For the Omron C200H-IDS01-V1
Page 16
SECTION 1 System Description and Installation This section describes the features, components, configuration, and installation of the ID Sensor systems. 1-1
System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
1-2
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
1-3
Components and Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
1-4
System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
1-5
System Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
1-6
Maximum Distance Between ID Sensor Unit and R/W Head . . . . . . . . . . . .
9
1-7
Maximum Distance Between ID Sensor Unit and R/W Antenna . . . . . . . . . .
9
1
Page 17
System Description
Section 1-1
Section Overview
This manual covers the operation of two ID Sensor models, the C200HIDS01-V1 Electromagnetic Induction ID Sensor Unit and the C200H-IDS21 Microwave ID Sensor Unit. The main difference between the Units is the distance at which the ID Sensor can read data from or write data to the Data Carrier. The Microwave ID Sensor Unit allows the Data Carrier to be placed farther from the Unit. This section describes the components, installation, and configuration of both models.
1-1
System Description The ID Sensor system is a versatile noncontact identification system comprising an ID Sensor Unit, a single Read/Write (R/W) Head or Antenna, and a Data Carrier. The ID Sensor mounts to a C200H Programmable Controller (PC); the Data Carrier mounts to a moving workpiece or workpiece carrier. The R/W Head or Antenna, connected to the ID Sensor Unit by a cable, must be positioned within communication range of the travel path of the Data Carrier. Responding to commands from the user program in the CPU of the PC, the ID Sensor reads data from or writes data to the Data Carrier through the R/W Head or Antenna. The operation of the ID Sensor can be monitored and tested with the Handheld Programming Console; messages appear on the display of the Console. The following diagram illustrates two ID Sensor systems, one using a C200HIDS01-V1 ID Sensor and one using a C200H-IDS21 ID Sensor.
C200H ID Sensor Systems Electromagnetic Induction ID Sensor Unit (C200H-IDS01-V1)
Connecting ConnectingCable Cable
Microwave ID Sensor Unit (C200H-IDS21)
Connecting Cable
Hand-held Programming Console* C200H-PRO27-E
Hand-held Programming Console* C200H-PRO27-E
30.5 m max. when using the V600-H07 50.5 m max. when using the V600-H11/H51/H52
Read/Write Head V600 series
R/W Antenna V620 series
Data Carrier V600 series Data Carrier V620 series
2
10 m max.
Page 18
Features
1-2
Section 1-2
Features The ID Sensor systems have the following features:
Seven Dedicated Commands
Data is transferred between the ID Sensor Unit and the Data Carrier with the following six dedicated commands: Read Write Auto Read Auto Write Clear-all Auto Read/Write Abort Data management (C200H-IDS01-V1 only) Up to 1024 bytes of data can be read from or written to the Data Carrier at one time. Clear-all clears all data in the Data Carrier’s memory (2K bytes). These commands are compatible with the V600 and V620 ID Controllers.
Monitoring with the Handheld Programming Console
The Handheld Programming Console can be used for monitoring data transfer as well as errors that have occurred during operation. A keyboard sheet for the Handheld Programming Console is included with the ID Sensor Unit.
Storage of Error Information
Error information is stored in the internal memory of the ID Sensor Unit. A built-in capacitor stores the information for 15 days (at 25°C).
Compatibility
The following table lists the compatibility between the I/D Sensor Unit and the R/W Head, R/W Antenna, or Data Carrier.
ID Sensor
Electromagnetic induction V600-H@@ R/W Head
Microwave
C200H-IDS01-V1
Yes
V600-D@@R@@ V600-D@@P@@ V620-H@@ R/W Data Carrier (with Data Carrier (with Antenna built-in battery) no built-in battery) Yes Yes No
C200H-IDS01 C200H-IDS21
Yes No
Yes No
No No
No V620-H01/-H02
V620-D@@R@@ Data Carrier (with built-in battery) No No V620-D8KR01
Note Refer to the list of applicable manuals in the About this Manual section. Differences between C200H-IDS01 and C200H-IDS01-V1
1,2,3...
The C200H-IDS01-V1, which is an updated version of the C200H-IDS01, has the following three new features in addition to all the capabilities that the C200H-IDS01 possesses. The C200H-IDS01 is compatible with the C200HIDS01-V1. 1. Connecting to Data Carrier Incorporating EEPROM The C200H-IDS01-V1 reads data from and writes data to the V600-D@@P@@ containing an EEPROM. To read data, the user can select the communications distance priority mode or communications speed priority mode with the local communications mode pin (pin 3 of the DIP switch). Neither of these modes are, however, available when the ID Sensor Unit is connected to the SRAM Data Carrier.
1 2 3
Local communications mode pin
4
3
Page 19
Features
Section 1-2 2. New Commands The C200H-IDS01-V1 incorporates data management commands, with which it is possible to check the reliability of the Data Carrier’s data. The details of the commands are as follows:
Function Checking of data
Command MD-K
MD-C
Checking of the number of overwriting operations
MD-L
MD-S
Meaning By adding a check code to the Data Carrier’s data, it is possible to detect a data error due to the battery of the Data Carrier that incorporates SRAM, or excessive overwriting operations of the Data Carrier that incorporates EEPROM. Use the MD-K command to calculate and write the check code to the Data Carrier. Use the MD-C command to collate the check code. The MD-K command and MD-C command must be always used together. Check the life of the Data Carrier’s EEPROM by counting the number of overwriting operations. The Data Carrier’s EEPROM allows a total of 100,000 overwriting operations. Use this command to specify the number of overwriting operations in the life of the EEPROM in advance. Every time a write operation is performed, 1 is subtracted and the Data Carrier will detect when the life has expired. This command is only available with models of lot number @@55 (May 1995) or later.
3. Hexadecimal Page Number Display The page number is displayed in hexadecimal, in which case the rightmost two digits of the address are displayed as the page number. In the following example, the user has access to address 0A00 or 1000.
C200H-IDS01-V1
4
C200H-IDS01 C200H-IDS21
HEAD 1 PAGE 0A
ANT. PAGE 10
STadrs00 data 00
STadrs00 data 00
Page 20
Components and Indicators
1-3
Section 1-3
Components and Indicators Although similar in appearance, note that the C200H-IDS01-V1 ID Sensor reads or writes data through a Read/Write Head and the C200H-IDS21 reads or writes data through a Read/Write Antenna.
C200H-IDS01-V1 Front Panel IDS01-V1
Indicators Unit number switch ( "Machine No.")
MACHINE No
Handheld Programming Console connector MONITOR
HEAD
Read/Write Head connector
C200H-IDS21 Front Panel IDS21
Indicators Unit number switch ( "Machine No.")
MACHINE No
Handheld Programming Console connector MONITOR
ANTENNA
Read/Write Antenna connector
Indicators
The table below explains the status of the indicators on both models. Indicator
Function
RUN
Lit (green) while the ID Sensor is operating. Unlit if an error occurs in the ID Sensor Unit.
T/R
Lit (green) during data communication. Unlit when data is not transmitted.
5
Page 21
System Configuration
Section 1-4
Back Panel C200H-IDS01-V1/IDS21
DIP switch
Backplane connector
Pin No.
Function
1
Screen messages
OFF ON
Japanese English
2
Local communications mode (see note)
OFF
Communications distance priority mode Communications speed priority mode
3, 4
Always OFF
ON
Note The user can select the communications distance priority mode or communications speed priority mode with pin 2 of the DIP switch when the C200H-IDS01-V1 accesses the EEPROM Data Carrier. Neither of these modes are, however, available when the ID Sensor Unit accesses the SRAM Data Carrier or when the C200H-IDS21 accesses any Data Carrier, in which case turn pin 2 OFF. Refer to the V600 FA ID System R/W Heads and EEPROM Data Carriers Operation Manual for the communications distance and speed of the EEPROM Data Carrier.
1-4
System Configuration The diagrams below illustrate the system configurations of the C200H-IDS01V1 Electromagnetic Induction ID Sensor Unit and the C200H-IDS21 Microwave ID Sensor Unit. The ID Sensor Unit transfers data through the Read/Write Head (or Antenna) to a Data Carrier, which is mounted on a moving workpiece. The ID Sensor Unit transfers the desired data according to instructions from the user program in the CPU (refer to 2-3 The User Program). Only one Read/Write Head (or Antenna) can be connected to the ID Sensor Unit. Data and error information can be monitored through a Handheld Programming Console connected to the ID Sensor Unit. The data is displayed on the screen of the Programming Console.
6
Page 22
System Connections
Section 1-5
C200H-IDS01-V1 Electromagnetic Induction ID Sensor ID Sensor Unit C200H
C200H
Data Carrier
Connecting Cable Read/Write Head
Read/Write data
Read/ Write Head Work piece
Movement
Work Hand-held Programming Console (Attach the keyboard accessory sheet, supplied with the ID Sensor Unit, to the Programming Console.)
C200H-IDS21 Microwave ID Sensor Unit ID Sensor Unit C200H
C200H
Data Carrier
Connecting Cable
Read/Write data
R/W Antenna Work piece
Movement
R/W Antenna Work
Hand-held Programming Console (Attach the keyboard accessory sheet, supplied with the ID Sensor Unit, to the Programming Console.)
1-5
System Connections
Mounting the ID Sensor Unit
As a Special I/O Unit, an ID Sensor Unit can be mounted to any slot on the C200H PC Backplane except the two rightmost slots; these two slots are reserved for peripheral devices. Up to ten Special I/O Units can be mounted to a PC system. (The PC Link Unit, used to link two PCs, is a Special I/O Unit.) The number of ID Sensor Units which can be connected may be limited by the size of the Backplane, the Power Supply, and the current consumption of each Unit. For details, refer to the C200H Programmable Controller Installation Guide.
Mounting to a Remote I/O Slave Rack
The maximum number of Special I/O Units that can be mounted to a Remote Slave Rack differs depending on the group (A, B, C, or D, as shown in the following table) to which they belong.
7
Page 23
System Connections
Section 1-5 The information in this table applies only when no other Special I/O Units are mounted to other Racks (PC or Expansion I/O Racks) and the Units in this table are mounted only to a Remote I/O Slave Rack. A High-speed Counter, Position Control Unit (NC111/NC112), ASCII Unit, Analog I/O Unit, ID Sensor Unit, Fuzzy Logic Unit 4 Units max.
B High-density I/O Units, Temperature Control Units, Cam Positioner Unit
C Temperature Sensor Unit, Voice Unit
D Position Control Unit (NC211)
---
---
---
-----
8 Units max. ---
--6 Units max.
-----
---
---
---
2 Units max.
When combining Units from groups A, B, C, and D, use the following formulae: 3A + B + 2C + 6D ≤ 12 A+B+C+D≤8 A maximum of ten Units can be mounted to one Remote I/O Slave Rack. However, when mounting ten Units, the NC211 Position Control Unit is counted as two Units and, if a PC Link Unit is used, it is counted as one Unit. Connecting the ID System
Refer to page 2 for an illustration of system connections. Before connecting and wiring the ID Sensor Unit, turn OFF the power to the PC. Connect the R/W Head or Antenna to the ID Sensor Unit connector marked “HEAD” or “Antenna”. (To disconnect the cable, pull while grasping the outer ring of the cable; do not pull at an angle.)
Connecting the Handheld Programming Console
Refer to 3-2 Monitoring for information on connecting the Handheld Programming Console.
The Next Step
Once you have completed installation of the ID Sensor system, turn to SECTION 2 Operation for details on setup and operation.
8
Page 24
Maximum Distance Between ID Sensor Unit and R/W Head
1-6
Section 1-6
Maximum Distance Between ID Sensor Unit and R/W Head
R/W Head
C500 IDS01-V1
IDS01-V2
C200 IDS02
IDS02-V1
IDS01
IDS01-V1
V600-H52 (V600-D23P52) (V600-D23P54) V600-H51 (V600-D23P61)
---
50.5 m
---
10 m
---
50.5 m
---
50.5 m
---
10 m
---
50.5 m
V600-H11 (V600-D23P72) (V600-D23P61) (V600-D2KR16) V600-H07 (V600-D23P71) (V600-D23P72)
---
50.5 m
---
10 m
---
50.5 m
30.5 m for lots manufactured in or after 1991 and 10 m for lots manufactured before 1991.
30.5 m
10 m
10 m
30.5 m for lots 30.5 m manufactured in or after 1992 and 10 m for lots manufactured before 1992.
V600-H06
10 m
30.5 m
10 m
10 m
10 m
30.5 m
Note With the C500-IDS02 (V1), the maximum cable length between the IDS02 (V1) and IDA02 is 200 m max. The length shown above is a distance between the IDA02 and the R/W Head.
1-7
Maximum Distance Between ID Sensor Unit and R/W Antenna R/W Antenna
C500 IDS21
V620-H01 (microwave)
10 m
C200H-IDS21 IDS22
10 m
10 m
Note With the C500-IDS22, the maximum cable length between the IDS22 and IDA22 is 200 m max. This length shown above is a distance between the IDA22 and the R/W Head.
9