Page 62

Z141-E1-03.book Page 47 Monday, July 24, 2006 5:16 PM

Section 5-4

Connector Pin Allocation

5-4

Connector Pin Allocation

Shield

Name

Function

Color

V–

Power supply line (–)

CAN L

Communications data (Low)

Black Blue

Shield

Shield

---

CAN H

Communications data (High)

White

V+

Power supply line (+)

Red

Refer to the CompoBus/D (DeviceNet) Operation Manual for details on assembling a communications cable.

Note

1.

Turn OFF the power supply before connecting or disconnecting the cable. Peripheral devices may be damaged if the cable is connected or disconnected with the power ON.

2.

Securely tighten the connector screws.

47

Page 63

Z141-E1-03.book Page 48 Monday, July 24, 2006 5:16 PM

Section 5-5

LED Indicators

5-5

LED Indicators The status of CompoBus/D communications is indicated by the MS and NS indicators.

MS (Module Status) Indicator The MS indicator shows the status of node (F150) itself. The indicator will be lit green when the F150 is operating normally.

NS (Network Status) Indicator The NS indicator shows the status of network. The indicator will be lit green when the network is operating normally. Note The MS and NS indicators are lit in green or red. The status of these indicators (lit, flashing, or not lit) can be used to determine what error has occurred.

→ p. 58

5-6

Multi-vendor Applications Use the Vision Sensor’s specifications as well as the Device Protocol and Object Mounting information shown in the following tables when the F150-C10E-3-DRT is connected to another company’s Master.

Device Protocol General data Compatible DeviceNet Specifications Vendor name

OMRON Corporation, vendor ID = 47

Device type

Generic, protocol number = 0

Product code Network current consumption Physical conformance Connector type data Physical insulation

205 55 mA max. Open plug Yes

Supported indicators

Module, Network

MAC ID setting

DIP switch

Default MAC ID

0

Baud rate setting

DIP switch

Supported baud rates

125K bps, 250K bps, and 500K bps

Communicati Predefined Master/Slave connecons data tion set

48

Volume I - Release 2.0 Volume II - Release 2.0

Group 2 only server

Dynamic connection support (UCMM)

No

Explicit message fragmentation support

Yes

Page 64

Z141-E1-03.book Page 49 Monday, July 24, 2006 5:16 PM

Section 5-6

Multi-vendor Applications

Object Mounting Identity Object (0x01) Object class

Attribute

Not supported

Service

Not supported

Item Object instance

ID content

Attribute

Get (read)

Set (write)

1 Vendor

Yes

No

47

2 Product type

Yes

No

0

3 Product code

Yes

No

205

4 Revision

Yes

No

2.1

5 Status (bits supported)

Yes

No

Bit 0 and bit 10

6 Serial number

Yes

No

Unique for each Unit

7 Product name

Yes

No

F150-C10E-3

8 State

No

No

---

Item

DeviceNet service

Service

Object instance

Value

Parameter option

05 Reset

No

0E Get_Attribute_Single

No

Message Router Object (0x02) Object class Object instance

Attribute

Not supported

Service

Not supported

Attribute

Not supported

Service

Not supported

Vendor specification addition

No

DeviceNet Object (0x03) Item Object instance

Attribute

Item Object class

Service

ID content 1 Revision

Get (read)

Set (write)

Yes

No

02 (hexadecimal)

DeviceNet service 0E Get Attribute Single

Value

Parameter option No

49

Page 65

Z141-E1-03.book Page 50 Monday, July 24, 2006 5:16 PM

Section 5-6

Multi-vendor Applications Item Object instance

ID content

Attribute

Get (read)

Set (write)

1 MAC ID

Yes

No

2 Baud rate

Yes

No

---

3 BOI

Yes

No

00 (hexadecimal)

Yes

No

---

5 Allocation information

Yes

No

---

6 MAC ID switch changed

No

No

---

7 Baud rate switch changed

No

No

---

8 MAC ID switch value

No

No

---

9 Baud rate switch value

No

No

---

DeviceNet service

Service

---

4 Bus Off counter

Item Object instance

Value

Parameter option

0E Get_Attribute_Single

No

4B Allocate_Master/ Slave_Connection_Set

No

4C Release_Master/ Slave_Connection_Set

No

Assembly Object (0x04) Object class

Item

Attribute

Not supported

Service

Not supported

Section

Object instance 1

Information

Instance type

Item Object Attribute instance 1

Item Object instance 1

50

Service

Max. number of instances

Static I/O

1

Content

Get (read)

Set (write)

Value

1 Number of Members in List No

No

2 Members List

No

No

---

3 Data

Yes

Yes

---

DeviceNet service

---

Parameter option

0E Get_Attribute_Single

No

10 Set_Attribute_Single

No

Page 66

Z141-E1-03.book Page 51 Monday, July 24, 2006 5:16 PM

Section 5-6

Multi-vendor Applications Connection Object (0x05) Object class

Attribute

Not supported

Service

Not supported

Max. number of active connections

1

Item

Section

Object instance 1

Information

Max. number of instances

Instance type

Explicit Message

Production trigger

Cyclic

---

Transport type

Server

---

Transport class

3

---

Item Attribute Object instance 1

ID content

1

Get (read)

Set (write)

Value

1 State

Yes

No

---

2 Instance type

Yes

No

00 (hexadecimal)

3 Transport class trigger

Yes

No

83 (hexadecimal)

4 Produced connection ID

Yes

No

---

5 Consumed connection ID

Yes

No

---

6 Initial comm. characteristics

Yes

No

21 (hexadecimal)

7 Produced connection size

Yes

No

FE00 (hexadecimal)

8 Consumed connection size

Yes

No

FE00 (hexadecimal)

9 Expected packet rate

Yes

Yes

---

12 Watchdog time-out action

Yes

No

One of 01, 03

13 Produced connection path length

Yes

No

0000

14 Produced connection path

Yes

No

---

15 Consumed connection path length

Yes

No

0000

16 Consumed connection path

Yes

No

---

17 Production inhibit time

Yes

No

---

51

Page 67

Z141-E1-03.book Page 52 Monday, July 24, 2006 5:16 PM

Section 5-6

Multi-vendor Applications Item Object instance 1

DeviceNet service

Service

Item Object instance 2

52

No

0E Get_Attribute_Single

No

10 Set_Attribute_Single

No

Section Instance type

Information Polled I/O

Max. number of instances 1

Production trigger Cyclic

---

Transport type

Server

---

Transport class

2

---

Item Object instance 2

Parameter option

05 Reset

ID content

Attribute 1 State

Get Set (read) (write) Yes

No

Value ---

2 Instance type

Yes

No

01 (hexadecimal)

3 Transport class trigger

Yes

No

82 (hexadecimal)

4 Produced connection ID

Yes

No

---

5 Consumed connection ID

Yes

No

---

6 Initial comm. character- Yes istics

No

01 (hexadecimal)

7 Produced connection size

Yes

No

See note 1.

8 Consumed connection size

Yes

No

See note 2.

9 Expected packet rate

Yes

Yes

---

12 Watchdog time-out action

Yes

No

00

13 Produced connection path length

Yes

No

14 Produced connection path

Yes

0000 (no inputs) 0600 (with inputs)

No

No data (no inputs) 20_04_24_01_ 30_03 (with inputs)

15 Consumed connection Yes path length

No

16 Consumed connection Yes path

No

17 Production inhibit time Yes

No

0000 (no outputs) 0600 (with outputs) No data (no outputs) 20_04_24_01_ 30_03 (with outputs) 00

Page 68

Z141-E1-03.book Page 53 Monday, July 24, 2006 5:16 PM

Section 5-6

Multi-vendor Applications Note

1.

Indicates the number of input bytes used by the Slave. The leftmost and rightmost bytes are reversed. (For example, the produced connection size = 4000 when 64 bytes are used.)

2.

Indicates the number of output bytes used by the Slave. The leftmost and rightmost bytes are reversed. (For example, the consumed connection size = 4000 when 64 bytes are used.)

Item Object instance 2

DeviceNet service

Service

05 Reset

Parameter option No

0E Get_Attribute_Single

No

10 Set_Attribute_Single

No

Item

Section

Object instance 3

Instance type

Bit strobed I/O

Information

1

Max. number of instances

Production trigger

Cyclic

---

Transport type

Server

---

Transport class

2

---

53

Page 69

Z141-E1-03.book Page 54 Monday, July 24, 2006 5:16 PM

Section 5-6

Multi-vendor Applications

Item Object instance 3

ID content

Get (read)

Set (write)

Yes

No

---

2 Instance type

Yes

No

01 (hexadecimal)

3 Transport class trigger

Yes

No

82 (hexadecimal)

Attribute 1 State

Value

4 Produced connection ID

Yes

No

---

5 Consumed connection ID

Yes

No

---

6 Initial comm. characteristics

Yes

No

02 (hexadecimal)

7 Produced connection size

Yes

No

See note.

8 Consumed connection size

Yes

No

0800 (hexadecimal)

9 Expected packet rate

Yes

Yes

---

12 Watchdog time-out action

Yes

No

00

13 Produced connection path length

Yes

No

0600

14 Produced connection path

Yes

No

20_04_24_01_ 30_03

15 Consumed connection path length

Yes

No

0000

16 Consumed connection path

Yes

No

No data

17 Production inhibit time

Yes

No

00

Note Indicates the number of input bytes used by the Slave. The leftmost and rightmost bytes are reversed. (For example, the produced connection size = 0800 when 8 bytes are used.) With the bit-strobed interface, the maximum produced connection size is 8 bytes. A produced connection size of 8 bytes (0800) will be used if a higher value has been set for the number of input bytes with the user MPU; the set value will be used if it is 8 bytes or less.

Item Object instance 3

54

Service

DeviceNet service 05 Reset

Parameter option No

0E Get_Attribute_Single

No

10 Set_Attribute_Single

No