Page 104
Glossary ASCII code
[A(merican) S(tandard) C(ode for) I(nformation) I(nterchange)] A standard computer code used to facilitate the interchange of information among various types of data-processing equipment.
Backplane
A base to which Units are mounted to form a Rack. Backplanes provide a series of connectors for these Units along with wiring to connect them to the CPU and Power Supply. Backplanes also provide connectors used for connection to other Backplanes. In some Systems, different Backplanes are used for different Racks; in other Systems, Racks differ only by the Units mounted to them.
backup
A copy of existing data which is valuable if the original data is accidentally erased.
bit
The smallest piece of information that can be represented on a computer. A bit has the value of either zero or one, corresponding to the electrical signals ON and OFF. A bit is one binary digit.
central processing unit
A device that is capable of storing a program and data, and executing the set of instructions contained in the program. In a PC System, the central processing unit executes the program, processes I/O signals, communicates with external devices, etc.
center displacement
In this manual, center displacement refers to the degree of misalignment of the center points of the Data Carrier and the Read/Write Head (or Antenna) at which data communication is still possible.
CPU
An acronym for central processing unit.
CPU Backplane
A Backplane used to create a CPU Rack.
CPU Rack
Part of a Rack PC, the CPU Rack contains the CPU, a Power Supply, and other Units.
Expansion I/O Unit
An I/O Unit for a Package-type PC that provides more I/O points to the PC.
flag
A bit that is turned ON and OFF automatically by the system in order to provide status information.
hexadecimal
A number system used to represent numbers in base 16 with digits 0,1,2...9,A,B...F.
Intelligent I/O Unit
A Unit, such as an ASCII Unit or Ladder Program I/O Unit, that is equipped with its own CPU and can be programmed.
I/O devices
The devices which are connected to the terminals on I/O Units, Special I/O Units, or Intelligent I/O Units. I/O devices may be part of the Control System if they function to help control other devices, or they may be part of the controlled system if they interact directly with it.
I/O Unit
The most basic type of Unit mounted to a Backplane. I/O Units include Input Units and Output Units, each of which is available in a range of specifications. I/O Units do not include Special I/O Units, Link Units, etc.
PC
An acronym for Programmable Controller.
89
Page 105
Glossary Power Supply
A Unit that mounts to a Backplane in a Rack PC. It provides power at the voltage required by the other Units on the Rack.
Programmable Controller
A small, computerlike device that can control peripheral equipment, such as an electric door or quality control devices, based on programming and peripheral input devices. Any process that can be controlled using electrical signals can be controlled by a PC. PCs can be used independently or networked together into a system to control more complex operations.
register/registered
Storing text and graphics in the RAM/ROM card from a personal computer or the ASCII Unit. Graphics that have been written to the RAM/ROM card are referred to as registered messages.
Remote I/O Slave Rack
A Backplane to which is mounted a Remote I/O Slave Unit. This Rack can be located a considerable distance from the CPU Rack, with the only connection being a cable connecting the Slave to a Remote I/O Master Unit mounted on the CPU Rack or on an Expansion I/O Rack.
Remote I/O Slave Unit
A Remote I/O Unit that is accessed through a Remote I/O Master Unit.
Remote I/O Unit
A Unit that extends the distance an Expansion I/O Rack can be from the CPU.
RS-485 interface
An industry standard connector for serial communications.
scan time
The time the PC requires to perform internal operations such as resetting the watchdog timer, reading the program, receiving input data, sending output data, and executing instructions. Scan time is monitored by the watchdog timer within the PC. If scan time takes longer than specified, an error message may be generated, or the CPU may stop. Scan times differ according to the configuration of the system.
Special I/O Unit
A dedicated Unit that is designed for a specific purpose. Special I/O Units include Position Control Units, High-speed Counters, Analog I/O Units, etc.
system configuration
The arrangement in which Units in a System are connected. This term refers to the arrangement and wiring of all the devices needed to compose the System. In OMRON terminology, “system configuration” describes the arrangement and connection of the Units comprising a Control System that includes one or more PCs.
Unit
In OMRON PC terminology, the word Unit is capitalized to indicate any product sold for a PC System. Though most of the names of these products include the word Unit, this is not always so; for example, a Remote Terminal is referred to as a Unit. Context generally makes the meaning of this word clear.
word
In digital circuits, a group of bits. Usually a word consists of four, eight, or sixteen bits. In C-series PCs, a word consists of sixteen bits. Words can be used to store data, or they can be used for I/O.
work bits
Bits in the IR area that are not being used for input or output. These bits can be used in the program in any way desired.
write protection
Write protection is a means of ensuring that specified information written to the Data Carrier cannot be altered or erased.
90
Page 106
Index A address page number, 56 changing, 56 setting, 57 address/data settings, 59 addresses setting, 60
CPU, 2, 6, 14, 24, 40–41, 52, 87 communication with, 17 reading data, 18 writing to the Data Carrier, 18
D
ASCII code, 19–24
Data Carrier address page number, 56 registration of date of production, 36 service life, 36
ASCII Code list, 83
Data Carrier memory, 29
Auto Read, 23, 44 data setting, 61
Auto Read/Write Abort, 24, 45 date of production of Data Carrier, 36 Clear-all command, 19 applications precautions, xiii
Auto Write, 22
B Backplane, 7 C200H-IDS01-V1/IDS21, 6 Basic Assurance Test (BAT), 75 Binary Coded Decimal (BCD), 14 bit number, 14, 24 Read/Write areas, 16 bit allocation, 14 diagnostic flow charts, 75 Dimensions ID Sensor Unit C200H-IDS01-V1/IDS21, 77
E error messages and reset flags, 16 newest error information, 68 error information storage, 66 error log display, 66 buzzer, 55 error storage area, 16
C
Expansion I/O Rack, 8 errors, 12, 74 error codes, 70
Clear-all, 23 coefficient, 72 coefficient values, 72 command processing time, 70, 72 commands, 3 communication Auto Read, 23 Auto Read/Write Abort, 24 Auto Write, 22 Clear-all, 23 Read, 21 Write, 20 write protection examples, 32
F flag 00 - 15, 15 Command Error, 18–19 Command Execution, 41, 43 Data Carrier Waiting, 42 error message, 16 error reset, 14 ID Busy, 18 Read Format, 19 communication commands, 19 writing to the Data Carrier, 18 compatibility, 3 Continuous Write, 64
91
Page 107
Index
G–H Glossary, 89 Handheld Programming Console, 3 Hardware C200H-IDS01-V1 front panel, 5 C200H-IDS01-V1/S21 back panel, 6 C200H-IDS21 front panel, 5 indicators, 5 hexadecimal, 20–21, 23, 60
I I/O refresh, 13 I/O Unit, Special, 8, 12–13, 16 newest error information, 66, 68 clearing, 66 key, 68 operating environment precautions, xiii
P PC Link Unit, 7–8 periodic maintenance, 74 Position Control Unit, 8 precautions applications, xiii general, xii operating environment, xiii safety, xii
ID Controller V600/V620 compatibility, 3 production date See also date of production
ID Sensor Unit modes, 52 replacement, 74
Programmable Controller, 2, 13 user program, 17 indicators and components, 5 installation precautions, xiii IR Bit allocation, 14
J–M JOB function, 56 maintenance, 74 Mean Cycle Between Failures, 66, 69 monitor modes MONITOR functions and operation, 53 monitor test, 65 monitoring, 3, 51 address/data setting, 59 addresses setting, 60 data setting, 61 READ, 59, 62 start and end addresses selecting, 59 TEST, 59 WRITE 1, 59 WRITE 2, 59
92
N–O
PROGRAM mode, 17
Programming operation, 41 Programming Console connecting, 51 keyboard sheet, 51 mode selector switch, 52 mode setting, 52 modes MONITOR, 53 PROGRAM, 53 RUN, 53 MONITOR initial display, 55 RESET display, 55
R Read, 21 Read format error, 16 Read/Write bit areas, 16 registration of Data Carrier’s date of production, 36 Remote I/O Communication Time, 72 Remote I/O Slave Rack, 8 communication time, 72 replacing the Unit, 74 returning an ID Sensor Unit, 74
Page 108
Index
S
T–W safety precautions See also precautions time turnaround, 72 scan time, 19, 72 turnaround time, 72 spare parts, 74 unit number switch, 12
Special I/O Unit, 7 user program, 17
Specifications characteristics, 78
WDT See also watchdog timer
Standard Models, 81 wiring, 8 start and end addresses selecting, 59
Word settings, 13 statistical error, 66 word number, 14–15, 56, 69 statistical error information, 69 clearing, 67 word settings, 13
Step Write, 63 work bits, 13–14 storing error information, 3
Write, 20
Switch dip, 6 Unit number, 5 write protection, 30, 32 switch DIP, 12 unit number, 12 switch settings, 12 system description, 2 System Configuration C200H-IDS01-V1 Electromagnetic Induction ID Sensor, 7 C200H-IDS21 Microwave ID Sensor Unit, 7 system configuration, 6 System Connections, 7 system connections diagram, 2 mounting the ID Sensor Unit, 7 Units on a Remote I/O Slave Rack, 7