Page 44

Z141-E1-03.book Page 29 Monday, July 24, 2006 5:16 PM

SECTION 3 Terminal Blocks This section describes how to connect the terminal blocks. The F150 can input measurement triggers and output measurement results through these terminal blocks. For details on setting communications specifications and I/O formats, refer to the relevant operation manuals.

3-1

Crimp Terminals and Cables . . . . . . . . . . . . . . . . . . . . . .

30

3-2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30

3-3

Terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

29

Page 45

Z141-E1-03.book Page 30 Monday, July 24, 2006 5:16 PM

Section 3-1

Crimp Terminals and Cables

3-1

Crimp Terminals and Cables The terminal block uses M3 terminal screws. Use appropriate crimp terminals for M3 screws, as shown below. Tighten the screws to a torque of between 0.5 and 0.6 N⋅m. Confirm that wiring and tightening have been done properly. Use a cable length not exceeding 30 m.

!Caution Cover the terminal blocks with the Terminal Block Protection Covers after wiring. Forked

Round

6.2 mm max.

6.2 mm max.

Applicable wire size: Insulated wire of 1.31 to 1.65 mm2 (AWG16 to AWG15)

3-2

Specifications !Caution Use a DC power supply with a safe extra low-voltage circuit that prevents occurrences of high voltages in the power supplies for the terminal blocks.

Input Specifications Item Input voltage

F150-C10E-3, F150-C10E-3-DRT (NPN model) 12 to 24 VDC ±10%

ON current

5 to 15 mA

ON voltage

8.8 V max.

OFF current

0.1 mA max.

OFF voltage

4.5 V min.

ON delay

RESET input:

10 ms max.

Others:

0.5 ms max.

RESET input:

15 ms max.

Others:

0.7 ms max.

OFF delay Internal circuits

30

F150-C15E-3 (PNP model)

COM IN

Input terminal

Input terminal

COM IN

Page 46

Z141-E1-03.book Page 31 Monday, July 24, 2006 5:16 PM

Section 3-3

Terminals Output Specifications Item

F150-C10E-3, F150-C10E-3-DRT (NPN model)

Output voltage

12 to 24 VDC ±10%

Load current

45 mA max.

ON residual voltage

2 V max.

OFF leakage current

0.1 mA max.

F150-C15E-3 (PNP model)

Internal circuits Output terminal COM OUT Load Load COM OUT

Output terminal

Note If UL recognition is required, use a UL class II power supply.

3-3

Terminals The terminals on the terminal blocks are assigned as shown in the following diagrams and tables.

F150-C10E-3 F150-C15E-3 Top terminals

Bottom terminals

31

Page 47

Z141-E1-03.book Page 32 Monday, July 24, 2006 5:16 PM

Section 3-3

Terminals Top Terminals *1

✕

✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕

✕ ✕

✕ ✕ ✕ ✕ ✕ ✕ ✕

Name/Application

✕ ✕ ✕

Name/Application

RUN

ERR

BUSY

GATE

OR COM OUT (*1)

For RUN, ERR, BUSY, GATE, and OR

DSA

Command inputs

Error output

NC

Not connected

RESET

Resets F150

STEP

DI 0

DI 1

DI 2

DI 3

DI 4

DI 5

DI 6

DI 7

COM IN

---

Command inputs

Bottom Terminals

✕ ✕

✕ ✕

✕ ✕

✕

✕

✕ ✕ *2

32

✕ ✕

✕ ✕

✕ ✕ ✕

✕ ✕ *3

Page 48

Z141-E1-03.book Page 33 Monday, July 24, 2006 5:16 PM

Section 3-3

Terminals

Name/Application DO 1

Measurement results output

DO 3 DO 5

Name/Application DO 0 DO 2

Measurement results output

DO 4

DO 7

DO 6

NC

Not connected COM OUT (*2)

For DO 0 to DO 7

DO 9

Measurement results output

Measurement results output

DO 11

DO 8 DO 10

DO 13

DO 12

DO 15

DO 14

---

COM OUT (*3)

For DO 8 to DO 15

!Caution Do not input the RESET input immediately after turning ON the power. When using RESET input to synchronize execution timing, wait at least 1 s after turning ON the F150 power supply before turning ON the RESET terminal.

!Caution Do not reverse the connections of the signal terminals and COM terminals.

F150-C10E-3-DRT

33

Page 49

Z141-E1-03.book Page 34 Monday, July 24, 2006 5:16 PM

Section 3-3

Terminals

Name/Application

Name/Application

RUN

ERR

BUSY

GATE

OR

NC

Not connected

RESET

Resets F150

COM OUT NC

Not connected

Error output

STEP

NC

NC

NC

NC

NC

NC

NC

NC

COM IN

---

Not connected

!Caution Do not input the RESET input immediately after turning ON the power. When using RESET input to synchronize execution timing, wait at least 1 s after turning ON the F150 power supply before turning ON the RESET terminal.

!Caution Do not reverse the connections of the signal terminals and COM terminals.

34