Page 11

ES100X/P

ES100X/P Current Transformer Ratings Max. continuous heater current

50 A

Dielectric strength

1,000 VAC (for 1 min)

Vibration resistance

50 Hz (approx. 10G)

Weight

E54-CT1: Approx. 11.5 g; E54-CT3: Approx. 50 g

Accessories (E54-CT3 only)

Contact: 2; Plug: 2

Controller Characteristics Item

ES100X

ES100P

Indication accuracy (see note)

Thermocouple (±0.1% of indication value or ±1°C, whichever greater) ±1 digit max. Platinum resistance thermometer (±0.1% of indication value or ±0.5°C, whichever greater) ±1 digit max. Voltage/current input (±0.1% FS, ±1 digit max.)

ON/OFF control hysteresis

0.01% to 99.99% FS (in units of 0.01%)

Proportional band

0.0% to 999.9% FS (ON/OFF control when 0.0%) 0.1% to 999.9% FS (proportional position model) (in units of 0.1%)

Integral (reset) time

0 to 9,999 s (PD control when 0 s) (in units of 1 s)

Derivative (rate) time

0 to 9,999 s (PI control when 0 s) (in units of 1 s)

Fuzzy intensity

0.0% to 100.0% (Advanced PID control (2-PID) when 0.0%) (in units of 0.1%)

Event set value

Equivalent to –200.0% to 200.0% FS of industrial value or unit

Control period

1 to 120 s (in units of 1 s)

Sampling period

0.1 s min. type 0.2 s (in units of 1 s)

Display refresh period

As large as, twice as large as, 5 times as large as, or 10 times as large as control operation period

PV compensation

Equivalent to –100.0% to 100.0% FS of industrial value or unit

Manual manipulated value

–5.0% to 105.0%

Manipulated value limit

Lower limit: –5.0% to –0.1% max.; upper limit: +0.1% min. to 105.0%

Setting time (1 step)

---

0 to 99 hours 59 minutes or 0 to 99 minutes 59 seconds

Program capacity

---

Total steps 400 max. (99 patterns, 99 steps)

Programming method

---

Break point method (patterns can be decided by the user)

Insulation resistance

20 MΩ min.

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min between terminals of different polarities

Vibration resistance

Malfunction:10 to 150 Hz, 0.5-mm single amplitude each in X, Y, and Z directions Destruction:10 to 150 Hz, 0.75-mm single amplitude each in X, Y, and Z directions

Shock resistance

Malfunction:20G max., 3 times each in 6 directions Destruction:30G max., 3 times each in 6 directions (20G’s in the forward direction)

Ambient temperature

Operating: –10° to 55°C (with no icing) Storage: –25° to 65°C (with no icing)

Ambient humidity

Operating: 35% to 85%

Memory protection

Lithium cell backup (10 years at normal room temperature)

Enclosure ratings

Front panel: IEC standard IP50 (with water proof cover: IP66, NEMA4) Rear case: IEC standard IP20 Terminals: IEC standard IP00 (with terminal cover: VDE 0106/P100)

Weight

Approx. 800 g

Note:

Indication accuracy varies with the type of sensor and the sensing temperature as follows: K and T sensor (–100°C max.), R, S, and W sensor (200°C max.), and U sensor: ±2°C±1 digit; B sensor (400°C max.): ±6°C±1 digit Indication accuracy without using the built-in cold contact compensation circuit is ±0.1% FS or ±1°C whichever is smaller except for the following sensors: R and S sensor (200°C max.): ±1.5±1 digit; L2 and U sensor: ±1°C±1 digit

Output Unit Characteristics Relay Unit life expectancy

Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min.

11

Page 12

ES100X/P

ES100X/P Heater Burnout Detection Characteristics Max. heater current

50 A, single-phase

Monitor accuracy of input current

±5% FS ±1 digit max.

Heater burnout detection setting range

0.0 to 50.0 A (see note 1)

Heater current monitor range

0.0 to 55.0 A

Min. detectable ON time

200 ms (see note 2)

Note:

1. Heater burnout is not detected when current is set to 0.0 A; the burnout alarm will be automatically turned ON when current is set to 50.0 A. 2. When the control output is ON for less than 200 ms, heater burnout is not detected and heater current is not measured.

Watertight Cover Characteristics Enclosure ratings

Front cover: IEC standard IP66, conforming to NEMA 4

Terminal Cover Characteristics Enclosure ratings

Conforming to VDE0106/P100

Support Software Characteristics (For Windows) Personal computer

Windows-compatible computer with Pentium or higher, and 800 x 600 min. display.

OS

Windows 95, Windows 98, Windows NT4.0, or Windows 2000

Main memory

16 MB for Windows 95 and Windows 98 24 MB for Windows NT and Windows 2000

Communications method

RS232C; half-duplex

Transmission speed

9,600 bps

Printer

Windows-compatible printer

Communications Communications

RS-232C

RS-422

RS-485

Transmission method

None, half-duplex

4-wire, half-duplex

2-wire, half-duplex

Synchronization method

Start-stop synchronization

---

Baud rate

1,200/2,400/4,800/9,600/19,200 bps

---

Transmission code

ASCII (7-bit) (see note 3)

---

Note:

BCD Data select code method

Transmission output 4 to 20 mA Load: 600 Ω max. resolution: 12-bit

1. The maximum total cable length must not exceed the following limits. RS-422: 500 m, RS-232C: 15 m, RS-485: 500 m 2. A maximum of 32 Temperature Controllers can be connected to one host computer using serial communications (RS-422 or RS-485). 3. 8-digit ASCII codes can be also used.

12

Page 13

ES100X/P

ES100X/P

Operation Sampling Period The sampling period of the ES100-series Digital Temperature Controller is factory-set to 200 ms If only the advanced PID control is used, the sampling period will vary with the Model as follows (with a baud rate of 9,600 bps for the Models incorporating a communications function): Model

Sampling period

Model

Sampling period

ES100X-AAH

100 ms

ES100X-AAHFB

100 ms

ES100X-AAHFD

100 ms

ES100X-AAHFE

100 ms

ES100X-AAWHFB

100 ms

ES100X-AAWHFE

100 ms

ES100X-AAH01FE

100 ms

ES100X-AAH04FE

100 ms

ES100X-AAWH01FE

200 ms

ES100X-AAWH04FE

200 ms

ES100X-RRPFB

100 ms

ES100X-RRPFD

100 ms

ES100X-RRPFE

100 ms

ES100X-RRPWFB

100 ms

ES100X-RRPWFE

100 ms

ES100X-RRP01FE

100 ms

ES100X-RRP04FE

100 ms

ES100X-RRPW01FE

200 ms

ES100X-RRPW04FE

200 ms

ES100P-AAH

100 ms

ES100P-AAHFD

100 ms

ES100P-AAHFE

100 ms

ES100P-AAWHFE

200 ms

ES100P-AAH01FE

200 ms

ES100P-AAH04FE

200 ms

ES100P-AAWH01FE

200 ms

ES100P-AAWH04FE

200 ms

ES100P-RRPFD

200 ms

ES100P-RRPFE

200 ms

ES100P-RRPWFE

200 ms

ES100P-RRP01FE

200 ms

ES100P-RRP04FE

200 ms

ES100P-RRPW01FE

200 ms

ES100P-RRPW04FE

200 ms

The control operation period is an important factor for the following control operations (refer to ES100X/ES100P Operation Manual for details): Heating/cooling control Cascade control Fuzzy control Analog I/O assignment Digital I/O assignment No. of events used No. of times that ON/OFF timer used Input type selector (linearization required or not) Terminal communications baud rate Use of digital I/O (BCD communication) The control operation period can be checked with the monitor (character P229) in the check mode.

Product Inspection Sheet Contact your OMRON representative if Product Inspection Sheet are required.

Dimensions Note:

All units are in millimeters unless otherwise indicated.

ES100X ES100P

13 j96

112

Panel Cutouts

169 160* j91

110 mm min.

120 mm min. 92 mm

*175 mm with a terminal cover

92 mm When mounting more than one Unit

13

Page 14

ES100X/P

ES100X/P Y92A-96N Watertight Cover

20.5 92

2

10

131.8

125.3

92

115.6 28

E53-COV01 Terminal Cover 81.9

88.2 72.8

66.9

23

Installation Factory Allocations of Terminal Functions Basic Model ES100j-AAH 34

17 NOT USED

CT input 16

7

CT 32

15 6 b

22 13

4

3

SUB1 (upper-limit a alarm output) 2 EV1 c 1

31

14

A02

– –

23

+

5 AO1 (control output)

30 21

SUB2 12 (upper-limit alarm output) EV2 11

20

Expansion connector

AI1 analog input 1 (K1)

29

28 19

+ 27

10 18 9

14

33 24

Power supply

+

35

25

8

– 26

The allocation shown in the diagrams is applicable to all Basic Models. Input K1: –200 to 1,300°C Control output: Heating control Auxiliary output: Upper-limit deviation alarm (to be set with EV1 and EV2) If the heating/cooling control mode is selected, AO1 is used for heating and AO2 is for cooling control output. To use AO1 and AO2, purchase Output Units.

Page 15

ES100X/P

ES100X/P Terminal Functions (Fixed) of Models other than Basic Models Proportional Positioning Control ES100j-RRPjjjjj

Digital Input (Bank selectable) for ES100X ES100X-jjjjjjjB c

14 5 Open output Relay output

33

Close output Relay output

Digital I/O (Possible to Relocate) of Models other than Basic Models w 32

13

4 o

Initial setting: Used to select a bank. The terminals operate as follows: DI1[BNK0] BNK0: 20 23 BNK1: 21 2 BNK2: 2 DI2[BNK1] 22

31 DI3 [BNK2]

Upper Link RS-232C ES100j-jjjj01jj SD

20

17

Digital I/O (Bank selectable) for ES100X ES100X-jjjjjjjD

NOT USED 25 RD

16

Initial setting: Used to select a bank. The terminals operate as follows: BNK0: 20 BNK1: 21 BNK2: 22

NOT USED 24 SG

21

15

Upper Link RS422/485 ES100j-jjjj04jj

DI1[BNK0] 23

422RDB /485+

DI2[BNK1]

17 422SDB 25

422RDA /485– SG

22

DI3 [BNK2]

16

21

422SDA 24

SUB power supply 19

15 20

Terminal Functions (Possible to Relocate) of Models other than Basic Models

SUB3

10

SUB4

9

24 V IN COM

18

Input 2 (4 to 20 mA Remote Setting) ES100j-jjWjjjjj Initial setting: Use an input of 4 to 20 mA for remote setting. The setting will be effective in the SP mode. + 10 4 to 20 mA

NOT USED 19 1 to 5 V

–

+ 18

9

AI2

Transmission Output (AI1 Process Value) ES100j-jjjjjjFj Initial setting: The value measured by analog input 1 will be output in a range of 4 to 20 mA. 4 to 20 mA + 34

– A03

35

15

Page 16

ES100X/P

ES100X/P Expansion Digital I/O for ES100X ES100X-jjjjjjjE Digital input power supply

Expansion Digital I/O for ES100P ES100P-jjjjjjjE

–

Digital input power supply 1

24 V IN +

3

24 V IN

4

+

DI1 [BNK0]

5

DI3 [BNK2]

1

2

3

4

6

DI2 [BNK1]

DI1 [RUN]

5

6

DI2 [RST]

7

8

DI4

DI3 [HOLD]

7

8

DI4

DI5

9

10

DI6

DI5

9

10

DI6

DI7

11

12

DI8

DI7

11

12

DI8

DI9

13

14

DI10

DI9

13

14

DI10

DI11

15

16

DI12

DI11

15

16

DI12

DI13

17

18

DI14

DI13

17

18

DI14

DI15 Auxiliary output power supply –

19

20

N. C

DI15 Auxiliary output power supply –

19

20

N. C

21

22

21

22

23

24

24 V IN +

23

24 V IN

24

+

SUBOUT3

25

26

SUBOUT4

SUBOUT3 (time signal 1)

25

26

SUBOUT5

27

28

SUBOUT6

SUBOUT5

27

28

SUBOUT6

SUBOUT7

29

30

SUBOUT8

SUBOUT7

29

30

SUBOUT8

SUBOUT9

31

32

SUBOUT10

SUBOUT9

31

32

SUBOUT10

34

N. C

N. C

33

34

N. C

N. C

33

Digital I/O (Operation Instruction and Time Signal) for ES100P ES100P-jjjjjjjD Initial setting: The RUN, RST, and HOLD input are used to operate the program. Time signals set by programs are output from the terminals. DI1[RUN]

DI2[RST]

23

22

DI3 [HOLD] 21

20

16

–

2

SUB3 (time signal 1) SUB4 (time signal 2)

10

SUB power supply

19 24 V IN COM

9

18

SUBOUT4 (time signal 2)

DI1 through DI8 are digital input terminals and SUBOUT3 through SUBOUT10 are digital auxiliary output terminals, both sets of which can be allocated as instructed by the user’s software. The terminals without allocation prior to shipping can be freely allocated as required by the user. DI9 through DI15 are special terminals for BCD communication.

Page 17

ES100X/P

ES100X/P

ES100 Documentation Name

Catalog no.

ES100P Digital Controller User’s Manual

H069

ES100X Digital Controller User’s Manual

H070

ES100 ES/TOOLS Support Software for Windows User’s Manual

H115

ES100 Digital Controller User’s Manual (Communications Guide)

H072

17

Page 18 read from a scan by OCR; it may hold reading errors

ES100X/P omrRonNn ES100X/P

18

Page 19 read from a scan by OCR; it may hold reading errors

ES100X/P omRON ES100X/P

19

Page 20

ES100X/P

ES100X/P

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. H058-E1-3

In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation Industrial Automation Company Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7080/Fax: (81)75-344-7189

20

Printed in Japan 0201-0.5M (0892) (A)