Manual · Omron
SYSMAC CJ Series CJ2H-CPU6_-EIP, CJ2H-CPU6_, CJ2M-CPU_ CJ2 CPU Unit Hardware User's Manual
Manual422 pagesPDF 14 MB
Hardware user's manual for the Omron SYSMAC CJ-series CJ2H and CJ2M CPU Units: configuration, installation, wiring and maintenance.
What this file really is
The old site listed this file as “CPU Manual” for the Omron C200H-OD21A, CQM1-ID211 and 3 more models. Linked as a CPU manual for CQM1 I/O modules such as the CQM1-ID211, this is the hardware user's manual for the CJ-series CJ2 CPU Units and does not name the CQM1 modules.
Filed with · 5 models
Also filed with these models on the old site
Summary
What is in it
Omron's hardware user's manual for the SYSMAC CJ-series CJ2 CPU Units (CJ2H-CPU6@-EIP, CJ2H-CPU6@, CJ2M-CPU3@ and CJ2M-CPU1@). It gives an overview and specifications, the basic system configuration, part names and functions of the CPU Unit and Configuration Units, connecting Support Software by USB, RS-232C or Ethernet, installation and wiring, troubleshooting, inspection and battery replacement, and backing up PLC data. Appendices cover Basic I/O Unit specifications, dimensions and error details.
Its parts
- Overview
- Basic System Configuration and Devices
- Nomenclature and Functions
- Support Software
- Installation
- Troubleshooting
- Inspection and Maintenance
- Backup Operations
From the manual
Key facts from this manual
Each line names its page in the PDF.
Omron SYSMAC CJ Series CJ2 CPU Unit Hardware User's Manual for the CJ2H-CPU6@-EIP, CJ2H-CPU6@, CJ2M-CPU3@ and CJ2M-CPU1@ CPU Units. It does not name the CQM1 or C200H units the site files it under. It gives specifications, system devices, installation, troubleshooting, battery replacement and backup.
- Covers
- CJ-series CJ2 CPU Units CJ2H-CPU6@-EIP, CJ2H-CPU6@, CJ2M-CPU3@ and CJ2M-CPU1@ p. 7
- Ports
- USB on all; built-in EtherNet/IP port on CJ2H-CPU6@-EIP and CJ2M-CPU3@ only p. 44
- Serial option
- CJ2M-CPU3@: an RS-232C or RS-422A/485 Option Board can be added p. 44
- Pulse I/O
- CJ2M (unit version 2.0 or later): optional Pulse I/O Modules for up to four axes p. 44
- Current draw
- CJ2H-CPU6@-EIP: 5 VDC, 0.82 A; CJ2H-CPU6@: 5 VDC, 0.42 A p. 55
- Dimensions
- CJ2H-CPU6@-EIP: 90 x 65 x 80 mm; CJ2H-CPU6@: 90 x 65 x 49 mm (H x D x W) p. 55
- Weight
- CJ2H-CPU6@-EIP: 280 g or less; CJ2H-CPU6@: 190 g or less p. 55
- Environment
- 0 to 55°C; 10% to 90% humidity with no condensation p. 55
- Battery
- CJ1W-BAT01 Battery Set; life 5 years at 25°C p. 55, 236
- Memory Card
- OMRON-specified HMC-EF583, HMC-EF283 or HMC-EF183; 128 MB, 256 MB or 512 MB; FAT16 p. 57, 113
- Expansion
- Up to 3 Expansion Racks; 10 Units per rack, 40 Units per PLC p. 56
- Languages
- Ladder Logic, Sequential Function Charts, Structured Text, Instruction Lists p. 57
- Power Supply Units
- CJ1W-PA205R, CJ1W-PA205C, CJ1W-PA202, CJ1W-PD025, CJ1W-PD022; 100 to 240 VAC or 24 VDC input p. 121
- Support software
- CX-One package, including CX-Programmer p. 80, 134
What this manual walks you through
- General and performance specifications of the CJ2 CPU Units p. 55, 56, 57
- Memory Card models, indicators and simple backup p. 113
- Power Supply Unit specifications p. 121
- CX-One support software p. 134
- Reading the CPU Unit indicators to find an error p. 198
- Reading error status and the error log with the CX-Programmer p. 199
- Replacing the backup battery p. 235, 236
Good to know
- Use OMRON-specified Memory Cards; cards from other companies may not operate correctly. p. 113
- Install a replacement battery within two years of the production date on its label. p. 236
- After a low-battery error, the battery fails in about 5 days at 25°C, sooner at higher temperatures. p. 236
- Battery errors are detected only if the Detect Low Battery parameter is set in the PLC Setup. p. 236
- Without a working battery, the internal clock stops and held I/O memory is lost at power off. p. 235
Questions this manual answers
What battery does a CJ2 CPU Unit take?
The CJ1W-BAT01 Battery Set, with a life of 5 years at 25°C. p. 55, 236
What does a flashing ERR/ALM light mean on a CJ2 CPU?
Flashing red is a non-fatal error; lit red is a fatal error. p. 198
Which CJ2 CPU Units have EtherNet/IP built in?
The CJ2H-CPU6@-EIP and the CJ2M-CPU3@. p. 44
Where is the CJ2 error code stored?
In word A400. If several errors occur at once, the most serious code is stored there. p. 199
Contents
Chapters and sections
Each line opens the PDF at its page.
- Title1
- Introduction7
- CJ2 CPU Unit Manuals8
- Manual Structure11
- Sections in this Manual13
- Safety Precautions23
- Application Precautions27
- Operating Environment Precautions32
- Regulations and Standards33
- Section 1 Overview43
- Section 2 Basic System Configuration and Devices71
- Section 3 Nomenclature and Functions101
- Section 4 Support Software133
- Section 5 Installation145
- Section 6 Troubleshooting197
- Section 7 Inspection and Maintenance231
16 more lines, from page 240 on
- 7-3 Power Supply Unit Replacement Time240
- Section 8 Backup Operations247
- Appendices263
- A-1 Specifications of Basic I/O Units264
- A-2 Dimensions356
- A-3 Fatal and Non-fatal Error Details365
- A-4 Connecting to a Serial Port on the CPU Unit373
- A-5 Installing the USB Driver401
- A-6 Load Short-circuit Protection and Line Disconnection Detection for Basic I/O Units411
- A-7 Relay Output Noise Reduction Methods415
- A-8 Functions Supported for Unit Versions417
- Index419
- Revision History421
The whole text · 48 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Title1-6
- Introduction7-13
- CONTENTS14-22
- Safety Precautions23-26
- Application Precautions27-31
- Pages 32 to 4232-42
- Section 1 Overview, pages 43 to 5243-52
- Section 1 Overview, pages 53 to 6253-62
- Section 1 Overview, pages 63 to 7063-70
- Section 2 Basic System Configuration and Devices, pages 71 to 8071-80
- Section 2 Basic System Configuration and Devices, pages 81 to 9081-90
- Section 2 Basic System Configuration and Devices, pages 91 to 10091-100
- Section 3 Nomenclature and Functions, pages 101 to 108101-108
- Section 3 Nomenclature and Functions, pages 109 to 116109-116
- Section 3 Nomenclature and Functions, pages 117 to 124117-124
- Section 3 Nomenclature and Functions, pages 125 to 132125-132
- Section 4 Support Software133-144
- Section 5 Installation, pages 145 to 153145-153
- Section 5 Installation, pages 154 to 162154-162
- Section 5 Installation, pages 163 to 171163-171
- Section 5 Installation, pages 172 to 180172-180
- Section 5 Installation, pages 181 to 189181-189
- Section 5 Installation, pages 190 to 196190-196
- Section 6 Troubleshooting, pages 197 to 205197-205
- Section 6 Troubleshooting, pages 206 to 214206-214
- Section 6 Troubleshooting, pages 215 to 223215-223
- Section 6 Troubleshooting, pages 224 to 230224-230
- Section 7 Inspection and Maintenance, pages 231 to 238231-238
- Section 7 Inspection and Maintenance, pages 239 to 246239-246
- Section 8 Backup Operations, pages 247 to 254247-254
- Section 8 Backup Operations, pages 255 to 262255-262
- Appendices, pages 263 to 272263-272
- Appendices, pages 273 to 282273-282
- Appendices, pages 283 to 292283-292
- Appendices, pages 293 to 302293-302
- Appendices, pages 303 to 312303-312
- Appendices, pages 313 to 322313-322
- Appendices, pages 323 to 332323-332
- Appendices, pages 333 to 342333-342
- Appendices, pages 343 to 352343-352
- Appendices, pages 353 to 362353-362
- Appendices, pages 363 to 372363-372
- Appendices, pages 373 to 382373-382
- Appendices, pages 383 to 392383-392
- Appendices, pages 393 to 402393-402
- Appendices, pages 403 to 412403-412
- Appendices, pages 413 to 418413-418
- Pages 419 to 422419-422