Spec sheet · Omron
Safety Sensor Muting Controller F3SP-U2P
Spec sheet8 pagesPDF 2.6 MB
Data sheet for the Omron F3SP-U2P Safety Sensor Muting Controller, which adds a muting function to up to two safety light curtains.
What this file really is
The old site listed this file as a spec sheet for the Omron s10. The file is named as an Omron S10 spec sheet, but it is the data sheet for the Omron F3SP-U2P Safety Sensor Muting Controller and does not mention an S10.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
A catalog data sheet for the Omron F3SP-U2P, a controller that temporarily disables safety light curtain functions while workpieces or pallets pass, using muting sensors to tell a workpiece from a person. It explains the muting function, muting sensor layouts and the muting lamp check, then gives ordering information, ratings and performance, connection examples for one or two light curtains, nomenclature, dimensions, DIP switch settings and the applicable safety standards.
Its parts
- Features
- Ordering Information
- Ratings and Performance
- Connection Examples
- Nomenclature
- Dimensions
- Safety Precautions
- Terms and Conditions of Sale
- Certain Precautions on Specifications and Use
- Contact Information
From the sheet · read page by page
Key facts from this sheet
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
OMRON catalog pages for the F3SP-U2P Safety Sensor Muting Controller; the document never names the s10 it is filed under. It gives ratings, connection examples, DIP switch settings and precautions for adding a muting function to one or two safety light curtains.
- Device
- F3SP-U2P controller that adds a muting function to safety sensors such as light curtains p. 1
- Light curtains
- 2 sets max.; OMRON F3SN, F3SH, F3SL and F3SS p. 3
- Power supply
- 24 VDC ±10% (ripple p-p 10% max.) p. 3
- Power consumption
- 8 W max. without Muting Lamps and sensors; 24 W max. total (self-resetting fuse rating) p. 3
- Outputs
- 2 NO contacts, 250 VAC, 2.5 A max. p. 3
- Inputs
- Test inputs NC contacts; reset inputs NO contacts; muting sensor inputs PNP transistor or NO contact, 4 sets max. p. 3
- Response time
- 30 ms max. p. 3
- Muting lamp
- Incandescent lamp, 24 VDC, 3 to 7 W; PS-24-Y B0568 (PATLITE), ASSC-24 (ARROW ELECTRONICS) or F39-A11 recommended p. 3
- Indicators
- Red/green output indicators, 4 green input indicators, 1-digit 7-segment status display p. 3
- Functions
- Auto or manual reset (interlock), muting and override, self-test and external test p. 3
- Muting time
- 60 s max. (factory setting) or infinite, set by DIP switch p. 6
- Operating temperature
- −10 to 50 °C; storage −30 to 70 °C p. 3
- Weight
- Approx. 870 g (packaged) p. 3
What this sheet walks you through
- How muting tells a passing workpiece from a person p. 1
- Installing two or four muting sensors per safety sensor p. 2
- Muting lamp output and burned-out bulb detection p. 2
- Wiring examples with one or two safety light curtains p. 4
- Front-panel indicators and status display p. 4
- Outline dimensions p. 5
- Setting the DIP switches for muting time and reset mode p. 6
- International standards that apply to muting control p. 6
Good to know
- A Muting Lamp is required even when the muting function is not used. p. 3
- Lamp fault detection does not work with an LED lamp; replacement bulbs must be incandescent. p. 3
- Two light curtains can exceed the 24 W rating; feed one of them 24 V from an external power supply. p. 4
- Both DIP switches must have the same setting, or code 8 (error) is displayed; do not change them during operation. p. 6
- The manual states that type 4 sensors such as F3SN-A, F3SH, F3SL or F3SS give Safety Category 4, and a type 2 sensor such as F3SN-B gives Category 2. p. 2
Questions this sheet answers
What is the OMRON F3SP-U2P?
A safety sensor muting controller that adds a muting function to up to two safety light curtains. p. 1
Which light curtains work with the F3SP-U2P?
OMRON F3SN, F3SH, F3SL and F3SS, up to 2 sets. p. 3
What muting lamp does the F3SP-U2P need?
An incandescent 24 VDC lamp of 3 to 7 W. Lamp fault detection does not work with an LED lamp. p. 3
What does code 8 mean on the F3SP-U2P status display?
An error shown when the two DIP switches are not set to the same setting. p. 6
How long can the F3SP-U2P keep muting on?
60 s max. at the factory setting; a DIP switch setting makes the maximum muting time infinite. p. 6
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file