For the Omron C28P

Page 180

Appendix C

Programming Console Operations Monitoring and Data Changing Operations Operation/Description

Modes*

Bit/Word Monitor Up to six memory addresses, with either words or bits, or a combination of the two, can be monitored at once. Only three, however, can be displayed at any one time. If operated in RUN or MONITOR Mode, the status of monitored bits will also be displayed. The operation can be started from a cleared display by entering the address of the first word or bit to be monitored and pressing MONTR, or from any address in the program by displaying the address of the bit or word to be monitored and pressing MONTR.

RPM

Key sequence

CLR

SHIFT

CONT

[Address]

# LR

SHIFT

SHIFT

LD

OUT

(Monitor Clear)

TIM

DM

3-word Monitor RPM Monitors three consecutive words simultaneously. Specify the lowest valued address of the htree words, press MONTR, and then press EXT to display the data contents of the specified word and the two words that follow. Pressing CLR will change the three-word monitor operation into a single-word display.

174

HR

CLR

CNT

Force Set/Reset If a bit, timer, or counter address is leftmost on the screen during a bit/word monitor operation, pressing PLAY/SET will turn ON the bit, start the timer, or increment the counter. Pressing REC/RESET will turn OFF the bit, or reset the timer or counter. Timers will not operate in PROGRAM mode. SR bits are not affected by this operation.

MONTR

HR

PM

Bit/Hex monitor in progress

Bit/Hex monitor in progress

EXT

PLAY SET

REC RESET

Page 181

Appendix C

Programming Console Operations Operation/Description

Modes*

Hex/BCD Data Change PM Used to edit the leftmost BCD or hexadecimal value displayed during a Bit/Word Monitor operation. If a timer or counter is leftmost on the display, the PV will be the value displayed and affected by this operation. It can only be changed in MONITOR mode and only while the timer or counter is operating. SR words cannot be changed using this operation. Binary Data Change PM This operation is used to change the value of 16-bit IR, HR, AR, LR, or DM words bit-by-bit. The cursor can be moved left by using the up key, and right using the down key. The position of the cursor is the bit that will be overwritten. There are two types of changes, tem-porary and permanent. Temporary changes result if 1 or 0 is entered. Permanent changes are made by pressing SHIFT and SET, or SHIFT and RESET. (These are only avail-able on the C200H PC.) The former will result in an S being displayed in that bit position. Similarly, SHIFT and RESET will produce an R in the dis-play. During operation of the PC, the bits having 1 or 0 values will change according to the conditions. Bits with S or R will, however, always be treated as a 1 or 0, respectively. NOT cancels S and R settings and the bits will become 1 or 0, respectively. Pressing WRITE transfers the changes made on the display to the memory.

SV Change, PM SV Reset M There are two ways of modifying the SVs for timers and counters. One method is to enter a new value. The other is to increment or decrement the existing SV. In MONITOR mode the SV can be changed while the program is being executed. Incrementing and decrementing can only be carried out if the SV has been entered as a constant.

Key sequence Bit/Hex monitor in progress

Binary monitor in progress

[New Data]

CHG

WRITE

WRITE

CHG

B

1 A

0 PLAY

SHIFT

SET REC

SHIFT

RESET

NOT

Timer/Counter currently displayed

CHG

EXT

[New SV]

WRITE

*Modes in which the given instruction is applicable: R = RUN, M = MONITOR, P = PROGRAM

175

Page 182

Appendix C

Programming Console Operations Operation/Description

3-word Change This operation changes the value of a word displayed during a 3-word monitor operation. The blinking cursor indicates the word that will be affected by the operation. The cursor can be moved by using the up and down keys. When the cursor is at the desired location, press CHG. After entering the new data, pressing WRITE causes the original data to be overwritten.

Modes*

PM 3-word Monitor in progress

Scan Time Display RM This operation should be performed after all syntax errors have been corrected. The scan time can only be checked in RUN or MONITOR mode and while the program is being executed. The scan time displayed after pressing CLR and MONTR is that for the current scan. Pressing MONTR again will display a new scan time. The difference between the displayed scan times is due to the different execution conditions that exist during each scan. Hex–ASCII Display Change Converts 4-digit hexadecimal DM data to ASCII and vice-versa.

Key sequence

CLR

MONTR

CHG

[Data]

WRITE

MONTR

RPM Word currently displayed

TR

Binary Monitor RPM The contents of a monitored word can be specified to be displayed in binary by pressing SHIFT and MONTR after entering the word address. Words can be scrolled by pressing the up and down keys to increment and decrement the displayed address. To terminate the binary display, press CLR.

[Word Address]

Binary monitor clear All monitor clear

176

Page 183

Appendix C

Programming Console Operations Operation/Description

Program Read Protect/Clear

Modes*

Key sequence

RPM [Mode changed]

REC

[4–digit number]

WRITE

Cleared

RESET PLAY SET

Clear Forced Set/Reset Simultaneously clears all forced bits within the word currently displayed.

PM

PLAY

REC

SET

RESET

CLR

WRITE

Protected

NOT

*Modes in which the given instruction is applicable: R = RUN, M = MONITOR, P = PROGRAM

177

Page 184

Appendix C

Programming Console Operations Cassette Tape Operations Operation/Description

Modes*

Program Memory Save P This operation copies data from the Program Memory to tape. The file no. refers to an identifying address for the information within the tape. For ease of information retrieval, the file number and data information should be written clearly on the tape. File numbers should not be used more than once on one tape. If only a part of the Program Memory is to be stored, the appropriate start and stop addresses must be entered. Due to limited memory capacity, each C60 tape can only store apporximately 16K words on each side of the tape. When the start address is entered, the maximum stop address is set as the default. Do not set a stop address past this one. If you wish to record past this address the additional information will need to be recorded either on the flip side of the tape or on a separate tape. After starting the tape recorder, wait about 5 seconds before pressing REC/RESET to allow the leader tape to pass before the data transmission starts. Program Memory Restore To read Program Memory data which has been recorded on a cassette tape, the keystrokes are as given here. The file no. should be the same as the one entered when the data was recorded. The read operation will proceed from the specified start address up to the end of the tape, unless halted by a CLR command. The instruction must be completed before the leader tape has been played, i.e., before the data is reached on the tape.

P

Program Memory Compare The procedure to compare Program Memory data on a tape with the Program Memory in the Program Memory area is the same as that for reading it (see above), except that after starting the tape playback, VER should be pressed instead of SHIFT and PLAY/SET.

P

178

Key sequence A CLR

0

EXT

[Stop address]

WRITE

[File no.]

WRITE

Start recording with the tape recorder.

[Start address]

SHIFT

REC RESET

After about 5 seconds (Cancel with the CLR key.)

A CLR

0

EXT

[File no.]

WRITE

Start tape recorder playback.

[Start address]

SHIFT

PLAY SET

Within about 5 seconds

A CLR

EXT

0

[File no.]

WRITE

Start tape recorder playback.

[Start address]

VER

Within about 5 seconds

Page 185

Appendix C

Programming Console Operations Operation/Description

DM Data Save, Restore, Compare The procedures for transferring DM area data to and from tape, and for comparing it, are basically the same as for the Program Memory, given above. The exceptions are that start and stop addresses are not required, and the DM area is specified instead of the Program Memory. Each operation will continue through to the end of the tape unless cancelled by pressing clear.

Modes*

Key sequence

P EXT

CLR

5 second leader tape

B

1

[File no.]

Start tape recorder recording.

SHIFT

Start tape recorder playback.

SHIFT

REC RESET PLAY SET

VER

PROM Writer Operations Operation/Description

Modes*

PC to PROM Writer Outputs Program Memory to the RS–232C interface for writing to a commercial PROM writer.

P

PROM Writer to PC Read Program Memory data from a commercial PROM writer into the PC via the RS–232C interface.

P

Key sequence Start PROM writer reception

Start PROM writer transmission

*Modes in which the given instruction is applicable: R = RUN, M = MONITOR, P = PROGRAM

179

Page 186

Appendix D Error and Arithmetic Flag Operation The following table shows which instructions affect the ER, CY, GT, LT and EQ flags. In general, ER indicates that operand data is not within requirements. CY indicates arithmetic or data shift results. GT indicates that a compared value is larger than some standard, LT that it is smaller; and EQ, that it is the same. EQ also indicates a result of zero for arithmetic operations. Refer to subsections of Section 5 Instruction Set for details. Vertical arrows in the table indicate the flags that are turned ON and OFF according to the result of the instruction. Although TIM, CNT, and CNTR are executed when ER is ON, other instructions with a vertical arrow under the Er column are not executed if ER is ON. All of the other flags in the following table will also not operate when ER is ON. Instructions not shown do not affect any of the flags in the table. Instructions END(01)

SR 1907 (LE) OFF

SR 1906 (EQ) OFF

SR 1905 (GR) OFF

SR 1904 (CY)

SR 1903 (ER)

OFF

OFF

STC(40)

ON

ON

CLC(41)

OFF

OFF

TIM TIMH(15) CNT CNTR(12) WSFT(16) CMP(20) MOV(21) MVN(22) BIN(23) BCD(24) ADD(30) SUB(31) MUL(32) DIV(33)

MLPX(76) DMPX(77) SFTR(84) SBS(91) Note:

means that the flag is affected by the result of instruction execution.

181

Page 187

Appendix E Binary–Hexadecimal–Decimal Table Decimal

BCD

Hex

Binary

00

00000000

00

00000000

01

00000001

01

00000001

02

00000010

02

00000010

03

00000011

03

00000011

04

00000100

04

00000100

05

00000101

05

00000101

06

00000110

06

00000110

07

00000111

07

00000111

08

00001000

08

00001000

09

00001001

09

00001001

10

00010000

0A

00001010

11

00010001

0B

00001011

12

00010010

0C

00001100

13

00010011

0D

00001101

14

00010100

0E

00001110

15

00010101

0F

00001111

16

00010110

10

00010000

17

00010111

11

00010001

18

00011000

12

00010010

19

00011001

13

00010011

20

00100000

14

00010100

21

00100001

15

00010101

22

00100010

16

00010110

23

00100011

17

00010111

24

00100100

18

00011000

25

00100101

19

00011001

26

00100110

1A

00011010

27

00100111

1B

00011011

28

00101000

1C

00011100

29

00101001

1D

00011101

30

00110000

1E

00011110

31

00110001

1F

00011111

32

00110010

20

00100000

183