Page 343
Appendices z Inputs and Outputs Programmable Controller I/O Unit
CJ1W-MD231
ConnectorTerminal Block Conversion Unit
XW2D-20G6
Connecting Cables
XW2Z-@@@A
CN1
Wd m
+V COM (0 V) 07
L
06
L
05
L 12 to 24 VDC
04
L
03
L
02 01
L
00
L
B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 A2 B1
+V COM (0 V) 15 14 13 12 11 10 09 08
L L L L
12 to 24 VDC
L L
A-1 Specifications of Basic I/O Units
L
B10 A10
(OUT)
L L
A1
Connection diagram CN2
Wd (m+1)
B10 NC COM
06 05 04 03 02 01 00
B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 A2 B1
COM 15 14 13 12 11
24 VDC
10 09 08
A1
Note 1 The polarity for input power supply connections indicated with dotted lines ( tion.
) can be connected in either direc-
2 The COM terminals are internally connected inside the PLC, but they must all be wired.
CJ2 CPU Unit Hardware User’s Manual
A-81
A-1-4 Connecting Connector-Terminal Block Conversion Units and I/O Relay Terminals
24 VDC
B9 A9
NC
App
07
A10
(IN)
Page 344
Appendices
Programmable Controller I/O Unit
CJ1W-MD231
Connector-Terminal Block Conversion Unit
XW2C-20G6-IO16
Connecting Cables
XW2Z-@@@A CN1
(Short bar)
COM0 (COM1)
Wd m
(OUT)
CN2
− − A10 B10
−
+V
A10 B10 A9 B9
+ +
+
(Short bar)
+ −
− 15
15
+
+
14
14
14
Solenoid valve, etc.
−
−
13
13
13
+
12
+ −
− 11
11
+
+
10
10
10
9
9
Connection diagram
8
8
−
−
07
+
+
−
− 5
5
4
4
3
3
+
02
+
−
Solenoid valve, etc.
+
Blue (Black)
+
2-wire sensor (e.g., limit switch)
Brown (White)
−
− +
24 VDC
12 to 24 VDC
Note 1 Connect the A9/B9 terminal and the Note 1 terminal. Connect the A10/B10 terminal and the terminal. (Use the enclosed short bar.) 2 The COM terminals are wired inside the Connector-Terminal Block Conversion Unit.
A-82
NPN
0
0
+
− 1
1 00
3-wire sensor with NPN output (photoelectric sensor or proximity sensor)
2
2 01
Brown (Red) Blue (Black)
−
−
03
Black (White)
+
+
04
Brown (White) 2-wire sensor (e.g., limit switch)
6
6 05
PNP
7
7 06
Blue (Black) 3-wire sensor with PNP output (photoelectric sensor or proximity sensor)
Blue (Black)
+
+
08
Brown (Red)
−
−
09
Black (White)
12
12 11
Wd (m+1)
−
(Short bar)
A9 B9
15
(IN)
Connect the A9/B9 terminal and the terminal for NPN. Connect the A9/B9 terminal and the terminal for PNP. (Use the enclosed short bar.)
2 The COM terminals are wired inside the Connector-Terminal Block Conversion Unit.
CJ2 CPU Unit Hardware User’s Manual
Page 345
Appendices
Programmable Controller I/O Unit
CJ1W-MD232
Programmable Controller I/O Unit
CJ1W-MD233
ConnectorTerminal Block Conversion Unit
XW2D-20G6
ConnectorTerminal Block Conversion Unit
XW2D-20G6
Connecting Cables
XW2Z-@@@X
Connecting Cables
XW2Z-@@@X
CN1
Wd m
(OUT) CN1
Wd m L L L L L L L L
08 09 10 11 12 13 14 15
COM (+V) 0V
Wd (m+1)
A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 A2 B1
00 01 02 03 04 05 06 07
L L
L
L
L
L
L
L
L 12 to 24 VDC
L L L
L L
COM (+V) 0V
L
L 24 VDC
08 09 10 11 12 13 14 15
COM (0 V)
A1
+V
CN2
(OUT)
08 09 24 VDC 10 11 12 13
15 COM
B9 A9 B8 A8 B7
Wd (m+1)
A7 B6 A6 B5 A5 B4 A4 B3 A3 B2
09
01
10
02
11 24 VDC
12
04
13
05
14
06
15
07
COM
COM
B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 A2 B1
02 03 04 05 06 07
L L L L L
12 to 24 VDC
L L L
COM (0 V) +V
A1
CN2
B10 A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2
00 01 02 03 04
24 VDC
05 06 07 COM
A2 B1
NC
(IN)
NC
A1
NC
A1
Note 1 The polarity for input power supply connections indicated with dotted lines ( ) can be connected in either direction.
Note 1 The polarity for input power supply connections indicated with dotted lines ( ) can be connected in either direction.
2 The COM terminals and 0V terminal are internally connected inside the PLC, but they must all be wired.
2 The COM terminals and +V terminals are internally connected inside the PLC, but they must all be wired.
CJ2 CPU Unit Hardware User’s Manual
A-83
A-1-4 Connecting Connector-Terminal Block Conversion Units and I/O Relay Terminals
A2 B1
NC
00
03
A9
01
App
14
A10
B9
00
Connection diagram
08
B10
B10 A10
(OUT)
A-1 Specifications of Basic I/O Units
Connection diagram
B10
Page 346
Appendices
Programmable Controller I/O Unit
CJ1W-MD261
Connector-Terminal Block Conversion Unit
XW2D-40G6
Connecting Cables
XW2Z-@@@B
XW2D-40G6RF
CN1
(OUT)
+V COM0
B20 A20 B19 A19 B18
L
15
L
14
A17
L
13
A16
L
12
L
11
L
10
L
09
L
08
Connection diagram
+V COM0
12 to 24 VDC
CN2
L
07
L
06
L
05
L
04
L
03
L
02
L
01
L
00
A18 B17 B16 B15 A15 B14 A14 B13 A13 B12 A12 B11 A11 B10 A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 A2 B1 A1
Wd (m+3)
+V NC COM1 NC 15 14 13 12 11 10 09 08
L
COM2
L L L L
13
A15
09
06 05 04
L
L L
02
L
00
06
L
03
01
07
L L
05 12 to 24 VDC
24 VDC
04 03 02 01 00
14
B15
13
B14
12
B13
11
B12
10
B11 A11
A9
COM3
B16
A12
COM2
NC
15
A13
A10
NC
B17
A14
08 COM1
L
B18 A18
A16
10
L
B19 A19
14
11
L
A20
A17
12
L
B20
15
+V
07
(IN)
Wd (m+2)
Wd (m+1)
Wd m
09
B10
08
B9
COM3
B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 A2 B1
07 06 05 04
24 VDC
03 02 01 00
A1
Note The +V terminals and COM terminals are Note 1 The polarity for input power supply coninternally connected inside the PLC, but nections indicated with dotted lines they must all be wired. ( ) can be connected in either direction provided that the same polarity is used for the commons for rows A and B. 2 Both COM2 and COM3 have two pins each. They are internally connected inside the PLC, but they must all be wired.
A-84
CJ2 CPU Unit Hardware User’s Manual
Page 347
Appendices
Programmable Controller I/O Unit
CJ1W-MD261
Connector-Terminal Block Conversion Unit
XW2C-20G6-IO16 (2 Units)
XW2C-20G6-IO16 (2 Units)
Connecting Cables
XW2Z-@@@L
XW2Z-@@@D CN2
(Short bar)
COM0 (COM1)
Wd m (Wd (m+1))
(OUT)
− − A10 B10
CN2
+
15
− A10 B10 A9 B9
+
(Short bar)
+
−
−
15
15
+
14
14
+ Solenoid valve, etc.
14
−
13
−
13
13
+
12
+
12
−
11
11
+
10
+
10
10
−
09
9 8
−
−
7
+
6
6
−
05
−
5
+
4
4
−
03
3
+
+
2
−
−
Blue (Black)
+
2-wire sensor (e.g., limit switch)
Brown (White)
1
+ 0
0
−
− +
12 to 24 VDC
Note 1 Connect the A9/B9 terminal and the Note 1 terminal. Connect the A10/B10 terminal and the terminal. (Use the enclosed short bar.) 2 The COM terminals are wired inside the Connector-Terminal Block Conversion Unit.
24 VDC
Connect the A9/B9 terminal and the terminal for NPN. Connect the A9/B9 terminal and the terminal for PNP. (Use the enclosed short bar.)
2 The COM terminals are wired inside the Connector-Terminal Block Conversion Unit.
A-85
A-1-4 Connecting Connector-Terminal Block Conversion Units and I/O Relay Terminals
+
CJ2 CPU Unit Hardware User’s Manual
NPN
2 Solenoid valve, etc.
1 00
3-wire sensor with NPN output (photoelectric sensor or proximity sensor)
App
01
Brown (Red) Blue (Black)
−
3 02
Black (White)
5
+
04
Brown (White) 2-wire sensor (e.g., limit switch)
7
+
06
PNP
Blue (Black)
+
8 07
Blue (Black) 3-wire sensor with PNP output (photoelectric sensor or proximity sensor)
A-1 Specifications of Basic I/O Units
+
08
Brown (Red)
−
9
Connection diagram
Black (White)
12
−
11
Wd (m+2) (Wd (m+3))
−
(Short bar)
+V
A9 B9
+
(IN)
Page 348
Appendices
Programmable Controller I/O Unit
CJ1W-MD263
Connector-Terminal Block Conversion Unit
XW2D-40G6
Connecting Cables
XW2Z-@@@K
XW2D-40G6-RM
CN1
CN2
(OUT)
(IN)
12 to 24 VDC 24 VDC
B20
L
08
L
09
A19
L
10
A18
L
11
A17
L
12
L
13
L
14
L
15
COM0 +V
Connection diagram L
08
L
09
L
10
L
11
L
12
L
13
L
14
L
15
A20 B19
COM1 +V
01
B18
02
B17
03
L
08
A20
L
09
A19
L
10
A18
11
A17
L Wd m
B16 A16 B15 A15 B14 A14 B13 A13 B12 A12 B11 A11 B10 A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3
04
L
12
05
L
13
L
14
L
15
06 07
COM0
COM2
01 02 03 04 05 06 07
A2 B1 A1
00
B19
01
B18
02
B17
03
B16
04
B15
05
B14
06
A15 A14 B13 A13 B12
L
08
L
09
L
10
L
11
L
12
L
Wd (m+1)
13
L
14
L
15 COM3
COM1
A11 B10 A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3
NC
07 COM2
B2
NC 00 01 02 03 04 05
Wd (m+3)
06 07 COM3
A2 B1
+V
Wd (m+2)
A12 B11
NC 00
B20
A16
+V
A3 B2
12 to 24 VDC
00
NC
A1
24 VDC
Note The +V terminals and COM terminals are Note 1 The polarity for input power supply coninternally connected inside the PLC, but nections indicated with dotted lines they must all be wired. ( ) can be connected in either direction. 2 Both COM2 and COM3 have two pins each. They are internally connected inside the PLC, but they must all be wired.
A-86
CJ2 CPU Unit Hardware User’s Manual
Page 349
Appendices
Programmable Controller I/O Unit
CJ1W-MD263
Connector-Terminal Block Conversion Unit
XW2C-20G6-IO16 (2 Units)
Connecting Cables
XW2Z-@@@N CN1
(Short bar)
COM0 (COM1)
Wd m (Wd (m+1))
(OUT)
− − A10 B10 A9 B9
+
+
CN2
−
(Short bar)
−
+V
A10 B10 A9 B9
+
(Short bar)
+
−
15
−
15
15
+
14
14
+ 14
Solenoid valve, etc.
−
13
−
13
13
+
12
+
12
−
11
11
+
10
+
10
10
−
09
9 8
−
−
7
+
6
6
−
−
05
5
5
+
04
4
−
−
3
3
+
02
+
2
−
Solenoid valve, etc.
1
+
Blue (Black)
2-wire sensor (e.g., limit switch)
0
−
− 12 to 24 VDC
2 The COM terminals are wired inside the Connector-Terminal Block Conversion Unit.
24 VDC
Connect the A9/B9 terminal and the terminal for NPN. Connect the A9/B9 terminal and the terminal for PNP. (Use the enclosed short bar.)
2 The COM terminals are wired inside the Connector-Terminal Block Conversion Unit.
A-87
A-1-4 Connecting Connector-Terminal Block Conversion Units and I/O Relay Terminals
+
Note 1 Connect the A9/B9 terminal and the Note 1 terminal. Connect the A10/B10 terminal and the terminal. (Use the enclosed short bar.)
CJ2 CPU Unit Hardware User’s Manual
NPN
Brown (White)
+
0
+
Blue (Black) 3-wire sensor with NPN output (photoelectric sensor or proximity sensor)
App
1 00
Brown (Red)
2
−
01
Black (White)
+
4 03
Brown (White) 2-wire sensor (e.g., limit switch)
7
+
06
PNP
Blue (Black)
+
8 07
Blue (Black) 3-wire sensor with PNP output (photoelectric sensor or proximity sensor)
A-1 Specifications of Basic I/O Units
+
08
Brown (Red)
−
9
Connection diagram
Black (White)
12
−
11
Wd (m+2) (Wd (m+3))
(IN)
Page 350
Appendices
Programmable Controller I/O Unit
CJ1W-MD563
Connector-Terminal Block Conversion Unit
XW2D-40G6
Connecting Cables
XW2Z-@@@K
XW2D-40G6-RM
CN2 CN1
5 VDC
5 VDC
L L L
08 09 10
L
11
L
12
L L L
13 14 15
COM0 +V
Connection diagram L L L L L
08 09 10 11 12
L
13
L
14
L
15
B20 A20 B19 A19
COM1 +V
00 01
L
02
L
B17
03
L
B16
04
L
05
L
06
L
07
L
A18
Wd m
A17 A16 B15 A15 B14 A14 B13 A13 B12 A12 B11 A11 B10 A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3
A19
10
A18
11
A17
14 15 COM2
08
L
01
L
02
L
03
L
04
L
05
L
06
L
09 10 11 12 13
Wd (m+1)
14 15
L
COM3
A2 B1
B20
00
B19
01
B18
02
B17
03
B16
04
B15
05
B14
06
B13
07
A16 A15 A14 A13 B12
A11 B10 A10 B9 A9 B8 A8 B7 A7 B6 A6 B5 A5 B4 A4 B3 A3 B2 B1
NC
COM2 NC 00 01 02 03 04 05
Wd (m+3)
06 07 COM3
A2
COM1 +V
Wd (m+2)
A12 B11
NC
A3
A1
09
13
+V
07
A20
12
COM0
00
08
L
B18
B2 5 VDC
(IN)
(OUT)
NC
A1
5 VDC
Note 1 The +V terminals and COM terminals Note 1 The COM terminals are internally conare internally connected inside the PLC, nected inside the PLC, but they must all but they must all be wired. be wired. 2 The power supply voltage for the CJ1WMD563 is 5 V.
A-88
2 The power supply voltage for the CJ1WMD563 is 5 V.
CJ2 CPU Unit Hardware User’s Manual
Page 351
Appendices
Connection Diagrams for I/O Relay Terminals Connection examples and internal connection diagrams for I/O Relay Terminals connected to Basic I/O Units are shown below.
z Inputs G7TC I/O Relay Terminals G7TC-ID16
G7TC-IA16
G7TC 15
14
13
12
11
10
08
07
06
05
04
03
01
15
C15
14
C14
14
14
C14
13
C13
13
13
C13
12
C12
12
12
C12
11
C11
11
11
C11
10
C10
10
10
C10
9
C9
09
9
C9
8
C8
08
8
C8
7
C7
07
7
C7
6
C6
06
6
C6
5
C5
05
5
C5
4
C4
04
4
C4
3
C3
03
3
C3
2
C2
02
2
C2
1
C1
01
1
C1
0
C0
00
0
C0 NC
Relay side
Relay side
NC
NC
NC
+
−
+
PLC
− PLC
TOP VIEW
TOP VIEW
Note 1 Inputs to the PLC Input Units and I/O Relay Terminals use isolated contacts. “00” to “15” are the input bit numbers for the PLC Input Unit and the input numbers for the I/O Relay Terminal.
Note 1 Inputs to the PLC Input Units and I/O Relay Terminals use isolated contacts. “00” to “15” are the input bit numbers for the PLC Input Unit and the input numbers for the I/O Relay Terminal.
2 Use the G78-04 short bar to short to the common terminal.
2 Use the G78-04 short bar to short to the common terminal.
CJ2 CPU Unit Hardware User’s Manual
A-89
A-1-4 Connecting Connector-Terminal Block Conversion Units and I/O Relay Terminals
00
15
App
02
C15
A-1 Specifications of Basic I/O Units
09
G7TC
15
Page 352
Appendices z Outputs G70D-V Relay Terminals G70D-VSOC16
G70D-VSOC16+G70D-ET
Power supply
Power supply G70D-VSOC16
G70D-VSOC16
G70D-ET
15
A15
B15
A15
B15
15
14
A14
B14
A14
B14
14
13
A13
B13
A13
B13
13
12
A12
B12
A12
B12
12
11
A11
B11
A11
B11
11
10
A10
B10
A10
B10
10
09
A9
B9
A9
B9
09
08
A8
B8
A8
B8
08
07
A7
B7
A7
B7
07
06
A6
B6
A6
B6
06
05
A5
B5
A5
B5
05
L
04
A4
B4
A4
B4
04
L
03
A3
B3
A3
B3
03
L
02
A2
B2
A2
B2
02
L
01
A1
B1
A1
B1
01
L
00
A0
B0
A0
B0
00
L
L
L
L
L
L
L
L
L
L
L
Back side 24 VDC
0
Back side
24 VDC
L
C15
L
C14
L
C13
L
C12
L
C11
L
C10
L
C9
L
C8
L
C7
L
C6
L
C5
L
C4
L
C3
L
C2
L
C1
L
C0
0 PLC
PLC
TOP VIEW
TOP VIEW
Note 1 All outputs are independent. Outputs on the PLC Output Unit and I/O Relay Terminal are isolated. “00” to “15” are the output bit numbers for the PLC Output Unit and the output numbers for the I/O Relay Terminal.
Note 1 All outputs are independent. Outputs on the PLC Output Unit and I/O Relay Terminal are isolated. “00” to “15” are the output bit numbers for the PLC Output Unit and the output numbers for the I/O Relay Terminal.
2 Use the G6D-4-SB short bar to short to the common terminal.
2 Use the G6D-4-SB short bar to short to the common terminal.
A-90
CJ2 CPU Unit Hardware User’s Manual