Page 38
Z141-E1-03.book Page 23 Monday, July 24, 2006 5:16 PM
Section 2-7
Lighting Extension Tube
Model
Maximum outer diameter
3Z4S-LE ML-EXR 30 dia.
Length Set of 7 tubes 0.5 mm, 1 mm, 2 mm, 5 mm, 10 mm, 20 mm, and 40 mm
Length: 40 mm
2-7
20 mm
10 mm
5 mm
2 mm 1 mm 0.5 mm
Lighting A stable image must be obtained to ensure accurate inspection. Use appropriate lighting for the application and the measurement object if using the F150-S1A Camera.
2-7-1
Lighting Methods
Back Lighting A stable, high-contrast image can be obtained using back lighting. Applications: Inspection of exterior shape or positioning inspection
Camera
Measurement object
Light source
23
Page 39
Z141-E1-03.book Page 24 Monday, July 24, 2006 5:16 PM
Section 2-7
Lighting Reflected Lighting
Ring Lights Light is shone uniformly on the measurement object. Applications: Surface inspections
Camera Light source
Measurement object
Oblique Lighting Detection can be made utilizing the difference in regular and diffuse reflected light. Applications: Inspections for surface gloss
Camera
Light source Measurement object
24
Page 40
Z141-E1-03.book Page 25 Monday, July 24, 2006 5:16 PM
Section 2-8
Two-camera Unit
Coaxial Lighting A stable image can be obtained with few shadows from uneven surfaces on the measurement object. Applications: Surface inspections, positioning, and hole inspections of comparatively small objects
Camera Light source
Half mirror Measurement object
2-8
Two-camera Unit By connecting the Two-camera Unit, two Cameras can be connected to one F150 and thus images can be taken from two Cameras at the same time.
2-8-1
Connecting to the Power Supply Use a 24-VDC power supply. Specifications of crimp terminals and cables are the same as those for the F150 Power Supply. → p. 14 Note If the F150 and the Two-camera Unit need to be started sequentially, turn ON the Two-camera Unit first and then turn ON the F150. If they are turned ON in the reverse order, image data may not be read correctly.
2-8-2
Connecting to the F150 Connect to the F150 using the F150-VA Camera Unit Cable provided with the Two-camera Unit.
25
Page 41
Z141-E1-03.book Page 26 Monday, July 24, 2006 5:16 PM
Section 2-8
Two-camera Unit
2-8-3
Connecting to Cameras Connect to the Cameras using F150-VS Camera Cables. + 24 VDC
F150-VS Camera Cable (3 m)
−
F150-VA Camera Unit Cable (15 cm) (Provided with Two-camera Unit)
F150-A20 Two-camera Unit
Connection to different types of Camera possible
26
Camera with Light Source F150-SL20A F150-SL50A Camera with Intelligent Light Source F150-SLC20 F150-SLC50 Camera Only F150-S1A
F150-C10E-3 F150-C15E-3 F150-C10E-3-DRT Controller
Page 42
Z141-E1-03.book Page 27 Monday, July 24, 2006 5:16 PM
Section 2-9
Mounting the Controller
2-9
Mounting the Controller The Vision Mate Controller can be mounted to DIN Track or a flat surface.
2-9-1
Mounting to DIN Track The Vision Mate Controller can be easily mounted to or removed from 35-mm DIN Track. DIN Track
PFP-M End Plate (OMRON)
The following DIN Tracks are available from OMRON. Model
Length
PFP-100N
1m
PFP-50N
50 cm
PFP-100N2
1m
Connecting to the Two-camera Unit Install the Two-camera Unit to the left of the F150 using the Camera Unit Cable (15 cm).
27
Page 43
Z141-E1-03.book Page 28 Monday, July 24, 2006 5:16 PM
Section 2-9
Mounting the Controller
Mounting the Controller Hook the Controller into the DIN Track as shown in the diagram and then press in at the bottom until the Controller locks into place.
Removing the Controller Use a screwdriver to pull the hook down and then pull out the Controller from the bottom.
2-9-2
Mounting on a Flat Surface Mount the Controller using the holes and dimensions shown in the following diagram. Four, M4
Unit: mm
100±0.2
120±0.2
28