F150-3 Vision Sensor Setup Manual: SECTION 5 CompoBus/D Connections, pages 54 to 61

Pages 54 to 61 of 96, from F150-3 Vision Sensor Setup Manual

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron F150 and Omron F150-S1A

Page 54

Z141-E1-03.book Page 39 Monday, July 24, 2006 5:16 PM

SECTION 5 CompoBus/D Connections This section describes how to connect the F150-C10E-3-DRT Vision Sensor as a CompoBus/D Slave and provides information such as connector pin allocations, node number settings, and baud rate settings. Refer to the CompoBus/D (DeviceNet) Operation Manual (W267-E1-4) for details on CompoBus/D communications specifications. Refer to the Expert Menu Operation Manual for details on setting the Vision Sensor’s communications specifications and changing the I/O format.

5-1

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

40

5-2

Communications Specifications . . . . . . . . . . . . . . . . . . .

44

5-3

DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .

45

5-4

Connector Pin Allocation . . . . . . . . . . . . . . . . . . . . . . . .

47

5-5

LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

48

5-6

Multi-vendor Applications . . . . . . . . . . . . . . . . . . . . . . .

48

39

Page 55

Z141-E1-03.book Page 40 Monday, July 24, 2006 5:16 PM

Section 5-1

Overview

5-1

Overview CompoBus/D is a multi-bit, multi-vendor network that conforms to DeviceNet open field network specifications. The F150-C10E-3-DRT Vision Sensor operates as a CompoBus/D Slave and data is automatically transferred between the Slave and Master by remote I/O communications. The number of I/O bytes handled by the Vision Sensor depends upon the communications specifications settings, so be sure to set the Vision Sensor’s communications specifications before registering the Master’s scan list. Refer to the Expert Menu Operation Manual for details on setting the Vision Sensor’s communications specifications and changing the I/O format.

40

Page 56

Z141-E1-03.book Page 41 Monday, July 24, 2006 5:16 PM

Section 5-1

Overview

Programmable Controller (Master)

Remote I/O communications See the diagram on the next page for details on the output and input areas.

F150-C10E-3-DRT

F150-C10E-3-DRT

F150-C10E-3-DRT

41

Page 57

Z141-E1-03.book Page 42 Monday, July 24, 2006 5:16 PM

Section 5-1

Overview Output Area

Write commands are directed to the F150 in this area. The number of bytes in the area depends upon the input mode (basic or expand) that is selected. Basic Word +0

Basic command (2 bytes)

Only a few words are occupied. Commands such as the measurement and scene change commands can be used.

Expand Word +0 Word +1 Word +2 Word +3 Word +4

42

Expand command (10 bytes)

A variety of commands other than the measurement command can be used, such as parameter setting and reading commands. Various F150's functions can be used.

Page 58

Z141-E1-03.book Page 43 Monday, July 24, 2006 5:16 PM

Section 5-1

Overview Input Area

The measurement results (execution results) from the F150 are output to this area. Word +0

Control output (2 bytes)

Word +1

Judgement results output (2 bytes)

Word +2

F150 status output (2 bytes)

Word +3 Word +4 Word +5

Expand command response output (10 bytes)

Word +6 These outputs can be enabled or disabled. When the “expand command response output” is disabled, the data output will be shifted up to word +3.

Word +7 Word +8 Word +9 Word +10 to

Data output (48 bytes)

Word +30 Word +31

43

Page 59

Z141-E1-03.book Page 44 Monday, July 24, 2006 5:16 PM

Section 5-2

Communications Specifications

5-2

Communications Specifications Item

Specification

Communications protocol

DeviceNet

Supported connections (see note 1) (communications)

Master-Slave: Remote I/O communications and explicit message/communications

Connection formats (see note 2)

Multi-drop and T-branch connections can be combined (for trunk or drop lines)

Baud rate

125K bps, 250K bps, or 500K bps (Set on the DIP switch.)

Communications media

Special 5-conductor cable (2 signal lines, 2 power lines, 1 shield)

Communications distances

500K bps

Network length: 100 m max. (see note 3) Drop line length: 6 m max. Total drop line length: 39 m max.

250K bps

Network length: 250 m max. (see note 3) Drop line length: 6 m max. Total drop line length: 78 m max.

125K bps

Network length: 500 m max. (see note 3) Drop line length: 6 m max. Total drop line length: 156 m max.

Communications power supply Node number Words used in Master (see note 4)

0 to 63 (Set on the DIP switch.) Output area

1 word (2 bytes) or 5 words (10 bytes) (Set to 1 word when shipped.)

Input area

3 words (6 bytes), 8 words (16 bytes), 27 words (54 bytes), or 32 words (64 bytes) (Set to 3 words when shipped.)

Error control checks

Note

44

Power supply voltage:11 to 25 VDC Current consumption:55 mA max.

CRC error check

1.

Only remote I/O communications are supported in the Vision Sensor’s Expert Menu. Explicit message communications are not supported.

2.

A terminator must be connected at each end of the trunk line.

3.

These values are valid when thick cable is used for the trunk line. The maximum network length is 100 m max. when thin cable is used.

4.

Set the number of words in the Menu. Reset the entire network after changing these settings.

Page 60

Z141-E1-03.book Page 45 Monday, July 24, 2006 5:16 PM

Section 5-3

DIP Switch Settings

5-3

DIP Switch Settings The node address and baud rate are set on the DIP switch. Be sure to turn OFF the power supply (including the communications power supply) before changing DIP switch settings.

Node address setting

Baud rate setting

Note Set the same baud rate on all nodes (Master and Slaves) in the network. If the F150 is not set to the correct baud rate, it will be unable to participate in the network and communications errors may occur in communications between nodes with correct node address settings. Node Address Setting (0 to 63) Set the node address in binary with pins 1 through 6. These pins have values of 1, 2, 4, 8, 16, and 32 (left to right). The node address is set to 0 when the Sensor is shipped. The following diagram shows the node address set to 10. The pins with values 2 and 8 are turned ON.

45

Page 61

Z141-E1-03.book Page 46 Monday, July 24, 2006 5:16 PM

Section 5-3

DIP Switch Settings

Baud Rate Setting (125K bps, 250K bps, or 500K bps) Pins 7 and 8 set the baud rate as shown in the following diagrams. • 125K bps (factory setting)

• 250K bps

• 500K bps

46