be finished within five minutes or the data may be lost. p. 77
- Do not run a dielectric strength test on the 24 VDC C200H-CPU03-E, PS211, RT002-P or RT202 Units. p. 79
- Power interruptions of 10 ms or less are ignored; a drop below 85% of rated voltage for over 25 ms stops the PC and turns outputs off. p. 67
- An emergency stop must be an external relay circuit; a stop routine in the program is not enough. p. 66
Questions this manual answers
What supply voltage does the C200H-CPU01-E use?
100 to 120 VAC or 200 to 240 VAC. Short the voltage selector terminals with the supplied bracket for 100 to 120 VAC, or leave them open for 200 to 240 VAC. p. 25, 67
What is the replacement battery for a C200H RAM Memory Unit?
The manual lists the C200H-BAT09 Battery Set, for the C200H RAM Memory Unit only. p. 125
Can the C200H-CPU01-E connect a SYSMAC LINK or SYSMAC NET Link Unit?
No. Only the C200H-CPU11-E has the connector for those link Units. p. 27
What does BATT FAIL on the C200H Programming Console mean?
The battery is nearly discharged and the ALARM indicator blinks. Replace the battery within one week to avoid losing data. p. 77
What does a blinking red ALARM light on a C200H CPU mean?
An error has occurred that does not stop the CPU. A solid red ERROR light means an error that stops the CPU and turns the outputs off. p. 26
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 18 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Sysmac Programmable Controllers C200H (CPU01-E/03-E/11-E)1-3
- Pages 4 to 134-13
- Pages 14 to 2314-23
- Pages 24 to 3324-33
- Pages 34 to 4334-43
- Pages 44 to 5344-53
- Pages 54 to 6354-63
- Pages 64 to 7364-73
- Pages 74 to 8374-83
- Pages 84 to 9384-93
- Pages 94 to 10394-103
- Pages 104 to 113104-113
- Pages 114 to 123114-123
- Pages 124 to 133124-133
- Pages 134 to 143134-143
- Pages 144 to 153144-153
- Pages 154 to 163154-163
- Pages 164 to 173164-173
The file