Manual · Omron
SYSMAC CQM1/CPM1/CPM1A/SRM1 Programmable Controllers Programming Manual
Manual520 pagesPDF 2.1 MB
Programming manual for the OMRON SYSMAC CQM1, CPM1, CPM1A and SRM1 programmable controllers: setup, memory, ladder instructions.
Names · 1 model
The models it names
Filed with · 8 models
Also filed with these models on the old site
Omron CQM1-PD026Switching power supply from$145.001 in stock
Omron CQM1-CPU41-V1Programmable controller Call for availability Summary
What is in it
OMRON's programming manual for the SYSMAC CQM1, CPM1, CPM1A and SRM1 Programmable Controllers. It covers the PC Setup and related functions such as interrupts, pulse outputs and communications, the memory areas and Memory Cassettes, writing ladder-diagram programs, the full instruction set, host link commands, cycle and I/O response times, and troubleshooting. Appendices list the instructions, memory areas, FAL numbers and coding sheets. Hardware details are in the separate operation manuals.
Its parts
- Precautions
- PC Setup and Other Features
- Special Features
- Memory Areas
- Ladder-diagram Programming
- Instruction Set
- Host Link Commands
- PC Operations and Processing Time
- Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
Programming manual for the Omron SYSMAC CQM1, CPM1, CPM1A and SRM1 programmable controllers, covering the PC Setup, memory areas, ladder-diagram instructions, host link commands, processing time and troubleshooting. It is a software manual: for hardware details it refers the reader to the separate operation manuals, so it does not describe the CQM1-ID211 or other I/O Units themselves.
- Document
- Programming manual for CQM1, CPM1, CPM1A and SRM1 PCs: memory structure, ladder instructions, host link commands and error diagnosis p. 4
- CQM1 power supply range
- CQM1-PA203/PA206: 85 to 264 VAC; CQM1-PD026: 20 to 28 VDC p. 452
- CQM1 I/O bits
- Input bits IR 00000 to IR 01515; output bits IR 10000 to IR 11515 p. 155
- Error code location
- Error code stored in SR 25300 to SR 25307; recent errors kept in the error log area p. 441
- Low battery error
- CQM1 BATT LOW (F7): backup battery missing or low, SR 25308 ON; DM 6655 sets whether it is detected p. 445
- Watchdog error
- SCAN TIME OVER (F8): watchdog timer over 100 ms, SR 25309 ON p. 445
- CQM1 fatal error codes
- MEMORY ERR (F1), NO END INST (F0), I/O BUS ERR (C0), I/O UNIT OVER (E1), SYS FAIL FALS 01 to 99 and 9F p. 446
- I/O capacity by CPU
- CQM1-CPU11/21-E: up to 8 words (128 bits), up to 7 Units; CQM1-CPU4□-EV1: up to 16 words (256 bits), up to 11 Units p. 154
- Program memory by CPU
- CQM1-CPU11/21-E: 3,200 words; CQM1-CPU4□-EV1: 7,200 words p. 155
- DM area
- DM 0000 to DM 1023 (1,024 words); DM 1024 to DM 6143 only on CQM1-CPU4□-EV1; PC Setup in DM 6600 to DM 6655 p. 155, 446
- Other CQM1 areas
- HR 00 to HR 99, AR 00 to AR 27, LR 00 to LR 63, timers and counters TC 000 to TC 511 p. 154
- Communications ports
- RS-232C port (DM 6645) and peripheral port (DM 6650): host link, RS-232C, 1:1 link slave or master, 1:1 NT Link p. 109
- Host link node number
- 00 to 31, default 00 (DM 6648 for the RS-232C port, DM 6653 for the peripheral port) p. 109
- Write protect
- CQM1: pin 1 of the CPU Unit's DIP switch; set it OFF to write to memory p. 441
What this manual walks you through
- Clearing Programming Console operation error messages p. 441
- Fixing syntax errors found by the three program check levels p. 442, 443
- Defining your own errors with MSG, FAL and FALS p. 443, 444
- Responding to non-fatal operating errors p. 444, 445
- Responding to fatal operating errors p. 446
- Solving Memory Cassette transfer errors p. 444
- Setting the communications mode and 1:1 links p. 109
- The CQM1 memory area map p. 154, 155
- Checking the power supply when the Power indicator is not lit p. 452
Good to know
- A fatal error stops program execution and turns OFF all outputs from the PC. p. 446
- Installing or removing a Memory Cassette with the power on causes a MEMORY ERR. p. 446
- Do not use the same output bit in more than one OUT or OUT NOT instruction. p. 155
- A 1:1 NT Link cannot be used with the CQM1-CPU21-E. p. 109
- Hardware information and Programming Console procedures are in the separate operation manuals. p. 4
Questions this manual answers
What input voltage does the CQM1-PA203 power supply accept?
The manual gives 85 to 264 VAC for the CQM1-PA203/PA206 and 20 to 28 VDC for the CQM1-PD026. p. 452
What does I/O BUS ERR mean on a CQM1?
A data transfer error between the CPU Unit and an I/O Unit. Find the location with AR 2408 to AR 2415, turn the power off, check for loose I/O Units or end covers, and power up again. p. 446
What does BATT LOW mean on a CQM1?
The backup battery is missing or its voltage has dropped (SR 25308 ON); check the battery and replace it if necessary. p. 445
How do I clear the REPL ROM message on a CQM1?
It means a write to write-protected memory; set pin 1 of the CPU Unit's DIP switch to OFF. p. 441
How much program memory does the CQM1-CPU21-E have?
3,200 words for the CQM1-CPU11/21-E, against 7,200 words for the CQM1-CPU4□-EV1. p. 155
Contents
Chapters and sections
Each line opens the PDF at its page.
- Front1
- CQM1/CPM1/CPM1A/SRM1 Programmable Controllers2
- PRECAUTIONS8
- SECTION 1 PC Setup and Other Features21
- 1-1 PC Setup23
- 1-2 Basic PC Operation and I/O Processes36
- 1-3 Pulse Output Function (CQM1 Only)42
- 1-4 Pulse Output Function (CPM1A Only)55
- 1-5 CQM1 Interrupt Functions58
- 1-6 CPM1/CPM1A Interrupt Functions87
- 1-7 SRM1 Interrupt Functions103
- 1-8 CompoBus/S Distributed I/O Functions (SRM1 Only)106
- 1-9 Communications Functions107
- 1-10 Calculating with Signed Binary Data131
- SECTION 2 Special Features135
- SECTION 3 Memory Areas153
- SECTION 4 Ladder-diagram Programming170
59 more lines, from page 199 on
- SECTION 5 Instruction Set199
- 5-1 Notation202
- 5-2 Instruction Format202
- 5-3 Data Areas, Definer Values, and Flags202
- 5-4 Differentiated Instructions204
- 5-5 Coding Right-hand Instructions204
- 5-6 Instruction Tables208
- 5-7 Ladder Diagram Instructions214
- 5-8 Bit Control Instructions215
- 5-9 NO OPERATION – NOP(00)219
- 5-10 END – END(01)219
- 5-11 INTERLOCK and INTERLOCK CLEAR – IL(02) and ILC(03)219
- 5-12 JUMP and JUMP END – JMP(04) and JME(05)221
- 5-13 User Error Instructions: FAILURE ALARM AND RESET – FAL(06) and SEVERE FAILURE ALARM – FALS(07)223
- 5-14 Step Instructions: STEP DEFINE and STEP START–STEP(08)/SNXT(09)224
- 5-15 Timer and Counter Instructions226
- 5-16 Shift Instructions242
- 5-17 Data Movement Instructions250
- 5-18 Comparison Instructions260
- 5-18-9 DOUBLE AREA RANGE COMPARE – ZCPL(––)270
- 5-19 Conversion Instructions270
- 5-20 BCD Calculation Instructions296
- 5-21 Binary Calculation Instructions307
- 5-22 Special Math Instructions318
- 5-23 Logic Instructions326
- 5-24 Increment/Decrement Instructions329
- 5-25 Subroutine Instructions331
- 5-26 Special Instructions333
- 5-27 Communications Instructions358
- 5-28 Advanced I/O Instructions363
- SECTION 6 Host Link Commands367
- SECTION 7 PC Operations and Processing Time398
- SECTION 8 Troubleshooting440
- Appendix A Programming Instructions458
- Appendix B Error and Arithmetic Flag Operation464
- Appendix C Memory Areas468
- Appendix D Using the Clock Function486
- Appendix E I/O Assignment Sheet487
- Appendix F Program Coding Sheet488
- Appendix G List of FAL Numbers491
- Appendix H Extended ASCII493
- Appendix I CPM1/CPM1A and CQM1 Memory Area Comparison494
- Glossary495
- Index511
- Revision History518
The whole text · 60 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- TABLE OF CONTENTS5-7
- PRECAUTIONS8-20
- SECTION 1 PC Setup and Other Features, pages 21 to 3021-30
- SECTION 1 PC Setup and Other Features, pages 31 to 4031-40
- SECTION 1 PC Setup and Other Features, pages 41 to 5041-50
- SECTION 1 PC Setup and Other Features, pages 51 to 6051-60
- SECTION 1 PC Setup and Other Features, pages 61 to 7061-70
- SECTION 1 PC Setup and Other Features, pages 71 to 8071-80
- SECTION 1 PC Setup and Other Features, pages 81 to 9081-90
- SECTION 1 PC Setup and Other Features, pages 91 to 10091-100
- SECTION 1 PC Setup and Other Features, pages 101 to 110101-110
- SECTION 1 PC Setup and Other Features, pages 111 to 120111-120
- SECTION 1 PC Setup and Other Features, pages 121 to 130121-130
- SECTION 1 PC Setup and Other Features, pages 131 to 134131-134
- SECTION 2 Special Features, pages 135 to 143135-143
- SECTION 2 Special Features, pages 144 to 152144-152
- SECTION 3 Memory Areas, pages 153 to 161153-161
- SECTION 3 Memory Areas, pages 162 to 169162-169
- SECTION 4 Ladder-diagram Programming, pages 170 to 179170-179
- SECTION 4 Ladder-diagram Programming, pages 180 to 189180-189
- SECTION 4 Ladder-diagram Programming, pages 190 to 198190-198
- SECTION 5 Instruction Set, pages 199 to 208199-208
- SECTION 5 Instruction Set, pages 209 to 218209-218
- SECTION 5 Instruction Set, pages 219 to 228219-228
- SECTION 5 Instruction Set, pages 229 to 238229-238
- SECTION 5 Instruction Set, pages 239 to 248239-248
- SECTION 5 Instruction Set, pages 249 to 258249-258
- SECTION 5 Instruction Set, pages 259 to 268259-268
- SECTION 5 Instruction Set, pages 269 to 278269-278
- SECTION 5 Instruction Set, pages 279 to 288279-288
- SECTION 5 Instruction Set, pages 289 to 298289-298
- SECTION 5 Instruction Set, pages 299 to 308299-308
- SECTION 5 Instruction Set, pages 309 to 318309-318
- SECTION 5 Instruction Set, pages 319 to 328319-328
- SECTION 5 Instruction Set, pages 329 to 338329-338
- SECTION 5 Instruction Set, pages 339 to 348339-348
- SECTION 5 Instruction Set, pages 349 to 358349-358
- SECTION 5 Instruction Set, pages 359 to 366359-366
- SECTION 6 Host Link Commands, pages 367 to 374367-374
- SECTION 6 Host Link Commands, pages 375 to 382375-382
- SECTION 6 Host Link Commands, pages 383 to 390383-390
- SECTION 6 Host Link Commands, pages 391 to 397391-397
- SECTION 7 PC Operations and Processing Time, pages 398 to 406398-406
- SECTION 7 PC Operations and Processing Time, pages 407 to 415407-415
- SECTION 7 PC Operations and Processing Time, pages 416 to 424416-424
- SECTION 7 PC Operations and Processing Time, pages 425 to 433425-433
- SECTION 7 PC Operations and Processing Time, pages 434 to 439434-439
- SECTION 8 Troubleshooting, pages 440 to 448440-448
- SECTION 8 Troubleshooting, pages 449 to 457449-457
- Appendix A Programming Instructions458-463
- Appendix B Error and Arithmetic Flag Operation464-467
- Appendix C Memory Areas, pages 468 to 476468-476
- Appendix C Memory Areas, pages 477 to 485477-485
- Pages 486 to 490486-490
- Pages 491 to 493491-493
- Pages 494 to 502494-502
- Pages 503 to 510503-510
- Index511-517
- Revision History518-520
The file





