Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Digital Controller ES100X/P

Spec sheet · Omron

Digital Controller ES100X/P

Spec sheet20 pagesPDF 3.8 MB

Data sheet for the OMRON ES100X digital controller and ES100P programmer: models, ratings, input ranges and output units.

Download the PDF3.8 MB

Covers · 5 models

The models it covers

Summary

What is in it

OMRON's catalog data sheet for the ES100X Digital Controller and ES100P Programmer, process and temperature controllers with hybrid fuzzy logic and advanced PID control. It describes the features and example applications, then gives ordering information for every ES100X and ES100P model (including the ES100P-AAH and ES100X-AAWH01FE), temperature and input ranges, control output units, cables and accessories, the model number legend, ratings and characteristics, heater burnout detection, support software and communications.

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

This is the Omron data sheet for the ES100X digital controller and ES100P programmer series. It lists the ordering models, input ranges, ratings, output units, cables, dimensions and terminal layouts. It helps a reader pick a model with its option units and wire the main terminals.

Type
Digital controller (ES100X) and programmer (ES100P) p. 7, 8
Power
100 to 240 VAC, 50/60 Hz; approx. 20 VA (at 100 VAC) to 25 VA (at 240 VAC) p. 10
Main input
Current, voltage, thermocouple (R, S, K, J, T, E, B, N, L, U, PLII, W) or Pt100, JPt100 p. 10
Control mode
Hybrid fuzzy logic and advanced PID (2-PID) with auto-tuning and fine-tuning, or ON/OFF p. 10
Control Output Units
Sold separately: E53-R relay, E53-S SSR, E53-Q, E53-Q3, E53-Q4 voltage, E53-C3, E53-C3D current, E53-V34, E53-V35 voltage p. 7, 10
Display
Red PV digits 14.2 mm high, green SV digits 10.2 mm; green bar graph p. 10
Auxiliary outputs
Two relays (SPDT and SPST-NO), 250 VAC, 3 A p. 10
Ambient temperature
Operating –10° to 55°C; storage –25° to 65°C (no icing) p. 11
Weight
Approx. 800 g p. 11
Memory backup
Lithium cell, 10 years at normal room temperature p. 11
Host communications
ES100P-AAH01FE and ES100X-AAWH01FE: RS-232C, 1,200 to 19,200 bps p. 7, 8, 9, 12
Program capacity
ES100P: 400 steps max. in total (99 patterns, 99 steps) p. 11
Support software
ES100-YB177-E CD-ROM with cable ES100-CT023-202 (9-pin); Windows 95, 98, NT4.0 or 2000 p. 8, 9, 12
Current transformers
E54-CT1 or E54-CT3; the E54-CT2 cannot be used p. 8, 10

What this sheet walks you through

  • Choosing a model and its Control Output Unit from the ordering tables p. 7, 8
  • Reading the model number legend p. 9
  • Input ranges for each thermocouple, RTD, current and voltage type p. 8
  • Heater burnout detection settings p. 12
  • Sampling period of each model p. 13
  • Dimensions and panel cutouts p. 13
  • Factory terminal allocation of the basic models p. 14
  • Terminals for host link, remote setting input and transmission output p. 15
  • Expansion digital I/O terminals p. 16

Good to know

  • The E54-CT2 current transformer cannot be used. p. 8
  • The E53-C output unit cannot be used. p. 9
  • A CT input and a potentiometer input cannot be used at the same time. p. 10
  • Heater burnout is not detected when the control output is on for less than 200 ms. p. 12
  • Total cable length limits: RS-232C 15 m, RS-422 and RS-485 500 m. p. 12

Questions this sheet answers

What supply voltage does the Omron ES100P use?

100 to 240 VAC at 50/60 Hz, drawing about 20 VA at 100 VAC to 25 VA at 240 VAC. p. 10

Does the ES100 come with a control output?

No. A Control Output Unit such as the E53-R relay or E53-S SSR unit must be ordered with it. p. 7, 10

Which thermocouples does the ES100 accept?

Types R, S, K, J, T, E, B, N, L, U, PLII and W, plus Pt100 and JPt100 resistance thermometers. p. 10

What software and cable set up the ES100 from a PC?

The ES100-YB177-E support software for Windows; the ES100-CT023-202 cable comes with it. p. 8, 9

How many program steps does the ES100P hold?

Up to 400 steps in total, in 99 patterns of up to 99 steps. p. 11

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20

The file

Revision and size

RevisionCat. No. H058-E1-3
PublisherOMRON Corporation
Pages20
PDF3.8 MB
TextText from the PDF itself; 7 pages are scans, read by OCR, which may hold reading errors.

The first pages · 4 of 20

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 20
Page 2
Page 2of 20
Page 3
Page 3of 20
Page 4
Page 4of 20