Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 3 of 4

Cam Positioner H8PS, pages 17 to 24

Pages 17 to 24 of 32

The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Omron H8PS8B-F

Page 17

H8PS Accessories (Order Separately) E69-C06B Shaft Coupling (for the E6CP)

E69-C08B Shaft Coupling (for the E6C3)

2.8

(11) (16.4)

26.2

23.6

22 5.5

E69-C10B Shaft Coupling (for the E6F)

5.5

6.8

Four, M3 Hexagon 2.8 socket-head setscrews

6.8

3.5

8H8 dia.

6H8 dia.15 dia.

Note: The material is fiber-glass-reinforced polybutylene terephthalate resin (PBT).

7.1

Four, M4 Hexagon 3.5 socket-head setscrews

3.6

8H8 dia.19 dia.

34.6

5,000

7.1 3.6

Four, M4 Hexagon socket-head setscrews

10H8 dia.22 dia.

Note: The material is fiber-glass-reinforced polybutylene terephthalate resin (PBT).

Note: The material is fiber-glass-reinforced polybutylene terephthalate resin (PBT).

E69-DF5 Extension Cable

(12) (19)

37

16.9 dia.

16.9 dia. (See note 1.)

(See note 2.)

(See note 3.)

Note 1: E6F-AG5C-C, E6CP-AG5C-C, and E6C3-AG5C-C Connectors for the H8PS. Note 2: 6-dia., 12-core shielded cable (cross-sectional area: 0.2 mm2, insulation: 1.1 mm dia.), standard length: 5 m Note 3: Connected to the H8PS Cam Positioner.

Note: Refer to Characteristics on page 4 for the maximum cable length. The following models are also available: E69-DF10 (10 m), E69-DF15 (15 m), E69-DF20 (20 m), and E69-DF98 (98 m).

Safety Precautions for Encoders ■ Precautions for Correct Use • Do not subject the E6CP Encoder to oil or water. • The Encoder consists of high-precision components. Handle it with utmost care and do not drop it, otherwise malfunctioning may result. • When connecting the shaft of the Encoder with a chain timing belt or gear, connect the chain timing belt or gear with the shaft via a bearing or coupling as shown in the following diagram. Chain sprocket

Mounting Procedure 1

Insert the shaft into the Coupling.

2

Secure the Encoder.

Do not secure the Coupling and shaft with screws at this time.

Coupling Bearings

Rotary Encoder

Refer to the table for the maximum insertion lengths of the shaft into the Coupling.

• If the decentering or declination value exceeds the tolerance, an excessive load imposed on the shaft may damage or shorten the life of the Encoder. • Do not place excessive loads on the shaft if the shaft is connected to a gear. • The tightening torque must not exceed the value given in the table at the right when the Rotary Encoder is mounted with screws. • Do not pull wires with a force greater than 29.4 N while the Rotary Encoder is secured and wired.

3

Coupling

Maximum insertion length

E69-C06B

5.5 mm

E69-C08B

6.8 mm

E69-C10B

7.1 mm

Secure the Coupling.

Coupling

0.25 N·m

E69-C08B

0.44 N·m

E69-C10B

0.44 N·m

4

Connect the power and I/O lines.

5

Turn ON the power and check the outputs.

Rotary Encoder

Fastening plate

Tightening torque

E69-C06B

Be sure to turn OFF the Encoder before connecting the lines.

29.4 N max.

Cord

• Do not subject the shaft to shock. Therefore, do not strike the shaft or coupling with a hammer when inserting the shaft into the coupling. • Make sure there is no foreign matter in the Connector before connecting it to the Encoder.

17

Page 18

H8PS

Safety Precautions for Cam Positioners Refer to Safety Precautions for All Counters.

!CAUTION Tighten terminal screws to a torque of 0.80 N·m so that they do not become loose. Minor fires or malfunction may occasionally occur. For 16- and 32-output Models, leave the protective label attached to the H8PS when wiring. Removing the label before wiring may occasionally result in fire if foreign matter enters the Unit. Remove the label after the completion of wiring to ensure proper heat dissipation. Leaving the label attached may occasionally result in fire. Do not disassemble, modify, or repair the H8PS or touch any of the internal parts. Otherwise, minor electric shock, fire, or malfunction may occasionally occur. Do no allow metal fragments, lead wire scraps, or chips from processing during installation to fall inside the H8PS. Otherwise, minor electric shock, fire, or malfunction may occasionally occur. Do not touch the terminals when power is being supplied. For Surface-mounting H8PS, always connect the terminal cover for after completing wiring. Otherwise, minor injury due to electric shock may occasionally occur.

■ Precautions for Safe Use Observe the following items to ensure the safe use of this product.

Environmental Precautions • Store the H8PS within specified ratings. If the H8PS has been stored at temperatures −10°C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. • Use the H8PS within the specified ratings for operating temperature and humidity. • Do not operate the H8PS in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. • Do not use the H8PS in locations subject to vibrations or shock. Extended use in such locations may result in damage due to stress. • Do not use the H8PS in locations subject to excessive dust, corrosive gas, or direct sunlight. • Install the H8PS well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. • The H8PS is not waterproof or oil resistant. Do not use it in locations subject to water or oil. • The life expectancy of internal components may be reduced if the H8PS is mounted side-by-side. • Do not use organic solvents (such as paint thinner or benzine), strong alkaline, or strong acids because they will damage the external finish.

Usage Precautions • Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. • Pay careful attention to polarity to avoid wrong connections when wiring terminals. • Do not connect more than two crimp terminals to the same terminal. • Use the specified wires for wiring. Applicable Wires AWG24 to AWG18 (cross-sectional area of 0.208 to 0.832 mm2) Solid or twisted wires of copper • Do not connect loads that exceed the rated output current. The output elements may be destroyed, possibly resulting in shortcircuit or open-circuit faults. • Always connect a diode to protect against counterelectromotive force when using an inductive load. Counterelectromotive force may destroy output elements, possibly resulting in short-circuit or open-circuit faults. • Use the specified cables to connect outputs. • Do not install input lines in the same duct or conduit as power supply or other high-voltage lines. Doing so may result in malfunction due to noise. Separate the input lines from highvoltage lines. • Internal elements may be destroyed if a voltage outside the rated voltage is applied. • Maintain voltage fluctuations in the power supply within the specified range. • Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 s. If the power supply voltage is not reached quickly enough, the H8PS may malfunction or outputs may be unstable. • Do not turn OFF the power supply when changing or deleting settings. The contents of the EEPROM may be corrupted.

18

Page 19

H8PS ■ Precautions for Correct Use • A cam output will remain ON if the set angles for two steps overlap for the same cam number. Step 1: 120° ON → 170° OFF Step 2: 150° ON → 210° OFF ON OFF

120°

150° 170°

210°

• A step will produce no output if the ON and OFF angle for the step are the same. • The RUN output does not turn ON during programming. RUN/TEST Mode Switch PRGM RUN output

ON OFF

Note: The RUN output turns ON with the timing shown in the diagram, but it remains OFF when an error occurs. Thus, you can use the output as a timing signal during operation, including trial operation. • Input signals may be accepted, not accepted, or unstable for the following times when the power supply is turned ON or OFF. Set the system to allow leeway in the timing of input signals. Approx. 1 second is required from the time the power supply is turned ON until outputs are made. Refer to the Operation Manual (Cat. No. Z199) for information on other timing. Power supply

• Do not subject H8PS Connectors (outputs, Encoder) to more than 30 N of force. • Confirm the waveform of the power supply circuit and install a surge absorber. Surge or noise applied to the power supply may destroy internal elements or cause malfunctions. • Switch the power supply circuit with a device rated at 3.5 A or higher. • Inrush current of approximately 3.5 A will flow for a short period of time when the power supply is turned ON. The H8PS may not start if the capacity of the power supply is not sufficient. Be sure to use a power supply with sufficient capacity. • EEPROM is used as memory when the power is interrupted. The write life of the EEPROM is 100000 writes. The EEPROM is written when settings are changed or deleted or when the resolution is changed. • Make sure that all settings are appropriate for the application. Unexpected operation resulting in property damage or accidents may occur if the settings are not appropriate. • Connect all negative (−) terminals, COM terminals, and Vs terminals. • When using the Y92C-30 Parallel Input Adapter for parallel operation, do not connect more than two H8PS Cam Positioners to the same Encoder.

ON OFF 5 ms 0 to 1 s

0 to 1.3 s

Input status

Unstable

Accepted

Unstable Not accepted

• When using 16-/32-output Modules, the operation timing of the outputs will be as shown below in relation to the ON/OFF timing of the start input. Refer to Bank Functions (F7/F8/F9) on page 29 when switching banks. ON Start input OFF

Cam outputs RUN output

225 ms max. Output OFF

225 ms max. Output possible

Output OFF

Refer to the following manual for precautions in using the Cam Positioner and other information required for operation: H8PS Cam Positioner Operation Manual (Cat. No. Z199)

19

Page 20

H8PS

Operating Procedures ■ Flow of Operation Initial Settings Setting Resolution and Rotation Direction

The Encoder resolution and rotation direction is set on a DIP switch. ➾ For details on the setting methods, refer to page 21. The Encoder is mounted to the machine and the origin for operation is determined. ➾ For details on the setting methods, refer to page 21.

Setting the Origin

Advanced Parameters can be set in Function Setting Mode to perform more advanced operations. function ➾ For details, refer to page 26 Advanced Functions.

Setting Functions

Programming Cams (Programming Mode) Setting ON/OFF Angles

Setting the ADV Function

Checking Timing (Test Mode)

There are three methods that can be used to set or change ON/OFF angles (i.e., cam programming). • Using the ANGLE Keys (Manual Mode) • Actually turning the Encoder (Teaching Mode) • Setting from personal computer using Support Software (order separately) ➾ For details on the setting methods, refer to pages 22 to 23. Advanced Advance angle compensation (ADV) function can be set if required. function ➾ For details on the setting methods, refer to page 27.

The machine is operated and outputs are actually made to check the timing of operation. If the timing of operation is not correct, it can be changed. ➾ For details, refer to page 23. Operation is started. ➾ For details, refer to page 24.

Operation (Run Mode)

Checking ON/OFF Angle Settings

The ON/OFF angles that have been set can be checked. ➾ For details, refer to page 24. Deletes settings. There are two methods that can be used to delete settings. • Clearing all programs (deletes all programming) • Clearing individual steps, cams, and banks ➾ For details, refer to page 25.

Clearing Settings

■ Settings for Basic Functions Changing the Mode PRG TST RUN

Programming Mode

Programming Mode

PRG

Changed with the mode switch. PRG TST RUN

Test Mode

TST

Changed with the mode switch. PRG TST RUN

Run Mode

Used to write cam programs, set the advance angle compensation function, etc. All outputs will remain OFF.

Test Mode Used to write cam programs, set the advance angle compensation function, and perform other operations while actually turning ON outputs to confirm operation timing. This mode is also used to adjust settings during operation.

RUN

Run Mode Key 5 s min.

ADV

All Protection Disables all keys and switches. will light when the all protection function is enabled. ➾ Refer to page 24.

ON/OFF Key 1 s min.

Used for normal operation. Settings, such as writing cam programs and setting the advance angle compensation function, cannot be performed.

Switching the Angle and Speed Display Main Display: Angle Sub-display: Speed ↓↑ Main Display: Speed Sub-display: Angle ➾ Refer to page 24.

20

Page 21

H8PS Setting Resolution and Rotation Direction One of three resolutions can be selected for the Encoder connected to the H8PS: 256, 360, or 720. The resolution and display angle are set here.

Turn OFF the power supply.

Setting the Origin The origin of the Cam Positioner is set to match the origin of the machine (Encoder). The same origin is used for all banks. (The bank function is supported only for 16-/32-output models.) Example: Setting the Present Angular Position of 150° to 0°

Change the mode. Set the programming mode switch.

Set the display angle and the Encoder resolution. Open the front cover at the lower part of the H8PS and set pins 3 and 4 on the DIP switch.

4

ON ON ON OFF OFF ON OFF OFF

ON OFF

CCW

3

Resolution

Display angle

256 256 360 720

256 360 360 360

Set the programming mode switch to TCH.

Mode

Programming mode

PRG TST RUN

CW 1234

Set the mode switch to PRGM.

TCH MAN

(See note 2.)

Not used.

Set the machine to its origin. Turn the machine (Encoder) to the position of the desired origin (150° in this example).

Note 1: Default settings are shown in reverse type. Note 2: When using an Encoder with a resolution of 256, displaying 360° directly is not possible. The H8PS thus provides a convenient setting that enables converting the display and settings to 360° when using an Encoder with a resolution of 256. When using a 360° display, however, some angles will not be displayed.

PRG

Check the rotation direction of the machine (Encoder). Turn ON the power supply. Turn the Encoder in the actual direction of operation and confirm that the rotation display monitor turns clockwise. If the monitor turns counterclockwise, turn OFF the power supply and change pin 1 on the DIP switch to CCW.

CW (See note.)

Rotation Display Monitor

1234

4

ON ON ON OFF OFF ON OFF OFF

ON OFF

CCW

3

Resolution

Display angle

256 256 360 720

256 360 360 360

CAM

STEP

Specify the origin. Press the ORIGIN Key. (See note.) In approx. 1 s, the present angular position display will change to 0° and the previous display will return. PRG

Not used.

Note: Default setting. CAM

Connect the machine (Encoder) and turn ON the power supply.

STEP

Note: With 16-/32-output models, the origin input from the terminal block can be turned ON to specify the origin.

End End of preparations. Note: Changes to DIP switch settings are enabled when the power is turned ON.

21

Page 22

H8PS Setting ON/OFF Angles in Manual Mode ON/OFF angles can be set manually using the ANGLE Keys on the front of the Cam Positioner. Example: Setting Step 1 of Cam No. 2 to Turn ON at 28° and Turn OFF at 51°

Change the mode.

ON/OFF angles can be set based on actual machine (Encoder) operation. Example: Setting the ON/OFF Angles by Teaching Step 2 of Cam No. 3

Set the mode switch to PRGM.

Set the programming mode switch.

Change the mode.

Set the mode switch to PRGM.

Set the programming mode switch.

Set the programming mode switch to TCH.

Set the programming mode switch to MAN.

Mode

Programming mode

PRGM TEST RUN

Set the bank No.

Setting ON/OFF Angles in Teaching Mode

Mode

TCH MAN

Banks can be specified only for 16-/32-output models.

• Press the BANK Key to specify the bank number and then press the WRITE Key.

Set the cam and step No. • Press the CAM Keys • Press the STEP Keys

Programming mode

PRGM TEST RUN

Set the bank No.

TCH MAN

Banks can be specified only for 16-/32-output models.

• Press the BANK Key to specify the bank number and then press the WRITE Key.

Set the cam and step No. to specify cam No. 2. to specify step No. 1.

• Press the CAM Keys • Press the STEP Keys to specify cam No. 3. to specify step No. 2.

PRG

TST

CAM

STEP CAM

STEP

Set the ON angle. • Press the ON↑ ↓OFF Key to flash the "ON↑" . • Press the ANGLE Keys to set an angle of 28 and then press the WRITE Key. PRG

Set the ON angle. • Press the ON↑ ↓OFF Key to flash the "ON↑". • Turn the machine (Encoder) to the desired ON angle. (195° in this example) • Press the WRITE Key.

TST

CAM

STEP

Set the OFF angle.

CAM

• Press the ON↑ ↓OFF Key to flash the "↓OFF". • Press the ANGLE Keys to set an angle of 51 and then press the WRITE Key. PRG

STEP

Set the OFF angle. • Press the ON↑ ↓OFF Key to flash the "↓OFF" . • Turn the machine (Encoder) to the desired OFF angle. (278° in this example) • Press the WRITE Key.

TST

CAM

STEP

End Note: Pressing the or Key continually will automatically increment or decrement the value. Pressing the other key during automatic increment or decrement will increase the speed.

CAM

STEP

End

22

Page 23

H8PS Setting ON/OFF Angles Using Support Software With 16-/32-output models, programs can be uploaded or downloaded easily with the optional Support Software (H8PS-SOFTV1) by connecting a personal computer to the Cam Positioner using the USB cable (Recommended USB Cables: ELECOM CO.Ltd. U2C-MF20BK).

Checking Timing (Test Mode) Testing Operation Operation can be tested to check operation timing. • Set the mode switch to TEST. Mode

Support Software Functions • Writing cam programs • Setting functions • Editing, saving, and printing programs • Displaying and printing cam program operation charts • Simple simulations of programs Applicable OS: Windows 98, 2000, ME, or XP

PRGM TEST RUN

• Operate the Encoder and check the timing of operation. 1

2

7 TST

Refer to the user’s manual for the Support Software for details.

Present angular position

ON/OFF angle setting CAM

STEP

• If the timing is not correct, change the ON/OFF angle settings. The settings can be changed in Test Mode.

Note: 1. Outputs will turn ON and OFF in Test Mode. Confirm system safety before switching to Test Mode. 2. With 16-/32-output model, be sure to turn ON the start input. Outputs are not turned ON unless the start input is turned ON.

23

Page 24

H8PS Operation (Run Mode) Starting Operation

All Protection Function

• Set the mode switch to RUN to start operation.

The all protection function locks the H8PS in Run Mode and prohibits any changes to settings. It can be used to prevent incorrect or

Mode unauthorized operation. If the ADV Key is pressed for at least 5 s in

PRGM TEST RUN

1

2

7 RUN

Start input indication (See note.)

Present angular position

Speed (r/min)

All Protection Function Disabled (Normal Operation) 1

STEP

CAM

Run Mode, the All Protection indicator will light on the display and all keys and switches will be disabled. If the mode switch is changed to Programming or Test Mode while protection is enabled, the All Protection indicator will flash to indicate that settings cannot be changed. If a setting on the DIP switch is changed while protection is enabled, the All Protection indicator will flash when the power supply is turned ON to indicate that settings cannot be changed.

2

4

5

6 RUN

Note: For 16/32-output models, be sure that the start input is ON and that the start input indicator is lit. Outputs (including the cam, pulse, and run outputs) will not function if the start input is OFF. The 8-output models do not have a start input.

Switching the Angle and Speed Displays

STEP

CAM

• Press the ON↑ ↓OFF Key for at least 1 s in Run Mode to reverse the

Press the ADV Key for 5 s min.

display positions of the present angular position and speed (r/min) between main display and sub-display. 1

2

7

All Protection Function Enabled RUN

1

2

4

5

6

All protection indication RUN

Present angular position on main display

Speed (r/min) on sub-display

Press the ON↑ ↓OFF Key for 1 s min.

CAM

STEP

Checking ON/OFF Angle Settings 1

2

7 RUN

Speed (r/min) on main display

Present angular position on sub-display

• During Run Mode, the CAM Keys and STEP Keys can be used to check the ON/OFF angle settings for any step. Also, the CHECK Key can be pressed to check the ON/OFF angle settings in order for all steps starting from cam 1. If there is no key operation for 10 s or longer during the checking operation, the previous display will be resumed.

24