SYSMAC Programmable Controllers C200H (CPU01-E/03-E/11-E) Installation Guide, pages 74 to 83

Pages 74 to 83 of 173

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron C200H-CPU01-E

Page 74

Appendix A

Inspection and Maintenance 1, 2, 3...

1. Turn OFF the power to the PC. 2. Detach the terminal block by unlocking the lock levers at the top and bottom of the terminal block. 3. While pushing down the lock lever on the Backplane with a screwdriver as shown below, remove the Output Unit.

4. Remove the screw from the top of the Unit (Phillips screwdriver). 5. Detach the case from the Unit (flat-blade screwdriver).

6. Pull out the printed circuit board. 7. Insert a new fuse. A spare fuse is provided inside the rear of the case when the Unit is delivered. 8. Reassemble in reverse order of assembly.

Output Unit Relays To replace a Relay, follow the steps below:

1, 2, 3...

1. Turn OFF the power to the PC. 2. Detach the terminal block by unlocking the lock levers at the top and bottom of the terminal block.

60

Page 75

Appendix A

Inspection and Maintenance

3. While pushing down the lock lever on the Backplane with a screwdriver as shown below, remove the Output Unit.

4. Remove the screw from the top of the Unit (Phillips screwdriver). 5. Detach the case from the Unit (flat-blade screwdriver).

6. Pull out the printed circuit board. The Relays are placed on the PC boards of individual Units as shown in the figures below.

OC221/OC224

0 1 2 3 4 5 6 7

61

Page 76

Appendix A

Inspection and Maintenance

OC222

0 1 2 3 4 6 8 10

5 7 9 11

OC223

0 1 2 3 4

OC225 8 9 10 11 12 13 14 15

0 1 2 3 4 5 6 7

7. A Relay puller is provided inside the rear of the case when the Unit is delivered. Use the Relay puller to pull out the Relay as shown below. Insert a new Relay.

Relay puller Using the Relay puller, pull the relay up and out of the socket.

Printed circuit board

8. Reassemble in reverse order of assembly.

62

Page 77

Appendix A

Inspection and Maintenance

Batteries Some RAM Packs use a battery (refer to Appendix B for specifications). When the battery is nearly discharged, the ALARM indicator blinks and the message “BATT FAIL” appears on the Programming Console. When this occurs, replace the battery within one week to avoid loss of data. The battery comes together with its connector as a set. To replace the Battery Set, follow the steps below. The entire replacement must be completed within five minutes to ensure that the data will not be lost. If you are using model C200H-CPU11-E as the CPU, the battery is installed in the Unit upon delivery.

1, 2, 3...

1. Turn OFF the power to the PC. (If the power was not already ON, turn the power ON for at least one minute before turning the power OFF.) 2. Remove the cover from the battery compartment of the RAM Pack. 3. Remove the old Battery Set. 4. Install the new Battery Set as shown shown in the following diagram.

Battery connector Battery Set

5. Replace the cover of the battery compartment. 6. Press CLR, FUN, MONTR, MONTR or just turn the power to the PC OFF and then ON again to clear the error message on the Programming Console.

63

Page 78

This page is a scan with no text; see it in the PDF.

Page 79

Appendix B Specifications

The following series of figures and tables provides a complete set of specifications for each Unit of the C200H. Note that I/O Units may take on one of three different shapes. Thus I/O Units are sometimes referred to as A-shape I/O Units, B-shape, or E-shape I/O Units. Refer to the figures at the end of the I/O Unit specifications for the exact dimensions of these three shapes of I/O Unit.

General Specifications Item

C200H-CPU01-E, CPU11-E/PS221

C200H-CPU03/PS211

Supply Voltage

100 to 120/200 to 240 VAC selectable 50/60 Hz

24 VDC

Operating Voltage Range

85 to 132/170 to 264 VAC

20.4 to 26.4 VDC

Power Consumption

120 VA max. per Rack (Backplane)

40 W max. per Rack (Backplane)

Surge Current

Approx. 5 times the normal current

Output Capacity

CPU Rack: 3 A 5 VDC (1.6 A supplied to I/O Units) Refer to Section 4-4 Special Considerations for C200H-CPU11 Expansion I/O Unit Rack: 3 A 5 VDC (2.7 A supplied to I/O Units)

Fuse

2 A 250 V 5.2 dia. x 20 (MF51NR)

2 A 125 V 5.2 dia. x 20 (MF51NR)

24 VDC Output

0.3 A 24 VDC +10%/–20%

None

Dielectric Strength

2,000 VAC 50/60 Hz for 1 minute between See Caution. AC terminals and housing 500 VAC 50/60 Hz for 1 minute between DC terminals and housing leakage current: 10 mA max. 1,000 Vp-p, pulse width: 100 ns to 1 ms, rise time: 1 ns

Noise Immunity Vibration

Mechanical durability: 10 to 35 Hz, 1 mm double amplitude (24.5 m/s2) in X, Y, and Z directions, for 2 hours each (When mounted on DIN Rail, 16.7 Hz, 1 mm double amplitude (4.9 m/s2) in X, Y, and Z directions, for 1 hour each) Malfunction durability: 2 to 55 Hz, 19.6 m/s2, in X, Y, and Z directions, for 20 minutes each (When mounted on DIN Rail, 2 to 55 Hz, 2.94 m/s2, in X, Y, and Z directions, for 20 minutes each)

Shock

98 m/s2 in X, Y, and Z directions, 3 times each

Ambient Temperature

Operating: 0° to 55°C (0° to 45°C for Programming Console) Storage: –20° to 65°C

Humidity

35 to 85% RH (without condensation)

Atmosphere

Must be free of the following: • Corrosive gases • Abrupt temperature changes • Direct sunlight • Dust, salt, or metal filings • Water, oil, or chemicals

Grounding

Less than 100 W

Degree of Protection

Mounted in a panel

Weight

6 kg max.

! Caution

When conducting an insulation resistance or dielectric strength test, disconnect the power supply terminals from the LG and GR terminals. Do not conduct a dielectric strength test on the C200HCPU03-E, PS211, RT002-P, or RT202 Units. The power supply input line and internal circuit of the 24 VDC Power Supply are not isolated from each other. If a dielectric strength test is conducted, the Power Supply will be damaged.

65

Page 80

Appendix B

Specifications

CPU Specifications Main Control Element

MPU, CMOS, LS-TTL

Programming Method

Ladder diagram

Instruction Length

1 address/instruction, 1 to 4 words/instruction

Number of Instructions C200H-CPU11

145 (12 basic instructions + 133 special instructions) 159 (12 basic instructions + 147 special instructions)

Execution Time

Basic instructions: 0.75 to 2.25 ms

Memory Capacity

6,974 words (with 8k-word memory)

I/O bits

480 (00000 through 02915)

I/O Units mounted Special I/O Units to Remote I/O Slave 1,600

Optical I/O Units and I/O Terminals 512

IR bits

3,296 (03000 through 23515)

Racks 800 (05000 through 09915)

(20000 through 23115)

SR bits

312 (23600 through 25507)

TR bits

8 (TR 0 through 7)

HR bits

1,600 (HR 0000 through 9915)

AR bits

448 (AR 0000 through 2715

LR bits

1,024 (LR 0000 through 6315)

Timers/Counters

512 (TIM/CNT 000 through 511) TIMHs: 0 through 99.99 s

DM words

Read/write: 1,000 (DM 0000 through 0999) Read only: 1,000 (DM 1000 through 1999)

RUN Output

Memory Protection

Self-diagnostic Functions

Program Check

66

Special instructions: 34 to 724 ms

(10000 through 19915)

TIMs: 0 through 999.9 s CNT: 0 through 9999 counts DM area is in Memory Pack.

Contacts are closed while PC is in RUN mode and operating. Max. switching capacity: 2A 250 VAC (resistive load) 0.5 A 250 VAC (inductive load, cos of phase angle = 0.4) 2 A 24 VDC Status of HR bits, AR bits, preset value of counters (CNT), and contents of data memory (DM) are retained during power failure. Length of memory protection depends on the Memory Pack model being used (refer to Section 2-6 Memory Packs). CPU failure (watchdog timer) Battery failure Cycle time error Memory failure I/O bus failure Host Link error Remote I/O error, etc. Program check (executed on start of RUN operation): END missing Instruction errors (Program can be checked by Programming Console or GPC at three levels.)

Page 81

Appendix B

Specifications

AC Input Unit C200H-IA121 Rated Input Voltage

100 to 120 VAC 50/60 Hz

Operating Input Voltage

85 to 132 VAC 50/60 Hz

Input Impedance

9.7 kW (50 Hz), 8 kW (60 Hz)

Input Current

10 mA typical (at 100 VAC)

ON Voltage

60 VAC min.

OFF Voltage

20 VAC max.

ON Response Time

35 ms max. (at 100 VAC, 25°C)

OFF Response Time

55 ms max. (at 100 VAC, 25°C)

No. of Circuits

1 (8 points/common)

Internal Current Consumption

10 mA 5 VDC max.

Weight

250 g max.

Dimensions

A-shape

Circuit Configuration IN

100 to 120 VAC

IN

0.33 mF 470 W 330 kW 910 W

COM

Internal circuit

Input LED indicator

Terminal Connections 0 A0 1 2 100 to 120 VAC

3 4 5 6 7 COM

NC

A1 A2 A3 A4 A5 A6 A7 A8 A9

67

Page 82

Appendix B

Specifications

AC Input Unit C200H-IA122/IA122V Rated Input Voltage

100 to 120 VAC 50/60 Hz

Operating Input Voltage

85 to 132 VAC 50/60 Hz

Input Impedance

9.7 kW (50 Hz), 8 kW (60 Hz)

Input Current

10 mA typical (at 100 VAC)

ON Voltage

60 VAC min.

OFF Voltage

20 VAC max.

ON Response Time

35 ms max. (at 100 VAC, 25°C)

OFF Response Time

55 ms max. (at 100 VAC, 25°C)

No. of Circuits

1 (16 points/common)

Internal Current Consumption

10 mA 5 VDC max.

Weight

IA122: 300 g max. IA122V: 400 g max.

Dimensions

B-shape

Circuit Configuration IN

100 to 120 VAC

IN

0.33 mF 470 W 330 kW 910 W

COM

Input LED indicator

Terminal Connections

1 3 5 100 to 120 VAC

7 9 11 13 15 COM

68

B0 A0 A1 A2 A3 A4 A5 A6 A7 A8

0

B1

2

B2

4

B3

6

B4

8

B5 10 B6 12 B7 14 B8

NC

B9

NC

Internal circuit

Page 83

Appendix B

Specifications

AC Input Unit C200H-IA221 Rated Input Voltage

200 to 240 VAC 50/60 Hz

Operating Input Voltage

170 to 264 VAC 50/60 Hz

Input Impedance

21 kW (50 Hz), 18 kW (60 Hz)

Input Current

10 mA typical (at 200 VAC)

ON Voltage

120 VAC min.

OFF Voltage

40 VAC max.

ON Response Time

35 ms max. (at 200 VAC, 25°C)

OFF Response Time

55 ms max. (at 200 VAC, 25°C)

No. of Circuits

1 (8 points/common)

Internal Current Consumption

10 mA 5 VDC max.

Weight

250 g max.

Dimensions

A-shape

Circuit Configuration IN 0.15 mF

820 W (IA221)

IN 200 to 240 VAC 680 kW 910 W

COM

Internal circuit

Input LED indicator

Terminal Connections 0 A0 1 2 100 to 120 VAC

3 4 5 6 7 COM

NC

A1 A2 A3 A4 A5 A6 A7 A8 A9

69