OMRON operation manual for two C200H PLC ID Sensor Units: the C200H-IDS01-V1 electromagnetic inductor unit and the IDS21 microwave unit, which read from and write to Data Carriers on moving work pieces through R/W Heads or Antennas. It covers system description, installation and connections, switch and word settings, the user program and communication commands, program examples, monitoring and timing, troubleshooting, specifications and use with CS1-series PCs.
Its parts
- Precautions
- System Description and Installation
- Operation
- Programming
- Troubleshooting
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Operation manual for two Omron SYSMAC C200H ID Sensor Units: the C200H-IDS01-V1 electromagnetic induction unit and the C200H-IDS21 microwave unit. It covers mounting on a C200H PC, switch and word settings, programming, monitoring with the Handheld Programming Console, and troubleshooting.
- Device type
- C200H-IDS01-V1: electromagnetic induction ID Sensor Unit that mounts to a C200H PC p. 17
- Read/Write Head
- C200H-IDS01-V1: one Read/Write Head per unit p. 20, 21
- EEPROM Data Carriers
- C200H-IDS01-V1 reads and writes V600-D@@P@@ EEPROM Data Carriers p. 18
- Commands
- Read, Write, Auto Read, Auto Write, Clear-all, Auto Read/Write Abort, Data Management (C200H-IDS01-V1 only) p. 93
- Data per instruction
- Up to 512 words (1024 bytes), at 20 words/scan p. 93
- Current consumption
- 250 mA max. at 5 VDC; 120 mA max. at 26 VDC to drive the head p. 93
- Dimensions and weight
- 35 x 130 x 100.5 mm (W x H x D); 400 grams max. p. 93
- Head cable length
- 30.5 m max. with V600-H07; 50.5 m max. with V600-H11/H51/H52 p. 17
- PC words used
- 5 words in IR words 100 through 199 (n = 100 + 10 x unit number) p. 28, 93
- Unit number
- 0 through 9, set on the front panel switch p. 27
- Error log backup
- Capacitor keeps error data 15 days at 25°C, less as temperature rises p. 93, 94
- Ambient conditions
- 0° to 55°C; 35 to 85% humidity, without condensation p. 89
- Programming Console
- C200H-PRO27-E Hand-held Programming Console, cable 4 m max. p. 17, 93
What this manual walks you through
- Mounting the unit on a C200H Backplane or Remote I/O Slave Rack p. 22, 23
- Connecting the Read/Write Head p. 23
- Setting the unit number and back panel DIP switch p. 27
- IR word allocation and status flags p. 28, 29, 30
- Choosing read data areas and avoiding Read Format errors p. 31
- Checking data and EEPROM life with the data management commands p. 19
- What the V1 adds over the C200H-IDS01 p. 18
- Monthly maintenance checklist p. 89
- Fixing malfunctions with the diagnostic flowcharts p. 89, 90, 91
Good to know
- The error storage area is undefined when shipped; clear it before first use. p. 31
- Two units with the same unit number cause an I/O Unit Over error. p. 27
- The MD-L/MD-S overwrite count commands need units of lot @@55 (May 1995) or later. p. 19
- An EEPROM Data Carrier allows a total of 100,000 overwrites. p. 19
- Turn off the PC power before removing or replacing the unit. p. 89
Questions this manual answers
Is the C200H-IDS01-V1 compatible with the C200H-IDS01?
Yes. The manual states the C200H-IDS01 is compatible with the V1, which adds EEPROM Data Carrier support, data management commands and hexadecimal page display. p. 18, 19
How many ID Sensor Units can go on one C200H PC?
Up to ten Special I/O Units per PC system; Backplane size, Power Supply and current draw may limit the number further. p. 22
What does it mean when the RUN light on the C200H-IDS01-V1 is off?
RUN is lit green while the unit operates and goes out when an error occurs in the ID Sensor Unit. p. 20
What causes a No Data Carrier error?
The unit did not detect a Data Carrier after receiving Read, Write or Clear-all from the CPU. p. 30
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 15 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 51-5
- Pages 6 to 96-9
- PRECAUTIONS10-15
- SECTION 1 System Description and Installation16-25
- SECTION 2 Operation, pages 26 to 3526-35
- SECTION 2 Operation, pages 36 to 4536-45
- SECTION 2 Operation, pages 46 to 5346-53
- SECTION 3 Programming, pages 54 to 6254-62
- SECTION 3 Programming, pages 63 to 7163-71
- SECTION 3 Programming, pages 72 to 8072-80
- SECTION 3 Programming, pages 81 to 8781-87
- SECTION 4 Troubleshooting88-91
- Appendices92-103
- Pages 104 to 109104-109
- Revision History110-114
The file