Page 154

5-16 Data Movement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-1 MOVE – MOV(21) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-2 MOVE NOT – MVN(22) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-3 BLOCK SET – BSET(71) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-4 BLOCK TRANSFER – XFER(70) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-5 DATA EXCHANGE – XCHG(73) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-6 SINGLE WORD DISTRIBUTE – DIST(80) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-7 DATA COLLECT – COLL(81) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-8 MOVE BIT – MOVB(82) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-9 MOVE DIGIT – MOVD(83) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-10 TRANSFER BITS – XFRB(62) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-11 EM BLOCK TRANSFER – XFR2(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16-12 EM BANK TRANSFER – BXF2(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17 Data Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-1 MULTI-WORD COMPARE – MCMP(19) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-2 COMPARE – CMP(20) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-3 DOUBLE COMPARE – CMPL(60) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-4 BLOCK COMPARE – BCMP(68) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-5 TABLE COMPARE – TCMP(85) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-6 AREA RANGE COMPARE – ZCP(88) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-7 DOUBLE AREA RANGE COMPARE – ZCPL(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-8 SIGNED BINARY COMPARE – CPS(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17-9 DOUBLE SIGNED BINARY COMPARE – CPSL(––) . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18 Data Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-1 BCD-TO-BINARY – BIN(23) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-2 DOUBLE BCD-TO-DOUBLE BINARY – BINL(58) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-3 BINARY-TO-BCD – BCD(24) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-4 DOUBLE BINARY-TO-DOUBLE BCD – BCDL(59) . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-5 HOURS-TO-SECONDS – SEC(65) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-6 SECONDS-TO-HOURS – HMS(66) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-7 4-TO-16/8-TO-256 DECODER – MLPX(76) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-8 16-TO-4/256-TO-8 ENCODER – DMPX(77) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-9 7-SEGMENT DECODER – SDEC(78) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-10 ASCII CONVERT – ASC(86) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-11 ASCII-TO-HEXADECIMAL – HEX(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-12 SCALING – SCL(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-13 COLUMN TO LINE – LINE(63) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-14 LINE TO COLUMN – COLM(64) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-15 2’S COMPLEMENT – NEG(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18-16 DOUBLE 2’S COMPLEMENT – NEGL(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19 BCD Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-1 INCREMENT – INC(38) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-2 DECREMENT – DEC(39) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-3 SET CARRY – STC(40) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-4 CLEAR CARRY – CLC(41) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-5 BCD ADD – ADD(30) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-6 DOUBLE BCD ADD – ADDL(54) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-7 BCD SUBTRACT – SUB(31) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-8 DOUBLE BCD SUBTRACT – SUBL(55) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-9 BCD MULTIPLY – MUL(32) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-10 DOUBLE BCD MULTIPLY – MULL(56) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-11 BCD DIVIDE – DIV(33) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-12 DOUBLE BCD DIVIDE – DIVL(57) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-13 FLOATING POINT DIVIDE – FDIV(79) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19-14 SQUARE ROOT – ROOT(72) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20 Binary Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-1 BINARY ADD – ADB(50) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-2 BINARY SUBTRACT – SBB(51) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-3 BINARY MULTIPLY – MLB(52) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-4 BINARY DIVIDE – DVB(53) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-5 DOUBLE BINARY ADD – ADBL(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-6 DOUBLE BINARY SUBTRACT – SBBL(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-7 SIGNED BINARY MULTIPLY – MBS(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-8 DOUBLE SIGNED BINARY MULTIPLY – MBSL(––) . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-9 SIGNED BINARY DIVIDE – DBS(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20-10 DOUBLE SIGNED BINARY DIVIDE – DBSL(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

136

180 180 180 181 182 183 183 185 187 188 189 190 191 192 192 193 196 197 199 200 201 202 203 204 204 205 205 206 207 208 209 212 215 218 219 222 224 225 226 227 228 228 228 229 229 229 230 231 233 235 236 236 237 238 241 243 243 245 248 248 249 251 253 254 255 256

Page 155

5-21 Special Math Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-1 FIND MAXIMUM – MAX(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-2 FIND MINIMUM – MIN(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-3 AVERAGE VALUE – AVG(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-4 SUM – SUM(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-5 ARITHMETIC PROCESS – APR(69) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21-6 PID CONTROL – PID(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22 Logic Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22-1 COMPLEMENT – COM(29) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22-2 LOGICAL AND – ANDW(34) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22-3 LOGICAL OR – ORW(35) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22-4 EXCLUSIVE OR – XORW(36) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22-5 EXCLUSIVE NOR – XNRW(37) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23 Subroutines and Interrupt Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23-1 Subroutines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23-2 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23-3 SUBROUTINE ENTER – SBS(91) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23-4 SUBROUTINE DEFINE and RETURN – SBN(92)/RET(93) . . . . . . . . . . . . . . . . . . . . . 5-23-5 MACRO – MCRO(99) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23-6 INTERRUPT CONTROL – INT(89) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23-7 Processing the Same Memory Locations with the Main Program and Interrupt Subroutines 5-24 Step Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24-1 STEP DEFINE and STEP START–STEP(08)/SNXT(09) . . . . . . . . . . . . . . . . . . . . . . . . . 5-25 Special Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-1 FAILURE ALARM – FAL(06) and SEVERE FAILURE ALARM – FALS(07) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-2 CYCLE TIME – SCAN(18) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-3 TRACE MEMORY SAMPLING – TRSM(45) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-4 MESSAGE DISPLAY – MSG(46) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-5 LONG MESSAGE – LMSG(47) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-6 TERMINAL MODE – TERM(48) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-7 WATCHDOG TIMER REFRESH – WDT(94) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-8 I/O REFRESH – IORF(97) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-9 GROUP-2 HIGH-DENSITY I/O REFRESH – MPRF(61) . . . . . . . . . . . . . . . . . . . . . . . . 5-25-10 BIT COUNTER – BCNT(67) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-11 FRAME CHECKSUM – FCS(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-12 FAILURE POINT DETECTION – FPD(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-13 DATA SEARCH – SRCH(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-14 EXPANSION DM READ – XDMR(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-15 INDIRECT EM ADDRESSING – IEMS(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25-16 SELECT EM BANK – EMBC(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26 Network Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26-1 NETWORK SEND – SEND(90) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26-2 NETWORK RECEIVE – RECV(98) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26-3 About Network Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27 Serial Communications Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27-1 RECEIVE – RXD(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27-2 TRANSMIT – TXD(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27-3 CHANGE RS-232C SETUP – STUP(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27-4 PROTOCOL MACRO – PMCR(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28 Advanced I/O Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28-1 7-SEGMENT DISPLAY OUTPUT – 7SEG(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28-2 DIGITAL SWITCH INPUT – DSW(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28-3 HEXADECIMAL KEY INPUT – HKY(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28-4 TEN KEY INPUT – TKY(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28-5 MATRIX INPUT – MTR(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29 Special I/O Unit Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29-1 SPECIAL I/O UNIT READ – IORD(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29-2 SPECIAL I/O UNIT WRITE – IOWR(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-29-3 PCMCIA CARD MACRO – CMCR(––) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

257 257 258 259 261 263 266 277 277 278 279 280 281 281 281 282 285 286 287 289 292 295 295 304 304 305 306 307 308 309 310 310 311 312 312 314 318 319 320 321 322 322 327 331 333 333 335 337 339 340 340 343 347 350 352 354 354 355 357

137

Page 156

Data Areas, Definer Values, and Flags

5-1

Section 5-3

Notation In the remainder of this manual, all instructions will be referred to by their mnemonics. For example, the Output instruction will be called OUT; the AND Load instruction, AND LD. If you’re not sure of the instruction a mnemonic is used for, refer to Appendix B Programming Instructions. If an instruction is assigned a function code, it will be given in parentheses after the mnemonic. These function codes, which are 2-digit decimal numbers, are used to input most instructions into the CPU Unit and are described briefly below and in more detail in 4-7 Inputting, Modifying, and Checking the Program. A table of instructions listed in order of function codes, is also provided in Appendix B. An @ before a mnemonic indicates the differentiated version of that instruction. Differentiated instructions are explained in Section 5-4.

5-2

Instruction Format Most instructions have at least one or more operands associated with them. Operands indicate or provide the data on which an instruction is to be performed. These are sometimes input as the actual numeric values (i.e., as constants), but are usually the addresses of data area words or bits that contain the data to be used. A bit whose address is designated as an operand is called an operand bit; a word whose address is designated as an operand is called an operand word. In some instructions, the word address designated in an instruction indicates the first of multiple words containing the desired data. Each instruction requires one or more words in Program Memory. The first word is the instruction word, which specifies the instruction and contains any definers (described below) or operand bits required by the instruction. Other operands required by the instruction are contained in following words, one operand per word. Some instructions require up to four words. A definer is an operand associated with an instruction and contained in the same word as the instruction itself. These operands define the instruction rather than telling what data it is to use. Examples of definers are TC numbers, which are used in timer and counter instructions to create timers and counters, as well as jump numbers (which define which Jump instruction is paired with which Jump End instruction). Bit operands are also contained in the same word as the instruction itself, although these are not considered definers.

5-3

Data Areas, Definer Values, and Flags In this section, each instruction description includes its ladder diagram symbol, the data areas that can be used by its operands, and the values that can be used as definers. Details for the data areas are also specified by the operand names and the type of data required for each operand (i.e., word or bit and, for words, hexadecimal or BCD). Not all addresses in the specified data areas are necessarily allowed for an operand, e.g., if an operand requires two words, the last word in a data area cannot be designated as the first word of the operand because all words for a single operand must be within the same data area. Also, not all words in the SR and DM areas are writeable as operands (see Section 3 Memory Areas for details.) Other specific limitations are given in a Limitations subsection. Refer to Section 3 Memory Areas for addressing conventions and the addresses of flags and control bits.

138

Page 157

Section 5-3

Data Areas, Definer Values, and Flags ! Caution

The IR and SR areas are considered as separate data areas. If an operand has access to one area, it doesn’t necessarily mean that the same operand will have access to the other area. The border between the IR and SR areas can, however, be crossed for a single operand, i.e., the last bit in the IR area may be specified for an operand that requires more than one word as long as the SR area is also allowed for that operand. The Flags subsection lists flags that are affected by execution of an instruction. These flags include the following SR area flags. Abbreviation ER CY GR EQ LE N OF UF

Name Instruction Execution Error Flag Carry Flag Greater Than Flag Equals Flag Less Than Flag Negative Flag Overflow Flag Underflow Flag

Bit 25503 25504 25505 25506 25507 25402 25404 25405

ER is the flag most commonly used for monitoring an instruction’s execution. When ER goes ON, it indicates that an error has occurred in attempting to execute the current instruction. The Flags subsection of each instruction lists possible reasons for ER being ON. ER will turn ON if operands are not entered correctly. Instructions are not executed when ER is ON. A table of instructions and the flags they affect is provided in Appendix C Error and Arithmetic Flag Operation. Indirect Addressing

When the DM area is specified for an operand, an indirect address can be used. Indirect DM addressing is specified by placing an asterisk before the DM: When an indirect DM address is specified, the designated DM word will contain the address of the DM word that contains the data that will be used as the operand of the instruction. If, for example, 0001 was designated as the first operand and LR 00 as the second operand of MOV(21), the contents of DM 0001 was 1111, and DM 1111 contained 5555, the value 5555 would be moved to LR 00. MOV(21) 0001 LR 00

Indirect address

Word DM 0000 DM 0001 DM 0002

Content 4C59 1111 F35A

DM 1111 DM 1113 DM 1114

5555 2506 D541

Indicates DM 1111.

5555 moved to LR 00.

When using indirect addressing, the address of the desired word must be in BCD and it must specify a word within the DM area. In the above example, the content of 0000 would have to be in BCD between 0000 and 6655. The IEMS(––) instruction can be used to change the destination of from the DM area to one of the banks in the EM area. Refer to 5-25-15 INDIRECT EM ADDRESSING – IEMS(––) for details. Designating Constants

Although data area addresses are most often given as operands, many operands and all definers are input as constants. The available value range for a given definer or operand depends on the particular instruction that uses it. Constants must also be entered in the form required by the instruction, i.e., in BCD or in hexadecimal.

139

Page 158

Section 5-4

Differentiated Instructions

5-4

Differentiated Instructions Most instructions are provided in both differentiated and non-differentiated forms. Differentiated instructions are distinguished by an @ in front of the instruction mnemonic. A non-differentiated instruction is executed each time it is cycled as long as its execution condition is ON. A differentiated instruction is executed only once after its execution condition goes from OFF to ON. If the execution condition has not changed or has changed from ON to OFF since the last time the instruction was cycled, the instruction will not be executed. The following two examples show how this works with MOV(21) and @MOV(21), which are used to move the data in the address designated by the first operand to the address designated by the second operand. 00000 MOV(21) HR 10

Diagram A

DM 0000

Address

Instruction

00000 00001

LD MOV(21)

Operands 00000 HR DM

10 0000

00000

Diagram B

@MOV(21)

Address

Instruction

HR 10

00000 00001

LD @MOV(21)

DM 0000

Operands 00000 HR DM

10 0000

In diagram A, the non-differentiated MOV(21) will move the content of HR 10 to DM 0000 whenever it is cycled with 00000. If the cycle time is 80 ms and 00000 remains ON for 2.0 seconds, this move operation will be performed 25 times and only the last value moved to DM 0000 will be preserved there. In diagram B, the differentiated @MOV(21) will move the content of HR 10 to DM 0000 only once after 00000 goes ON. Even if 00000 remains ON for 2.0 seconds with the same 80 ms cycle time, the move operation will be executed only once during the first cycle in which 00000 has changed from OFF to ON. Because the content of HR 10 could very well change during the 2 seconds while 00000 is ON, the final content of DM 0000 after the 2 seconds could be different depending on whether MOV(21) or @MOV(21) was used. All operands, ladder diagram symbols, and other specifications for instructions are the same regardless of whether the differentiated or non-differentiated form of an instruction is used. When inputting, the same function codes are also used, but NOT is input after the function code to designate the differentiated form of an instruction. Most, but not all, instructions have differentiated forms. Refer to 5-10 INTERLOCK and INTERLOCK CLEAR – IL(02) and IL(03) for the effects of interlocks on differentiated instructions. The C200HX/HG/HE PCs also provide differentiation instructions: DIFU(13) and DIFD(14). DIFU(13) operates the same as a differentiated instruction, but is used to turn ON a bit for one cycle. DIFD(14) also turns ON a bit for one cycle, but does it when the execution condition has changed from ON to OFF. Refer to 5-9-2 DIFFERENTIATE UP and DOWN - DIFU(13) and DIFD(14) for details. Note Do not use SR 25313 and SR 25315 for differentiated instructions. These bits never change status and will not trigger differentiated instructions.

140

Page 159

Section 5-5

Expansion Instructions

5-5

Expansion Instructions The C200HX/HG/HE PCs have more instructions that require function codes (121) than function codes (100), so some instructions do not have fixed function codes. These instructions, called expansion instructions, are listed in the following table. Default function codes are given for the instructions that have them. An expansion instruction can be assigned one of 18 function codes using the Programming Console’s Expansion Instruction Function Code Assignments operation. The 18 function codes are: 17, 18, 19, 47, 48, 60 to 69, 87, 88, and 89. Refer to 7-2-14 Expansion Instruction Function Code Assignments for details on assigning function codes. Code

Mnemonic

Name

Page

17

(@)ASFT

ASYNCHRONOUS SHIFT REGISTER

178

18

(@)SCAN

CYCLE TIME

305

19

(@)MCMP

MULTI-WORD COMPARE

192

47

(@)LMSG

32-CHARACTER MESSAGE

308

48

(@)TERM

TERMINAL MODE

309

60

CMPL

DOUBLE COMPARE

196

61

(@)MPRF

GROUP-2 HIGH-DENSITY I/O REFRESH

311

62

(@)XFRB

TRANSFER BITS

189

63

(@)LINE

COLUMN TO LINE

224

64

(@)COLM

LINE TO COLUMN

225

65

(@)SEC

HOURS TO SECONDS

207

66

(@)HMS

SECONDS TO HOURS

208

67

(@)BCNT

BIT COUNTER

312

68

(@)BCMP

BLOCK COMPARE

197

69

(@)APR

ARITHMETIC PROCESS

263

87

TTIM

TOTALIZING TIMER

165

88

ZCP

AREA RANGE COMPARE

200

89

(@)INT

INTERRUPT CONTROL

289

---

7SEG

7-SEGMENT DISPLAY OUTPUT

340

---

(@)ADBL

DOUBLE BINARY ADD

249

---

AVG

AVERAGE VALUE

259

---

(@)BXF2

EM BANK TRANSFER

191

---

CPS

SIGNED BINARY COMPARE

202

---

CPSL

DOUBLE SIGNED BINARY COMPARE

203

---

CMCR

PCMCIA CARD MACRO

357

---

(@)DBS

SIGNED BINARY DIVIDE

255

---

(@)DBSL

DOUBLE SIGNED BINARY DIVIDE

256

---

DSW

DIGITAL SWITCH INPUT

343

---

@EMBC

SELECT EM BANK

321

---

(@)FCS

FCS CALCULATE

312

---

FPD

FAILURE POINT DETECT

314

---

(@)HEX

ASCII-TO-HEXADECIMAL

219

---

HKY

HEXADECIMAL KEY INPUT

347

---

(@)IEMS

INDIRECT EM ADDRESSING

320

---

(@)IORD

SPECIAL I/O UNIT READ

354

---

(@)IOWR

SPECIAL I/O UNIT WRITE

355

---

(@)MAX

FIND MAXIMUM

257

---

(@)MBS

SIGNED BINARY MULTIPLY

253

---

(@)MBSL

DOUBLE SIGNED BINARY MULTIPLY

254

141

Page 160

Section 5-6

Coding Right-hand Instructions Code

5-6

Mnemonic

Name

Page

---

(@)MIN

FIND MINIMUM

258

---

MTR

MATRIX INPUT

352

---

(@)NEG

2’S COMPLEMENT

226

---

(@)NEGL

DOUBLE 2’S COMPLEMENT

227

---

PID

PID CONTROL

266

---

(@)PMCR

PROTOCOL MACRO

339

---

(@)RXD

RECEIVE

333

---

(@)SBBL

DOUBLE BINARY SUBTRACT

251

---

(@)SCL

SCALING

222

---

(@)SRCH

DATA SEARCH

318

---

(@)STUP

CHANGE RS-232C SETUP

337

---

(@)SUM

SUM CALCULATE

261

---

(@)TKY

TEN KEY INPUT

350

---

(@)TXD

TRANSMIT

335

---

(@)XDMR

EXPANSION DM READ

319

---

(@)XFR2

EM BLOCK TRANSFER

190

---

ZCPL

DOUBLE AREA RANGE COMPARE

201

Coding Right-hand Instructions Writing mnemonic code for ladder instructions is described in Section 4 Writing and Inputting the Program. Converting the information in the ladder diagram symbol for all other instructions follows the same pattern, as described below, and is not specified for each instruction individually. The first word of any instruction defines the instruction and provides any definers. If the instruction requires only a signal bit operand with no definer, the bit operand is also placed on the same line as the mnemonic. All other operands are placed on lines after the instruction line, one operand per line and in the same order as they appear in the ladder symbol for the instruction. The address and instruction columns of the mnemonic code table are filled in for the instruction word only. For all other lines, the left two columns are left blank. If the instruction requires no definer or bit operand, the data column is left blank for first line. It is a good idea to cross through any blank data column spaces (for all instruction words that do not require data) so that the data column can be quickly scanned to see if any addresses have been left out. If an IR or SR address is used in the data column, the left side of the column is left blank. If any other data area is used, the data area abbreviation is placed on the left side and the address is place on the right side. If a constant to be input, the number symbol (#) is placed on the left side of the data column and the number to be input is placed on the right side. Any numbers input as definers in the instruction word do not require the number symbol on the right side. TC bits, once defined as a timer or counter, take a TIM (timer) or CNT (counter) prefix. When coding an instruction that has a function code, be sure to write in the function code, which will be necessary when inputting the instruction via the Programming Console. Also be sure to designate the differentiated instruction with the @ symbol.

142

Page 161

Section 5-6

Coding Right-hand Instructions

The following diagram and corresponding mnemonic code illustrates the points described above. 00000

Address Instruction

00001 DIFU(13) 22500 00002

00100

00200

22500 BCNT(67)

01001 01002

LR 6300

Data

00000

LD

00000

00001

AND

00001

00002

OR

00002

00003

DIFU(13)

22500

00004

LD

00100

00005

AND NOT

00200

00006

LD

01001

00007

AND NOT

01002

00008

AND NOT

00009

OR LD

00010

AND

00011

BCNT(67)

#0001 004 HR 00

00005 TIM 000

LR

6300 –– 22500

#0150 TIM 000

–– #

MOV(21)

0001 004

HR 00

HR

LR 00

HR 0015

00012

LD

00013

TIM

00500

00014

LD

00015

MOV(21)

00016

LD

00017

OUT NOT

00 00005 000

#

0150

TIM

000 ––

HR

00

LR

00

HR

0015 00500

143

Page 162

Section 5-6

Coding Right-hand Instructions Multiple Instruction Lines

00000

If a right-hand instruction requires multiple instruction lines (such as KEEP(11)), all of the lines for the instruction are entered before the right-hand instruction. Each of the lines for the instruction is coded, starting with LD or LD NOT, to form ‘logic blocks’ that are combined by the right-hand instruction. An example of this for SFT(10) is shown below. Address Instruction

00001

I SFT(10)

00002

P HR 00

00100

00200

01001 01002

22500

R

HR 00

00500

144

LD

00000

00001

AND

00001

00002

LD

00002

00003

LD

00100

00004

AND NOT

00200

00005

LD

01001

00006

AND NOT

00007

AND NOT

00008

OR LD

00009

AND

00010

SFT(10)

LR 6300

HR 0015

END(01)

Data

00000

00011

LD

00012

OUT NOT

01002 LR

6300 –– 22500 ––

HR

00

HR

00

HR

0015 00500

When you have finished coding the program, make sure you have placed END(01) at the last address.

Page 163

Section 5-7

Instruction Set Lists

5-7

Instruction Set Lists This section provides tables of the instructions available in the C200HX/HG/HE. The first table can be used to find instructions by function code. The second table can be used to find instruction by mnemonic. In both tables, the @ symbol indicates instructions with differentiated variations. Note Refer to 5-5 Expansion Instructions for a list of the expansion instructions.

5-7-1 Function Codes The following table lists the instructions that have fixed function codes. Each instruction is listed by mnemonic and by instruction name. Use the numbers in the leftmost column as the left digit and the number in the column heading as the right digit of the function code. Right digit

Left digit

2

3

5

6

7

8

0

NOP NO OPERATION

0 END END

1

IL INTERLOCK

ILC INTERLOCK CLEAR

JMP JUMP

4

JME JUMP END

(@) FAL FAILURE ALARM AND RESET

FALS SEVERE FAILURE ALARM

STEP STEP DEFINE

SNXT STEP START

9

1

SFT SHIFT REGISTER

KEEP KEEP

CNTR REVERSIBLE COUNTER

DIFU DIFFERENTIATE UP

DIFD DIFFERENTIATE DOWN

TIMH HIGHSPEED TIMER

(@) WSFT WORD SHIFT

(@) ASFT ASYNCHRONOUS SHIFT REGISTER

(@) SCAN CYCLE TIME

(@) MCMP MULTIWORD COMPARE

2

CMP COMPARE

(@) MOV MOVE

(@) MVN MOVE NOT

(@) BIN BCD TO BINARY

(@) BCD BINARY TO BCD

(@) ASL SHIFT LEFT

(@) ASR SHIFT RIGHT

(@) ROL ROTATE LEFT

(@) ROR ROTATE RIGHT

(@) COM COMPLEMENT

3

(@) ADD BCD ADD

(@) SUB BCD SUBTRACT

(@) MUL BCD MULTIPLY

(@) DIV BCD DIVIDE

(@) ANDW LOGICAL AND

(@) ORW LOGICAL OR

(@) XORW EXCLUSIVE OR

(@) XNRW EXCLUSIVE NOR

(@) INC INCREMENT

(@) DEC DECREMENT

4

(@) STC SET CARRY

(@) CLC CLEAR CARRY

---

---

---

TRSM TRACE MEMORY SAMPLE

(@) MSG MESSAGE DISPLAY

(@) LMSG LONG MESSAGE

(@) TERM TERMINAL MODE

---

5

(@) ADB BINARY ADD

(@) SBB BINARY SUBTRACT

(@) MLB BINARY MULTIPLY

(@) DVB BINARY DIVIDE

(@) ADDL DOUBLE BCD ADD

(@) SUBL DOUBLE BCD SUBTRACT

(@) MULL DOUBLE BCD MULTIPLY

(@) DIVL DOUBLE BCD DIVIDE

(@) BINL DOUBLE BCD-TODOUBLE BINARY

(@) BCDL DOUBLE BINARY-TODOUBLE BCD

6

CMPL DOUBLE COMPARE

(@) MPRF GROUP-2 HIGH-DENSITY I/O REFRESH

(@) XFRB TRANSFER BITS

(@) LINE COLUMN TO LINE

(@) COLM LINE TO COLUMN

(@) SEC HOURS-TOSECONDS

(@) HMS SECONDSTO-HOURS

(@) BCNT BIT COUNTER

(@) BCMP BLOCK COMPARE

(@) APR ARITHMETIC PROCESS

7

(@) XFER BLOCK TRANSFER

(@) BSET BLOCK SET

(@) ROOT SQUARE ROOT

(@) XCHG DATA EXCHANGE

(@) SLD ONE DIGIT SHIFT LEFT

(@) SRD ONE DIGIT SHIFT RIGHT

(@) MLPX 4-TO-16/ 8-TO-256 DECODER

(@) DMPX 16-TO-4/ 256-TO-8 ENCODER

(@) SDEC 7-SEGMENT DECODER

(@) FDIV FLOATING POINT DIVIDE

8

(@) DIST SINGLE WORD DISTRIBUTE

(@) COLL DATA COLLECT

(@) MOVB MOVE BIT

(@) MOVD MOVE DIGIT

(@) SFTR REVERSIBLE SHIFT REGISTER

(@) TCMP TABLE COMPARE

(@) ASC ASCII CONVERT

TTIM TOTALIZING COUNTER

ZCP AREA RANGE COMPARE

(@) INT INTERRUPT CONTROL

9

(@) SEND NETWORK SEND

(@) SBS SUBROUTINE ENTRY

SBN SUBROUTINE DEFINE

RET SUBROUTINE RETURN

(@) WDT WATCHDOG TIMER REFRESH

---

---

(@) IORF I/O REFRESH

(@) RECV NETWORK RECEIVE

(@) MCRO MACRO

5-7-2 Alphabetic List by Mnemonic Mnemonic

Code

Words

Name

Page

7SEG

––

4

7-SEGMENT DISPLAY OUTPUT

340

ADB (@)

50

4

BINARY ADD

243

ADBL (@)

––

4

DOUBLE BINARY ADD

249

ADD (@)

30

4

BCD ADD

229

ADDL (@)

54

4

DOUBLE BCD ADD

230

AND

None

1

AND

149

AND LD

None

1

AND LOAD

150

AND NOT

None

1

AND NOT

149

ANDW (@)

34

4

LOGICAL AND

278

APR (@)

69

4

ARITHMETIC PROCESS

263

ASC (@)

86

4

ASCII CONVERT

218

145