Page 164

Glossary protocol

The parameters and procedures that are standardized to enable two devices to communicate or to enable a programmer or operator to communicate with a device.

Rack

An assembly of various Units on a Backplane that forms a functional unit in a building-block PC System. Racks include CPU Racks, Expansion I/O Racks, I/O Racks, and Slave Racks.

read word

A word in the LR area that contains data transferred from another PC in a PC Link System. A read word cannot be written to by the PC.

refresh

The process of updating output status sent to external devices so that it agrees with the status of output bits held in memory and of updating input bits in memory so that they agree with the status of inputs from external devices.

relay-based control

The forerunner of PCs. In relay-based control, groups of relays are wired to each other to form control circuits. In a PC, these are replaced by programmable circuits.

reserved bit

A bit that is not available for user application.

reserved word

A word in memory that is reserved for a special purpose and cannot be accessed by the user.

Restart Bit

A bit used to restart a Unit mounted to a PC.

rightmost (bit/word)

The lowest numbered bits of a group of bits, generally of an entire word, or the lowest numbered words of a group of words. These bits/words are often called least-significant bits/words.

rising edge

The point where a signal actually changes from an OFF to an ON status.

RS-232C interface

An industry standard for serial communications.

RS-422 interface

An industry standard for serial communications.

RTS signal

Request To Send: the BASIC Unit can be programmed to assert this signal when it wishes to send data through a communications port.

RUN mode

The operating mode used by the PC for normal control operations.

self diagnosis

A process whereby the system checks its own operation and generates a warning or error if an abnormality is discovered.

serial polling

A polling method in which each device being polled is polled one at a time in sequence.

series

A wiring method in which Units are wired consecutively in a string. In Link Systems wired through Link Adapters, the Units are still functionally wired in series, even though Units are placed on branch lines.

Single-level PC Link System

A PC Link System in which there is no PC with more than one PC Link Unit.

Single-link PC Link System

A PC Link System that connects only two PCs to each other.

Single-level SYSMAC LINK System

A SYSMAC LINK System in which there is no PC with more than one SYSMAC LINK Unit.

150

Page 165

Glossary slot

A position on a Rack (Backplane) to which a Unit can be mounted.

Special I/O Unit

A dedicated Unit that is designed for a specific purpose. Special I/O Units include Position Control Units, High-Speed Counter Units, Analog I/O Units, etc.

switching capacity

The voltage/current that a relay can switch on and off.

SYSMAC LINK Network

All the PCs connected in series via SYSMAC LINK Units that can join together to form data links or read and write data back and forth.

SYSMAC LINK System

A Link System that contains two or more SYSMAC LINK Networks.

SYSMAC/NET Link Read/Write Instructions

Programming instructions used to transfer data between PC connected in a SYSMAC LINK Network or NET Link Subsystem. The write instruction acronym is SEND(90) and is used to transfer data to another PC. The read instruction acronym is RECV(98) and is used to receive data from another PC.

system configuration

The arrangement in which Units in a System are connected.

system error

An error generated by the system, as opposed to one resulting from execution of an instruction designed to generate an error.

system error message

An error message generated by the system, as opposed to one resulting from execution of an instruction designed to generate a message.

terminator

The code comprising an asterisk and a carriage return (* CR) which indicates the end of a block of data in communications between devices. Frames within a multi-frame block are separated by delimiters. Also a Unit in a Link System designated as the last Unit on the communications line.

transmission distance

The distance that a signal can be transmitted.

Unit

In OMRON PC terminology, the word Unit is capitalized to indicate any product sold for a PC System. Though most of the names of these products end with the word Unit, not all do, e.g., a Remote Terminal is referred to in a collective sense as a Unit. Context generally makes any limitations of this word clear.

unit number

A number assigned to some Link Units and Special I/O Units to assign words and sometimes other operating parameters to it.

user program

A program written by the user as opposed to programs provided with a product.

watchdog timer

A timer within the system that ensures that the cycle time stays within specified limits. When limits are reached, either warnings are given or PC operation is stopped depending on the particular limit that is reached.

WDT

See watchdog timer.

wire communications

A communications method in which signals are sent over wire cable. Although noise resistance and transmission distance can sometimes be a problem with wire communications, they are still the cheapest and the most common, and perfectly adequate for many applications.

151

Page 166

Glossary word

A unit of data storage in memory that consists of 16 bits. All data areas consists of words. Some data areas can be accessed only by words; others, by either words or bits.

word address

The location in memory where a word of data is stored. A word address must specify (sometimes by default) the data area and the number of the word that is being addressed.

word allocation

The process of assigning I/O words and bits in memory to I/O Units and terminals in a PC System to create an I/O Table.

work bit

A bit in a work word.

work word

A word that can be used for data calculation or other manipulation in programming, e.g., LR words not used in a PC Link or NET Link System.

write word

A word written in the LR area by a PC in a PC Link System. The data of the write words is transferred to the rest of the PCs that share common data areas, i.e., the write words for one PC are read words for the rest of the PCs in the PC Link System.

152

Page 167

Index A-B applications, precautions, xiii AR Area reading, 90, 91 writing, 90 automatic generation of data link tables, 46 Auxiliary Power Supply Unit, 20 bits, controlling cancelling forced-set and forced-reset bits, 102 force-setting and force-resetting bits, 101 broadcast test, 110, 115 Bus Connector, 25 bypass, failed node bypass function, 116

C cables Auxiliary Power Supply Unit, 22 connecting transmission cables, 26 characteristics, data link, 63 CIO Area, reading, 90, 91 clock reading CV-series clock, 97 setting CV-series clock, 97 coaxial cable. See cables command set BROADCAST TEST DATA SEND, 110 BROADCAST TEST RESULTS READ, 110 CLOCK READ, 97 CLOCK WRITE, 97 CONTROLLER DATA READ, 95, 104 CONTROLLER STATUS READ, 95, 105 DATA LINK START, 103 DATA LINK STATUS READ, 108 ERROR CLEAR, 98 FILE MEMORY BLOCK READ, 99 FILE MEMORY BLOCK WRITE, 100 FILE MEMORY INDEX READ, 98 FORCED SET/RESET, 101 FORCED SET/RESET CANCEL, 102 HALT DATA LINK, 103 INTERNODE ECHO TEST, 109 MEMORY AREA READ, 90, 102 MEMORY AREA WRITE, 90 MULTIPLE MEMORY AREA READ, 91 NETWORK STATUS READ, 107 PROGRAM AREA READ, 92 PROGRAM AREA WRITE, 93 RESET, 104 RUN, 94 STOP, 94 memory area code, 89 PCs, 90–103 list, 87 response codes, 88 response format, 86 SYSMAC LINK Units, 103–110 list, 87 common link parameters, 48

CVSS, 112 communications specifications, 137 testing broadcast test, 110, 115 internode echo test, 109, 113 token bus, 36 cycle time, data link refreshing, 37 data areas. See Memory Areas

Communications Boards, 20, 25 data exchange timing, 65 communications cycle, 36 data link, 44 activating, 45, 58 characteristics, 63 combining SYSMAC LINK Units, 55 common link parameters, 48 communications cycle time, 63 controlling, 58 creating, 45 data exchange timing, 65 data link area, definition, 44 Data Link Status Flag, 60 data link table generation automatic, 62 manual, 62 errors, 122 example, 55 halting, 58, 103 I/O response time, 66 communications cycle time, 40 data link, 63 compatibility, 6 completion status. See end codes counters changing PV, 90 reading Completion Flag forced status, 102 reading Completion Flag status, 90, 91 reading PV, 90, 91 CV-mode commands errors, 119 response codes, errors, 119 CV-mode commands command format, 86

D

153

Page 168

Index precautions, 59 reading, 77 reading data link status, 108 refresh parameters, 50 refreshing, 47 start-up node, 36 starting, 103 status flags, 60 table back-up, 50 tables automatic generation, 46 definition, 44 examples, 51 manual generation, 48 troubleshooting, 125 write, 76 data links, refresh cycle time, 37 data read/write services, 74 data transfer area, 75

H-I handling precautions, 130 Host Link Units, compatibility with SYSMAC LINK Units, 6 I/O response time, in data links, 66 indicators, 13 Auxiliary Power Supply Unit, 22 data link, 45 error indications, 118 indirect addressing, 77, 78 example, 82 inspection, 130 tools and equipment needed, 130 installation, 17, 22 precautions, xiii instruction set, PC RECV(98), 77 SEND(90), 76 internode echo test, 109, 113 delay times, 84 dimensions, 33 DM Area reading, 90, 91 writing, 90

L-M LED indicator. See indicators Link Units, compatibility, 6 manual generation of data link tables, 48 maximum node number, 40

E-F errors clearing CV-series PC errors, 98 CV-mode commands, 119 data link, 122 data link table, 122 LED indications, 118 other, 122 SEND (90)/RECV (98), 119 failed node, bypassing, 116 file memory reading the contents of, 99 writing the contents of, 100 maximum number of frames, 40 memory area code, 89 Memory Areas designating addresses, 88 reading, 90, 91 reading forced contents, 102 writing, 90 model numbers reading PC model number, 95 reading SYSMAC LINK Unit model number, 104 monitoring, remote, 112 mounting, 18

N-O files, reading indices of blocks stored in file memory, 98

NET Link Units, compatibility with SYSMAC LINK Units, 6

FINS commands. See CV-mode commands network other OMRON network systems, 2 reading network status, 107 troubleshooting, 124 flags Active Node Flags, 42 Communication Controller Error Flag, 42 Communications Error, 62, 63 Data Link Status, 62, 63 EEPROM Error Flag, 42 PC Fatal Error, 62, 63 PC Mode, 62, 63 RECV(98), Enable and Error Flags, 80 SEND(90), Enable and Error Flags, 80 frames, maximum number, 40

154 network parameters, 37, 131 conflicting, 41 initializing, 41 setting, 40 number of polled units, 40 operating environment, precautions, xiii operating level, 7, 38 optical fiber cable. See cables

Page 169

Index

P PC changing to PROGRAM mode, 94 changing to RUN mode, 94 compatible CPUs, 6 PC memory address. See Memory Areas reading CV-series PC status, 95 reading various CV-series PC data, 95 example, 80 processing, 80 specifications, 137 Auxiliary Power Supply Unit, 20 standard models, 133 start-up node, definition, 36 status, data link, 60 polling unit, 4 backup, 115 definition, 36 setting, 39 switches, 14 DIP switch 1 accessing, 14 location on C1000H–SLK11/SLK21–V1, 10 location on C200HW–SLK13/14/23/24, 12 DIP switch 2, location on C200HW–SLK13/14/23/24, 12 node number, 14, 15 setting, 37 polling unit, 39 reset switch, 10 setting, 15 precautions, xi applications, xiii general, xii handling, 130 interchanging SYSMAC LINK Units, 130 operating environment, xiii safety, xii

SYSMAC LINK System communications, 36 features, 3 multilevel, 5 number of PCs, 4 single-level system, 4 system configuration, 4 program reading contents of program area words, 92 writing to program area words, 93

SYSMAC LINK Unit components C1000H–SLK11/SLK21–V1, 10 C200HW–SLK13/14/23/24, 12 dimensions, 33 interchanging, 130 reading various Unit data, 104 replacing, 131

PC Link Units, compatibility with SYSMAC LINK Units, 6 PC mode, at start-up, 38 polled units, number, 40 polling cycle, definition, 36 programming, remote, 112

R

SYSMAC LINK Units, combining, 55

RAS, 113 RECV (98), 77 delay time, 85 errors, 119 example, 80 processing, 80 refresh cycle time, 37 refresh of data link area, 47 remote monitoring, 112 remote programming, 112 resetting, SYSMAC LINK Unit, 104 response codes for CV-mode commands, 88 for SEND(90) and RECV(98), 79 response time. See I/O response time

T-W test, 115 broadcast, 110, 115 internode echo, 109, 113 timers changing PV, 90 reading Completion Flag forced status, 102 reading Completion Flag status, 90, 91 reading PV, 90, 91 timing data exchange, 65 SEND(90) and RECV(98), 80 token, definition, 36 token bus communications, definition, 36 token cycle, definition, 36

S safety precautions. See precautions SEND (90), 76 delay time, 84 errors, 119 transmission cycle time changing, 65 definition, 37 troubleshooting, 124 wiring, 22 write, 76

155

Page 170

This page is a scan with no text; see it in the PDF.

Page 171

Revision History

A manual revision code appears as a suffix to the catalog number on the front cover of the manual.

Cat. No. W174-E1-07 Revision code

The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code

Date

1

August 1990

Original production

Revised content

2

July 1992

Major rewrite for new version of product.

2A

November 1992

3

August 1994

Information on CV-mode commands and SYSMAC LINK Units using optical fiber cable was added. Page 22: Diagram and note at bottom of page corrected. C200H-SLK11 and C200H-SLK21-V1 have been upgraded to C200HS-SLK12 and C200HS-SLK22. Backplane model numbers updated. Scan time changed to cycle time throughout the manual. Pages 2, 3, 38, 43, 44, 46, 50, 51, 53, 57, 58, 64, 98, 101, 109: “Host computer” changed to “CVSS” when related to the SYSMAC LINK. Pages 2, 3, 4, 47, 49, 98: “LSS” changed to “FIT” when related to the SYSMAC LINK. Pages 4, 5, 24, 25, 104, 109, 110, 111, 112, and 117: Terms unified to “Terminator” and “F Adapter.” Page 5: “Compatibility with other PCs” updated. Pages 6, 7: “Compatibility with other Link Units” updated. Page 22: C200H Power Supply Unit information was corrected. Page 24: Model number correction. C200H-TL001 Attachment Stirrup added. Page 25: C200H-TL001 Attachment Stirrup added. Pages 31, 32: Models changed to C200H-SLK11 and C200H-SLK21-V1. C200H-TL001 Attachment Stirrup added. Page 34: Second paragraph of “Start-up Node” was rewritten. Page 39: Text added to Setting Network Parameters. Page 44: DM area information corrected in the top table. Pages 44, 48: CV Series added to the “Max. number of linked words (in Network)” in the table. Page 46: Sentence was added to the bottom of the page. Pages 46, 49: “Software” changed to “CVSS.” Page 49: Note added. Page 59: Data Exchange timing diagram corrected. Pages 60 to 62: Minimum and maximum response time diagrams and descriptions corrected. Two cases added. Page 64: An addition about the SYSMAC LINK Support Board in Computer Transmission. Page 65: Data transfer area information added. Page 66: Note 4 added. Page 67: Note 3 added. Page 69: Indirect Addressing example added. Page 73: List to CV-mode commands for PCs corrected. Page 80: Parameters for RUN corrected. Page 98: C200H-IP006 Peripheral Interface Unit added to Peripheral Device Connection. LSS and CVSS information added. Pages 101, 102: Model number change. Page 102: Caution has been added. Page 114: A precaution on interchanging SYSMAC LINK Units added. Page 121: Weight and notes added to the table. 3A

October 1994

Page 110: Information of support software capabilities corrected (6 locations).

4

August 1996

New version of manual for C200HX/HG/HE. All references to FIT have been removed or replaced with references to SSS. Section of precautions added before section 1 and adjustments made to signal words for precautions. Page 16: Pin functions of pin 82 of the top table and 42 of the bottom table have been corrected.

5

January 1998

Pages 6, 20, 129, 130: “C200HW-COM04” changed to “C200HW-COM04-EV1.” Pages 7, 8, 19, 38: PC Card Unit information for C200HX/HG/HE PCs added. Page 25: C200HW-CE012 Bus Connector and Communications Board information added. Page 129: C200HW-CE012 Bus Connector added to the list in Related Items.

157

Page 172

Revision History Revision code

Date

6

March 2000

Revised content Updated the Precautions. Page 60: Added information on data link status, including table describing flag operation and programming examples. Page 110: Added comment that remote programming or monitoring of CVM1 and CV-series PCs is not possible. Page 116: Changed description of ERC indicator. Page 121: Changed description of Communications Controller error. Page 133: Changed description of send/receive buffer capacity.

07

September 2003

Page xiii: “Power Supply Units” added in one place. Page 28: Model numbers changed in several places. Page 29: Changes made to table and another table added. Page 41: Information on conflicting network parameters changed. Page 67: Numerical changes made in three places. Page 75: Information on NETWORK READ/WRITE instructions changed. Page 91: Line added at bottom of page. Page 134: Model numbers changed in several places in table at bottom of page and note added.

158

Page 173

This page is a scan with no text; see it in the PDF.