Page 534

Appendix A

Standard Models Optical Power Tester Name

Specifications

Head Unit

Model number

S3200-CAT200 2 (provided with the Tester)

S3200-CAT2000

S3200-CAT270 2 (provided with the Tester)

S3200-CAT2700

SYSMAC BUS: C200H-RM001-PV1 C200H-RT001/RT002-P C500-RM001-(P)V1 C500-RT001/RT002-(P)V1

S3200-CAT282 2 (provided with the Tester)

S3200-CAT2820

SYSMAC NET: S3200-LSU03-01E C500-SNT31-V4

S3200-CAT320 2 (provided with the Tester)

S3200-CAT3200

Optical Power Tester (see note) SYSMAC NET: (provided with a connector CV500-SNT31 adapter, light source unit, small C200HS-SNT32 single-head plug, hard case, SYSMAC LINK: and AC adapter) CV500-SLK11 C200HW-SLK13/14 CV1000H-SLK11

Standards ---

Note: There is no difference between the light source unit and connector adapter for the Head Unit and those for the Optical Power Tester. Head Unit Name Head Units (a set consisting of light source unit and connector adapter) (see note)

Specifications

Model number

SYSMAC NET: CV500-SNT31 C200HS-SNT32

S3200-CAT2002

SYSMAC LINK: CV500-SLK11 C200HW-SLK13/14 CV1000H-SLK11

S3200-CAT2702

SYSMAC BUS: C500-RM001-(P)V1 C500-RT001/RT002-(P)V1 C200H-RM001-PV1 C200H-RT001/RT002-PV1

S3200-CAT2822

SYSMAC NET: S3200-LSU03-01E C500-SNT31-V4

S3200-CAT3202

Standards ---

Note: Use a proper Head Unit model for the optical module to be used. If two types of optical modules (unit type and board type) are used, order an Optical Power Tester plus a proper Head Unit model. Master Fiber Set Name Master Fiber Sets (1 m)

Specifications

Model number

S3200-CAT3202 (SYSMAC NET, NSB, NSU, Bridge)

S3200-CAT3201

S3200-CAT2002/CAT2702 (SYSMAC NET, SYSMAC LINK)

S3200-CAT2001H

S3200-CAT2822 (SYSMAC BUS)

S3200-CAT2821

Standards ---

Note: 1. The Master Fiber Set is used in combination with the Optical Power Tester to check the optical levels of optical fiber cables connected to optical fiber cable connectors. 2. Optical fiber cables must be prepared and connected by specialists. 3. The Optical Power Tester, Head Unit, Master Fiber set, and Optical Fiber Assembling Tool are required to connect optical fiber cables.

516

Page 535

Appendix A

Standard Models

Programming Devices Name

Specifications

Model number

Standards

Hand-Held, w/backlight

C200H-PRO27-E

U, C

2-m Connecting Cable included

CQM1-PRO01-E

U, C

Programming Console Mounting Bracket

Used to attach Hand-held Programming Console to a panel.

C200H-ATT01

---

Programming Console Connecting Cables

For Hand-held Programming Console

2m

C200H-CN222

---

4m

C200H-CN422

---

Programming Consoles

Data Setting Console

Used for data input and process value display for the C200H-CP114, and

C200H-DSC01

Data Setting Console Connecting Cables

For C200H-DSC01

2m

C200H-CN225

4m

C200H-CN425

Connecting Cable

Used to connect an IBM PC/AT or compatible to the C200HX/HG/HE.

3.3 m

CQM1-CIF02

---

Optional Products Name I/O Unit Cover

Specifications Cover for 10-pin terminal block

Model number C200H-COV11

Standards ---

Terminal Block Cov- Short protection for 10-pin terminal block (package of 10 covers ers); 8 pts

C200H-COV02

Short protection for 19-pin terminal block (package of 10 covers); 12 pts

C200H-COV03

Connector Cover

Protective cover for unused I/O Connecting Cable connectors

C500-COV02

Space Unit

Used for vacant slots

C200H-SP001

N, L

Battery Set

For C200H or C200HS RAM Memory Unit only

C200H-BAT09

---

517

Page 536

Appendix A

Standard Models Name

Specifications

Model number

Standards

Relay

24 VDC

G6B-1174P-FD-US ---

Backplane Insulation Plates

For C200HW-BC031 (3-slot CPU Backplane)

C200H-ATT31

For C200HW-BC051 (5-slot CPU Backplane)

C200H-ATT51

For C200HW-BC081 (8-slot CPU Backplane)

C200H-ATT81

For C200HW-BC101 (10-slot CPU Backplane)

C200H-ATTA1

For C200HW-BI031 (3-slot I/O Backplane)

C200HW-ATT32

For C200HW-BI051 (5-slot I/O Backplane)

C200HW-ATT52

For C200HW-BI081 (8-slot I/O Backplane)

C200HW-ATT82

For C200HW-BI101 (10-slot I/O Backplane)

C200HW-ATTA2

For 3-slot Backplane

C200H-ATT33

For 5-slot Backplane

C200H-ATT53

For 8-slot Backplane

C200H-ATT83

For 10-slot Backplane

C200H-ATTA3

---

External Connectors Solder terminal; 40p and a Connector Cover

C500-CE401

---

Solderless terminal; 40p and a Connector Cover (Crimp-type)

C500-CE402

---

Pressure welded terminal; 40p

C500-CE403

---

Solder terminal; 40p and a Connector Cover (Horizontal-type)

C500-CE404

---

Crimp-style terminal; 40p and a Connector Cover (Horizontaltype)

C500-CE405

---

I/O Brackets

---

N

Mounting Rails and Accessories Name

Specifications

Model number

DIN Track Mounting Bracket

1 set (2 included)

C200H-DIN01

DIN Tracks

Length: 50 cm; height: 7.3 cm

PFP-50N

Length: 1 m; height: 7.3 cm

PFP-100N

Length: 1 m; height: 16 mm

PFP-100N2

End Plate

---

PFP-M

Spacer

---

PFP-S

Standards ---

Note: Order DIN Tracks, End Plates, and Spacers in units of 10 each. SYSMAC Support Software (SSS) Name SYSMAC Support Software (for C20, C120, C200H, C200HS, C200HE, C200HG, C200HX, C500, C1000H, C2000H, CQM1, and CVM1)

518

Specifications 3.5”, 2HD for IBM PC/AT compatible Note: Version 1.0 doesn’t support the additional functions of the C200HX/HG/HE.

Model number C500-ZL3AT1-E

Standards ---

Page 537

Appendix A

Standard Models Protocol Support Software Name Protocol Support Software

Specifications 3.5”, 2HD for IBM PC/AT compatible

Model number C200HW-ZW3AT1-E

Standards ---

Training Materials Name

Specifications

Model number

Standards

SYSMAC Training System

Includes text book, cassette tape, and input switch board.

C200H-ETL01-E

---

Fuzzy Training System

Includes a Fuzzy Training System Manual, a Main C200H-ETL13-E Unit, a C200H-MR831 Memory Unit, a C200HPRO27-E Programming Console, a C200HCN222 Cable for the Programming Console, C500-SU981-E Fuzzy Training Software, an RS-232C Cable, and a carrying belt.

---

519

Page 538

This page is a scan with no text; see it in the PDF.

Page 539

Appendix B Programming Instructions A PC instruction is input either by pressing the corresponding Programming Console key(s) (e.g., LD, AND, OR, NOT) or by using function codes. To input an instruction with its function code, press FUN, the function code, and then WRITE. Refer to the pages listed programming and instruction details. Code

Mnemonic

Name, AND

AND, AND LD

AND LOAD, AND NOT

AND NOT, CNT

COUNTER, LD, Function

Page

Logically ANDs status of designated bit with execution condition. Logically ANDs results of preceding blocks.

149

Logically ANDs inverse of designated bit with execution condition. A decrementing counter.

149

LOAD

Used to start instruction line with the status of the designated bit or to define a logic block for use with AND LD and OR LD.

149

LD NOT

LOAD NOT

Used to start instruction line with inverse of designated bit.

149, OR

OR

149, OR LD

OR LOAD

Logically ORs status of designated bit with execution condition. Logically ORs results of preceding blocks., OR NOT

OR NOT

149, OUT

OUTPUT, OUT NOT

OUTPUT NOT

Logically ORs inverse of designated bit with execution condition. Turns ON operand bit for ON execution condition; turns OFF operand bit for OFF execution condition. Turns operand bit OFF for ON execution condition; turns operand bit ON for OFF execution condition (i.e., inverts operation)., RSET

RESET

Turns the operand bit OFF when the execution condition is ON, and does not affect the status of the operand bit when the execution condition is OFF.

153, SET

SET

Turns the operand bit ON when the execution condition is ON, and does not affect the status of the operand bit when the execution condition is OFF.

153, TIM

TIMER

ON-delay (decrementing) timer operation.

159

00

NOP

NO OPERATION

158

01

END

END

02

IL

INTERLOCK

03

ILC

INTERLOCK CLEAR

04 05 (@)06

JMP JME FAL

07

FALS

08

STEP

JUMP JUMP END FAILURE ALARM AND RESET SEVERE FAILURE ALARM STEP DEFINE

Nothing is executed and program moves to next instruction. Required at the end of the program. If interlock condition is OFF, all outputs are turned OFF and all timer PVs reset between this IL(02) and the next ILC(03). Other instructions are treated as NOP; counter PVs are maintained. If jump condition is OFF, all instructions between JMP(04) and the corresponding JME(05) are ignored.

09

SNXT

STEP START

10

SFT

11

KEEP

12

CNTR

Generates a non-fatal error and outputs the designated FAL number to the Programming Console. Generates a fatal error and outputs the designated FALS number to the Programming Console. When used with a control bit, defines the start of a new step and resets the previous step. When used without N, defines the end of step execution.

150

166

150

150 150

158 155 155 157 157 304 304 295

295

SHIFT REGISTER

Used with a control bit to indicate the end of the step, reset the step, and start the next step. Creates a bit shift register.

KEEP

Defines a bit as a latch controlled by set and reset inputs.

154

REVERSIBLE COUNTER

Increases or decreases PV by one whenever the increment input or decrement input signals, respectively, go from OFF to ON.

169

171

521

Page 540

Appendix B

Programming Instructions Code

Mnemonic

Name

13

DIFU

DIFFERENTIATE UP

14

DIFD

15

TIMH

DIFFERENTIATE DOWN HIGH-SPEED TIMER

(@)16

WSFT

WORD SHIFT

17 to 19

For expansion instructions.

20

CMP

COMPARE

(@)21

MOV

MOVE

(@)22

MVN

MOVE NOT

(@)23

BIN

BCD TO BINARY

(@)24

BCD

BINARY TO BCD

(@)25

ASL

(@)26

ASR

(@)27

ROL

ARITHMETIC SHIFT LEFT ARITHMETIC SHIFT RIGHT ROTATE LEFT

(@)28

ROR

(@)29

Function

Page

Turns ON the designated bit for one cycle on the rising edge of the input signal. Turns ON the bit for one cycle on the trailing edge.

151

A high-speed, ON-delay (decrementing) timer.

164

Shifts data between starting and ending words in word units, writing zeros into starting word.

178

Compares the contents of two words and outputs result to GR, EQ, and LE Flags. Copies source data (word or constant) to destination word.

193

Inverts source data (word or constant) and then copies it to destination word. Converts four-digit, BCD data in source word into 16-bit binary data, and outputs converted data to result word. Converts binary data in source word into BCD, and outputs converted data to result word. Shifts each bit in single word of data one bit to left, with CY.

180

Shifts each bit in single word of data one bit to right, with CY. Rotates bits in single word of data one bit to left, with CY.

175

ROTATE RIGHT

Rotates bits in single word of data one bit to right, with CY.

176

COM

COMPLEMENT

Inverts bit status of one word of data.

277

(@)30

ADD

BCD ADD

229

(@)31

SUB

BCD SUBTRACT

(@)32

MUL

BCD MULTIPLY

(@)33

DIV

BCD DIVIDE

(@)34

ANDW

LOGICAL AND

Adds two four-digit BCD values and content of CY, and outputs result to specified result word. Subtracts a four-digit BCD value and CY from another four-digit BCD value and outputs result to the result word. Multiplies two four-digit BCD values and outputs result to specified result words. Divides four-digit BCD dividend by four-digit BCD divisor and outputs result to specified result words. Logically ANDs two 16-bit input words and sets corresponding bit in result word if corresponding bits in input words are both ON.

(@)35

ORW

LOGICAL OR

Logically ORs two 16-bit input words and sets corresponding bit in result word if one or both of corresponding bits in input data are ON.

279

(@)36

XORW

EXCLUSIVE OR

Exclusively ORs two 16-bit input words and sets bit in result word when corresponding bits in input words differ in status.

280

(@)37

XNRW

EXCLUSIVE NOR

Exclusively NORs two 16-bit input words and sets bit in result word when corresponding bits in input words are same in status.

281

(@)38

INC

BCD INCREMENT

Increments four-digit BCD word by one.

228

(@)39

DEC

BCD DECREMENT

Decrements four-digit BCD word by one.

228

(@)40

STC

SET CARRY

Sets carry flag (i.e., turns CY ON).

229

(@)41

CLC

CLEAR CARRY

Clears carry flag (i.e., turns CY OFF).

229

45

TRSM

Initiates data tracing.

306

(@)46

MSG

TRACE MEMORY SAMPLE MESSAGE

Displays a 16-character message on the Programming Console display.

307

47 & 48

For expansion instructions.

(@)50

ADB

BINARY ADD

243

(@)51

SBB

BINARY SUBTRACT

Adds two four-digit hexadecimal values and content of CY, and outputs result to specified result word. Subtracts a four-digit hexadecimal value and CY from another four-digit hexadecimal value and outputs result to the result word.

522

151

180

204 205 175

176

231 235 236 278

245

Page 541

Appendix B

Programming Instructions Code

Mnemonic

Name

Function

Page

(@)52

MLB

BINARY MULTIPLY

Multiplies two four-digit hexadecimal values and outputs result to specified result words.

248

(@)53

DVB

BINARY DIVIDE

Divides four-digit hexadecimal dividend by four-digit hexa- 248 decimal divisor and outputs result to specified result words.

(@)54

ADDL

DOUBLE BCD ADD

Adds two eight-digit values (2 words each) and content of CY, and outputs result to specified result words.

230

(@)55

SUBL

DOUBLE BCD SUBTRACT

Subtracts an eight-digit BCD value and CY from another eight-digit BCD value and outputs result to the result words.

233

(@)56

MULL

DOUBLE BCD MULTIPLY

Multiplies two eight-digit BCD values and outputs result to specified result words.

236

(@)57

DIVL

DOUBLE BCD DIVIDE

Divides eight-digit BCD dividend by eight-digit BCD divisor and outputs result to specified result words.

237

(@)58

BINL

DOUBLE BCD TO DOUBLE BINARY

Converts BCD value in two consecutive source words into binary and outputs converted data to two consecutive result words.

205

(@)59

BCDL

DOUBLE BINARY TO DOUBLE BCD

Converts binary value in two consecutive source words into BCD and outputs converted data to two consecutive result words.

206

60 to 69

For expansion instructions.

(@)70

XFER

BLOCK TRANSFER

Moves content of several consecutive source words to consecutive destination words.

182

(@)71

BSET

BLOCK SET

Copies content of one word or constant to several consecutive words.

181

(@)72

ROOT

SQUARE ROOT

Computes square root of eight-digit BCD value and outputs truncated four-digit integer result to specified result word.

241

(@)73

XCHG

DATA EXCHANGE

Exchanges contents of two different words.

183

(@)74

SLD

ONE DIGIT SHIFT LEFT

Left shifts data between starting and ending words by one digit (four bits).

177

(@)75

SRD

ONE DIGIT SHIFT RIGHT

Right shifts data between starting and ending words by one digit (four bits).

177

(@)76

MLPX

4-TO-16/8-TO-256 DECODER

Converts up to four hexadecimal digits in source word into decimal values from 0 to 15 and turns ON, in result word(s), bit(s) whose position corresponds to converted value. Can also convert up to eight hexadecimal digits and turn ON corresponding bits in result words R to R+15.

209

(@)77

DMPX

16-TO-4/256-TO-8 ENCODER

Determines position of highest ON bit in source word(s) and writes the ON bit’s position (0 to F) to digit(s) in R. Can also determine the position of the highest ON bit in one or two groups of 16 words (S to S+15, S+16 to S+31) and writes the ON bit’s position (00 to FF) to byte(s) in R.

212

(@)78

SDEC

7-SEGMENT DECODER

Converts hexadecimal values from source word to data for seven-segment display.

215

(@)79

FDIV

FLOATING POINT DIVIDE

Divides one floating point value (Dd+1, Dd) by another (Dr+1, Dr) and outputs the result to R+1 and R.

238

(@)80

DIST

SINGLE WORD DISTRIBUTE

Moves one word of source data to destination word whose address is given by destination base word plus offset.

183

(@)81

COLL

DATA COLLECT

Extracts data from source word and writes it to destination word.

185

(@)82

MOVB

MOVE BIT

Transfers designated bit of source word or constant to des- 187 ignated bit of destination word.

(@)83

MOVD

MOVE DIGIT

Moves hexadecimal content of specified four-bit source digit(s) to specified destination digit(s) for up to four digits.

(@)84

SFTR

REVERSIBLE SHIFT REGISTER

Shifts data in specified word or series of words to either left 173 or right.

(@)85

TCMP

TABLE COMPARE

Compares four-digit hexadecimal value with values in table consisting of 16 words.

188

199

523

Page 542

Appendix B

Programming Instructions Code

Mnemonic

Name

(@)86

ASC

ASCII CONVERT

87 to 89

For expansion instructions.

(@)90

SEND

NETWORK SEND

(@)91

SBS

92

SBN

93

RET

SUBROUTINE ENTRY SUBROUTINE DEFINE RETURN

(@)94

WDT

(@)97

IORF

WATCHDOG TIMER REFRESH I/O REFRESH

(@)98

RECV

NETWORK RECEIVE

(@)99

MCRO

MACRO

Function

Page

Converts hexadecimal values from the source word to eight-bit ASCII code starting at leftmost or rightmost half of starting destination word.

218

Used for communications with other PCs linked through the SYSMAC NET Link System or SYSMAC LINK System. Calls and executes subroutine N.

322

Marks start of subroutine N.

286

Marks the end of a subroutine and returns control to main program. Increases the watchdog timer PV by 0 to 6300 ms.

286

Refreshes all I/O words between the start and end words.

310

Used for communications with other PCs linked through the SYSMAC NET Link System or SYSMAC LINK System. Calls and executes a subroutine replacing I/O words.

327

285

310

287

Expansion Instructions The following table shows the instructions that can be treated as expansion instructions. The default function codes are given for instructions that have codes assigned by default. Code

Mnemonic

Name

Function

17

(@)ASFT

ASYNCHRONOUS SHIFT REGISTER

Creates a shift register that exchanges the contents of adjacent words when one of the words is zero and the other is not.

178

18

(@)SCAN

CYCLE TIME

Sets the minimum cycle time (0 to 999.0 s).

305

19

(@)MCMP

MULTI-WORD COMPARE

192

47

(@)LMSG

48

(@)TERM

32-CHARACTER MESSAGE TERMINAL MODE

60

CMPL

DOUBLE COMPARE

Compares a block of 16 consecutive words to another block of 16 consecutive words. Outputs a 32-character message to the Programming Console. Switches the Programming Console to TERMINAL mode for the normal keyboard mapping operation. Compares two eight-digit hexadecimal values.

61

(@)MPRF (@)XFRB

63

(@)LINE

COLUMN TO LINE

64

(@)COLM

LINE TO COLUMN

65

(@)SEC

HOURS TO SECONDS

Refreshes I/O words allocated to Group-2 High-density I/O Units. Copies the status of up to 255 specified source bits to the specified destination bits. Copies a bit column from 16 consecutive words to the specified word. Copies the 16 bits from the specified word to a bit column of 16 consecutive words. Converts hour and minute data to second data.

311

62

GROUP-2 HIGH-DENSITY I/O REFRESH TRANSFER BITS

66

(@)HMS

SECONDS TO HOURS

Converts second data to hour and minute data.

208

67

(@)BCNT

BIT COUNTER

312

68

(@)BCMP

BLOCK COMPARE

69

(@)APR

ARITHMETIC PROCESS

Counts the total number of bits that are ON in the specified block of words. Judges whether the value of a word is within 16 ranges (defined by lower and upper limits). Performs sine, cosine, or linear approximation calculations.

87

TTIM

TOTALIZING TIMER

Creates a totalizing timer.

165

88

ZCP

AREA RANGE COMPARE

Compares a word to a range defined by lower and upper limits and outputs the result to the GR, EQ, and LE flags.

200

89

(@)INT

INTERRUPT CONTROL

Performs interrupt control, such as masking and unmasking the interrupt bits for I/O interrupts.

289

524

Page

308 309 196

189 224 225 207

197 263

Page 543

Appendix B

Programming Instructions Code

Mnemonic

Name

---

7SEG

---

(@)ADBL

7-SEGMENT DISPLAY OUTPUT DOUBLE BINARY ADD

---

AVG

AVERAGE VALUE

---

(@)BXF2

---

Function

Page

Converts 4- or 8-digit BCD data to 7-segment display format and then outputs the converted data. Adds two 8-digit binary values (normal or signed data) and outputs the result to R and R+1. Adds the specified number of hexadecimal words and computes the mean value. Rounds off to 4 digits past the decimal point.

340

EM BANK TRANSFER

Moves content of several consecutive source words to consecutive destination words. Words in the current EM bank can be specified for the source or destination.

191

CMCR

PCMCIA CARD MACRO

Performs macros to write files, read files, compare files to memory, search files, and other operations for PCMCIA Card Interface Units.

357

---

CPS CPSL

---

(@)DBS

---

(@)DBSL

---

DSW

DOUBLE SIGNED BINARY DIVIDE DIGITAL SWITCH INPUT

Compares two 16-bit (4-digit) signed binary values and outputs the result to the GR, EQ, and LE flags. Compares two 32-bit (8-digit) signed binary values and outputs the result to the GR, EQ, and LE flags. Divides one 16-bit signed binary value by another and outputs the 32-bit signed binary result to R+1 and R. Divides one 32-bit signed binary value by another and outputs the 64-bit signed binary result to R+3 to R. Inputs 4- or 8-digit BCD data from a digital switch.

202

---

SIGNED BINARY COMPARE DOUBLE SIGNED BINARY COMPARE SIGNED BINARY DIVIDE

---

(@)EMBC

SELECT EM BANK

321

---

(@)FCS

FCS CALCULATE

---

FPD

FAILURE POINT DETECT

Changes the current EM bank to the specified bank number. Checks for errors in data transmitted by a Host Link command. Finds errors within an instruction block.

---

(@)HEX

ASCII-TO-HEXADECIMAL

Converts ASCII data to hexadecimal data.

219

---

(@)IEMS

INDIRECT EM ADDRESSING

Changes the destination of indirect DM addressing to DM or the specified EM bank. This instruction can be used to change the current EM bank.

320

---

(@)IORD

SPECIAL I/O UNIT READ

354

---

(@)IOWR

SPECIAL I/O UNIT WRITE

---

(@)MAX

FIND MAXIMUM

---

(@)MBS

---

(@)MBSL

SIGNED BINARY MULTIPLY DOUBLE SIGNED BINARY MULTIPLY

Transfers data from the specified Special I/O Unit’s memory to words in the PC. Transfers data from words in the PC to the specified Special I/O Unit’s memory. Finds the maximum value in specified data area and outputs that value to another word. Multiplies the signed binary content of two words and outputs the 8-digit signed binary result to R+1 and R. Multiplies two 32-bit (8-digit) signed binary values and outputs the 16-digit signed binary result to R+3 through R.

---

(@)MIN

FIND MINIMUM

258

---

MTR

MATRIX INPUT

---

(@)NEG

2’S COMPLEMENT

Finds the minimum value in specified data area and outputs that value to another word. Inputs data from an 8 input point × 8 output point matrix and records that data in D to D+3. Converts the four-digit hexadecimal content of the source word to its 2’s complement and outputs the result to R.

---

(@)NEGL

DOUBLE 2’S COMPLEMENT

Converts the eight-digit hexadecimal content of the source words to its 2’s complement and outputs the result to R and R+1.

227

---

(@)PID

PID CONTROL

PID control is performed according to the operand and PID parameters that are preset. (The only CQM1 model that can use PID(––) is the

266

---

(@)PMCR

PROTOCOL MACRO

Calls and executes the specified communications sequence (protocol) that has been registered in the Communications Board.

339

249 259

203 255 256 343

312 314

355 257 253 254

352 226

525