Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of CQM1

Spec sheet · Omron

CQM1

Spec sheet7 pagesPDF 423 KB

Brochure and spec sheet for the OMRON CQM1 PLC: CPUs such as the CQM1-CPU21, power supplies, I/O modules and ordering data.

Download the PDF423 KB

Names · 8 models

The models it names

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

OMRON's 1998 brochure for the CQM1 programmable controller for small and medium machine control. It describes the seven CPUs, power supply units, optional EEPROM and EPROM memory cassettes, standard DC and AC input modules (such as the CQM1-ID211, ID212 and ID213), relay, transistor and triac output modules (such as the CQM1-OD211, OD212 and OD213) and special I/O modules, with dimensions, power supply and CPU performance specifications and ordering information.

Its parts

  1. Controlling Quality
  2. Power Supply Units
  3. CPU Units
  4. Memory Cassettes
  5. Input Modules
  6. Output Modules
  7. Special I/O Modules
  8. Dimensions
  9. General Specifications
  10. Performance Specifications
  11. Ordering Information
  12. Omron Control Solutions

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

An Omron sales brochure (SB CQM1-1, 1998) for the CQM1 family of small modular PLCs. It lists the power supply units, the CPU units CQM1-CPU11 through CQM1-CPU45, memory cassettes, standard input and output modules and special I/O modules, with specifications and ordering numbers. Its cover page is a scanned picture with no usable text.

System
Omron CQM1 modular PLC for small machines; CPU, power supply and I/O modules connect and lock together with no backplane p. 2
Maximum I/O
CPU11 and CPU21: 128 points, 7 modules; CPU41 to CPU45: 256 points, 11 modules p. 5
Standard I/O range
AC or DC input modules and triac, transistor or relay output modules, 8 to 32 points each p. 2
Power supply units
CQM1-PA203 and CQM1-PA206 (100 to 240 VAC, the PA206 with a 0.5 A 24 VDC service supply) and CQM1-PD026 (24 VDC) p. 3, 5
Operating temperature
0° to 55° C for the power supply units p. 5
Programming tools
CQM1-PRO01-E or C200H-PRO27-E console with a 1.5 m cable; SYSWIN-HL-V3.2A Windows software p. 5
PC cables
CQM1-C1F02 (peripheral port); C200HS-CN220-EU (RS232, 9 pin) and C200HS-CN229-EU (25 pin) p. 5
CPU built-in inputs
16 DC inputs on every CPU; four can be interrupt inputs and one a high-speed counter input p. 3
CPU memory
CPU11 and CPU21: 3.2K words program, 1K words DM; CPU41 to CPU45: 7.2K words program, 6K words DM p. 5
Instruction set
117 instructions (CPU11, CPU21) or 137 (CPU41 to CPU45); basic instructions 0.5 to 1.5 µs; ladder diagram p. 5
Interrupts and counter
4 hardware interrupts, 3 scheduled interrupts; 2-phase high-speed counter at 2.5 kHz p. 5
Memory cassettes
EEPROM 4K or 8K words, or EPROM IC socket, with or without clock: CQM1-ME04K, ME04R, ME08K, ME08R, MP08K, MP08R p. 5
DC input modules
CQM1-ID211 8 points 12 to 24 VDC; CQM1-ID212 16 points 24 VDC; CQM1-ID213 32 points 24 VDC p. 5
Transistor output modules
CQM1-OD211 8 points 2 A at 24 VDC; CQM1-OD212 16 points 50 to 300 mA; CQM1-OD213 32 points 100 mA at 24 VDC p. 5

What this sheet walks you through

  • Choosing a power supply unit p. 3
  • Comparing the CPU units p. 3, 5
  • Choosing a memory cassette with or without a clock p. 3
  • Choosing standard input and output modules p. 4
  • Special I/O modules: analog, temperature, DeviceNet, CompoBus/S, B7A, sensors p. 4
  • Unit dimensions in inches and millimeters p. 5
  • Ordering numbers for the whole system p. 5

Good to know

  • Data cannot be written to an EPROM cassette from the CPU unit. p. 3
  • The analog input and output modules need a CQM1-IPS01 or CQM1-IPS02 power supply module. p. 4
  • Two CQM1-DA021 analog output modules cannot be used with one CQM1-IPS02. p. 5
  • The end plate for the right side of the CQM1 comes with the CPU unit. p. 3

Questions this sheet answers

How many I/O points does the CQM1-CPU21 support?

The CQM1-CPU11 and CPU21 handle up to 128 I/O points and 7 I/O modules. p. 5

Does the CQM1 need a backplane?

No. The modules connect and lock to each other without a backplane. p. 2

How many inputs does the CQM1-ID213 have?

32 points at 24 VDC. p. 5

What cable connects a CQM1 to a computer?

The CQM1-C1F02 cable for the peripheral port, or C200HS-CN220-EU (9 pin) or C200HS-CN229-EU (25 pin) for RS232. p. 5

Which memory cassettes fit the CQM1?

EEPROM cassettes of 4K or 8K words or an EPROM socket cassette, each with or without a real-time clock, such as the CQM1-ME04K and CQM1-ME08R. p. 5

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. CQM11
    1. Controlling Quality2
    2. Power Supply Units3
    3. CPU Units3
    4. Memory Cassettes3
    5. Input Modules4
    6. Output Modules4
    7. Special I/O Modules4
    8. Dimensions5
    9. General Specifications5
    10. Performance Specifications5
    11. Ordering Information5
    12. Omron Control Solutions6
  2. Contacting Omron6

From the PDF’s own bookmarks.

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 71-7

The file

Revision and size

RevisionSB CQM1-1 9/98/10M
PublisherOMRON Electronics, Inc.
Pages7
PDF423 KB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 4 of 7

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 7
Page 2
Page 2of 7
Page 3
Page 3of 7
Page 4
Page 4of 7