What is in it
Omron's operation manual for the SYSMAC P-type programmable controllers (C20P, C28P, C40P and C60P). It explains ladder-diagram programming from the basics, the memory areas and how I/O maps to bits, the full instruction set, program execution timing, entering and debugging programs with the Programming Console, and troubleshooting. Appendices list standard Omron products for the P-types and reference tables of instructions and console operations. Hardware details are left to the separate Installation Guide.
Its parts
- Precautions
- Background
- Hardware Considerations
- Memory Areas
- Programming
- Instruction Set
- Program Execution Timing
- Program Input, Debugging and Execution
- Troubleshooting
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is Omron's Operation Manual for the SYSMAC C20P, C28P, C40P and C60P P-type Programmable Controllers, revised January 1997. It explains ladder-diagram programming, the memory areas, the instruction set, Programming Console operation and troubleshooting. Hardware details are in a separate Installation Guide.
- I/O points
- C28P: 16 inputs and 12 outputs, occupying 2 words p. 19
- Power supply
- C28P: 100 to 240 VAC or 24 VDC models p. 165
- Program memory
- 1,194 words p. 21
- Data memory
- DM 00 to DM 63 (words only) p. 21
- Timers/counters
- TC 00 to TC 47 p. 21
- Holding relays
- HR 0 to HR 9 (bits HR 000 to HR 915), kept when power is off p. 21
- System size
- Up to five Units including the CPU, 10 words total; I/O Link Unit last p. 19
- Expansion
- Six sizes of Expansion I/O Unit, Analog Timers, Analog I/O Units, or an I/O Link Unit p. 164
- Indicators
- POWER, RUN, ERR (fatal error, outputs off), ALARM (operation continues) p. 19
- Programming devices
- Programming Console, Graphic Programming Console (GPC), Ladder Support Software (LSS), Factory Intelligent Terminal (FIT) p. 16
- Watchdog timer
- Scan time over 100 ms gives an alarm; over the maximum setting (default 130 ms) stops the PC p. 162
- Error flags
- 1808 Battery Alarm Flag; 1809 Scan Time Error Flag; 1903 Instruction Execution Error (ER) Flag p. 163
- LSS
- Runs on IBM AT/XT compatibles; needs a Host Link Unit p. 16
- Hardware manual
- Installation Guide W167 (hardware specifications) p. 17
What this manual walks you through
- Learning ladder-diagram programming p. 12
- Building a PC from a CPU and expansion units p. 19
- Using the memory areas (IR, SR, DM, HR, TC, TR) p. 21
- Using each instruction in the instruction set p. 4
- Entering, debugging and monitoring a program from a Programming Console p. 4
- Choosing peripheral and programming devices p. 16
- Reading and clearing error messages p. 161
- Fixing fatal and non-fatal operating errors p. 161, 162
- Finding model numbers of CPUs and expansion units p. 164, 165, 166
Good to know
- On most hardware errors and some fatal software errors the PC stops the program and turns off all outputs. p. 161
- Errors and messages can be cleared only in PROGRAM mode. p. 161
- Write down error messages as you read them, since MONTR clears them in PROGRAM mode. p. 161
- The I/O Link Unit must always be the last Unit in the series. p. 19
Questions this manual answers
How many inputs and outputs does the C28P have?
The C28P CPU provides 16 input points and 12 output points and occupies 2 words. p. 19
How much program memory does a P-type PC have?
The Program Memory (UM) holds 1,194 words. p. 21
What does a battery error mean on a C28P?
The backup battery is missing or its voltage has dropped; check the battery and replace it if needed. p. 162
How do I read error messages on the Programming Console?
Press CLR, FUN and MONTR; press MONTR again for the next message. ERR CHK OK shows when all are cleared. p. 161
What does the ALARM indicator mean?
An error was found in self-diagnosis, but PC operation continues. p. 19
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 27 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- TABLE OF CONTENTS5-7
- PRECAUTIONS8-10
- SECTION 111-17
- Pages 18 to 2718-27
- Pages 28 to 3628-36
- SECTION 4, pages 37 to 4437-44
- SECTION 4, pages 45 to 5245-52
- SECTION 5, pages 53 to 6253-62
- SECTION 5, pages 63 to 7263-72
- SECTION 5, pages 73 to 8273-82
- SECTION 5, pages 83 to 9283-92
- SECTION 5, pages 93 to 10193-101
- SECTION 6102-111
- SECTION 7, pages 112 to 121112-121
- SECTION 7, pages 122 to 131122-131
- SECTION 7, pages 132 to 141132-141
- SECTION 7, pages 142 to 151142-151
- SECTION 7, pages 152 to 159152-159
- SECTION 8160-163
- Appendix, pages 164 to 171164-171
- Appendix, pages 172 to 179172-179
- Appendix, pages 180 to 187180-187
- Appendix, pages 188 to 194188-194
- Glossary, pages 195 to 201195-201
- Glossary, pages 202 to 208202-208
- Index209-211
The file