SYSMAC C20P/C28P/C40P/C60P P-type Programmable Controllers Operation Manual: Appendix, pages 164 to 171

Pages 164 to 171 of 211, from SYSMAC C20P/C28P/C40P/C60P P-type Programmable Controllers Operation Manual

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron C28P

Page 164

Appendix A Standard Models There are four basic sizes of P-type C-series CPU. A CPU can be combined with any of six basic sizes of Expansion I/O Unit and/or Analog Timers, Analog I/O Units, or an I/O Link Unit.

CPUs C20P–C_ _–_

Expansion I/O Units

Analog Timer Unit

C4K–I_/O_ _

C4K–TM

C20P To order cable separately, specify C4K–CN502

C28P

C40P

C60P–C_ _–_

C60P

Analog I/O Units C16P–I_–_/O_–_

C28P–C_ _–_

C40P–C_ _–_

C4K–CN502 (included with Unit)

C1K–AD/DA

C16P 5 cm or 40 cm One included with each Expansion I/O Unit.

Cable (70 cm) C20P–CN711 (ordered separately)

C20P–E_ _–_

C20P

C4K–AD C4K – AD

C28P–E_ _–_

C28P

C40P–E_ _–_

C40P

I/O Link Unit C20–LK011/LK011–P

C60P–E_ _–_

C60P

157

Page 165

Appendix A

Standard Models

CPUs Name C20P

Power supply 100 to 240 VAC

24 VDC

C28P

100 to 240 VAC

24 VDC

C40P

100 to 240 VAC

24 VDC

C60P

100 to 240 VAC

24 VDC

Inputs 24 VDC, 12 pts.

Outputs

U, C

Transistor, 0.5 A

C20P–CDT–AE

U, C

Transistor, 1 A

C20P–CDT1–AE

U

Triac, 1 A

C20P–CDS1–AE

U, C

24 VDC, 2 pts. 100 VAC, 10 pts.

Relay with socket

C20P–CAR–AE

U, C

24 VDC, 12 pts.

Relay with socket

C20P–CDR–DE

U, C

Transistor, 0.5 A

C20P–CDT–DE

U

Transistor, 1 A

C20P–CDT1–DE

U

Relay with socket

12 pts. C28P–CDR–AE

U, C

Transistor, 0.5 A

C28P–CDT–AE

U, C

Transistor, 1 A

C28P–CDT1–AE

U, C

Triac, 1 A

C28P–CDS1–AE

U, C

24 VDC, 2 pts. 100 VAC, 14 pts.

Triac, 1A

C28P–CAS1–AE

U, C

24 VDC, 24 pts.

Relay with socket

C40P–CDR–DE

U, C

Transistor, 0.5 A

C28P–CDT–DE

U

Transistor, 1 A

C28P–CDT1–DE

U

24 VDC, 24 pts.

Relay with socket

16 pts. C40P–CDR–AE

U, C

Transistor, 0.5 A

C40P–CDT–AE

–––

Transistor, 1 A

C40P–CDT1–AE

U, C

Triac, 1 A

C40P–CDS1–AE

U, C

24 VDC, 2 pts.

Relay with socket

C40P–CAR–AE

C

100 VAC, 22 pts.

Triac, 1 A

C40P–CAS1–AE

U, C

24 VDC, 24 pts.

Relay with socket

C40P–CDR–DE

U, C

Transistor, 0.5 A

C40P–CDT–DE

U

Transistor, 1 A

C40P–CDT1–DE

U

28 pts. C60P–CDR–AE

–––

Transistor, 1 A

C60P–CDT1–AE

–––

Triac, 1 A

C60P–CDS1–AE

–––

24 VDC, 2 pts.

Relay with socket

C60P–CAR–AE

–––

100 VAC, 30 pts.

Triac, 1 A

C60P–CAS1–AE

–––

24 VDC, 32 pts.

Relay with socket

C60P–CDR–DE

–––

Transistor, 1 A

C60P–CDT1–DE

–––

24 VDC, 32 pts.

Relay with socket

•

158

8 pts.

Standards

C20P–CDR–AE

24 VDC, 16 pts.

Relay with socket

Model number

U: UL, C: CSA, N: NK See Omron sales representatives concerning operating conditions under which UL, CSA, and NK standards were met (Aug. 1988).

Page 166

Appendix A

Standard Models

Expansion I/O Units Name C4K Expansion

Power supply –––

I/O Unit

C16P Expansion

100 to 240 VAC

I/O Unit

–––

24 VDC

C20P Expansion

100 to 240 VAC

Inputs 24 VDC, 4 pts.

Outputs –––

Model number 4 pts.

C4K–ID

U, C

100 to 120 VAC, ––– 4 pts.

C4K–IA

U, C

–––

Relay with socket

C4K–OR2

U, C

Transistor, 1 A

C4K–OT2

U, C

Triac, 1A

C4K–OS2

U, C

C16P–ID–A

U, C

24 VDC, 16 pts.

–––

–––

Relay with socket

C16P–OR–A

U, C

Transistor, 1 A

C16P–OT1–A

U, C

Triac, 1A

C16P–OS1–A

U, C

–––

C16P–ID

U, C

100 to 120 VAC, ––– 16 pts.

C16P–IA

U, C

–––

Relay with socket

C16P–OR–D

U

Transistor, 1 A

C16P–OT1–D

U

C20P–EDR–A

U, C, N

Transistor, 1 A

C20P–EDT1–A

N

Triac, 1A

C20P–EDS1–A

U, C, N

C20P–EAR–A

U, C, N

Triac, 1A

C20P–EAS1–A

U, C, N

Relay with socket

C20P–EDR–D

U, C, N

Transistor, 1 A

C20P–EDT1–D

–––

C28P–EDR–A

U, C, N

Transistor, 1 A

C28P–EDT1–A

N

Triac, 1A

C28P–EDS1–A

U, C, N

C28P–EAR–A

U, C

Triac, 1A

C28P–EAS1–A

U, C, N

Relay with socket

C28P–EDR–D

U, C, N

Transistor, 1 A

C28P–EDT1–D

–––

24 VDC, 16 pts.

24 VDC, 12 pts.

I/O Unit

Relay with socket

16 pts.

8 pts.

100 to 120 VAC, Relay with socket 12 pts.

24 VDC

C28P Expansion

100 to 240 VAC

24 VDC, 12 pts.

24 VDC, 16 pts.

I/O Unit

Relay with socket

100 to 120 VAC, Relay with socket 16 pts.

24 VDC

Standards

24 VDC, 16 pts.

12 pts.

159

Page 167

Appendix A

Standard Models Name

Power supply

Inputs

C40P Expansion

100 to 240 VAC

24 VDC, 24 pts.

I/O Unit

Outputs Relay with socket

Model number 16 pts.

C40P–EDR–A

U, C, N

Transistor, 1 A

C40P–EDT1–A

–––

Triac, 1A

C40P–EDS1–A

U, C, N

C40P–EAR–A

U, C, N

Triac, 1A

C40P–EAS1–A

U, C, N

Relay with socket

C40P–EDR–D

U, C, N

Transistor, 1 A

C40P–EDT1–D

–––

C60P–EDR–A

–––

Transistor, 1 A

C60P–EDT1–A

–––

Triac, 1A

C60P–EDS1–A

–––

Relay with socket

C60P–EAR–A

–––

Triac, 1A

C60P–EAS1–A

–––

Relay with socket

C60P–EDR–D

–––

Transistor, 1 A

C60P–EDT1–D

–––

100 to 120 VAC, Relay with socket 24 pts.

24 VDC

C60P Expansion

100 to 240 VAC

24 VDC, 24 pts.

24 VDC, 32 pts.

I/O Unit

100 VAC, 32 pts.

24 VDC

24 VDC, 32 pts.

Relay with socket

•

160

Standards

28 pts.

U: UL, C: CSA, N: NK See Omron sales representatives concerning operating conditions under which UL, CSA, and NK standards were met (Aug. 1988).

Page 168

Appendix A

Standard Models

Special Units Name

Specifications

Model number

Standards

Analog Timer Unit

Settings: 0.1 s to 10 min (C4K–CN502 Cable, included)

C4K–TM

–––

Analog Timer Variable Resistor Connector

2–m cable and connector

C4K–CN223

–––

Analog Input Unit

1 input; input ranges: 4 to 20 mA, 1 to 5 V

C1K–AD

–––

4 inputs; input ranges: 4 to 20 mA, 1 to 5 V

C4K–AD

–––

Analog Output Unit

1 output; output ranges: 4 to 20 mA, 1 to 5 V

C1K–DA

–––

Host Link Unit

RS–232C

3G2C7–LK201–EV1

–––

RS–422

3G2C7–LK202–EV1

–––

APF/PCF

C20–LK011–P

–––

PCF

C20–LK011

–––

For horizontal mounting; cable length: 5 cm (for maintenance)

C20P–CN501

–––

For vertical mounting; cable length: 40 cm (for maintenance)

C20P–CN411

–––

For horizontal mounting; connects to

Cable length: 5 cm

C4K–CN502

–––

C4K I/O Units, Analog Timer Unit, or

Cable length: 50 cm C4K–CN512

–––

Analog I/O Units (for maintenance)

Cable length: 1 m

C4K–CN122

–––

I/O Link Unit

I/OConnectingCable

I/OConnecting Cable

I/O Link Connecting Cable

Cable length: 70 cm; for I/O Link Units only

C20P–CN711

–––

EPROM

2764

ROM–H

–––

Battery Set

Built into CPU (same for all C–series PCs)

3G2A9–BAT08

–––

Relay

24-VDC contact relay

G6B–1174P–FD–US

U, C

24-VDC transistor relay

G3SD–Z01P–PD–US

U, C

24-VDC triac relay

G3S–201PL–PD–US

U, C

161

Page 169

Appendix A

Standard Models

DIN Products Name DIN Track

Specifications Length: 50 cm

Model number

Standards

Not usable with C60P PFP–50N

Length: 1 m

PFP–100N

–––

PFP–100N2 End Plate

–––

PFP–M

Spacer

–––

PFP–S

Factory Intelligent Terminal (FIT) Name FIT

Specifications

Model number

1. FIT Computer FIT10–SET11–E 2. SYSMATE Ladder Pack (2 system disks, 1 data disk) 3. MS-DOS 4. GPC Communications Adapter (C500–IF001) 5. Peripheral Connecting Cable (3G2A2–CN221) 6. Power Cord and 3-pin/2-pin plug 7. Carrying Case

Standards –––

Graphic Programming Console (GPC) Name GPC (LCD display)

Specifications

Model number

Standards

With battery; power supply: 32 kw, 100 to 120 VAC; with 3G2C5–GPC03–E comments;SystemMemoryCassetteorderedseparately. With battery; power supply: 32 kw, 200 to 240 VAC; with 3G2C5–GPC04–E comments;SystemMemoryCassetteorderedseparately.

GPC Carrying Case

With side pocket for accessories

C500–CS001

GPC System Memory With comments Cassette

3G2C5–MP303–EV2

Cassette Interface Unit

3G2A5–CMT01–E

Used to load programs in V8, M1R, M5R, POR, or S6 cassettes into the GPC and print them out through a Printer Interface Unit.

•

162

–––

U: UL, C: CSA, N: NK See Omron sales representatives concerning operating conditions under which UL, CSA, and NK standards were met (Aug. 1988).

Page 170

Appendix A

Standard Models Peripheral Devices Name Programming Console

Specifications

Model number

Standards

Vertical, with backlight

3G2A5–PRO13–E

U, C

Horizontal, with backlight

3G2A6–PRO15–E

–––

Hand-held, with backlight. The Programming Console C200H–PR027–E Adapter AP003 and connecting cable CN222/CN422 are necessary. They are sold separately.

U, C

Programming Console Mounting Bracket

Used to attach Hand-held Programming Console to a panel.

C200H–ATT01

–––

Programming Console

For C20P/C28P/C40P/C60P only

1m

3G2C7–CN122

–––

50 cm

3G2C7–CN512

–––

2m

C200H–CN222

U, C

4m

C200H–CN422

U, C

Connecting Cables For Hand-held Programming Console

Programming Console Adapter

Used with C200H–PRO27 and C200H–CN222

3G2A5–AP003

–––

Cassette Recorder Connecting Cable

Used to connect Programming Console, GPC, or Cassette Deck Interface Unit to a cassette deck; length: 1 m.

SCYPOR–PLG01

–––

PROM Writer

Used for all P–type PCs.

3G2A5–PRW06

–––

Printer Interface Unit

Interface for X–Y plotter or printer; System Memory Cassette ordered separately.

3G2A5–PRT01–E

–––

Memory Pack

When mounting P-type CPUs

C20–MP009–EV3

Printer Connecting Cable 2 m (also used for X–Y plotter)

SCY–CN201

Floppy Disk Interface Unit C20P/C28P/C40P. With comment file; able to connect to 3G2C5–FDI03–E NEC floppy disk controller Peripheral Interface Unit

To connect GPC or FIT to P–type PCs

Connecting Cable

Used to connect FIT or GPC to

2m

3G2A2–CN221

Peripheral Interface Unit and to

5m

3G2A5–CN523 connect Programming Console

10 m

3G2A5–CN131

Adapter and Programming Console

20 m

3G2A5–CN231

Base.

30 m

3G2A5–CN331

40 m

3G2A5–CN431

50 m

3G2A5–CN531

–––

–––

3G2C7–IP002–V2

–––

163

Page 171

Appendix B Programming Instructions A PC instruction is input either by inputting the corresponding Programming Console key(s) (e.g., LD, AND, OR, NOT) or by using function codes. To input an instruction via its function code, press FUN, the function code, and then WRITE. Name

Function code

Mnemonic

Page

––

AND

AND

48

––

AND Load

AND LD

49

––

AND NOT

AND NOT

48

––

Counter

CNT

64

––

Load

LD

48

––

Load NOT

LD NOT

48

––

OR

OR

48

––

OR NOT

OR NOT

48

––

OR Load

OR LD

49

––

Output

OUT

49

––

Output NOT

OUT NOT

49

––

Timer

TIM

57

00

No Operation

NOP

56

01

End

END

56

02

Interlock

IL

53

03

Interlock Clear

ILC

53

04

Jump

JMP

55

05

Jump End

JME

55

10

Shift Register

SFT

78

11

Keep

KEEP

51

12

Reversible Counter

CNTR

67

13

Differentiate Up

DIFU

50

14

Differentiate Down

DIFD

50

15

High–speed Timer

TIMH

61

16

Word Shift

WSFT

80

20

Compare

CMP

82

21

Move

MOV

81

22

Move NOT

MVN

82

23

BCD to Binary

BIN

84

24

Binary to BCD

BCD

85

30

BCD Add

ADD

90

31

BCD Subtract

SUB

92

40

Set Carry

STC

93

41

Clear Carry

CLC

93

76

4 to 16 Decoder

MLPX

85

77

16 to 4 Encoder

DMPX

87

98

High–speed Counter

HDM

68

165