SYSMAC Transistor Remote Module G72C

Spec sheet9 pagesPDF 299 KB

Data sheet for the Omron SYSMAC G72C transistor remote modules, 16-point 24 VDC input (G72C-ID16) and output (G72C-OD16) terminals.

Download the PDF299 KB

Covers · 2 models

The models it covers

Summary

What is in it

The Omron data sheet for the SYSMAC G72C transistor remote modules, which combine a terminal block and transmission capability in one unit. It covers ordering information for the G72C-ID16, G72C-ID16-1, G72C-OD16 and G72C-OD16-1, input and output ratings, communication characteristics, nomenclature and indicators, DIP switch settings for word number, terminator and output hold/stop, system configuration with C200H-RM201 or C500-RM201 masters, dimensions, internal circuits, wiring and precautions.

Its parts

  1. Ordering Information
  2. Specifications
  3. Nomenclature
  4. Operation
  5. Dimensions
  6. Installation
  7. Precautions

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Omron spec sheet GC RIO-1 (04/00) for the G72C SYSMAC Transistor Remote Module, a 16-point 24 VDC remote terminal block made as the G72C-ID16 and G72C-ID16-1 for input and the G72C-OD16 and G72C-OD16-1 for output. It gives ratings, communication characteristics, switch settings, terminal wiring, dimensions and the rules for connecting it in an Omron Wired Remote I/O system.

Device
Remote terminal block with transmission built in: 16 I/O points per module, 24 VDC p. 1
Versions
Input: G72C-ID16 and G72C-ID16-1; output: G72C-OD16 (NPN, -- common) and G72C-OD16-1 (PNP, -- common) p. 1
Master modules
Omron Wired Remote I/O Master Modules C200H-RM201 and C500-RM201 p. 1, 5
Transmission
Two-conductor RS-485, half duplex, 187.5 kbps, 200 m total length; VCTF 0.75 x DPDT cable recommended p. 2
Power
24 VDC +10%/-15%; 200 mA max. with all 16 points on, 40 mA with all points off p. 2
ID16-1 inputs
G72C-ID16-1: 16 points (8 points/common), 24 VDC, 9.7 mA/point, ON 15 VDC max., OFF 5.6 VDC max., 1.5 ms delays p. 1
OD16-1 outputs
G72C-OD16-1: 16 points (8 points/common), 0.3 A/point, 1.2 V max. residual, 100 µA max. leakage p. 2
RUN output
SPST-NO contact, closed during operation; 100,000 operations at 2 A, 250 VAC p. 2
Network size
Up to 32 nodes per Remote I/O Subsystem; word number set from 31 downward (factory 31) p. 4, 8
Shared line
Shares transmission lines with G72C-V Remote Terminal Blocks and G71 Remote Interface with G7TC I/O Block nodes p. 1, 8
Label colors
G72C-ID16 red, G72C-OD16 yellow p. 8
Temperature
Operating 0°C to 55°C (32°F to 131°F); storage -20°C to 65°C (-4°F to 149°F) p. 2
Mounting, weight
DIN rail track or screw panel mounting; approx. 380 g p. 1, 2
Approvals
The sheet states UL recognized (File No. E41515) and CSA certified (File No. LD31928) for G72C-ID16, G72C-OD16 p. 2

What this sheet walks you through

  • Reading the POWER and T/R ERR indicators p. 3
  • Setting the terminator, word number and output HOLD/STOP mode p. 4
  • System configuration with a Wired Remote I/O Master Module p. 5
  • Internal circuits and terminal arrangement p. 6
  • Wiring two-wire and three-wire sensors and loads p. 7
  • Wiring the transmission line from the master without branching p. 8

Good to know

  • Set only one terminator per Remote I/O Master Unit, on the unit farthest from the master; it is factory-set to off. p. 4
  • Turn on all G71 and G72C units before powering the master. p. 8
  • Wire positive to positive and negative to negative, in order from the master, without branches. p. 8
  • Supply the correct power to each remote module and combine only compatible units. p. 8

Questions this sheet answers

Which PLC masters work with the Omron G72C?

The Omron Wired Remote I/O Master Modules C200H-RM201 and C500-RM201. p. 1

How far can a G72C remote terminal be from the master?

The transmission line can be 200 m in total length, at 187.5 kbps over two-conductor cable. p. 2

What do G72C outputs do on a transmission error?

In STOP mode (the factory setting) all output bits go off; in HOLD mode they keep their state. p. 4

How many G72C units can one master handle?

Each Remote I/O Subsystem on a Master Module can contain up to 32 nodes. p. 8

How much current does a G72C draw?

200 mA max. at 24 VDC with all 16 points on, and 40 mA with all points off. p. 2

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Front Page1
  2. Ordering Information1
  3. Specifications1
  4. Nomenclature3
  5. Operation4
  6. Dimensions5
  7. Installation6
  8. Precautions8
  9. Contacting Omron9

From the PDF’s own bookmarks.

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 91-9

The file

Revision and size

RevisionCat. No. GC RIO-1, 04/00
PublisherOmron Electronics, Inc.
Pages9
PDF299 KB
TextText from the PDF itself.

The first pages · 4 of 9

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 9
Page 2
Page 2of 9
Page 3
Page 3of 9
Page 4
Page 4of 9