The text of a manual · part 26 of 27
SYSMAC C20P/C28P/C40P/C60P P-type Programmable Controllers Operation Manual: Glossary, pages 202 to 208
Pages 202 to 208 of 211, from SYSMAC C20P/C28P/C40P/C60P P-type Programmable Controllers Operation Manual
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Omron C28P
Page 202
Glossary nest
Programming one jump within another jump, programming a call to a subroutine from within another subroutine, etc.
NO input
An input that is normally open, i.e., the input signal is considered to be present when the circuit connected to the input closes.
noise interference
Disturbances in signals caused by electrical noise.
nonfatal error
A hardware or software error that produces a warning but does not stop the PC from operating.
normal condition
A condition that produces an ON execution condition when the bit assigned to it is ON and an OFF execution condition when the bit assigned to it is OFF.
NOT
A logic operation which inverts the status of the operand. For example, AND NOT indicates an AND with the opposite of the actual status of the operand bit.
OFF
The status of an input or output when a signal is said not to be present. The OFF state is generally low voltage or non-conductivity, but can be defined as the opposite of either.
OFF delay
The delay produced between the time turning OFF a signal is initiated (e.g., by an input device or PC) and the time the signal reaches a state readable as an OFF signal (i.e., as no signal) by a receiving party (e.g., output device or PC).
ON
The status of an input or output when a signal is said to be present. The ON state is generally high voltage or conductivity, but can be defined as the opposite of either.
ON delay
The delay produced between the time a signal is initiated (e.g., by an input device or PC) and the the time the signal reaches a state readable as an ON signal by a receiving party (e.g., output device or PC).
one-shot bit
A bit that is turned ON or OFF for a specified interval of time longer than one scan.
operand
A bit(s) or word(s) designated as the data to be used for an instruction. An operand can be input as a constant expressing the actual numeric value to be used or as an address to express the location in memory of the data to be used.
operand bit
A bit designated as an operand for an instruction.
operand word
A word designated as an operand for an instruction.
operating error
An error that occurs during actual PC operation as opposed to an initialization error, which occurs before actual operations can begin.
Optical Slave Rack
A Slave Rack connected through an Optical Remote I/O Slave Unit.
OR
A logic operation whereby the result is true if either one or both of the premises is true. In ladder-diagram programming the premises are usually ON/ OFF states of bits or the logical combination of such states called execution conditions.
200
Page 203
Glossary output
The signal sent from the PC to an external device. Output often is used abstractly or collectively to refer to outgoing signals.
output bit
A bit in the IR area that is allocated to hold the status to be sent to an output device.
output device
An external device that receives a signal(s) from the PC System.
output point
The point at which an output leaves the PC System. An output point physically corresponds to terminals or connector pin(s).
output signal
A change in the status of a connection leaving the PC. Generally an output signal is said to exist when, for example, a connection point goes from low to high voltage or from a nonconductive to a conductive state.
overseeing
Part of the processing performed by the CPU that includes general tasks required to operate the PC.
overwrite
Changing the content of a memory location so that the previous content is lost.
PC
An acronym for Programmable Controller.
PC System
All of the Units connected to the CPU Unit up to, but not including the I/O devices. The limits of the PC System on the upper end is the PC and the program in its CPU and on the lower end, I/O Units, an I/O Link Unit, etc.
PCB
An acronym for printed circuit board.
Peripheral Device
Devices connected to a PC System to aid in system operation. Peripheral devices include printers, programming devices, external storage media, etc.
present value
The current time left on a timer or the current count of a counter. Present value is abbreviated PV.
printed circuit board
A board onto which electrical circuits are printed for mounting into a computer or electrical device.
program
The list of instructions that tells the PC the sequence of control actions to be carried out.
Programmable Controller
A computerized device that can accept inputs from external devices and generate outputs to external devices according to a program held in memory. Programmable Controllers are used to automate control of external devices.
programmed alarm
An alarm given as a result of execution of an instruction designed to generate the alarm in the program as opposed to one generated by the system.
programmed error
An error arising as a result of execution of an instruction designed to generate the error in the program as opposed to one generated by the system.
programmed message
A message generated as a result of execution of an instruction designed to generate the message in the program as opposed to one generated by the system.
201
Page 204
Glossary Programming Console
The simplest form or Programming Device available for a PC. Programming Consoles are available both as hand-held models and as CPU-mounting models.
Programming Device
A peripheral device used to input a program into a PC or to alter or monitor a program already held in the PC. There are dedicated programming devices, such as Programming Consoles, and there are non-dedicated devices, such as a host computer.
PROGRAM mode
A mode of operation that allows for inputting and debugging programs but that does not permit normal execution of the program.
PROM Writer
A Peripheral Device used to write programs and other data into a ROM for permanent storage and application.
prompt
A message or symbol that appears on a display to request input from the operator.
PV
Short for present value.
refresh
The process of updating output status sent to external devices so that it agrees with the status of output bits held in memory and of updating input bits in memory so that they agree with the status of inputs from external devices.
relay-based control
The forerunner of PCs. In relay-based control, groups of relays are wired to each other to form control circuits. In a PC, these are replaced by programmable circuits.
Remote I/O Master Unit
The Unit in a Remote I/O System through which signals are sent to all other Remote I/O Units. The Remote I/O Master Unit is mounted either to a C200H, C500, C1000H, or C2000H CPU Rack or an Expansion I/O Rack connected to the CPU Rack. Remote I/O Master Unit is generally abbreviated to simply “Master.”
Remote I/O Slave Unit
A Unit mounted to a C200H, C500, C1000H, or C2000H Backplane to form a Slave Rack. Remote I/O Slave Unit is generally abbreviated to simply “Slave.”
Remote I/O System
A C200H, C500, C1000H, or C2000H system in which remote I/O points are controlled through a Master mounted to a CPU Rack or an Expansion I/O Rack connected to the CPU Rack. K-type PCs can be connected to Remote I/O Systems through I/O Link Units.
Remote I/O Unit
Any of the Units in a Remote I/O System. Remote I/O Units include Masters, Slaves, Optical I/O Units, I/O Link Units, and Remote Terminals.
reset
The process of turning a bit or signal OFF or of changing the present value of a timer or counter to its set value or to zero.
return
The process by which instruction execution shifts from a subroutine back to the point from which the subroutine was called. A return is automatic upon completion of the subroutine and the return is always to .
reversible counter
A counter that can be both incremented and decrement depending on a specified condition(s).
202
Page 205
Glossary reversible shift register
A shift register that can shift data in either direction depending on a specified condition(s).
right-hand instruction
Another term for terminal instruction.
rightmost (bit/word)
The lowest numbered bits of a group of bits, generally of an entire word, or the lowest numbered words of a group of words. These bits/words are often called least significant bits/words.
RUN mode
The operating mode used by the PC for normal control operations.
scan
The process used to execute a ladder-diagram program. The program is examined sequentially from start to finish and each instruction is executed in turn based on execution conditions.
scan time
The time required for a single scan of the ladder-diagram program.
self diagnosis
A process whereby the system checks its own operation and generates a warning or error if an abnormality is discovered.
self-maintaining bit
A bit that is programmed to maintain either an OFF or ON status until set or reset by a specific condition(s) different from the one that originally caused the bit to turn OFF or ON.
servicing
The process whereby the PC provides data to or receives data from external devices or remote I/O or otherwise handles data transactions for Link Systems.
set
The process of turning a bit or signal ON.
set value
The count from which a counter starts counting down (or, in the case of a reversible counter, the maximum count) or the time from which a timer starts timing. Set value is abbreviated SV.
shift register
One or more words in which data is shifted in bit, digit, or word units a specified number of units to the right or left.
Slave
Short for Remote I/O Slave Unit.
Slave Rack
A C200H, C500, C1000H, or C2000H Rack containing a Remote I/O Slave Unit and controlled through a Remote I/O Master Unit. Slave Racks are generally located away from the CPU Rack.
software error
An error that occurs in the execution of a program.
software protects
A software means of protecting data from being changed as opposed to a physical switch or other hardware setting.
source
The location from which data is taken for use in an instruction as opposed to the location to which the result of an instruction is to be written. The location to which the result of an instruction is to be written is called the destination.
SR area
A data area in a PC used mainly for flags, control bits, and other information provided about PC operation. The status of only certain SR bits may be controlled by the operator, i.e., most SR bits can only be read.
203
Page 206
Glossary subroutine
A group of instructions placed after the main program and executed only if called from the main program or activated by an interrupt.
subroutine number
A definer used to identify the subroutine that a subroutine call or interrupt activates.
SV
Short for set value.
switching capacity
The voltage/current that a relay can switch on and off.
syntax error
An error in the way in which a program is written. Syntax errors can include ‘spelling’ mistakes (i.e., a function code that does not exit), mistakes in specifying operands within acceptable parameters (e.g., specifying unwritable SR bits as a destination), and mistakes in actual application of instructions (e.g., a call to a subroutine that does not exist).
system error
An error generated by the system as opposed to one resulting from execution of an instruction designed to generate an error.
system error message
An error message generated by the system as opposed to one resulting from execution of an instruction designed to generate a message.
TC area
A data area that can be used only for timers and counters. Each bit in the TC area serves as the access point for the SV, PV, and Completion flag for the timer or counter defined with that bit.
TC number
A definer that corresponds to a bit in the TC area and used to define the bit as either a timer or a counter.
terminal instruction
An instruction placed on the right side of a ladder diagram that uses the final execution condition on an instruction line(s).
timer
A location in memory accessed through a TC bit and used to time down from the timer’s set value. Timers are turned ON and reset according to their execution conditions.
TM area
A memory area used to store the results of a trace.
transmission distance
The distance that a signal can be transmitted.
TR area
A data area used to store execution conditions so that they can be reloaded later for use with other instructions.
transfer
The process of moving data from one location to another within the PC or between the PC and external devices. When data is transferred, generally a copy of the data is sent to the destination, i.e., the content of the source of the transfer is not changed.
UM area
The memory area used to hold the active program, i.e., the program that is being currently executed.
Unit
In OMRON PC terminology, the word Unit is capitalized to indicate any product sold for a PC System. Though most of the names of these products end with the word Unit, not all do, e.g., a Remote Terminal is referred to in a collective sense as a Unit. Context generally makes any limitations of this word clear.
204
Page 207
Glossary unit number
A number assigned to some Link Units and Special I/O Units to assign words and sometimes other operating parameters to it.
watchdog timer
A timer within the system that ensures that the scan time stays within specified limits. When limits are reached, either warnings are given or PC operation is stopped depending on the particular limit that is reached. Although a default value of 130 ms is automatically set for the basic time limit, this value can be extended by the program.
Wired Slave Rack
A Slave Rack connected through a Wired Remote I/O Slave Unit.
word
A unit of storage in memory that consists of 16 bits. All data areas consists of words. Some data areas can be accessed by words; others, by either words or bits.
word address
The location in memory where a word of data is stored. A word address must specify (sometimes by default) the data area and the number of the word that is being addressed.
work bit
A bit in a work word.
work word
A word that can be used for data calculation or other manipulation in programming, i.e., a ‘work space’ in memory. A large portion of the IR area is always reserved for work words. Parts of other areas not required for special purposes may also be used as work words, e.g., I/O words not allocated to I/O Units.
205
Page 208
Index A ADD(30). See instruction set analog timer unit. See instruction set AND. See instruction set and inverse − AND NOT. See instruction set AND LD. See instruction set AND load. See instruction set AND NOT. See instruction set arithmetic operation flags. See data areas
B backup. See cassette tape operation battery alarm flag. See data areas BCD add calculation − ADD(30). See instruction set BCD subtract calculation − SUB(31). See instruction set BCD to binary conversion − BIN(23). See instruction set BCD(24). See instruction set BIN(23). See instruction set binary table, 183 Binary to BCD conversion − BCD(24). See instruction set bits force set/reset, 148 monitor, 145 self maintaining, 42 branching. See ladder diagram
C carry flag. See data areas cassette tape operation, comparing program memory data, 141 error messages, 140 restoring program memory data, 141 saving program memory data, 140 CLC(41). See instruction set clear carry − CLC(41). See instruction set clock pulse bits. See data areas CMP(20). See instruction set CNTR(12). See instruction set compare − CMP(20). See instruction set comparing program/memory data. See cassette tape operation control bits, usage, 12 control system, definition of, 3 correction3, 2 , 6 , 7 , 12 , 43 , 50 , 82 , 83 , 85 , 86 , 87 , 102 , 103 , 145 counter − CNT. See instruction set cpu indicators, 10
D data areas components, 12 data memory area, 26 holding relay area, 26 internal relay area I/O bits available in CPUs, 17 in expansion I/O units, 18 , 19 word allocation, 16 special relay area arithmetic flags, 25 operation, 181 battery alarm flag, 24 clock pulse bits, 24 error flag, 25 operation, 181 first scan flag, 25 high speed drum/counter reset, 24 normally OFF/ON flags, 25 scan time error flag, 24 usage, 24 structure, 12 temporary relay area, 27 timer/counter area, 26 data decoder (4 to 16) − MLPX(76). See instruction set data encoder − DMPX(77). See instruction set data memory area. See data areas digit, monitor, 145 DM area. See data areas DMPX(77). See instruction set
E end − END(01). See instruction set END(01). See instruction set equal flag. See data areas error flag. See data areas errors cassette tape operations, 140 fatal, 155 message tables, 154 non−fatal, 154 reading and clearing messages, 154 SR area flags, 156
F factory intelligent terminal. See peripheral devices first scan flag. See instruction set FIT. See peripheral devices flags execution affect, 47 usage, 12
207