Page 32
Operating Environment Precautions z Follow the instructions in this manual to correctly perform installation.
z Do not operate the control system in the following locations: • Locations subject to direct sunlight. • Locations subject to temperatures or humidity outside the range specified in the specifications. • Locations subject to condensation as the result of severe changes in temperature. • Locations subject to corrosive or flammable gases. • Locations subject to dust (especially iron dust) or salts. • Locations subject to exposure to water, oil, or chemicals. • Locations subject to shock or vibration.
z Take appropriate and sufficient countermeasures when installing systems in the following locations: • Locations subject to static electricity or other forms of noise. • Locations subject to strong electromagnetic fields. • Locations subject to possible exposure to radioactivity. • Locations close to power supplies.
26
CJ2 CPU Unit Hardware User’s Manual
Page 33
Regulations and Standards Conformance to EC Directives Applicable Directives • EMC Directives • Low Voltage Directive
Concepts z EMC Directives OMRON devices that comply with EC Directives also conform to the related EMC standards so that they can be more easily built into other devices or the overall machine. The actual products have been checked for conformity to EMC standards (see the following note). Whether the products conform to the standards in the system used by the customer, however, must be checked by the customer. EMC-related performance of the OMRON devices that comply with EC Directives will vary depending on the configuration, wiring, and other conditions of the equipment or control panel on which the OMRON devices are installed. The customer must, therefore, perform the final check to confirm that devices and the overall machine conform to EMC standards. * Applicable EMC (Electromagnetic Compatibility) standards are as follows: EMS (Electromagnetic Susceptibility): CS Series: EN 61131-2 and EN 61000-6-2 CJ Series: EN 61000-6-2 * EMI (Electromagnetic Interference): EN 61000-6-4 (Radiated emission: 10-m regulations)
z Low Voltage Directive Always ensure that devices operating at voltages of 50 to 1,000 VAC and 75 to 1,500 VDC meet the required safety standards for the PLC (EN 61131-2).
z Conformance to EC Directives The CJ-series PLCs comply with EC Directives. To ensure that the machine or device in which the CJ-series PLC is used complies with EC Directives, the PLC must be installed as follows: • The CJ-series PLC must be installed within a control panel. • You must use reinforced insulation or double insulation for the DC power supplies connected to DC Power Supply Units and I/O Units. • CJ-series PLCs complying with EC Directives also conform to the Common Emission Standard (EN 61000-6-4). Radiated emission characteristics (10-m regulations) may vary depending on the configuration of the control panel used, other devices connected to the control panel, wiring, and other conditions. You must therefore confirm that the overall machine or equipment complies with EC Directives.
CJ2 CPU Unit Hardware User’s Manual
27
Page 34
Conformance to Shipbuilding Standards This product conforms to the following shipbuilding standards. Applicability to the shipbuilding standards is based on certain usage conditions. It may not be possible to use the product in some locations. Contact your OMRON representative before attempting to use a PLC on a ship.
Usage Conditions for NK and LR Shipbuilding Standards z Usage Conditions for Applications Other Than on the Bridge or Deck • The PLC must be installed in a control panel. • Gaps in the door to the control panel must be completely filled or covered with gaskets or other material.
z Usage Conditions for Bridge and Deck (Certified Only by NK) • The PLC must be installed in a control panel. • Gaps in the door to the control panel must be completely filled or covered with gaskets or other material. • The following noise filter must be connected to the power supply line. Noise Filter Manufacturer Model
Cosel Co., Ltd. TAH-06-683
Trademarks SYSMAC is a registered trademark for Programmable Controllers made by OMRON Corporation. CX-One is a registered trademark for Programming Software made by OMRON Corporation. Windows is a registered trademark of Microsoft Corporation. Other system names and product names in this document are the trademarks or registered trademarks of their respective companies.
28
CJ2 CPU Unit Hardware User’s Manual
Page 35
Unit Versions of CJ2 CPU Units Unit Versions A “unit version” has been introduced to manage CJ2 CPU Units according to differences in functionality accompanying version upgrades.
Notation of Unit Versions on Products The unit version is given to the right of the lot number on the nameplate of the products for which unit versions are being managed, as shown below. CJ2 CPU Unit
CJ2H-CPU68-EIP CPU UNIT
Indicates the unit version of the CPU Unit (example: unit version 1.1).
Lot No.
Lot No. 090115 0008 CPU.Ver.1.1 EIP.Ver.1.1 OMRON Corporation
Indicates the unit version of the built-in EtherNet/IP port (CJ2H-CPU6@-EIP only) (example: unit version 1.1).
MADE IN JAPAN
Confirming Unit Versions with Support Software CX-Programmer can be used to confirm the unit version using one of the following two methods. • Using the PLC Information • Using the Unit Manufacturing Information (This method can be used for Special I/O Units and CPU Bus Units as well.)
z PLC Information
1 Use one of the following methods to display the PLC Information Dialog Box. • If you know the device type and CPU type, select them in the Change PLC Dialog Box, go online, and select PLC - Edit - Information from the menus. • If you don't know the device type and CPU type, but are connected directly to the CPU Unit on a serial line, select PLC - Auto Online to go online, and then select PLC - Edit - Information from the menus.
CJ2 CPU Unit Hardware User’s Manual
29
Page 36
2 In either case, the following PLC Information Dialog Box will be displayed.
Unit version
Use the above display to confirm the unit version of the CPU Unit.
z Unit Manufacturing Information
1 In the IO Table Window, right-click and select Unit Manufacturing information - CPU Unit.
30
CJ2 CPU Unit Hardware User’s Manual
Page 37
2 The following Unit Manufacturing information Dialog Box will be displayed.
Unit version
Use the above display to confirm the unit version of the CPU Unit connected online.
3 Using the Unit Version Labels The following unit version labels are provided with the CPU Unit.
Ver. 1.0 Ver. 1.0
These labels can be attached to the front of previous CPU Units to differentiate between CPU Units of different unit versions.
CJ2 CPU Unit Hardware User’s Manual
31
Page 38
Unit Versions Item CJ2H CPU Unit
Models CJ2H-CPU6@-EIP
Unit version Unit version 1.0 (Built-in EtherNet/IP section: Unit version 2.0) Unit version 1.1 (Built-in EtherNet/IP section: Unit version 2.0) Unit version 1.2 (Built-in EtherNet/IP section: Unit version 2.0) Unit version 1.3 (Built-in EtherNet/IP section: Unit version 2.0)
CJ2H-CPU6@
Unit version 1.1 Unit version 1.2 Unit version 1.3
CJ2M CPU Unit
CJ2M-CPU3@
Unit version 1.0 (Built-in EtherNet/IP section: Unit version 2.0) Unit version 2.0 (Built-in EtherNet/IP section: Unit version 2.0) Unit version 2.0 (Built-in EtherNet/IP section: Unit version 2.1)
CJ2M-CPU1@
Unit version 1.0 Unit version 2.0
32
CJ2 CPU Unit Hardware User’s Manual
Page 39
Unit Versions and Programming Devices The following tables show the relationship between unit versions and CX-Programmer versions. Refer to A-8 Functions Supported for Unit Versions for the functions supported by each unit version.
z Unit Versions and Programming Devices Required Programming Device CPU Unit
CJ2H
Ver. 7.1 or lower
Ver. 8.0
Ver. 8.2 or higher
Ver. 9.0
Ver. 9.1
Ver. 9.12 or higher
Programming Console ---*3
CJ2H-CPU6@-EIP Unit version 1.0
Functions for unit version 1.0
---
OK
OK
OK
OK
OK
CJ2H-CPU6@-EIP Unit version 1.1
Functions added for unit version 1.1
Using new functions
---
---
OK*2
OK
OK
OK
Not using new functions
---
OK*1
OK
OK
OK
OK
Using new functions
---
---
OK*2
OK
OK
OK
Not using new functions
---
---
OK
OK
OK
OK
Functions added for unit version 1.2
Using new functions
---
---
---
OK
OK
OK
Not using new functions
---
OK*1
OK*1
OK
OK
OK
Functions added for unit version 1.2
Using new functions
---
---
---
OK
OK
OK
Not using new functions
---
OK*1
OK*1
OK
OK
OK
Functions added for unit version 1.3
Using new functions
---
---
---
---
OK
OK
Not using new functions
---
OK*1
OK*1
OK
OK
OK
Functions added for unit version 1.3
Using new functions
---
---
---
---
OK
OK
Not using new functions
---
OK*1
OK*1
OK
OK
OK
CJ2M-CPU@@ Unit version 1.0
Functions for unit version 1.0
---
---
---
---
OK
OK
CJ2M-CPU@@ Unit version 2.0
Functions added for unit version 2.0
Using new functions
---
---
---
---
---
OK
Not using new functions
---
---
---
---
OK*1
OK
CJ2H-CPU6@ Unit version 1.1
CJ2H-CPU6@-EIP Unit version 1.2
CJ2H-CPU6@ Unit version 1.2
CJ2H-CPU6@-EIP Unit version 1.3
CJ2H-CPU6@ Unit version 1.3
CJ2M
CX-Programmer
Functions
Functions added for unit version 1.1
*1 It is not necessary to upgrade the version of the CX-Programmer if functionality that was enhanced for the upgrade of the CPU Unit will not be used. *2 CX-Programmer version 8.2 or higher is required to use the functions added for unit version 1.1. The highspeed interrupt function and changing the minimum cycle time setting in MONITOR mode, however, are also supported by CX-Programmer version 8.02. *3 A Programming Console cannot be used with a CJ2 CPU Unit.
z Pull-down List for PLC Models Unit versions are not differentiated in the pull-down list for PLC models in the Change PLC Dialog Box of the CX-Programmer. Select as shown in the following table regardless of the unit version. PLC model in Change PLC Dialog Box in CX-Programmer version 9.0 or higher
Series
CPU Unit
Model number
CJ Series
CJ2H CPU Unit
CJ2H-CPU6@-EIP CJ2H-CPU6@
CJ2H
CJ2M CPU Unit
CJ2M-CPU3@ CJ2M-CPU1@
CJ2M
CJ2 CPU Unit Hardware User’s Manual
33
Page 40
Troubleshooting Problems with Unit Versions on the CX-Programmer Problem
Cause
Solution
An attempt was made to download a program containing instructions supported only by later unit versions or a CPU Unit to a previous unit version.
Check the program or change to a CPU Unit with a later unit version.
An attempt was to download a PLC Setup containing settings supported only by later unit versions or a CPU Unit to a previous unit version.
Check the settings in the PLC Setup or change to a CPU Unit with a later unit version.
An attempt was made to upload a program containing instructions supported only by higher versions of CX-Programmer to a lower version.
New instructions cannot be uploaded to lower versions of CX-Programmer. Use a higher version of CX-Programmer.
After the above message is displayed, a compiling error will be displayed on the Compile Tab Page in the Output Window.
“????” is displayed in a program transferred from the PLC to the CX-Programmer.
34
CJ2 CPU Unit Hardware User’s Manual
Page 41
Related Manuals Manuals related to a PLC built using a CJ-series CJ2 CPU Unit are listed in the following table. Use these manuals for reference. Manual
Cat. No.
CJ-series CJ2 CPU Unit Hardware User’s Manual (this manual)
W472
Model CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU@@
Application Hardware specifications for CJ2 CPU Units
Description Describes the following for CJ2 CPU Units: • Overview and features • Basic system configuration • Part nomenclature and functions • Mounting and setting procedure • Remedies for errors • Also refer to the Software User’s Manual (W473).
CJ-series CJ2 CPU Unit Software User’s Manual
W473
CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU@@
Software specifications for CJ2 CPU Units
Describes the following for CJ2 CPU Units: • CPU Unit operation • Internal memory • Programming • Settings • Functions built into the CPU Unit Also refer to the Hardware User’s Manual (W472)
CS/CJ-series EtherNet/IP Units Operation Manual
W465
CJ-series CJ2M CPU Unit Pulse I/O Module User's Manual
W486
CJ2H-CPU6@-EIP CJ2M-CPU3@ CS1W-EIP21 CJ1W-EIP21
Using the built-in EtherNet/IP port of the CJ2 CPU Unit
Describes the built-in EtherNet/IP port and EtherNet/IP Units.
CJ2M-CPU@@
Information on using builtin I/O on CJ2M CPU Units
Provides the following information on the CJ2M CPU Units:
+ CJ2M-MD21@
Describes basic settings, tag data links, FINS communications, and other functions.
• Specifications and wiring methods • I/O functions • Quick-response inputs • Interrupt functions • High-speed counters • Pulse outputs • PWM outputs When programming, use this manual together with the Instructions Reference Manual (Cat. No. W474).
CS/CJ/NSJ-series Instructions Reference Manual
W474
CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU@@ CS1G/H-CPU@@H CS1G/H-CPU@@-V1 CJ1G/H-CPU@@H CJ1G-CPU@@ CJ1M-CPU@@ NSJ@-@@@@(B)-G5D NSJ@-@@@@(B)-M3D
CJ2 CPU Unit Hardware User’s Manual
Information on instructions
Describes each programming instruction in detail. Also refer to the Software User’s Manual (W473) when you do programming.
35
Page 42
Manual
Cat. No.
Model
Application
Description
CS/CJ/CP/NSJseries Communications Command Reference Manual
W342
CJ2H-CPU6@-EIP CJ2H-CPU6@ CS1G/H-CPU@@H CS1G/H-CPU@@-V1 CS1D-CPU@@H CS1D-CPU@@S CS1W-SCU@@-V1 CS1W-SCB@@-V1 CJ1H-CPU@@H-R CJ1G/H-CPU@@H CJ1G-CPU@@P CJ1M-CPU@@ CJ1G-CPU@@ CJ1W-SCU@@-V1 CP1H-X@@@@-@ CP1H-XA@@@@-@ CP1H-Y@@@@-@ CP1L-M/L@@@-@@ CP1E-E/N@@D@-@ NSJ@-@@@@(B)-G5D NSJ@-@@@@(B)-M3D
Information on communications for CS/CJ/CPseries CPU Units and NSJseries Controllers
Describes C-mode commands and FINS commands Refer to this manual for a detailed description of commands for communications with the CPU Unit using C mode commands or FINS commands. Note This manual describes the communications commands that are addressed to CPU Units. The communications path that is used is not relevant and can include any of the following: serial ports on CPU Units, communications ports on Serial Communications Units/Boards, and Communications Units. For communications commands addressed to Special I/O Units or CPU Bus Units, refer to the operation manual for the related Unit.
CX-One Setup Manual
W463
CXONE-AL@@CV@/AL@@D-V@
Installing software from the CX-One
Provides an overview of the CX-One FA Integrated Tool Package and describes the installation procedure.
CX-Programmer Operation Manual
W446
WS02-CX@@-V@
Support Software for Windows computers
Describes operating procedures for the CX-Programmer.
CX-Programmer Operation Manual Functions Blocks/Structured Text
W447 CX-Programmer operating procedure
Also refer to the Software User’s Manual (W473) and CS/CJ/NSJ-series Instructions Reference Manual (W474) when you do programming.
CX-Programmer Operation Manual SFC Programming
W469
CS/CJ/CP/NSJseries CX-Simulator Operation Manual
W366
CS/CJ/CP/NSJseries CX-Integrator Network Configuration Software Operation Manual
W464
36
WS02-SIMC1-E
Operating procedures for CX-Simulator Simulation Support Software for Windows computers
Describes the operating procedures for the CXSimulator.
Network setup and monitoring
Describes the operating procedures for the CXIntegrator.
When you do simulation, also refer to the CXProgrammer Operation Manual (W446), SoftUsing simulation in the CX- ware User’s Manual (W473), and CS/CJ/NSJseries Instructions Reference Manual (W474). Programmer with CX-Programmer version 6.1 or higher
CXONE-AL@@C-V@/ CXONE-AL@@D-V@
CJ2 CPU Unit Hardware User’s Manual