Page 53

1 Overview

With the CJ2M CPU Units, up to two Pulse I/O Modules can be mounted. This enables input functions, such as normal inputs, interrupt inputs, high-speed counter inputs, and quick-response inputs, and output functions, such as normal outputs, pulse outputs, and variable duty factor pulse outputs. This provides support for many different types of applications. Pulse I/O Modules

1-1 Overview of CJ2 CPU Units

Use Pulse I/O and Interrupt Inputs (CJ2M CPU Units Only)

1 1-1-2 CJ2 CPU Unit Features

• Normal outputs: 12 (6 per Pulse I/O Module) • Normal inputs: 20 (10 per Pulse I/O Module) • Pulse outputs: 4 (2 per Pulse I/O Module) • Interrupt inputs: 8 (4 per Pulse I/O Module) • High-speed counter inputs: 4 (2 per Pulse I/O Module) • Variable duty factor pulse outputs: 4 (2 per Pulse I/O Module) • Quick-response inputs: 8 (4 per Pulse I/O Module)

CJ2 CPU Unit Hardware User’s Manual

1-11

Page 54

1 Overview

1-2

Basic Operating Procedure In general, use the following procedure. 1. Setting Devices and Hardware Mount the Power Supply Unit, the CPU Unit, the other Units, and the End Covers. Set the DIP switch and rotary switches as required.

Refer to Section 3 Nomenclature and Functions and Section 5 Installation in the CJ2 CPU Unit Hardware User’s Manual (Cat. No. W472).

2. Wiring Wire the power supply, I/O, and communications. Refer to the following manuals.

Refer to Section 5 Installation in the CJ2 CPU Unit Hardware User’s Manual (Cat. No. W472). Refer to Section 11 Programming Devices and Communications in the CJ2 CPU Unit Software User’s Manual (Cat. No. W473). Refer to Section 3 I/O Specifications and Wiring for Pulse I/O Module in the CJ2M CPU Unit Pulse I/O Module User's Manual (Cat. No. W486).

3. Connecting Online to the PLC Connect the personal computer online to the PLC.

Refer to Section 4 Support Software in the CJ2 CPU Unit Hardware User’s Manual (Cat. No. W472)

4. I/O Allocations Using the CX-Programmer, allocate I/O memory in the CPU Unit to the mounted Units.

Refer to Section 8 I/O Allocations and Unit Settings in the CJ2 CPU Unit Software User’s Manual (Cat. No. W473) Refer to Section 2 I/O Application Procedures and Function Allocations in the CJ2M CPU Unit Pulse I/O Module User's Manual (Cat. No. W486).

5. Software Setup Make the PLC software settings.

• CPU Unit initialization: Refer to Section 4 CPU Unit Initialization in the CJ2 CPU Unit Software User’s Manual (Cat. No. W473). • DM Area Settings for Special I/O Units and CPU Bus Units: Refer to Section 8 I/O Allocations and Unit Settings in the CJ2 CPU Unit Software User’s Manual (Cat. No. W473). • PLC Setup: Refer to Section 9 PLC Setup in the CJ2 CPU Unit Software User’s Manual (Cat. No. W473).

6. Creating the Program Create the program using the CX-Programmer. Refer to Section 5 Understanding Programming in the CJ2 CPU Unit Software User’s Manual (Cat. No. W473).

7. Checking Operation Check the I/O wiring and the AR Area settings, and perform trial operation. The CX-Programmer can be used for monitoring and debugging.

Refer to 10-7 Debugging in the CJ2 CPU Unit Software User’s Manual (Cat. No. W473).

8. Basic Program Operation Set the operating mode to RUN mode to start operation.

1-12

CJ2 CPU Unit Hardware User’s Manual

Page 55

1 Overview

Specifications

1-3-1

General Specifications

1-3 Specifications

1-3

CJ2H-

CJ2M-

Item CPU64(-EIP)

CPU65(-EIP)

Mounted in a panel

Grounding

Less than 100 Ω

CPU Unit Dimensions

Weight

Current Consumption

Use Environment

CPU67(-EIP)

CJ2H-CPU6@-EIP:

90 mm × 65 mm × 80 mm (H × D × W)

CJ2H-CPU6@:

90 mm × 65 mm × 49 mm (H × D × W)

CJ2H-CPU6@-EIP:

280 g or less

CJ2H-CPU6@:

190 g or less

CJ2H-CPU6@-EIP:

5 VDC, 0.82 A

CJ2H-CPU6@:

5 VDC, 0.42 A

Ambient Operating Temperature

0 to 55°C

Ambient Operating Humidity

10% to 90% (with no condensation)

Atmosphere

Must be free from corrosive gases.

Ambient Storage Temperature

−20 to 70°C (excluding battery)

Altitude

2,000 m or less

Pollution Degree

2 or less: Conforms to JIS B3502 and IEC 61131-2.

Noise Immunity

2 kV on power supply line (Conforms to IEC 61000-4-4.)

Overvoltage Category

Category II: Conforms to JIS B3502 and IEC 61131-2.

EMC Immunity Level

Zone B

Vibration Resistance

CPU68(-EIP)

CPU1@

CPU3@

90 mm × 75 mm × 31 mm (H × D × W)

90 mm × 75 mm × 62 mm (H × D × W)

130 g or less

190 g or less*

5 VDC, 0.5 A

5 VDC, 0.7 A

Conforms to IEC60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)

Shock Resistance

Conforms to IEC60068-2-27. 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)

Battery

Life

5 years at 25°C

Model

CJ1W-BAT01

Applicable Standards

Conforms to cULus, NK, LR, and EC Directives.

* Without a Serial Option Board

CJ2 CPU Unit Hardware User’s Manual

1-13

1 1-3-1 General Specifications

Enclosure

CPU66(-EIP)

Page 56

1 Overview

1-3-2

Performance Specifications CJ2HItems

CJ2M-

CPU64 (-EIP)

CPU65 (-EIP)

CPU66 (-EIP)

CPU67 (-EIP)

CPU68 (-EIP)

User Memory

50K steps

100K steps

150K steps

250K steps

400K steps

I/O Bits

2,560 bits

Processing Speed

CJ2H-CPU@@-EIP:200 µs

CPU 11/31 5K steps

CPU 12/32 10K steps

20K steps

CPU 14/34 30K steps

CPU 15/35 60K steps

CJ2M-CPU3@: 270 µs

Overhead Processing Time*1

Normal Mode:

Execution Time

Basic Instructions: 0.016 µs min.; Special Instructions: 0.048 µs min.

Basic Instructions: 0.04 µs min.; Special Instructions: 0.06 µs min.

Interrupts

I/O Interrupts and External Interrupts

Interrupt task startup time: 26 µs or 17 µs*2 (30 µs for unit version 1.0) Return times to cyclic tasks: 11 µs or 8 µs*2 (15 µs for unit version 1.0)

Interrupt task startup time: 31 µs Return times to cyclic tasks: 10 µs

Scheduled Interrupts

Minimum time interval: 0.2 ms or 0.1 ms*2 (set in 0.1-ms increments)

Minimum time interval: 0.4 ms (set in 0.1-ms increments)

Interrupt task startup time: 22 µs or 13 µs*2 (27 µs for unit version 1.0) Return time to cyclic task: 11 µs or 8 µs*2 (15 µs for unit version 1.0)

Interrupt task startup time: 30 µs Return time to cyclic task: 11 µs

Maximum Number of Connectable Units

CJ2H-CPU@@:

Normal Mode:

CPU 13/33

100 µs

CJ2M-CPU1@: 160 µs

Total per CPU Rack or Expansion Rack: 10 Units max.; Total per PLC: 40 Units max.

Basic I/O Units

No limit However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted.

Special I/O Units

Units for up to 96 unit numbers can be mounted. (Unit numbers run from 0 to 95. Units are allocated between 1 and 8 unit numbers.)

CPU Bus Units

CJ2H-CPU6@-EIP: 15 Units max. CJ2H-CPU6@: 16 Units max.

CJ2M-CPU3@: 15 Units max. CJ2M-CPU1@: 16 Units max.

Pulse I/O Modules

---

2 max.*3

Slots for which interrupts can be used

CJ2H-CPU6@-EIP: Slots 0 to 3 on CPU Rack CJ2H-CPU6@: Slots 0 to 4 on CPU Rack

Slots 0 to 4 on CPU Rack

Maximum Number of Expansion Racks

3 max.

CIO Area

2,560 bits (160 words): Words CIO 0000 to CIO 0159

I/O Area Link Area

3,200 bits (200 words): Words CIO 1000 to CIO 1199

Synchronous Data Refresh Area

1,536 bits (96 words): Words CIO 1200 to CIO 1295

---

CPU Bus Unit Area

6,400 bits (400 words): Words CIO 1500 to CIO 1899

Special I/O Unit Area

15,360 bits (960 words): Words CIO 2000 to CIO 2959

Pulse I/O Area

---

20 inputs, 12 outputs (CIO 2960 to CIO 2963)

Serial PLC Link Words

---

1,440 bits (90 words): Words CIO 3100 to CIO 3189

DeviceNet Area

9,600 bits (600 words): Words CIO 3200 to CIO 3799

Internal I/O Area

3,200 bits (200 words): Words CIO 1300 to CIO 1499 (Cannot be used for external I/O.) 37,504 bits (2,344 words): Words CIO 3800 to CIO 6143 (Cannot be used for external I/O.)

Work Area Holding Area

8,192 bits (512 words): Words W000 to W511 (Cannot be used for external I/O.) 8,192 bits (512 words): Words H000 to H511 Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed. Words H512 to H1535: These words can be used only for function blocks. They can be used only for function block instances (i.e., they are allocated only for internal variables in function blocks).

*1 The following times are added if EtherNet/IP data tag links are used for the CJ2H-CPU6@-EIP. Normal operation: 100 µs + Number of transfer words x 0.33 µs High-speed interrupt function enabled: 100 µs + Number of transfer words × 0.87 µs The following time must be added when using EtherNet/IP tag data links for the CJ2M-CPU3@. 100 µs + (Number of words transferred × 1.8 µs) The following time must be added when using Pulse I/O Modules with a CJ2M CPU Unit: 10 µs × Number of Pulse I/O Modules *2 This applies when high-speed interrupts are used. *3 Supported only by CJ2M CPU Units with unit version 2.0 or later. A Pulse I/O Module must be mounted.

1-14

CJ2 CPU Unit Hardware User’s Manual

Page 57

1 Overview

CPU64 (-EIP)

Auxiliary Area

CPU65 (-EIP)

CJ2M-

CPU66 (-EIP)

CPU67 (-EIP)

CPU68 (-EIP)

CPU 11/31

CPU 12/32

CPU 13/33

CPU 14/34

CPU 15/35

Read-only: 31,744 bits (1,984 words) • 7,168 bits (448 words): Words A0 to A447 • 24,576 bits (1,536 words): Words A10000 to A11535*4 Read/write: 16,384 bits (1,024 words) in words A448 to A1471*4 16 bits: TR0 to TR15

Timer Area

4,096 timer numbers (T0000 to T4095 (separate from counters))

Counter Area

4,096 counter numbers (C0000 to C4095 (separate from timers))

DM Area

32k words*5

1

• DM Area words for Special I/O Units: D20000 to D29599 (100 words × 96 Units) • DM Area words for CPU Bus Units: D30000 to D31599 (100 words × 16 Units) 32k words/bank × 25 banks max.: E00_00000 to E18_32767 max.*5, *6

32k words/bank × 4 banks max.: E00_00000 to E3_32767 max.*5

32K words × 4 banks

32K words × 4 banks

32K words × 10 banks

32K words × 15 banks

32K words × 25 banks

32K words × 1 bank

32K words × 4 banks

Using EM Area forcesetting/resetting

Banks 0 to 3 hex

Banks 0 to 3 hex

Banks 0 to 9 hex

Banks 0 to E hex

Banks 0 to 18 hex

Bank 0 hex

Banks 0 to 3 hex

Using automatic address allocation specifications

Bank 3 hex

Bank 3 hex

Banks 6 to 9 hex

Banks 7 to E hex

Banks 11 to 18 hex

---

EM Area

Banks for which bits can be forceset/reset*7

Index Registers

IR0 to IR15 These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can be set so that they are unique in each task or so that they are shared by all tasks.)

Cyclic Task Flag Area

128 flags

Memory Card

128 MB, 256 MB, or 512 MB

Operating Modes

PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in this mode. MONITOR Mode:

Programs are executed, and some operations, such as online editing, and changes to present values in I/O memory, are enabled in this mode.

RUN Mode:

Programs are executed. This is the normal operating mode.

Execution Mode

Normal Mode

Programming Languages

Ladder Logic (LD) Sequential Function Charts (SFC) Structured Text (ST) Instruction Lists (IL)

Function Blocks

Maximum number of definitions

2,048

256

2,048

Maximum number of instances

2,048

256

2,048

---

20K steps

FB Program Area

*4 A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units. *5 Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units. *6 EM banks D to 18 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units. *7 With CJ2H CPU Units with unit version 1.2 or later, force-setting/resetting bits in the EM Area is possible either for banks that have been specified for automatic address allocation or for banks specified for the EM Area force-set/reset function. With CJ2M CPU Units, force-setting/resetting bits in the EM Area is possible only for banks specified for the EM Area force-set/reset function.

CJ2 CPU Unit Hardware User’s Manual

1-15

1-3-2 Performance Specifications

Temporary Area

1-3 Specifications

CJ2HItems

Page 58

1 Overview

CJ2HItems

Tasks

CPU64 (-EIP)

CPU65 (-EIP)

CPU66 (-EIP)

CJ2MCPU67 (-EIP)

CPU68 (-EIP)

CPU 11/31

CPU 12/32

CPU 13/33

CPU 14/34

CPU 15/35

Type of Tasks

Cyclic tasks Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, external interrupt tasks, and input interrupt tasks*3)

Number of Tasks

Cyclic tasks: 128 Interrupt tasks: 256 (Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic tasks is actually 384 max.)

Symbols (Variables)

Type of Symbols

Local symbols: Can be used only within a single task in the PLC. Global symbols: Can be used in all tasks in the PLC. Network symbols (tags)*8: I/O memory in the CPU Unit can be externally accessed using symbols, depending on parameter settings.

Data Type of Symbols

BOOL (bit) UINT (one-word unsigned binary) UDINT (two-word unsigned binary) ULINT (four-word unsigned binary) INT (one-word signed binary) DINT (two-word signed binary) LINT (four-word signed binary) UINT BCD (one-word unsigned BCD)*9 UDINT BCD (two-word unsigned BCD)*9 ULINT BCD (four-word unsigned BCD)*9 REAL (two-word floating-point) LREAL (four-word floating-point) CHANNEL (word) NUMBER (constant or number) WORD (one-word hexadecimal) DWORD (two-word hexadecimal) LWORD (four-word hexadecimal) STRING (1 to 255 ASCII characters) TIMER (timer)*10 COUNTER (counter)*10 User-defined data types (data structures)*11

Maximum Size of Symbol

32k words

Array Symbols (Array Variables)

One-dimensional arrays

Number of Array Elements

32,000 elements max.

Number of Registrable Network Symbols (Tags)*8

20,000 max.

Length of Network Symbol (Tag) Name*8

255 bytes max.

Encoding of Network Symbols (Tags)*8

UTF-8

2,000 max.

*8 Supported only by the CJ2H-CPU6@-EIP and CJ2M-CPU3@. *9 This data type cannot be used in Function blocks. *10 This data type can be used only in Function blocks. *11 Supported only when CX-Programmer version 9.0 or higher is used.

1-16

CJ2 CPU Unit Hardware User’s Manual

Page 59

1 Overview

Data Tracing

Memory Capacity

CPU64 (-EIP)

CPU65 (-EIP)

8,000 words

CJ2M-

CPU66 (-EIP)

CPU67 (-EIP)

CPU68 (-EIP)

16,000 words

32,000 words

(Up to 32k words x 25 banks when EM is specified in CX-Programmer) Number of Samplings

CPU 11/31

CPU 12/32

CPU 13/33

CPU 14/34

CPU 15/35

8,000 words (Up to 32k words x 4 banks when EM is specified in CX-Programmer)

Bits = 31, one-word data =16, two-word data = 8, four-word data = 4 1 to 2,550 ms (Unit: 1 ms)

Trigger Conditions

ON/OFF of specified bit Data comparison of specified word Data size: 1 word, 2 words, 4 words Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (≥), Less Than (<), Less Than or Equals (≤), Not Equal (≠)

Delay Value

−32,768 to +32,767 ms Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.) EM file memory (Part of the EM Area can be converted for use as file memory.)

Source/Comment Memory

Program source, comments, program index, and symbol table

CJ2 CPU Unit Hardware User’s Manual

Capacity: 3.5 Mbytes

Capacity: 1 Mbytes

1-17

1 1-3-2 Performance Specifications

Sampling Cycle

File Memory

1-3 Specifications

CJ2HItems

Page 60

1 Overview

CJ2HItem

Communications

CPU64 (-EIP)

CPU65 (-EIP)

CPU66 (-EIP)

CJ2MCPU67 (-EIP)

CPU68 (-EIP)

CPU 11/31

CPU 12/32

CPU 13/33

Logical Ports for Communications

Logical Ports Extended Logical Ports

64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.)

CIP Communications Specification

Class 3 (Number of Connections)

Number of connections: 64

UCMM (Non-connection Type)

Maximum number of clients that can communicate at the same time: 32 Maximum number of servers that can communicate at the same time: 40

Peripheral (USB) Port Baud Rate Transmission Distance Serial Port

CPU 14/34

CPU 15/35

8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.)

USB 2.0-compliant B-type connector 12 Mbps max. 5 m max. Interface: Conforms to EIA RS-232C.

• CJ2M-CPU1@ interface: Conforms to EIA RS-232C. • CJ2M-CPU3@: No serial ports with default system One of the following Serial Option Boards can be mounted. • CP1W-CIF01 RS-232C Option Board • CP1W-CIF11 RS-422A/485 Option Board (not isolated, max. transmission distance: 50 m) • CP1W-CIF12 RS-422A/485 Option Board (isolated, max. transmission distance: 500 m)

Communications Method

Half-duplex

Synchronization Method

Start-stop

Baud Rate

0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps)

Transmission Distance

Transmission Specifications

EtherNet/IP Port*12 Media Access Method

CSMA/CD

Modulation

Baseband

Transmission Paths

Star

Baud Rate

100 Mbps (100Base-TX)

Transmission Media

Shielded twisted-pair (STP) cable; Categories: 5, 5e

Transmission Distance

100 m (between Ethernet switch and node)

Number of Cascade Connections

No restrictions if Ethernet switch is used.

CIP Communications: Tag Data Links Communications Specifications

15 m max. ---

---

Number of Connections

256

32

Packet Interval (Refresh period)

0.5 to 10,000 ms (Unit: 0.5 ms) Can be set for each connection. (Data will be refreshed at the set interval, regardless of the number of nodes.)

1 to 10,000 ms (in 0.5-ms increments) Can be set for each connection. (Data will be refreshed at the set interval, regardless of the number of nodes.)

Permissible Communications Band

6,000 packets per second*13

3,000 packets per second*13

Number of Registrable Tags

256

32

Type of Tags

CIO, DM, EM, HR, WR, and network symbols

Number of Tags per Connection

8 (Seven tags if PLC status is included in the segment.)

*12 The EtherNet/IP port is built into the CJ2H-CPU6@-EIP and CJ2M-CPU3@ only. *13 “Packets per second” is the number of communications packets that can be processed per second.

1-18

CJ2 CPU Unit Hardware User’s Manual

Page 61

1 Overview

CPU65 (-EIP)

CPU66 (-EIP)

CJ2MCPU67 (-EIP)

CPU68 (-EIP)

CPU 11/31

CPU 12/32

CPU 13/33

CPU 14/34

CPU 15/35

Maximum Link Data Size per Node

184,832 words

640 words

Maximum Data Size per Connection

252 or 722 words*14 (Data is synchronized within each connection.)

640 words (Data is synchronized within each connection.)*15

Number of Registrable Tag Set

256 (1 connection = 1 segment)

32 (1 connection = 1 segment)

Maximum Tag Set Size

722 words (One word is used when PLC status is included in the segment.)

640 words (One word is used when PLC status is included in the segment.)*15

Maximum Number of Tags Refreshable in a Single Cycle of CPU Unit*16

Output/send (CPU Unit to EtherNet/IP): 256 Input/receive (EtherNet/IP to CPU Unit): 256

Output/send (CPU Unit to EtherNet/IP): 32 Input/receive (EtherNet/IP to CPU Unit): 32

Data Size Refreshable in a Single Cycle of CPU Unit*16

Output/send (CPU to EtherNet/IP): 6,432 words Input/receive (EtherNet/IP to CPU): 6,432 words

Output/send (CPU Unit to EtherNet/IP): 640 words Input/receive (EtherNet/IP to CPU Unit): 640 words

Change of Tag Data Link Parameter Settings during Operation

OK*17

Multi-cast Packet Filter*18

OK

CIP Communications: Explicit Messages

---

Class 3 (Number of Connections)

Number of connections: 128

UCMM (Non-connection Type)

Maximum number of clients that can communicate at the same time: 32 Maximum number of servers that can communicate at the same time: 32

CIP Routing

OK (CIP routing is enabled for the following remote Units: CJ1W-EIP21, CJ2H-CPU6@-EIP, CJ2MCPU3@, and CS1W-EIP21.)

FINS Communications

Maximum number of clients that can communicate at the same time: 16 Maximum number of servers that can communicate at the same time: 16

---

FINS/UDP

OK

FINS/TCP

16 connections max.

EtherNet/IP Conformance Test

Conforms to A5.

EtherNet/IP Interface

10Base-T/100Base-TX Auto Negotiation/Fixed Setting

*14 Large Forward Open (CIP optional specification) must be supported in order for 505 to 1,444 bytes to be used as the data size. Application is supported between CS/CJ-series PLCs. When connecting to devices from other manufacturers, make sure that the devices support the Large Forward Open specification. *15 Unit version 2.0 of built-in EtherNet/IP section: 20 words *16 If the maximum number is exceeded, refreshing will require more than one CPU Unit cycle. *17 When changing parameters, however, the EtherNet/IP port where the change is made will be restarted. In addition, a timeout will temporarily occur at the other node that was communicating with that port, and it will then recover automatically. *18 The EtherNet/IP port supports an IGMP client, so unnecessary multicast packets are filtered by using an Ethernet switch that supports IGMP snooping.

CJ2 CPU Unit Hardware User’s Manual

1-19

1 1-3-2 Performance Specifications

Communications Specifications

Communications

CPU64 (-EIP)

1-3 Specifications

CJ2HItem

Page 62

1 Overview

CJ2HItem

Pulse I/O*3

External interface

CPU64 (-EIP) ---

Pulse Inputs

CPU65 (-EIP)

CPU66 (-EIP)

CJ2MCPU67 (-EIP)

CPU68 (-EIP)

CPU 11/31

CPU 12/32

CPU 13/33

CPU 14/34

CPU 15/35

CJ2M-MD211 or CJ2M-MD212 Pulse I/O Module with 40-pin MIL connector Can be used as normal inputs, interrupt inputs, quick-response inputs, or high-speed counter inputs. (Functions of each input must be selected in the PLC Setup.) Input method: Line-driver input or 24-VDC input (selected by wiring)

Normal inputs

20 max. (10 per Pulse I/O Module) Input constants: Set in the PLC Setup (0, 0.5, 1, 2, 4, 8, 16, or 32 ms). Default: 8 ms

Interrupt inputs and quickresponse inputs

8 max. (4 per Pulse I/O Module) Input signal minimum ON pulse width: 30 µs

High-speed counter inputs

4 max. (2 per Pulse I/O Module) Input method: Differential-phase (×4) pulses, pulse + direction, up/down pulses, or increment pulse Maximum response frequency: 50 kHz for differential phases or 100 kHz for single phase Counting mode: Linear mode or circular (ring) mode Count value: 32 bits Counter reset: Phase Z + software reset or software reset Control method: Target-value comparison or range comparison Gate function: Supported

Pulse Outputs

Can be used as normal outputs, pulse outputs, or PWM outputs. (Functions of each output must be selected in the PLC Setup.) Output method: Sinking or sourcing transistor outputs (The method is determined by Pulse I/O Module model.)

Normal outputs Pulse outputs

---

12 max. (6 per Pulse I/O Module) 4 max. (2 per Pulse I/O Module) Output method: CW/CCW or pulse + direction (The method is determined by the I/O wiring and the instructions used in the ladder program.) Output frequency: 1 pps to 100 kpps (in increments of 1 pps) Output Mode: Continuous mode (for speed control) or independent mode (for position control) Output pulses: Relative coordinates: 0000 0000 to 7FFF FFFF hex (0 to 2,147,483,647 pulses) Absolute coordinates: 8000 0000 to 7FFF FFFF hex (−2,147,483,648 to 2,147,483,647) Acceleration/deceleration curves: Linear or Scurve Origin search function: Supported

PWM outputs

4 max. (2 per Pulse I/O Module) Output frequency: 0.1 to 6,553.5 Hz (in 0.1-Hz increments) or 1 to 32,800 Hz (in 1-Hz increments) Duty ratio: 0.0% to 100.0% (in 0.1% increments)

1-20

CJ2 CPU Unit Hardware User’s Manual