5 The following dialog box will be displayed if the installation is completed normally. Click the Finish Button.
Installing a Specified USB Driver If the USB driver cannot be installed automatically, use the following procedure to install it.
z Windows Vista/Windows 7 personal computer using a USB cable.
2 The following dialog box will be displayed. Select Locate and install driver software (Recommended).
A-5 Installing the USB Driver
1 Turn ON the power supply to the PLC and connect the peripheral USB port on the PLC to the
App A-4-3 Applicable Connectors and Recommended Cables
CJ2 CPU Unit Hardware User’s Manual
A-141
Page 404
Appendices
3 The following dialog box will be displayed. Select I don't have the disc. Show me other options.
4 The following dialog box will be displayed. Click the Browse Button, specify the following location, and then click the Next Button. C:\Program Files\OMRON\CX-Server\USB\Win2000_XP\Inf
A-142
CJ2 CPU Unit Hardware User’s Manual
Page 405
Appendices
5 Ignore the following dialog box if it is displayed and select Install this driver software anyway.
6 The following dialog box will be displayed when the driver software has been installed successfully.
1 The following window will be displayed. Select the Install from a list of specific location Option
App and then click the Next Button.
A-5 Installing the USB Driver z Windows XP
A-4-3 Applicable Connectors and Recommended Cables
CJ2 CPU Unit Hardware User’s Manual
A-143
Page 406
Appendices
2 The following window will be displayed. Click the Browse Button for the Include this location in the search Field, specify C:\Program Files\OMRON\CX-Server\USB\win2000_XP\Inf, and then click the Next Button. The driver will be installed. (“C:\” indicates the installation drive and may be different on your computer.)
3 Ignore the following window if it is displayed and click the Continue Anyway Button.
4 The following window will be displayed if the installation is completed normally. Click the Finish Button.
A-144
CJ2 CPU Unit Hardware User’s Manual
Page 407
Appendices z Windows 2000
1 Turn ON the power supply to the CJ2 PLC, and connect a USB cable between the USB port on the computer and the peripheral (USB) port on the CJ2 CPU Unit. After the cable has been connected, the computer will automatically recognize the device and the following message will be displayed.
2 The following message will be displayed. Click the Next Button.
Select the Search for a suitable driver for the device (recommended) Option and then click the Next Button.
A-5 Installing the USB Driver
3 The following window will be displayed.
App A-4-3 Applicable Connectors and Recommended Cables
CJ2 CPU Unit Hardware User’s Manual
A-145
Page 408
Appendices
4 The following window will be displayed. From the list in the window, select the Specify location Check Box and then click the Next Button.
5 Click the Browse Button, specify C:\Program Files\OMRON\CX-Server\USB\win2000_XP\Inf, and then click the Next Button. (“C:\” indicates the installation drive and may be different on your computer.)
6 A search will be made for the driver and the following window will be displayed. Click the Next Button. The driver will be installed.
7 After the driver has been successfully installed, the following window will be displayed. Click the Finish Button.
A-146
CJ2 CPU Unit Hardware User’s Manual
Page 409
Appendices
Checking after Installation
1 Display the Device Manager at the computer. 2 Click USB (Universal Serial Bus) Controllers, and confirm that OMRON SYSMAC PLC Device is displayed.
If the USB driver installation fails for some reason or is cancelled in progress, the USB driver must be reinstalled.
z Checking USB Driver Status
1 Display the Device Manager on the computer. driver software failed.
App
2 If the OMRON-PLC is displayed under Universal Serial Bus controllers, installation of the USB
A-5 Installing the USB Driver
Re-installing the USB Driver
A-4-3 Applicable Connectors and Recommended Cables
CJ2 CPU Unit Hardware User’s Manual
A-147
Page 410
Appendices z Reinstalling the USB Driver
1 Right-click OMRON-PLC under Universal Serial Bus controllers and select Properties. The properties will be displayed.
2 Click the Reinstall Driver Button. The Hardware Update Wizard Dialog Box will be displayed. Install the driver software using the procedure described in Installing the USB Driver.
A-148
CJ2 CPU Unit Hardware User’s Manual
Page 411
Appendices
Load Short-circuit Protection and Line Disconnection Detection for Basic I/O Units
A-6-1
Load Short-circuit Protection and Line Disconnection Detection for CJ1W-OD202
This section describes the load short-circuit protection of the CJ1W-OD202 Output Units. As shown below, normally when the output bit turns ON (OUT), the transistor will turn ON and then output current (Iout) will flow. Normal Operation OUT: OUTPUT instruction IOUT: Output current ERR: Alarm output, ERR indicator Ilim: Short-circuit detection current IOL: Disconnection detection current Tj: Junction temperature of transistor Tstd: Thermal shutdown temperature Reset temperature Tr:
ON
OUT
OFF
ON
IOUT
OFF ON
ERR
OFF
If the output (Iout) is overloaded or short-circuited exceeding the detection current (Ilim), the output current (Iout) will be limited as shown in figure below. When the junction temperature (Tj) of the output transistor reaches the thermal shutdown temperature (Tstd), the output will turn OFF to protect the transistor from being damaged, and the alarm output bit will turn ON to light the ERR indicator. When the junction temperature (Tj) of the transistor drops down to the reset temperature (Tr), the ERR indicator will be automatically reset and the output current will start flowing. Operation for Overload or Short Circuit ON
OUT
OFF
ON
App
IOUT
Tj =Tstd Tj =Tr Ilim
OFF
ON
ERR
Operation for Disconnected Line with Output Current below the Line Disconnection Detection Current ON OFF
ON
IOUT
IOL
OFF
ON
ERR
OFF
A
B
C
A: Load not connected or load line broken. B: Current to load at or below line disconnection detection current. C: Rise of current to load too slow and error detected before the disconnection detection current was reached. CJ2 CPU Unit Hardware User’s Manual
A-149
A-6-1 Load Short-circuit Protection and Line Disconnection Detection for CJ1W-OD202
OFF
If the line is disconnected and the output current (Iout) drops below the line disconnection detection current (IOL), the ERR indicator will light as shown in the following figure.
OUT
A-6 Load Short-circuit Protection and Line Disconnection Detection for Basic I/O Units
A-6
Page 412
Appendices
When load L is connected, the ERR indicator may light and the Alarm Output Bit may turn ON for approximately 100 ms. The programming example given later in this section can be used so that an error is not detected in this case.
z Operating Restrictions Although the CJ1W-OD202 is provided with short-circuit protection, these are for protecting internal circuits against momentary short-circuiting in the load. As shown in Figure 2, the short-circuit protection is automatically released when the Tj equals to Tr. Therefore, unless the cause of short-circuit is removed, ON/OFF operations will be repeated in the output. Leaving short-circuits for any length of time will cause internal temperature rise, deterioration of elements, discoloration of the case or PCBs, etc. Therefore, observe the following restrictions.
z Restrictions If a short-circuit occurs in an external load, immediately turn OFF the corresponding output and remove the cause. The CJ1W-OD202 turns ON an alarm output bit that corresponds to the external load output number. There is an alarm output bit for every common. When an alarm output bit turns ON, use a self-holding bit for the alarm in the user program and turn OFF the corresponding output. The alarm output bit is allocated in the Basic I/O Unit Information Area (A050 to A069) for every Unit mounting slot. The following table shows the correspondence between output bits and bits in the Basic I/O Unit Information Area. Output bit CJ1W-OD202
0 to 1
2 to 3
4 to 5
6 to 7
Mounted in even slot
0
1
2
3
Mounted in odd slot
8
9
10
11
For example, when the CJ1W-OD202 is mounted in slot 0 on Rack 0, A50.00 will turn ON if the output 0 is short-circuited. When the CJ1W-OD202 is mounted in slot 1 of Rack 0, A50.11 will turn ON if the output 7 is short-circuited.
z Programming Example In this example, CJ1W-OD202 is mounted in slot 0 of the Rack 0. This example shows how to turn OFF output bits CIO 0.00 immediately if the alarm output bit A50.00 turns ON and how to keep the output bits OFF until the cause is removed and the bit is reset using work bit W0.01. Change to CIO 0.00, CIO 1.00, 0 (under TIM and at bottom right of diagram), A50.00, and W0.01. To prevent the alarm output bit from turning ON momentarily when the load turns ON, the alarm output is not turned ON for 200 ms after the input (CIO 1.00) turns ON. A50.00
1.00
TIM 0000 #0002
TIM0
W0.01 W0.00
W0.00
1.00
W0.00 0.00
A-150
CJ2 CPU Unit Hardware User’s Manual