Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 2 of 4

Cam Positioner H8PS, pages 9 to 16

Pages 9 to 16 of 32

The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron H8PS8B-F

Page 9

H8PS ■ Input Connections Only the Encoder inputs are connected with 8-output Models. The inputs are no-voltage (short-circuit or open) inputs.

No-voltage Inputs Contact Input

Open Collector

Voltage-output sensors can also be connected.

Connection Examples PLC, sensor, etc.

H8PS-16@ H8PS-32@

6

7

8

9

10

11

Note: Operates when the transistor turns ON.

H8PS-16@ H8PS-32@

6

7

8

9

10

Start

Origin

Bank 4

Bank 2

Bank 1

COM

Start

Origin

Bank 4

Bank 2

Bank 1

COM

Start

Origin

Bank 4

Bank 2

COM

Bank 1

Sensor, etc.

11

H8PS-16@ H8PS-32@

Note: Operates when the contact turns ON.

6

7

8

9

10

11

Note: Operates when the transistor turns ON.

No-voltage Input Signal Levels No-contact inputs

Short-circuit level for transistor ON • Residual voltage: 2 V max. • Impedance when ON: 1 kΩ max. (The leakage current is approx. 2 mA when the impedance is 0 Ω.) Open level for transistor OFF • Impedance when OFF: 100 kΩ min.

Contact inputs

Use a contact that can adequately switch 2 mA at 5 V.

Note: Use a maximum DC power supply of 30 V.

■ Output Connections Note: Internal circuit damage may result from a short circuit in the load.

NPN Output Models Outputs

PNP Output Models Vs (See note 2.)

Load

Outputs

(See note.)

Load COM/(−)

COM/(−) Note: 1. Always connect a diode to absorb counter-electromotive force when connecting an inductive load. 2. The VS terminal and power supply terminals are not connected internally.

Note: Always connect a diode to absorb counter-electromotive force when connecting an inductive load.

Item

Cam outputs, RUN output

(See note 1.)

Pulse output

Item

Cam outputs, RUN output

Pulse output

Output method

NPN open collector

Output method

PNP open collector

Dielectric strength

30 VDC

Dielectric strength

Rated current

100 mA (See note.)

30 mA

8-output Models: 30 VDC 16-/32-output Models: 26.4 VDC

Residual voltage

2 VDC max.

0.5 VDC max.

Rated current

100 mA (See note.)

Leakage current

100 μA max.

5 μA max.

Residual voltage

2 VDC max.

Leakage current

100 μA max.

Note: Do not exceed 1.6 A total for all cam outputs and the RUN output.

30 mA

Note: Do not exceed 1.6 A total for all cam outputs and the RUN output.

9

Page 10

H8PS

Operating Mode ■ Functions The H8PS Cam Positioner receives angle signal inputs from the Dedicated Absolute Encoder and outputs the preset ON/OFF angles as cam outputs.

Program Examples 1. H8PS-8@ (8-output Models) Cam output (cam number)

Step 0 ON angle

Step 1

OFF angle

ON angle

Step 9

OFF angle

ON angle

OFF angle

1

45°

90°

135°

225°

270°

315°

2

0°

90°

135°

180°

---

---

8

90°

225°

270°

285°

315°

345°

0°

45°

Cam output 1

90°

135°

180°

Step 0

Cam output 2

225°

270°

0°

45°

Step 9

Step 1

Step 0

315°

Step 1 Step 1

Cam output 8

Step 9

Step 0 (ON/OFF ratio 1:1)

Pulse output (See note 1.)

Note 1: The number of pulses per Encoder rotation and the pulse output start angle can be set. Note 2: With counterclockwise rotation (359°, 358° ...1°, 0°), step 0 for cam output 1 turns ON at 89° and OFF at 44° at in the diagram.

Outputs a preset number of pulses per Encoder rotation. (Default setting: 60 pulses/revolution)

RUN output ON during Run or Test Mode. OFF when an error occurs.

2. H8PS-16@ /-32@ (16-/32-output Models) Cam Program (Bank No. 7) Cam Program (Bank No. 2) Cam Program (Bank No. 1)

Cam Program (Bank No. 0) Cam output (cam number)

Step 0

Step 1

Step 9

ON angle

OFF angle

ON angle

OFF angle

ON angle

OFF angle

1

45°

90°

135°

225°

270°

315°

2

0°

90°

135°

180°

---

---

32

90°

225°

270°

285°

315°

345°

0°

Cam output 1

Cam output 2

45°

90°

Step 0

Step 0

135°

180°

225°

Step 1

270°

0°

45°

Step 9

Step 1 Step 1

Cam output 32

315°

Step 9

Step 0 (ON/OFF ratio 1:1)

Pulse output (See note 1.)

Outputs a preset number of pulses per Encoder rotation. (Default setting: 60 pulses/revolution)

RUN output ON during Run or Test Mode. OFF when an error occurs. Start input (See note 2.)

Note 1: The number of pulses per Encoder rotation and the pulse output start angle can be set. Note 2: Be sure to turn ON the start input in Run and Test modes. Otherwise, there will be no outputs (output prohibited), including the cam outputs, pulse output, and RUN output. Note 3: With counterclockwise rotation (359°, 358° ...1°, 0°), step 0 for cam output 1 turns ON at 89° and OFF at 44° in the diagram.

Note: The entire cam program can be changed at one time with 16- and 32-output Models with the bank function (banks 0 to 7). For details on the procedure for switching banks, refer to page 29.

10

Page 11

H8PS

Nomenclature ■ Displays 8-output Models

Display Details (8) All protect indication

(1) Cam output indicators (2) PV/SV indicator

1

2

3

4

5

6

7

8

PRG TST RUN

(9) Mode indicator

No. Display color (1)

Orange Lit while cam outputs are ON.

(2)

Red

(3)

Orange Lit while the start input is ON in Run or Test Mode. Not lit when an error occurs.

(4)

Orange Displays Encoder present angular position, direction, and speed guidelines.

(5)

Green

Displays the bank number that is running in Run or Test Mode and the bank number selected in Programming Mode.

(6)

Green

Displays the cam number for the angle setting displayed on subdisplay.

(7)

Green

Displays the step number for the angle setting displayed on subdisplay.

(10) Main display (11) Unit indication

(4) Rotation display monitor

(12) 256 indication (13) Unit indication (14) Sub-display CAM

(6) Cam No. display

(15) ON/OFF indication (16) ADV indication

STEP

(7) Step No. display

16-/32-output Models (8) All protect indication

(1) Cam output indicators (2) PV/SV indicator

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

(3) Start input indication (4) Rotation display monitor

PRG TST RUN

(11) Unit indication (13) Unit indication (14) Sub-display

(6) Cam No. display

Orange Lit while the All Protection function is enabled.

(9)

Orange The indicator for the selected mode is lit. PRG: Programming Mode TST: Test Mode RUN: Run Mode

(10) Red

Displays the present angular position or the speed and settings being made.

(11) Red

Displays units for the angle or the speed displayed on main display.

(12) Red

Lit while using an Encoder with a resolution of 256 if 256° display is selected.

(12) 256 indication

(5) Bank No. display STEP

CAM

(15) ON/OFF indication (16) ADV indication

(7) Step No. display

PV: Lit while the present angular position or speed is displayed in main display. SV: Lit while the setting value is displayed in main display.

(8)

(9) Mode indicator (10) Main display

Description

(13) Green

Displays units for the angle or the speed displayed on sub-display.

(14) Green

Displays the speed or the ON/OFF angle settings.

(15) Green

Indicates whether main display displays the ON or OFF angle setting.

(16) Green

Lit while setting the Advance Angle Compensation (ADV) Function.

■ Operation Keys 8-output Models

Operation Key Details No. CHECK

1. CHECK key CAM

2. CAM keys STEP

3. STEP keys 11. ADV key

STEP

CAM

12. Mode switch 13. Programming mode switch

PRGM TEST RUN

OFF

ANGLE

WRITE

6. WRITE key

CW 3

4

PLS/R

ANG DSPL

256 256 360 720

256 360 360 360

ON ON ON OFF OFF ON OFF OFF

ON OFF

CCW

Displays program details in Run Mode.

2

Selects the cam number with

Keys.

3

Selects the step number with

Keys.

4

Selects the bank number.

5

Selects the ON angle, or OFF angle

6

Writes the set data to memory.

7

Changes the angle or other setting value with

8

Connects the Cam Positioner to a personal computer via USB cable (order separately) for programming with the Support Software (order separately).

5. ON/OFF key

TCH MAN 1234

14. Rotation direction switch

ON

ADV

ORIGIN CLEAR

7. ANGLE keys

15. Encoder resolution switch

Moves to the screen for clearing settings

10

Designates the current angle of the machine (Encoder) as the origin (0°).

11

Programming or Test Mode: Press to shift to the ADV function setting screen. Programming Mode: Press and hold at least 3 s to shift to the Function Setting Mode. Run Mode: Press and hold at least 5 s to enable/disable the All Protection function.

12

Switches modes. Programming Mode (PRGM): Used to write cam programs, set the ADV function, etc. Test Mode (TEST): Used to modify settings while the Encoder is running. Run Mode (RUN): Used for normal operation and to check the cam program.

13

Select the method used for programming cams. Teaching: ON/OFF Angles can be set based on actual machine (Encoder) operation. Manual: ANGLE Keys can be used to set ON/OFF angles.

14

Sets the H8PS rotation direction (rotation display monitor, etc.) to the machine (Encoder) rotation direction.

15

Sets the resolution of the connected Encoder. Also sets the unit for angle display when using an Encoder with a resolution of 256.

10. ORIGIN key

16-/32-output Models CHECK

1. CHECK key CAM

2. CAM keys STEP

3. STEP keys 11. ADV key

CAM

STEP

12. Mode switch 13. Programming mode switch 14. Rotation direction switch 15. Encoder resolution switch

4. BANK key ADV

PRGM TEST RUN

BANK

ON

OFF

5. ON/OFF key

TCH ANGLE

MAN

WRITE

Keys.

9

9. CLEAR key

DO NOT USE.

Description

1

6. WRITE key

CW 1234 ON OFF

CCW

3

4

PLS/R

ANG DSPL

256 256 360 720

256 360 360 360

ON ON ON OFF OFF ON OFF OFF

DO NOT USE.

ORIGIN CLEAR

7. ANGLE keys 8. USB connector 9. CLEAR key 10. ORIGIN key

11

Page 12

H8PS

Dimensions Note: All units are in millimeters unless otherwise indicated.

■ Main Unit Cam Positioners Flush Mounting Models H8PS-8B@ (8-output Models)

Panel Cutout (according to DIN 43700)

15.2 21.6 M3.5 terminal screw

92 +0.8 0

(14.6) 96

52.9

12

92 +0.8 0

46

91.8 × 91.8

96

Note: Mounting panel thickness must be 1 to 5 mm. Flush mounting 14.6

(14.6)

H8PS-16B@ (16-output Models) H8PS-32B@ (32-output Models)

96

52.9 α

52.9 46

12

91.8 × 91.8

96

11 dia.

Mounting screws (2 included) (M4 x 12)

Mounting panel (1 to 5 mm)

Note: An 8-output Model is shown in the above diagrams. The Encoder is connected from the bottom with 16-/32-output Models.

M3.5 terminal screw 21.6 15.2

Surface Mounting Models

Terminal cover

Mounting bracket (included) 52.3 + α

Mounting holes

M3.5 terminal screw

H8PS-8BF@ (8-output Models)

81.8±0.2

(60.6) 58 46 22.9

96

115.2±0.3

91.8 × 91.8

96

121.2

16

90 (60.6) 58 46

H8PS-16BF@ (16-output Models) H8PS-32BF@ (32-output Models)

96

Four, M4 tap holes

Surface Mounting

Track Mounting

60.6

74.4 (See note 1.)

16

91.8 × 91.8

96

DIN Track

121.2 16

DIN Track Mounting Base Y92F-91 (Order Separately)

22.9

90

M3.5 terminal screw

16

Terminal cover

Note: 1. These dimensions vary with the kind of DIN track (reference value). 2. An 8-output Model is shown in the above diagrams. The Encoder is connected from the bottom with 16-/ 32-output Models.

12

Page 13

H8PS Encoder Connecting Direction H8PS-8B@

H8PS-8BF@

H8PS-16BF@ H8PS-32BF@

H8PS-16B@ H8PS-32B@ Encoder

Encoder

Output cable

Encoder

Output cable

Encoder

■ Accessories (Order Separately) Parallel Input Adapters

• Panel Surface Mounting Front

Y92C-30

M4 screw (included)

This Adapter enables two H8PS Cam Positioners to share signals from an Encoder. Note: H8PS has been improved in 2004 April. Do not mix old and new model with Y92C-30. When you use 2 x H8PS, please use by "Old & Old" or "New & New" models.

74±1

Two, M4 tap holes

36

• Panel Back Mounting Back M4 nut (included) M4 screw (included) Connected to the H8PS.

Connected to the H8PS.

74±1

Y92C-30

Two, 4.3 dia. holes

36

From the Dedicated Absolute Encoder

Use the cable marked with a triangle when connecting only one H8PS Cam Positioner to the Parallel Input Adapter. 9

47 40.4

1,030 6.5 15

37

8.5 dia. 17 dia. 89

60

26

24

R6.5

36 14 dia. 11.3

13

Page 14

H8PS ■ Accessories (Order Separately) Panel Cutout

Watertight Cover 21.9

Y92A-96N

Cover dimensions (2)

92 +0.8 0

CHECK

CAM

STEP CAM STEP

92 +0.8 0

131.7

69.3

Y92A-9 6N

Use for flush mounting when waterproofing is required. The Y96A-96N conforms to IP66 and 115.6 28.9 NEMA4 (for indoor use) standards for waterproofing. The operating environment may cause the waterproof packing to deteriorate, shrink, or harden. Therefore, it is recommended that the packing be replaced regularly.

DIN Track Mounting Base

Protective Cover

Y92F-91

Y92A-96B A hardened Y92A-96B Protective Cover is available. Use it for the following:

CHECK

CAM

• To protect the front panel from dust and dirt. • To prevents the set value from being altered due to accidental contact with the keys or switches.

STEP CAM STEP

Discrete Wire Output Cable

Connector-type Output Cable

Y92S-41-200

E5ZE-CBL200

Cable length: 2 m

Cable length: 2 m

Mounting Track PFP-100N PFP-50N

PFP-100N2

7.3±0.15

16

4.5 35±0.3

27±0.15

4.5 35±0.3 27

15

25

10

25

25

25

15 (5)*

24

29.2

1

10 1,000 (500)* * The numbers in parentheses () are dimensions for the PFP-50N.

End Plate

15

25

10

25

25 1,000

10

25

15

1

1.5

Spacer

PFP-M

PFP-S

10 6.2

50

M4 x 8 pan-head screw

16 12

5

1.8 34.8

1 35.5 35.3

44.3

1.8 11.5 10 M4 spring washer

1.3 4.8

16.5

14

Page 15

H8PS

E6CP-A/E6C3-A/E6F-A Rotary Encoders (Absolute) • Combining this Encoder with an H8PS Cam Positioner enables high-precision detection of the operation timing of various automatic machines. • The E6CP-A is a low-cost, money-saving Encoder. • The standard E6C3-A is well suited to environments subject to water and oil. • The standard E6F-A is a rigid type that is compatible with high shaft-tolerance applications as well as environments subject to water and oil. Note: Refer to the relevant datasheet for details.

Ratings and Characteristics Item

E6CP-AG5C-C

E6C3-AG5C-C

E6F-AG5C-C

Rated supply voltage 12 VDC −10% to 24 VDC +15%, ripple (p-p) 5% max. Current consumption 70 mA max. (See note 1.) Resolution (pulses per rotation)

256 (8-bit)

Output code

Gray binary

60 mA max. 256 (8-bit), 360 (9-bit), or 720 (10-bit)

Output configuration NPN open-collector output Output capacity

Applied voltage: 28 VDC max. Sink current: 16 mA max. Residual voltage:0.4 V max. (sink current at 16 mA)

Logic

Negative logic (H = 0, L = 1)

Accuracy

Within ±1°

Rotation direction

Clockwise (viewed from the shaft) for output code increment

Applied voltage: 30 VDC max. Sink current: 35 mA max. Residual voltage:0.4 V max. (sink current at 35 mA)

Rise and fall times of 1.0 μs max. (control output voltage: 16 V; load 1.0 μs max. (control output voltage: 5 V; load resistance: 1 kΩ; output cord: 2 m max.) output resistance: 1 kΩ; output cord: 2 m max.) Starting torque

0.98 m N·m max.

10 m N·m max. (at room temperature), 30 m N·m max. (at low temperature)

9.8 m N·m max. (at room temperature), 14.7 m N·m max. (at low temperature)

Moment of inertia

1 × 10−6 kg·m2 max.

2.3 × 10−6 kg·m2 max.

1.5 × 10−6 kg·m2 max.

Shaft-load tolerance

Radial

29.4 N

80 N

120 N

Thrust

19.6 N

50 N

1000 r/min

5000 r/min

Max. permissible rotation

Ambient temperature −10 to 55°C (with no icing) Storage temperature

−25 to 85°C (with no icing)

Ambient humidity

35% to 85% (with no condensation)

Degree of protection

IEC standard IP50

−10 to 70°C (with no icing) −25 to 80°C (with no icing) IEC standard IP65 (JEM standard IP65f) (See IEC standard IP65 (JEM standard IP65f) note 2.)

Insulation resistance 200 MΩ min. (at 500 VDC) between charged parts and the case Dielectric strength

500 VAC, 50/60 Hz for 1 min between charged parts and the case

Vibration resistance

Destruction: Destruction: Destruction: 10 to 55 Hz,1.5-mm double amplitude for 2 hr 10 to 500 Hz, 2-mm double amplitude, 150 m/ 10 to 500 Hz,1.5-mm double amplitude 3 each in X, Y, and Z directions s2 3 times each in X, Y, and Z directions, 11- times each in X, Y, and Z directions, 11-min sweep time min sweep time

Shock resistance

Destruction: 1000 m/s2 3 times each in X, Y, and Z directions

Weight

Approx. 200 g (with 2-m cord)

Approx. 300 g (with 1-m cord)

Approx. 500 g (with 2-m cord)

Datasheet Cat. No.

---

F058

E283

Note: 1. The following inrush currents flow when the power is turned ON. E6CP-AG5C-C: Approx. 8 A (time: approx. 0.3 ms), E6C3-AG5C-C: Approx. 6 A (time: approx. 0.8 ms), E6F-AG5C-C: Approx. 9 A (time: approx. 5 μs) 2. JEM1030: Applicable as of 1991

15

Page 16

H8PS

Dimensions Note: All units are in millimeters unless otherwise indicated. E6CP-AG5C-C

10 8 45°

50

5 3

45°

1 0 56 dia. 25 −0.2 dia.

50 dia. 6 −0.008 −0.020 dia.

Note: Order the E69-C06B Coupling separately.

Accessory Mounting Bracket (Included)

2,000

(See note 2.)

(See note 1.) 16.9 dia.

37

40

Panel

Bracket Mounting Diagram

2

5.5 dia. holes

Note 1: Round, vinyl-insulated cable with 10 cores (external dia.: 6, cross-sectional area: 0.18 mm2, insulation: 1.0 mm dia.), standard length: 2 m Note 2: Connector to the H8PS Cam Positioner.

38 dia.

Four, M4 holes (depth: 10)

120° 25 dia.

(18) 16 9

Two, C1

120°

120°

3.1+0.1 0

8 16

(5.1) 68±0.2 dia.

Three, M5

E6C3-AG5C-C

(58) (15) 10

120°±0.1

40±0.1 dia.

38

20

D cut: Phase-Z position (range: ±15°)

5 1

+0 8 −0.018 dia.

12 dia.

1

+0

30 −0.021 dia.

50 dia. Three, M4 holes (depth: 5) 6

120°±0.1

Note: Order the E69-C08B Coupling separately.

8.8

10

6

37

Oil-resistant, shield PVC-insulated cable with 12 cores (external dia.: 6, cross-sectional area: 0.2 mm2, insulation: 1.1 mm dia.), standard length: 1 m or 2 m

E6F-AG5C-C

(85) 60 20

Four, M3 holes (depth: 6)

3

15 24 dia.

5 3

48 dia.

54 dia. 0 60 dia. 40 −0.025 dia.

1

0 10 −0.015 dia.

Bearings

Note: Order the E69-C10B Coupling separately. 17

Note 1: Round, shielded vinyl-insulated cable with 12 cores (external dia.: 6, cross-sectional area: 0.2 mm2, insulation: 1.1 mm dia.), standard length: 2 m Note 2: Connector to the H8PS Cam Positioner

14 max. 42.5

(See note 1.)

16.9 dia.

2,000

Accessory Mounting Bracket (included) 5.5 dia. holes

Bracket Mounting Diagram

(See note 2.)

37

Panel

2

120°

(18) 16 9

40 dia. 120°

Two, C1

120°

3.1+0.1 0

8 16

(5.1) 72±0.2 dia.

Three, M5

16