Page 7
Introduction Thank you for purchasing a CJ-series CJ2H-CPU6@(-EIP) or CJ2M-CPU@@ Programmable Controller. This manual contains information required to use the CJ2H-CPU6@(-EIP) and CJ2M-CPU@@. Please thoroughly read and understand this manual before you use the CJ2H-CPU6@(-EIP).
Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). • Personnel in charge of installing FA systems • Personnel in charge of designing FA systems. • Personnel in charge of managing FA systems and facilities.
Applicable Products CJ-series CJ2 CPU Units • CJ2H-CPU6@-EIP • CJ2H-CPU6@ • CJ2M-CPU3@ • CJ2M-CPU1@ In this manual, the following notation is used to indicate the CPU Units. • CJ2H-CPU6@(-EIP): Indicates the CJ2H-CPU6@-EIP and CJ2H-CPU6@ CPU Units. • CJ2M-CPU@@: Indicates the CJ2M-CPU3@ and CJ2M-CPU1@ CPU Units. Optional Pulse I/O Modules can be used for pulse I/O with a CJ2M CPU Unit. CJ2 Series
NSJ Series
CJ2 CPU Units
NSJ Controllers
CJ2H CPU Units
NSJ5-TQ@@(B)-G5D
CS1H-CPU@@H
NSJ5-SQ@@(B)-G5D
CS1G-CPU@@H
CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M CPU Units
NSJ10-TV@@(B)-G5D NSJ12-TS@@(B)-G5D
NSJ Controllers NSJ5-TQ@@(B)-M3D NSJ5-SQ@@(B)-M3D
CJ1-H CPU Units
CS1-H CPU Units
NSJ8-TV@@(B)-G5D
CJ2M-CPU3@ CJ2M-CPU1@ Pulse I/O Module for CJ2M CPU Units
CS Series
NSJ8-TV@@(B)-M3D
CS1D CPU Units CS1D CPU Units for Duplex Systems CS1D-CPU@@H CS1D CPU Units for Simplex Systems CS1D-CPU@@S CS1D Process-control CPU Units
CJ1H-CPU@@H-R
CS1D-CPU@@P
CJ1H-CPU@@H CJ1G-CPU@@H CJ1G -CPU@@P (Loop CPU Units)
CS1 CPU Units CS1H-CPU@@(-V)
CJ1M CPU Units
CS1G-CPU@@(-V)
CJ1M-CPU@@ CS-series Basic I/O Units
CJ1 CPU Units
CS-series Special I/O Units
CJ1G-CPU@@
CJ-series Basic I/O Units
NSJ-series Expansion Units
CS-series CPU Bus Units CS-series Power Supply Units
CJ-series Special I/O Units
Note: A special Power Supply Unit must be used for CS1D CPU Units.
CJ-series CPU Bus Units CJ-series Power Supply Units
CJ2 CPU Unit Hardware User’s Manual
1
Page 8
CJ2 CPU Unit Manuals Information on the CJ2 CPU Units is provided in the following manuals. Refer to the appropriate manual for the information that is required. This Manual
Mounting CJ-series CJ2 CPU Unit and Setting Hardware User’s Manual 1 Hardware (Cat. No. W472)
CJ-series CJ2 CPU Unit Software User’s Manual (Cat. No. W473)
CS/CJ/NSJ Series Instructions Reference Manual (Cat. No. W474)
• Unit part names and specifications • Basic system configuration • Unit mounting procedure • Setting procedure for DIP switch and rotary switches on the front of the CPU Unit
2 Wiring
• Specifications and wiring of Pulse I/O Modules • Available pulse I/O functions and allocations
For details on built-in EtherNet/IP port, refer to the EtherNet/IP Unit Operation Manual (W465)
• Wiring the Power Supply Unit Connecting • Wring Basic I/O Units and external I/O Online to devices
• Pulse I/O Module specifications • Wiring methods between Pulse I/O Modules and external I/O devices
3 the PLC
CX-Programmer Support Software Connecting Cables
Software 4 Setup
Procedures for connecting the CX-Programmer Support Software Software setting methods for the CPU Unit (including I/O memory allocation, PLC Setup settings, Special I/O Unit parameters, CPU Bus Unit parameters, and routing tables.)
Creating the 5 Program
For details on built-in EtherNet/IP port, refer to the EtherNet/IP Unit Operation Manual (W465).
• Program types and basic information • CPU Unit operation • Internal memory • Data management using file memory in the CPU Unit • Built-in CPU functions • Settings
Checking and Debugging 6 Operation
Maintenance and 7 Troubleshooting
CJ2M CPU Unit Pulse I/O Module User's Manual (Cat. No. W486)
Detailed information on programming instructions
Software setting procedures for Pulse I/O Modules (I/O memory allocations and PLC Setup settings)
Pulse I/O functions
• Checking I/O wiring, setting the Auxiliary Area settings, and performing trial operation • Monitoring and debugging with the CX-Programmer
Error codes and remedies if a problem occurs
2
CJ2 CPU Unit Hardware User’s Manual
Page 9
Manual Configuration The CJ2 CPU manuals are organized in the sections listed in the following tables. Refer to the appropriate section in the manuals as required.
Hardware User’s Manual (Cat. No. W472) (This Manual) Section Section 1 Overview
Content This section gives an overview of the CJ2 CPU Units and describes the features and specifications.
Section 2 Basic System Configuration and Devices
This section describes the system configuration for the CJ2 CPU Unit.
Section 3 Nomenclature and Functions
This section describes the part names and functions of the CPU Unit and Configuration Units.
Section 4 Support Software
This section describes the types of Support Software to use to perform programming and debugging and how to connect the PLC to the Support Software.
Section 5 Installation
This section describes the installation locations and how to wire CPU Units and Configuration Units.
Section 6 Troubleshooting
This section describes how to check the status for errors that occur during system operation and the remedies for those errors.
Section 7 Inspection and Maintenance
This section describes periodic inspection, the service life of the Battery and Power Supply Unit, and how to replace the Battery.
Section 8 Backup Operations
This section describes the procedure to back up PLC data.
Appendices
The appendices provide Unit dimensions, details on fatal and non-fatal errors, information on connecting to serial ports on the CPU Unit, the procedure for installing the USB driver on a computer, and information on load short-circuit protection and line disconnection detection.
Software User’s Manual (Cat. No. W473) Section Section 1 Overview
Content This section gives an overview of the CJ2 CPU Units and describes the features and specifications.
Section 2 Internal Memory in the CPU Unit
This section describes the types of memory in the CPU Unit and the data that is stored.
Section 3 CPU Unit Operation
This section describes the internal operation of the CPU Unit.
Section 4 CPU Unit Initialization
This section describes the initial setup of the CPU Unit.
Section 5 Understanding Programming
This section describes program types and programming details, such as symbols and programming instructions.
Section 6 I/O Memory Areas
This section describes the I/O memory areas in the CPU Unit.
Section 7 File Operations
This section describes the files that can be stored in the CPU Unit, the storage destination for those files, and file operations.
Section 8 I/O Allocations and Unit Settings
This section describes the I/O allocations used to exchange data between the CPU Unit and other Units.
Section 9 PLC Setup
This section describes details on the PLC Setup settings, which are used to perform basic settings for the CPU Unit.
Section 10 CPU Unit Functions
This section describes functions that are built into the CPU Unit.
Section 11 Programming Devices and Communications
This section describes the procedure for connecting the CJ2 CPU Unit to the CX-Programmer or other Support Software and to other devices.
Section 12 CPU Unit Cycle Time
This section describes how to monitor and calculate the cycle time.
Appendices
The appendices provide information on programming instructions, execution times, number of steps, Auxiliary Area words and bits, a memory map of the continuous PLC memory addresses, I/O memory operation when power is interrupted, and a comparison of CJ-series and CS-series PLCs.
CJ2 CPU Unit Hardware User’s Manual
3
Page 10
Instructions Reference Manual (Cat. No. W474) Section
Content
Section 1 Basic Understanding of Instructions
This section provides basic information on designing ladder programs for a CS/CJ/NSJseries CPU Unit.
Section 2 Summary of Instructions
This section provides a summary of instructions used with a CS/CJ/NSJ-series CPU Unit.
Section 3 Instructions
This section describes the functions, operands and sample programs of the instructions that are supported by a CS/CJ/NSJ-series CPU Unit.
Section 4 Instruction Execution Times and Number of Steps
This section provides the instruction execution times for each CS/CJ/NSJ-series CPU Unit instruction.
Appendices
The appendices provide a list of instructions by function code and by mnemonic and an ASCII table for the CS/CJ/NSJ-series CPU Units.
Pulse I/O Module User's Manual (Cat. No. W486) Section
4
Content
Section 1 Overview
This section gives an overview of the Pulse I/O Modules and the pulse I/O functions of the CJ2M.
Section 2 I/O Application Procedures and Function Allocations
This section lists the pulse functions of the CJ2M CPU Units and describes the overall application flow and the allocation of the functions.
Section 3 I/O Specifications and Wiring for Pulse I/O Modules
This section provides the I/O specifications and describes the wiring of the Pulse I/O Module.
Section 4 General-purpose I/O
This section describes the general-purpose I/O.
Section 5 Quick-response Inputs
This section describes the quick-response function that can be used to input signals that are shorter than the cycle time.
Section 6 Interrupts
This section describes the interrupt input function.
Section 7 High-speed Counters
This section describes the high-speed counter inputs and high-speed counter interrupts.
Section 8 Pulse Outputs
This section describes positioning functions, such as trapezoidal control, S-curve control, jogging, and origin search functions.
Section 9 PWM Outputs
This section describes the variable-duty-factor (PWM) outputs.
Appendices
The appendices provide a table of flag changes for pulse outputs, a comparison table with other models, and a performance table.
CJ2 CPU Unit Hardware User’s Manual
Page 11
Manual Structure Page Structure The following page structure is used in this manual. Level 1 heading Level 2 heading Level 3 heading
5 Installation
Level 2 heading
5-2
Installation
Level 3 heading
5-2-1
Connecting PLC Components
Gives the current headings.
The Units that make up a CJ-series PLC can be connected simply by pressing the Units together and locking the sliders by moving them toward the back of the Units. The End Cover is connected in the same way to the Unit on the far right side of the PLC.
A step in a procedure
1. Join the Units so that the connectors fit exactly. Hook
Hook holes Connector
5-2 Installation
5 toward the back of the Units as shown below until they click into place. Move the sliders toward the back until they lock into place.
Lock Release
Slider
Special Information (See below.)
Manual name
5 - 2 - 1 C o n n e c t i n g PL C C o m p o n e n t s
2. The yellow sliders at the top and bottom of each Unit lock the Units together. Move the sliders
Page tab Gives the number of the section.
Precautions for Correct Use If the locking tabs are not secured properly, the connectors may become loose and not function properly. Be sure to slide the locking tabs until they are securely in place.
CJ2 CPU Unit Hardware User’s Manual
5-13
This illustration is provided only as a sample and may not literally appear in this manual.
Special Information Special information in this manual is classified as follows:
Precautions for Safe Use Precautions on what to do and what not to do to ensure using the product safely. Precautions for Correct Use Precautions on what to do and what not to do to ensure proper operation and performance. Additional Information Additional information to increase understanding or make operation easier.
CJ2 CPU Unit Hardware User’s Manual
5
Page 12
6
CJ2 CPU Unit Hardware User’s Manual
Page 13
Sections in this Manual
1
Overview
2
Basic System Configuration and Devices
1 2 3
3
Nomenclature and Functions
4
4
Support Software
5
5
Installation
6
Troubleshooting
7
7
Inspection and Maintenance
8
8
Backup Operations
A
Appendices
6
A
CJ2 CPU Unit Hardware User’s Manual
7