The text of a manual · part 9 of 60
C200HX/C200HG/C200HE Programmable Controllers Operation Manual, pages 74 to 83
Pages 74 to 83 of 586
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron C200HE-CPU42-E
Page 74
Section 3-6
DM (Data Memory) Area
3-6
DM (Data Memory) Area The DM area is divided into various parts as described in the following table. A portion of UM (up to 3,000 words in 1,000-word increments) can be allocated as Expansion DM. Addresses DM 0000 to DM 0999 DM 1000 to DM 2599 DM 2600 to DM 5999 DM 6000 to DM 6030 DM 6100 to DM 6143 DM 6144 to DM 6599 DM 6600 to DM 6655 DM 7000 to DM 9999
Note
User read/write Read/Write
Read only
Usage Normal DM. Special I/O Unit Area1 Normal DM. History Log Reserved System Settings PC Setup Expansion DM2
1. The PC Setup can be set to use DM 7000 through DM 8599 as the Special I/O Area instead of DM 1000 to DM 2599. Refer to 3-6-4 PC Setup for details. When Special I/O Units are used, 100 words are occupied by each Unit, as follows: Unit #0: DM 1000 to DM 1099 Unit #1: DM 1100 to DM 1199 (...) Unit #9: DM 1900 to DM 1999 Unit #A: DM 2000 to DM 2099 (...) Unit #F: DM 2500 to DM 2599 2. The UM Area Allocation Programming Console operation can be used to allocate up to 3000 words of UM as Expansion DM. Although composed of 16-bit words like any other data area, data in the DM area cannot be specified by bit for use in instructions with bit operands. DM 0000 to DM 6143 can be written to by the program, but DM 6144 to DM 6655 can be overwritten only from a Peripheral Device, such as a Programming Console or computer with SSS. The DM area retains status during power interruptions. DM 6031 cannot be used in user applications because it is used by the system to store EM bank number information and indirect DM addresses.
Indirect Addressing
Normally, when the content of a data area word is specified for an instruction, the instruction is performed directly on the content of that word. For example, suppose MOV(21) is performed with DM 0100 as the first operand and LR 20 as the second operand. When this instruction is executed, the content of DM 0100 is moved to LR 20. Note Expansion DM cannot be used for indirect addressing. It is possible, however, to use indirect DM addresses as the operands for many instructions. To indicate an indirect DM address, is input with the address of the operand. With an indirect address, with content of this operand does not contain the actual data to be used. Instead, its contents is assumed to hold the address of another DM word, the content of which will actually be used in the instruction. If 0100 was used in our example above and the content of DM 0100 is 0324, then 0100 actually means that the content of DM 0324 is to
56
Page 75
Section 3-6
DM (Data Memory) Area be used as the operand in the instruction, and the content of DM 0324 will be moved to LR 00. MOV(21) 0100 LR 00
Indirect address
Word DM 0099 DM 0100 DM 0101
Content 4C59 0324 F35A
DM 0324 DM 0325 DM 0326
5555 2506 D541
Indicates DM 0324
5555 moved to LR 00.
3-6-1 Expansion DM Area The expansion DM area is designed to provide memory space for storing operating parameters and other operating data for Link Units and Special I/O Units. Up to 3,000 words of UM can be allocated as Expansion DM (in 1K-word increments) using the UM ALLOCATION operation in the Programming Console or SSS. Expansion DM area addresses run from DM 7000 to DM 9999. The data in the expansion DM area can be transferred to the Special I/O Unit Default Area (DM 1000 to DM 1999) when starting the PC or via programming instruction to easily change operating parameters, enabling rapid switching between control processes. The expansion DM area can also be used to store parameters for other devices connected in the PC system, e.g., Programmable Terminal character string or numeral tables. The expansion DM area is used to store operating parameters and cannot be used in programming like the normal DM area. Expansion DM can only be overwritten from a Peripheral Device, retains status during power interruptions, and cannot be used for indirect addressing. The UM area can be allocated as expansion DM area in increments of 1K words. Once expansion DM area has been created, it is saved and transferred as part of the program, i.e., no special procedures are required when saving or transferring the program. UM ALLOCATION Operation
1, 2, 3...
The procedure for the Programming Console’s UM ALLOCATION operation is shown below. Refer to 4-6-3 Clearing Memory for details on the DATA CLEAR and UM ALLOCATION instructions. 1. Clear memory. CLR
SET
NOT
RESET
EXT
MONTR
Note UM allocation is not possible unless memory is cleared first. 2. The expansion DM area can be set to 0, 1, 2, or 3 K words. The following key sequence creates a 2-KW expansion DM area (DM 7000 to DM 8999). CLR
FUN
VER
CHG
2
SET
9
7
1
3
WRITE
Press the 0 Key to eliminate the expansion DM area (0 KW). or Press the 1 Key to allocate DM 7000 to DM 7999 (1 KW). or Press the 2 Key to allocate DM 7000 to DM 8999 (2 KW). or Press the 3 Key to allocate DM 7000 to DM 9999 (3 KW).
57
Page 76
Section 3-6
DM (Data Memory) Area
3-6-2 Special I/O Unit Data Special I/O Units are allocated 1000 or 1600 words in the DM Area depending on the value set in word DM 6602 of the PC Setup. The DM 6602 setting determines whether the Special I/O Unit Data area is setup for 10 or 16 Units and whether the data is stored in read/write DM (DM 1000 to DM 2599) or read-only DM (DM 7000 to DM 8599). Refer to Appendix E for details. Unit 0 1 2 3 4 5 6 7 8 9 A B C D E F
Addresses DM 1000 to DM 1099 or DM 7000 to DM 7099 DM 1100 to DM 1199 or DM 7100 to DM 7199 DM 1200 to DM 1299 or DM 7200 to DM 7299 DM 1300 to DM 1399 or DM 7300 to DM 7399 DM 1400 to DM 1499 or DM 7400 to DM 7499 DM 1500 to DM 1599 or DM 7500 to DM 7599 DM 1600 to DM 1699 or DM 7600 to DM 7699 DM 1700 to DM 1799 or DM 7700 to DM 7799 DM 1800 to DM 1899 or DM 7800 to DM 7899 DM 1900 to DM 1999 or DM 7900 to DM 7999 DM 2000 to DM 2099 or DM 8000 to DM 8099 DM 2100 to DM 2199 or DM 8100 to DM 8199 DM 2200 to DM 2299 or DM 8200 to DM 8299 DM 2300 to DM 2399 or DM 8300 to DM 8399 DM 2400 to DM 2499 or DM 8400 to DM 8499 DM 2500 to DM 2599 or DM 8500 to DM 8599
Note These DM words can be used for other purposes when not allocated to Special I/O Units.
3-6-3 Error History Area DM 6000 to DM 6030 are used to store up to 10 records that show the nature, time, and date of errors that have occurred in the PC. The Error History Area will store system-generated or FAL(06)/FALS(07)-generated error codes whenever AR 0715 (Error History Enable Bit) is ON. Refer to Section 9 Troubleshooting for details on error codes. Area Structure
Error records occupy three words each stored between DM 6001 and DM 6030. The last record that was stored can be obtained via the content of DM 6000 (Error Record Pointer). The record number, DM words, and pointer value for each of the ten records are as follows: Record None 1 2 3 4 5 6 7 8 9 10
58
Addresses N.A. DM 6001 to DM 6003 DM 6004 to DM 6006 DM 6007 to DM 6009 DM 6010 to DM 6012 DM 6013 to DM 6015 DM 6016 to DM 6018 DM 6019 to DM 6021 DM 6022 to DM 6024 DM 6025 to DM 6027 DM 6028 to DM 6030
Pointer value 0000 0001 0002 0003 0004 0005 0006 0007 0008 0009 000A
Page 77
Section 3-6
DM (Data Memory) Area
Although each of them contains a different record, the structure of each record is the same: the first word contains the error code; the second and third words, the day and time. The error code will be either one generated by the system or by FAL(06)/FALS(07); the time and date will be the date and time from AR 18 and AR 19 (Calender/date Area). Also recorded with the error code is an indication of whether the error is fatal (08) or non-fatal (00). This structure is shown below. Word
Bit
First
00 to 07 08 to 15 00 to 07 08 to 15 00 to 07 08 to 15
Second Third
Content Error code 00 (non-fatal) or 80 (fatal) Seconds Minutes Hours Day of month
The following table lists the possible error codes and corresponding errors. Error severity Fatal errors
Non-fatal errors
Operation
Error code
Error
00
Power interruption
01 to 99 or 9F
System error (FALS)
C0 to C3
I/O bus error
E0
Input-output I/O table error
E1
Too many Units
F0
No END(01) instruction
F1
Memory error
01 to 99
System error (FAL)
8A
Interrupt Input error
8B
Interrupt program error
9A
Group 2 High-density I/O error
9B
PC Setup error
9C
Communications Board error
9D
UM Memory Cassette transfer error
B0 to B1
Remote I/O error
D0
Special I/O error
E7
I/O table verification error
F7
Battery error
F8
Cycle time overrun
When the first error code is generated with AR 0715 (Error History Enable Bit) turned ON, the relevant data will be placed in the error record after the one indicated by the History Record Pointer (initially this will be record 1) and the Pointer will be incremented. Any other error codes generated thereafter will be placed in consecutive records until the last one is used. Processing of further error records is based on the status of AR 0713 (Error History Overwrite Bit). If AR 0713 is ON and the Pointer contains 000A, the next error will be written into record 10, the contents of record 10 will be moved to record 9, and so on until the contents of record 1 is moved off the end and lost, i.e., the area functions like a shift register. The Record Pointer will remain set to 000A. If AR 0713 is OFF and the Pointer reaches 000A, the contents of the Error History Error will remain as it is and any error codes generate thereafter will not be recorded until AR 0713 is turned OFF or until the Error History Area is reset.
59
Page 78
Section 3-6
DM (Data Memory) Area
The Error History Area can be reset by turning ON and then OFF AR 0714 (Error History Reset Bit). When this is done, the Record Pointer will be reset to 0000, the Error History Area will be reset (i.e., cleared), and any further error codes will be recorded from the beginning of the Error History Area. AR 0715 (Error History Enable Bit) must be ON to reset the Error History Area.
3-6-4 PC Setup The PC Setup (DM 6600 through DM 6655) contains settings that determine PC operation. Data in the PC Setup can be changed with a Programming Console or SSS if UM is not write-protected by pin 1 of the CPU Unit’s DIP switch. Refer to page 20 for details on changing DIP switch pin settings. The data in DM 6600 through DM 6634 can be set or changed only when the PC is in PROGRAM mode. The data in DM 6635 through DM 6655 can be set or changed when the PC is in PROGRAM or MONITOR mode. The following words can be changed from the SYSMAC Support Software’s PC Setup menu. (The PC must be in PROGRAM mode.) 1, 2, 3...
1. Startup mode (DM 6600) 2. Startup mode designation (DM 6601) 3. Cycle monitor time (DM 6618) 4. Cycle time setting (DM 6619) 5. RS-232C Port Settings (DM 6645 through DM 6649) The PC can be operated with the default PC Setup, which requires changing only when customizing the PC’s operating environment to application needs. The PC Setup parameters are described in the following table. If there is an error in the settings in DM 6600 to DM 6655, a non-fatal error (error code 9B) will occur when the data is read by the PC and one of the flags from SR 27500 to SR 27502 will turn ON to indicate the location of the error. If there is an error in the settings in DM 6550 to DM 6559, a non-fatal error (error code 9C) will occur.
Word(s)
Bit(s)
Function
Default
Startup Processing (DM 6600 to DM 6612) The following settings are accessed only once when the PC is turned ON. DM 6600
00 to 07 08 to 15
DM 6601
00 to 07 08 to 11 12 to 15
60
Startup mode (effective when bits 08 to 15 are set to 02). 00: PROGRAM; 01: MONITOR 02: RUN Startup mode designation 00: Programming Console switch 01: Continue operating mode last used before power was turned off 02: Setting in 00 to 07
PROGRAM
Reserved IOM Hold Bit (SR 25212) Status 0: Reset; 1: Maintain Forced Status Hold Bit (SR 25211) Status 0: Reset; 1: Maintain
--Reset
Programming Console switch
Page 79
Section 3-6
DM (Data Memory) Area Word(s) DM 6602
Bit(s) 00 to 07 08 to 15
Function Not used. 00: C200H-compatible RAM Mode (Default) Use DM 1000 through DM 2599 for the initial data area for the Special I/O Unit Area. • Data in the Special I/O Unit Area can be read/written.
Default --DM 1000 to DM 2599
• The data cannot be converted to ROM. 01: C200H-compatible ROM Mode 1 Transfer the contents of DM 7000 through DM 7999 to DM 1000 through DM 1999 at startup and use DM 1000 through DM 1999. • The UM Area Allocation operation must be performed beforehand. • The data is compatible with C200H applications that use EEPROM/ EPROM. • ROM conversion is possible indirectly by writing DM 7000 through DM 7999 to ROM. 02: DM Linear Mode 1 Use DM 7000 through DM 7999 for the initial data area for Special I/O Unit Area. • The UM Area Allocation operation must be performed beforehand. • DM 1000 through DM 1999 can be used as regular DM. • DM 7000 through DM 7999 can be converted to ROM. 11: C200H-compatible ROM Mode 2 Transfer the contents of DM 7000 through DM 8599 to DM 1000 through DM 2599 at startup and use DM 1000 through DM 2599. • The UM Area Allocation operation must be performed beforehand. • ROM conversion is possible indirectly by converting DM 7000 through DM 8599 to ROM. 12: DM Linear Mode 2 Use DM 7000 through DM 8599 for the Special I/O Unit Area. • The UM Area Allocation operation must be performed beforehand. • DM 1000 through DM 2599 can be used as regular DM. • DM 7000 through DM 8599 can be converted to ROM. DM 6603 to DM 6604 DM 6605
00 to 15 00 to 07 08 to 15 00 to 15
See also 3-6-6 Special I/O Unit Area Settings. Not used. Momentary power interruption time (0 to 10 ms) Set the momentary power interruption time from 00 to 10 in BCD. Not used. Not used.
DM 6606 to DM 6612 Communications and Cycle Time Settings (DM 6613 to DM 6619)
The following settings are accessed only once when program execution begins. DM 6613 00 to 07 Servicing time for Communications Board port B (effective when bits 08 to 15 are set to 01) 00 to 99 (BCD): Percentage of cycle time used to service port B. 08 to 15
--0 ms -----
No setting (0000)
Minimum: 0.26 ms; maximum 58.254 ms Communications Board port B servicing setting enable 00: Do not set service time (Fixed at 5%, 0.26 ms min.) 01: Use time in 00 to 07. Service time is 10 ms when operation is stopped, regardless of this setting.
61
Page 80
DM (Data Memory) Area
Section 3-6
Word(s) DM 6614
Default No setting (0000)
Bit(s) 00 to 07
08 to 15
Function Servicing time for Communications Board port A (effective when bits 08 to 15 are set to 01) 00 to 99 (BCD): Percentage of cycle time used to service port A. Minimum: 0.26 ms; maximum 58.254 ms Communications Board port A servicing setting enable 00: Do not set service time (Fixed at 5%, 0.26 ms min.) 01: Use time in 00 to 07. Service time is 10 ms when operation is stopped, regardless of this setting.
DM 6615
00 to 15
Reserved
---
DM 6616
00 to 07
Servicing time for RS-232C port (effective when bits 08 to 15 are set to 01) 00 to 99 (BCD): Percentage of cycle time used to service RS-232C port.
No setting (0000)
Minimum: 0.228 ms; maximum 58.254 ms 08 to 15
(RS-232C port servicing setting enable) 00: Do not set service time (Fixed at 5%, 0.228 ms min.) 01: Use time in 00 to 07. Service time is 10 ms when operation is stopped, regardless of this setting.
DM 6617
00 to 07
Servicing time for peripheral port (effective when bits 08 to 15 are set to 01) 00 to 99 (BCD): Percentage of cycle time used to service peripheral.
No setting (0000)
Minimum: 0.26 ms; maximum 58.254 ms 08 to 15
Peripheral port servicing setting enable 00: Do not set service time (Fixed at 5%, 0.26 ms min.) 01: Use time in 00 to 07. Service time is 10 ms when operation is stopped, regardless of this setting.
DM 6618
00 to 07 08 to 15
DM 6619
00 to 15
Cycle monitor time (effective when bits 08 to 15 are set to 01, 02, or 03) 00 to 99 (BCD) × setting unit (see 08 to 15) Cycle monitor enable (Setting in 00 to 07 × setting unit; 99 s max.) 00: 120 ms (setting in bits 00 to 07 disabled) 01: Setting unit: 10 ms 02: Setting unit: 100 ms 03: Setting unit: 1 s
00
Cycle time 0000: Variable (no minimum) 0001 to 9999 (BCD): Minimum time in ms
Variable
00: 120 ms
Interrupt/Refresh Processing (DM 6620 to DM 6623) The following settings are accessed only once when program execution begins. DM 6620
00 to 09
10 to 11 12 to 15
62
Special I/O Unit cyclic refresh (Bit number corresponds to unit number, PC Link Units included) 0: Enable cyclic refresh and I/O REFRESH (IORF(97)) from main program 1: Disable (refresh only for I/O REFRESH from interrupt programs)
Enable
A setting of 01 (Disable) is valid only when the interrupt response is set to high-speed response mode. It is not valid for normal interrupt response or for Special I/O Units mounted in Slave Racks. Reserved --Interrupt response Normal 0:
Normal (C200H compatible) Interrupts cannot be received when Host Link servicing, execution of a single instruction, Remote I/O processing, or Special I/O processing is being performed. The interrupt subroutine will be executed after the processing is completed.
1:
High-speed Response (C200HS or C200HX/HG/HE) Interrupts will be received when Host Link servicing, execution of a single instruction, Remote I/O processing, or Special I/O processing is being performed. If there is an interrupt input, the current processing will be interrupted and the interrupt subroutine will be executed.
Page 81
Section 3-6
DM (Data Memory) Area Word(s) DM 6621
Bit(s) 00 to 07 08 to 15
Function
Default
Reserved Special I/O Unit refresh (PC Link Units included) 00: Enable refresh for all Special I/O Units 01: Disable refresh for all Special I/O Units (but, not valid on Slave Racks)
--Enable
A setting of 1 (Disable) is not valid for Special I/O Units mounted in Slave Racks. DM 6622
DM 6623
00 to 07
Scheduled interrupt time unit 00: 10 ms 01: 1 ms
10 ms (0000)
08 to 15
Scheduled interrupt time unit enable 00: Disable (10 ms) 01: Enable setting in 00 to 07
00 to 15
Special I/O Unit cyclic refresh (PC Link Units included) (Bit numbers 00 to 15 correspond to unit numbers 0 to F.) 0: Enable cyclic refresh and I/O REFRESH (IORF(97)) from main program 1: Disable (refresh only for I/O REFRESH from interrupt programs)
Enable
A setting of 01 (Disable) is valid only when the interrupt response is set to high-speed response mode. It is not valid for normal interrupt response or for Special I/O Units mounted in Slave Racks. Reserved ---
DM 6624 to 00 to 15 DM 6644 RS-232C Port Settings (DM 6645 to DM 6649)
The following settings are accessed continually while the PC is ON. DM 6645 00 to 03 Port settings 0: Standard (Host Link or peripheral bus serial communications mode, 1 start bit, 7-bit data, even parity, 2 stop bits, 9,600 bps) 1: Settings in DM 6646 04 to 07 CTS control setting 0: Disable CTS control 1: Enable CTS control 08 to 11
12 to 15
DM 6646
00 to 07 08 to 15
DM 6647
00 to 15
Words linked for 1:1 PC Link 0: LR 00 to LR 63; 1: LR 00 to LR 31; 2: LR 00 to LR 15 Maximum PT node number for 1:N NT Link 1 to 7 BCD (1 to 3 with a PC) Serial communications mode 0: Host Link; 1: RS-232C; 2: 1:1 PC Link slave; 3: 1:1 PC Link master; 4: 1:1 NT Link; 5: 1:N NT Link Baud rate 00: 1.2K, 01: 2.4K, 02: 4.8K, 03: 9.6K, 04: 19.2K Frame format Start Length Stop 00: 1 bit 7 bits 1 bit 01: 1 bit 7 bits 1 bit 02: 1 bit 7 bits 1 bit 03: 1 bit 7 bits 2 bit 04: 1 bit 7 bits 2 bit 05: 1 bit 7 bits 2 bit 06: 1 bit 8 bits 1 bit 07: 1 bit 8 bits 1 bit 08: 1 bit 8 bits 1 bit 09: 1 bit 8 bits 2 bit 10: 1 bit 8 bits 2 bit 11: 1 bit 8 bits 2 bit Transmission delay 0000 to 9999: BCD in 10-ms units.
Standard
Disable
LR 00 to LR 63
Host Link
1.2 K
Parity Even Odd None Even Odd None Even Odd None Even Odd None
1 start bit, 7-bit data, 1 stop bit, even parity
0 ms
63
Page 82
Section 3-6
DM (Data Memory) Area Word(s) DM 6648
Bit(s) 00 to 07 08 to 11 12 to 15
DM 6649
00 to 07 08 to 15
Function Node number (Host Link) 00 to 31 (BCD) Start code enable (RS-232C) 0: Disable; 1: Set End code enable (RS-232C) 0: Disable (number of bytes received) 1: Set (specified end code) 2: CR, LF Start code (RS-232C) 00 to FF (binary) 12 to 15 of DM 6648 set to 0: Number of bytes received 00: Default setting (256 bytes) 01 to FF: 1 to 255 bytes
Default 0 Disabled Disabled
Not used (0000)
12 to 15 of DM 6648 set to 1: End code (RS-232C) 00 to FF (binary) Peripheral Port Settings (DM 6650 to DM 6654) The following settings are accessed continually while the PC is ON. Note To use the peripheral port set to Host Link mode after using it in peripheral bus mode, turn OFF the power once and turn ON again or disconnect and reconnect the cable. DM 6650
00 to 03
04 to 11 12 to 15 DM 6651
00 to 07 08 to 15
DM 6652
00 to 15
DM 6653
00 to 07 08 to 11 12 to 15
64
Port settings 0: Standard (Host Link or peripheral bus serial communications mode, 1 start bit, 7-bit data, even parity, 2 stop bits, 9,600 bps) 1: Settings in DM 6651 Reserved Serial communications mode 0: Host Link; 1: No-protocol Baud rate 00: 1.2K, 01: 2.4K, 02: 4.8K, 03: 9.6K, 04: 19.2K Frame format Start Length Stop Parity 00: 1 bit 7 bits 1 bit Even 01: 1 bit 7 bits 1 bit Odd 02: 1 bit 7 bits 1 bit None 03: 1 bit 7 bits 2 bit Even 04: 1 bit 7 bits 2 bit Odd 05: 1 bit 7 bits 2 bit None 06: 1 bit 8 bits 1 bit Even 07: 1 bit 8 bits 1 bit Odd 08: 1 bit 8 bits 1 bit None 09: 1 bit 8 bits 2 bit Even 10: 1 bit 8 bits 2 bit Odd 11: 1 bit 8 bits 2 bit None Transmission delay (Host Link) 0000 to 9999: in 10-ms units. Node number (Host Link) 00 to 31 (BCD) Start code enable (RS-232C) 0: Disable; 1: Set End code enable (RS-232C) 0: Disable (number of bytes received) 1: Set (specified end code) 2: CR, LF
Standard
--Host Link 1.2 K 1 start bit, 7-bit data, 1 stop bit, even parity
0 ms 0 Disable Disable
Page 83
Section 3-6
DM (Data Memory) Area Word(s) DM 6654
Bit(s) 00 to 07 08 to 15
Function
Default 0000
Start code (RS-232C) 00 to FF (binary) 12 to 15 of DM 6653 set to 0: Number of bytes received 00: Default setting (256 bytes) 01 to FF: 1 to 255 bytes 12 to 15 of DM 6653 set to 1: End code (RS-232C) 00 to FF (binary)
Error Settings (DM 6655) The following settings are accessed continually while the PC is ON. DM 6655 00 to 03 Interrupt programming error enable 0: Detect interrupt programming errors 1: Do not detect
Detect
04 to 07 08 to 11
Reserved Cycle time monitor enable 0: Detect long cycles as non-fatal errors 1: Do not detect long cycles
--Detect
12 to 15
Low battery error enable 0: Detect low battery voltage as non-fatal error 1: Do not detect low battery voltage
Detect
3-6-5 Communications Board Settings DM 6550 through DM 6554 contain the communications settings for Communications Board port B and DM 6555 through DM 6559 contain the communications settings for Communications Board port A. Word(s)
Bit(s)
Function
Default
Communications Board Port B Settings (DM 6550 to DM 6554) The following settings are accessed continually while the PC is ON. DM 6550 00 to 03 Port settings 0: Standard (1 start bit, 7-bit data, even parity, 2 stop bits, 9,600 bps) 1: Settings in DM 6551
Standard
04 to 07
CTS control setting 0: Disable CTS control 1: Enable CTS control
Disable
08 to 11
Words linked for 1:1 PC Link (Cannot be changed once set in the 1:1 PC Link Master.) 0: LR 00 to LR 63; 1: LR 00 to LR 31; 2: LR 00 to LR 15
LR 00 to LR 63
Maximum PT node number for 1:N NT Link 1 to 7 BCD (1 to 3 with a 12 to 15
PC)
Communications mode 0: Host Link; 1: RS-232C; 2: 1:1 PC Link slave; 3: 1:1 PC Link master; 4: 1:1 NT Link; 5: 1:N NT Link; 6: Protocol Macro
Host Link
65