The text of a manual · part 8 of 15
SYSMAC C200H-IDS01-V1/IDS21 ID Sensor Operation Manual: SECTION 3 Programming, pages 54 to 62
Pages 54 to 62 of 114, from SYSMAC C200H-IDS01-V1/IDS21 ID Sensor Operation Manual
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron C200H-IDS01-V1
Page 54
SECTION 3 Programming This section describes programming and includes example programs that illustrate data transfer between the Unit and the CPU. Monitoring functions and timing considerations are also covered in this section. 3-1
3-2
3-3
Program Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
3-1-1
Writing to the Data Carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
3-1-2
Reading from the Data Carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
43
Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51
3-2-1
Connecting the Handheld Programming Console . . . . . . . . . . . . . .
51
3-2-2
Mode Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
52
3-2-3
The JOB Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
56
3-2-4
Address/Data Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
59
3-2-5
Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
62
3-2-6
Step Write (WRITE 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
63
3-2-7
Continuous Write (WRITE 2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64
3-2-8
Monitor Test (TEST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65
3-2-9
Error Log Display (ERR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
66
3-2-10 Error Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
70
Timing Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
70
3-3-1
Command Processing Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
70
3-3-2
Turnaround Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72
39
Page 55
Program Examples
Section 3-1
Section Overview
This section contains example programs that illustrate data transfer between the ID Sensor Unit and the CPU of the PC. Six communication commands (Write, Auto Write, Read, Auto Read, Clear-all, and Auto Read/Write Abort) can be used. Also included in this section are a description of Monitoring functions and an explanation of Command Processing Time and Turnaround Time.
3-1
Program Examples The following conditions apply to the example programs in this section: 1,2,3...
1. The ID Sensor Unit unit number switch is set to 0. 2. The command data is stored in the DM area of the CPU. Refer to 2-3 The User Program for an overview of program operation.
3-1-1
Writing to the Data Carrier This section illustrates program examples of the Write, Auto Write, and Clearall commands.
Program Example 1: The Write Command Command execution input
10400 ID busy
10900
MOV (21) #0007 101
MOV (21) #0000 102
Sets the number of words in the command data (7 in this example) Word n+1 Sets the beginning word where the command data is stored (DM 0000 in this example). Word n+2
10900
(Bit in IR area) Holds the status until the ID Sensor Unit begins executing the command.
10000
Command execution flag
10900
Command data in CPU 15
40
Data to be written to Data Carrier 0 Address 7
00
DM 0000
57
54
WT (Write)
DM 0001
48
31
H1 (Hexadecimal, Head 1)
DM 0002
00
06
DM 0003
10
11
Beginning address in which data is to be written in Data Carrier
DM 0004
12
13
Data to be written to Data Carrier, numbers 10 through 14 (5 bytes)
DM 0005
14
2A
DM 0006
0D
00
0006
10
0007
11
Write is executed. 0008
12
0009
13
000A
14
If the number of bytes to be written to the Data Carrier is odd, shift codes 2A and 0D forward one byte and write 00 into the last 8 bits.
Data cannot be written to write-protected areas.
Page 56
Program Examples
Section 3-1
Operation
When the command execution input is ON, the number of words in the command (7) and the beginning word where the command is stored (DM 0000) are set using MOV, and the command execution flag (10000) is turned ON. IR 10900 holds this status until the ID Sensor Unit begins executing the command. While the ID Sensor Unit is executing the command, the ID Busy flag (word n+4 bit 00) is set to ON. When the write operation is complete, the ID Busy flag turns OFF. Although the ID Busy flag normally turns OFF upon completion of the command, if the command execution flag is ON at this time, the ID Busy flag will stay ON. Therefore, design the program so that the command execution flag will be turned OFF when the ID Busy flag turns ON, as in the example.
Program Example 2: The Auto Write Command Command execution input
10400 ID busy
10901
MOV (21) #0008 101
MOV (21) #0100 102
Sets the number of words in the command data (8 in this example) Word n+1 Sets the beginning word where the command data is stored (example shows DM 0100). Word n+2
10901
(Bit in IR area) Holds the status until the ID Sensor Unit begins executing the command.
10000
Command execution flag
10901
Command data in the CPU 15
Data to be written to Data Carrier 0 Address 7
00
DM 0100
41
57
AW (auto write)
DM 0101
48
31
H1 (Hexadecimal, Head 1)
DM 0102
00
0B
Beginning address in which the data is to be written in the Data Carrier
DM 0103
15
16
DM 0104
17
18
DM 0105
19
1A
DM 0106
1B
2A
DM 0106
0D
00
Operation
Auto write is executed.
Data to be written to the Data Carrier, 15 through 1B (7 bytes)
If the number of bytes to be written to the Data Carrier is odd, shift codes 2A and 0D forward one byte and write 00 into the last 8 bits.
000B
15
000C
16
000D
17
000E
18
000F
19
0010
1A
0011
1B
Data cannot be written to write-protected areas.
When the command execution input is ON, the number of words in the command (8) and the beginning word where the command data is stored (DM 0100) are set using MOV, and the command execution flag (10000) is turned ON. IR 10901 holds this status until the ID Sensor Unit starts executing the command.
41
Page 57
Program Examples
Section 3-1 While the ID Sensor Unit is executing the command, the ID Busy flag (word n+4 bit 00) is turned ON. When the Auto Write operation is complete, the ID Busy flag turns OFF. While the ID Sensor Unit is waiting for the Data Carrier to approach the antenna, the Data Carrier waiting flag (word n+4 bit 01) is ON. Although the ID Busy flag normally turns OFF upon completion of the command, if the command execution flag is ON at this time, the ID Busy flag will stay ON. Therefore, design the program so that the command execution flag will be turned OFF when the ID Busy flag turns ON, as in the example.
Program Example 3: The Clear-all Command Command execution input 10400 MOV (21) #0003 101
ID busy 10904
MOV (21) #0600 102
Sets the number of words in the command data (fixed to 3 words). Word n+1 Sets the beginning word where the command data is stored (example shows DM 0600). Word n+2
10904
(Bit in IR area) Holds the status until the ID Sensor Unit begins executing the command.
10000
Command execution flag
10904
Command data in the CPU 15 00
Operation
Contents of Data Carrier's memory after Clear-all execution
DM 0600
43
41
CA (Clear-all)
DM 0601
00
31
Head 1
DM 0602
2A
0D
* Clear-all is executed.
0002 0003
0 Addresses 0000 to 0001 in the Data CarXX rier's memory are reserved for registerXX ing the Data Carrier's production date and 00 cannot be cleared. 00
* If the number of bytes to be cleared is odd, shift codes 2A and OD forward one byte and write 00 into the last 8 bits.
07FE
00
07FF
00 address 7 0000 0001
When the command execution input is ON, the number of words in the command (fixed to 3 words) and the beginning word where the command is stored (DM 0600) are set using MOV, and the command execution flag (10000) is set turned ON. IR (10904) keeps the status until the ID Sensor Unit begins executing the command. While the ID Sensor Unit is executing the command, the ID Busy flag (word n+4 bit 00) is turned ON. When the Clear-all operation is complete, the ID Busy flag turns OFF. Although the ID Busy flag normally turns OFF upon completion of the command, if the command execution flag is ON at this time, the ID Busy flag will
42
Page 58
Program Examples
Section 3-1 stay ON. Therefore, design the program so that the command execution flag will be turned OFF when the ID Busy flag turns ON, as in the example. Note Clearall clears all memory areas, including those that are write-protected.
3-1-2
Reading from the Data Carrier This section shows program examples for the Read and Auto Read commands.
Program Example 4: The Read Command Command execution input 10400 MOV (21) #0005 101
ID busy 10902
MOV (21) #0200 102
MOV (21) #0300 103
Sets the beginning word where the command data is stored (example shows DM 0200). Word n+2 Sets the receiving area (in the CPU) where the data to be read will be transferred. (DM 0300 in this example.) Word n+3 (Bit in IR area) Holds the status until the ID Sensor Unit begins executing the command.
10000
Command execution flag
Area in the CPU to which the data is read
Data in the Data Carrier 0
000A
14
000B
15
000C
16
000D
17
000E
18
000F
19
Operation
Word n+1
10902 10902
Address 7
Sets the number of words in the command data (fixed to 5 words).
15 Read is executed.
Command data in the CPU 15 00 DM 0200
52
44
RD (Read)
DM 0201
48
31
DM 0202
00
0A
DM 0203
00
06
H1 (Hexadecimal, Head 1) Beginning address of the data to be read from the Data Carrier Number of bytes to be read
DM 0204
2A
0D
00
DM 0300
14
15
DM 0301
16
17
DM 0302
18
19
If the number of bytes to be read is odd, the last 8 bits of data are undefined.
If the number of bytes to be read is odd, shift codes 2A and OD forward one byte and write 00 into the last 8 bits.
When the execution command input is ON, the number of words in the command (fixed to 5 words), the beginning word where the command is stored (DM 0200), and the beginning word number of the receiving area in the CPU are set using MOV, and the command execution flag (10000) is turned ON. IR
43
Page 59
Program Examples
Section 3-1 10902 holds this status until the ID Sensor Unit begins executing the command. While the ID Sensor Unit is executing the command, the ID Busy flag (word n+4 bit 00) is turned ON. When the Read operation is complete, the ID Busy flag turns OFF. Although the ID Busy flag normally turns OFF upon completion of the command, if the command execution flag is ON at this time, the ID Busy flag will stay ON. Therefore, design the program so that the command execution flag will be turned OFF when the ID Busy flag turns ON, as in the example.
Program Example 5: The Auto Read Command Command execution input
10400 MOV (21) #0005 101
ID busy 10903
MOV (21) #0400 102
MOV (21) #0500 103
Sets the number of words in the command data (fixed to 5 words). Word n+1 Sets the beginning word where the command data is stored (example shows DM 0400). Word n+2 Sets the receiving area (in the CPU) where the data to be read will be transferred. (DM 0500 in this example.) Word n+3
10903
(Bit in IR area) Holds the status until the ID Sensor Unit begins executing the command.
10000
Command execution flag
10903
Data in the Data Carrier Address 7 001A
001C
3A
Operation
44
38 39
001E
15
0
001B
001D
Receiving area in the CPU
3B 3C
Command data in the CPU 00 15
Auto Read is executed.
DM 0400
41
52
AR (Auto read command)
DM 0401
48
31
DM 0402
00
1A
DM 0403
00
05
H1 (Hexadecimal, Head 1) Beginning address of the data in the Data Carrier Number of bytes to be read
DM 0404
2A
0D
00
DM 0500
38
39
DM 0501
3A
3B
DM 0502
3C
XX
If the number of by tes to be read is odd, the last 8 bits of data are undefined.
If the number of bytes to be read is odd, shift codes 2A and OD forward one byte and write 00 into the last 8 bits.
When the command execution is ON, the number of words in the command (fixed to 5), the beginning word where the command is stored (DM 0400), and the beginning word of the receiving area in the CPU (DM 0500) are set using MOV, and the command execution flag (10000) is turned ON. IR 10900 holds this status until the ID Sensor Unit begins executing the command.
Page 60
Program Examples
Section 3-1 While the ID Sensor Unit is executing the command, the ID Busy flag (word n+4 bit 00) is turned ON. When Auto Write is complete, the ID Busy flag turns OFF. While the ID Sensor Unit is waiting for the Data Carrier to approach, the data Carrier waiting flag (word n+4 bit 01) is ON. Although the ID Busy flag normally turns OFF upon completion of the command, if the command execution flag is ON at this time, the ID Busy flag will stay ON. Therefore, design the program so that the command execution flag will be turned OFF when the ID Busy flag turns ON, as in the example.
Program Example 6: The Auto Read/Write Abort Command Command execution input
10401 MOV (21) #0002 101
ID busy 10905
MOV (21) #0700 102
Sets the number of words in the command data (fixed to 2 words) Word n+1 Sets the beginning word where the command data is stored (DM 0700 in this example). Word n+2
10905
(Bit in IR area) Holds the status until the ID Sensor Unit begins executing the command.
10000
Command execution flag
10905
Command data in the CPU 15 00
Operation
DM 0700
41
41
AA (Auto Read/Write Abort)
DM 0701
00
31
If the number of bytes to be read is odd, shift codes 00 and 31 forward one byte and write 00 into the last 8 bits.
When the execution command input is ON, the number of words in the command (fixed to 2 words) and the beginning word where the command is stored (DM 0700) are set using MOV, and the command execution flag (10000) is turned ON. IR (10905) holds the status until the ID Sensor Unit aborts the auto command (i.e. the Data Carrier waiting flag is OFF). While the ID Sensor Unit is executing the command, the Data Carrier waiting flag (word n+4 bit 01) and the ID Busy flag (word n+4 bit 00) are turned OFF. The Auto Read/Write Abort end flag (word n+4 bit 02) is turned ON, signifying completion of the operation. Although the ID Busy flag normally turns OFF upon completion of the command, if the command execution flag is ON at this time, the ID Busy flag will stay ON. Therefore, design the program so that the command execution flag will be turned OFF when the DC waiting flag turns OFF, as in the example.
45
Page 61
Program Examples
Section 3-1
Program Example 7: Calculation and Writing of Data Carrier’s Data Check Code Command execution input
10400 MOV(21) ID busy
#0005 101
10906
Sets the number of words in the command data to 5 words.
MOV(21) #0800 102
Sets the beginning word where the command data is stored to DM 0800.
10906
Holds the status until the ID Sensor Unit begins executing the command.
10000
Command execution flag
10906
10400 DIFD(14) 10908
Processing end
10908 ANDW(34) 104 #FF00 DM0810 CMP(20)
Judges the result of processing
DM0810 #0000 25506 10907
Command error output
Equal flag
Data in the Data Carrier Command Data in the CPU
00
15
Address
DM 0800
4D
44
0010
DM 0801
4B
31
0011
DM 0802
00
10
0012
DM 0803
00
20
0
DM 0804
2A
0D
Calculation object Check area
002D 002E 002F 0030
46
7
000F
Check code
Page 62
Program Examples Operation
Section 3-1 When the command execution input is ON, the number of words in the command (5) and the beginning word where the command is stored (DM 0800) are set using MOV, and the command execution flag (10000) is turned ON. IR 10906 holds this status until the ID Sensor Unit begins executing the command. While the ID Sensor Unit is executing the command, the ID Busy flag (word n+4 bit 00) is set to ON. When the write operation is completed, the ID Busy flag turns OFF. When the write operation has been completed, the result can be checked with an error flag. If there has been an error, the Command Error Output (10907) turns ON. Note Although the ID Busy flag normally turns OFF upon completion of the command, if the command execution flag is ON at this time, the ID Busy flag will stay ON. Therefore, design the program so that the command execution flag will be turned OFF when the ID Busy flag turns ON, as in the example.
47