Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of C200HX/C200HG/C200HE Programmable Controllers Operation Manual

Manual · Omron

C200HX/C200HG/C200HE Programmable Controllers Operation Manual

Manual586 pagesPDF 3.4 MB

Operation manual for the Omron C200HX, C200HG and C200HE programmable controllers: memory areas, programming, instructions and errors.

What this file really is

The old site listed this file as “Operators Manual” for the Omron C200H-IA122, C200H-ID212 and 13 more models. The file is named for the C200H-IA122 input unit, but it is the general operation manual for the C200HX/HG/HE programmable controllers and does not single out that unit.

Download the PDF3.4 MB

Names · 1 model

The models it names

Filed with · 14 models

Also filed with these models on the old site

Summary

What is in it

Omron's operation manual for the C200HX/HG/HE programmable controllers. It explains ladder-diagram basics and Omron terminology, the CPU Unit hardware and Memory Cassettes, how memory areas are divided and mapped to I/O, writing and entering programs with the Programming Console, the full instruction set, cycle time and I/O response timing, program monitoring, serial communications (Host Link, RS-232C, PC Links, NT Links, Protocol Macro), troubleshooting and Host Link commands.

Its parts

  1. Precautions
  2. Introduction
  3. Hardware Considerations
  4. Memory Areas
  5. Writing and Inputting the Program
  6. Instruction Set
  7. Program Execution Timing
  8. Program Monitoring and Execution
  9. Serial Communications
  10. Troubleshooting
  11. Host Link Commands

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Operation manual for the Omron C200HX, C200HG and C200HE programmable controllers, including CPU Units such as the C200HE-CPU42-E. It explains memory areas, ladder programming, the instruction set, Programming Console operation, communications, troubleshooting and host link commands, and ends with a list of standard Units. The I/O, link and other Units the site files it under appear only in that list; installation is in a separate Installation Guide.

Read for this summary: pages 11, 22, 465 to 470, 523 to 529 and 536 of 586.

Document
Operation manual for C200HX/HG/HE PLCs; installation is in a separate Installation Guide p. 11
CPU Units
C200HE-CPU11-E, -CPU32-E, -CPU42-E; C200HG-CPU33-E to -CPU63-E; C200HX-CPU34-E to -CPU64-E p. 523
Power Supply Units
C200HW-PA204 (100 to 120/200 to 240 VAC), C200HW-PA204S (adds 24-VDC output terminals), C200HW-PD024 (24 VDC) p. 524
CPU Backplanes
C200HW-BC031, BC051, BC081, BC101 (3, 5, 8, 10 slots) p. 523
Expansion Backplanes
C200HW-BI031, BI051, BI081, BI101 (3, 5, 8, 10 slots) p. 524
I/O Connecting Cables
C200H-CN311, CN711, CN221, CN521, CN131 (30 cm to 1,000 cm); 12 m total maximum p. 524
Communication Boards
C200HW-COM01 to C200HW-COM06-E: RS-232C, RS-422/485 or SYSMAC LINK/NET ports, some with protocol macro p. 523
Memory Cassettes
EEPROM C200HW-ME04K, ME08K, ME16K, ME32K (4K to 32K words); EPROM C200HS-MP16K p. 523
C200H-IA122
Listed as a 16-point AC Input Unit, 100 to 120 VAC (C200H-IA122/IA122V) p. 525
Error indicator
ALM/ERR lit: fatal error, PC stops; flashing: non-fatal error p. 466
Battery error
F7, BATT LOW: backup battery missing or low p. 469
Cycle time error
F8, CYCLE TIME OVER: watchdog timer exceeded 100 ms p. 468
Fatal error codes
F0 no END, F1 memory error, C0 to C3 I/O bus error, E0 I/O table error, E1 too many Units p. 469, 470
Programming software
SYSMAC Support Software C500-ZL3AT1-E, 3.5 in. disk for IBM PC/AT compatibles p. 536

What this manual walks you through

  • Ladder-diagram programming and the full instruction set p. 11
  • Memory areas and how I/O points map to bits p. 11
  • Using the Memory Cassette for program and I/O memory data p. 11
  • Program execution timing p. 11
  • Host link commands over the PLC ports p. 11
  • Programming alarms and messages with FAL, FALS and MSG p. 466
  • Reading and clearing error messages on the Programming Console p. 466
  • A simplified CPU Unit troubleshooting procedure and error tables p. 467, 468, 469, 470
  • Choosing Units from the standard model lists p. 22, 523

Good to know

  • For most hardware errors and some fatal software errors the PC stops the program and turns off all outputs. p. 466
  • Errors and messages can be cleared only in PROGRAM mode. p. 466
  • The C200H-OC225, C200H-OD212 and C200H-B7AO1 mount only on Backplanes whose model number ends in -V1 or -V. p. 526
  • An Interrupt Input Unit on an Expansion I/O Rack loses its interrupt function. p. 526

Questions this manual answers

What does BATT LOW (error F7) mean on a C200HE?

The backup battery is missing or its voltage has dropped. The manual says to check the battery and replace it if necessary. p. 469

Which power supply units fit the C200HX/HG/HE?

The C200HW-PA204 (100 to 120/200 to 240 VAC), the C200HW-PA204S (same, with 24-VDC output terminals) and the C200HW-PD024 (24 VDC). p. 524

How do I clear error messages with the Programming Console?

Press CLR, FUN and MONTR to read each message; in PROGRAM mode MONTR clears it, and ERR CHK OK shows when all are cleared. p. 466

What is the Omron C200H-IA122?

The standard model list gives the C200H-IA122/IA122V as a 16-point AC Input Unit for 100 to 120 VAC. p. 525

What does I/O BUS ERR mean on a C200HX/HG/HE?

Error C0 to C3 is a bus fault between the CPU Unit and I/O Units; the last digit gives the Rack number, so check the cables between Racks. p. 469

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Programmable Controllers C200HX/C200HG/C200HE1
  2. Terms and Conditions of Sale4
  3. Contact Information586

From the PDF’s own bookmarks.

The whole text · 60 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Programmable Controllers C200HX/C200HG/C200HE1-3
  2. Pages 4 to 134-13
  3. Pages 14 to 2314-23
  4. Pages 24 to 3324-33
  5. Pages 34 to 4334-43
  6. Pages 44 to 5344-53
  7. Pages 54 to 6354-63
  8. Pages 64 to 7364-73
  9. Pages 74 to 8374-83
  10. Pages 84 to 9384-93
  11. Pages 94 to 10394-103
  12. Pages 104 to 113104-113
  13. Pages 114 to 123114-123
  14. Pages 124 to 133124-133
  15. Pages 134 to 143134-143
  16. Pages 144 to 153144-153
  17. Pages 154 to 163154-163
  18. Pages 164 to 173164-173
  19. Pages 174 to 183174-183
  20. Pages 184 to 193184-193
  21. Pages 194 to 203194-203
  22. Pages 204 to 213204-213
  23. Pages 214 to 223214-223
  24. Pages 224 to 233224-233
  25. Pages 234 to 243234-243
  26. Pages 244 to 253244-253
  27. Pages 254 to 263254-263
  28. Pages 264 to 273264-273
  29. Pages 274 to 283274-283
  30. Pages 284 to 293284-293
  31. Pages 294 to 303294-303
  32. Pages 304 to 313304-313
  33. Pages 314 to 323314-323
  34. Pages 324 to 333324-333
  35. Pages 334 to 343334-343
  36. Pages 344 to 353344-353
  37. Pages 354 to 363354-363
  38. Pages 364 to 373364-373
  39. Pages 374 to 383374-383
  40. Pages 384 to 393384-393
  41. Pages 394 to 403394-403
  42. Pages 404 to 413404-413
  43. Pages 414 to 423414-423
  44. Pages 424 to 433424-433
  45. Pages 434 to 443434-443
  46. Pages 444 to 453444-453
  47. Pages 454 to 463454-463
  48. Pages 464 to 473464-473
  49. Pages 474 to 483474-483
  50. Pages 484 to 493484-493
  51. Pages 494 to 503494-503
  52. Pages 504 to 513504-513
  53. Pages 514 to 523514-523
  54. Pages 524 to 533524-533
  55. Pages 534 to 543534-543
  56. Pages 544 to 553544-553
  57. Pages 554 to 563554-563
  58. Pages 564 to 573564-573
  59. Pages 574 to 583574-583
  60. Pages 584 to 586584-586

The file

Revision and size

RevisionCat. No. W303-E1-09, Revised August 2004
PublisherOMRON
Pages586
PDF3.4 MB
TextText from the PDF itself; page 586 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 586

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 586
Page 2
Page 2of 586
Page 3
Page 3of 586