The text of a spec sheet · part 1 of 1
Safety Sensor Muting Controller F3SP-U2P, pages 1 to 8
Pages 1 to 8 of 8
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Omron s10
Page 1
Safety Sensor Muting Controller
F3SP-U2P A Controller That Adds a Muting Function to Safety Sensor • Applicable safety category: 4 • Connects to up to two Safety Curtains. • Disconnection detection function for muting lamp output. Note: Be sure to read the “Safety Precautions” on page H-100.
Features Muting Muting temporarily disables safety functions when workpieces, conveyance pallets, or other items pass into the Safety Sensor detection zone. Note: Refer to the definition in international standard IEC61496-1 (JIS B9704-1), 3-1. Muting: A temporary automatic suspension of a safety function(s) by safety-related parts of the control system. Safe zone Muting Sensor B
Danger zone
Incident light
Reflector
Safe zone Muting Sensor B
Danger zone
No incident light
Reflector
Safe zone Muting Sensor B
Danger zone
Incident light
Reflector
Workpiece
Workpiece
Muting Sensor A Safety Light Curtain Reflector Incident light
F3SN, etc.
Safety functions: Enabled
Workpiece
Muting Sensor A Safety Light Curtain Reflector No incident light
F3SN, etc.
Safety functions: Disabled
Muting Sensor A Safety Light Curtain Incident light F3SN, etc.
Reflector
Safety functions: Enabled
F3SP-U2P
Note: The F3SP-U2P Muting Controller distinguishes between entry of a workpiece and a human using differences in the detection timing between Muting Sensors A and B. Adjust the installation locations and detection directions for Muting Sensors A and B so that the light for both sensors will not be blocked by the passing of a human.
Safety Application Controllers
Safety Sensor Muting Controller F3SP-U2P
H-95
Page 2
Connect Two Safety Sensors (Maximum)
Either Two or Four Muting Sensors per Safety Sensor
Using two Safety Sensors is ideal for line loading and unloading areas.
The sensors that determine the timing of muting to distinguish between workpieces and humans are the Muting Sensors. Either of the following two installation methods can be used. With the first method, they are installed so that the optical axes of two throughbeam or retro-reflective photoelectric sensors cross. With the other method, four through-beam or retro-reflective photoelectric sensors are installed and, in parallel with the safety sensors, proximity sensors or limit switches are installed, two each front and back. The muting sensor output must be a PNP transistor or NO contact output.
Exit control
D2 C2
S2
Dangerous area
Entry control
B2 A2
D1 C1
S1
B1 A1
A1, A2. B1, B2, C1, C2, D1, D2: Muting Sensors S1, S2: Safety Sensor (Light Curtain)
Muting Lamp Output It is essential to install a Muting Lamp to notify workers in the area when the muting function is in effect. The F3SP-U2P has a built-in diagnostic function with which errors such as burned out Muting Lamp bulbs are detected by means of the current to disable the muting function. Muting Lamp Test and reset buttons F3SP
Lamp cable Power supply cable Muting cable
Light Curtain
Receiver cable Emitter cable
Muting Sensors
Compliance with Safety Category 4 Safety Category 4 can be complied with by connecting to type 4 sensors, such as the F3SN-A, F3SH, F3SL, or F3SS. Connecting to a type 2 sensor, such as the F3SN-B, complies with Safety Category 2.
Complies with International Standards F3SP-U2P
EC Directive compliance has been certified by TÜV Product Service, an independent German certification body. (CE marking)For use in North America, the cUL Mark has been certified.
Safety Application Controllers
H-96
Safety Sensor Muting Controller F3SP-U2P
Page 3
Ordering Information Appearance
Model F3SP-U2P
Ratings and Performance (For details, refer to the Instruction Manual.) Item
Model
F3SP-U2P Up to Category 4.
Number of light curtains connected
2 sets max. (See note 1.)
Power supply voltage
24 VDC ±10% (ripple p-p 10% max.)
Current consumption
8 W max. (not including Muting Lamps and Sensors) (See note 2.)
Response time
30 ms max.
Connectable light curtains
OMRON F3SN, F3SH, F3SL, and F3SS
Outputs
2 NO contacts, 250 VAC, 2.5 A max,
Inputs
Test inputs: NC contacts Reset inputs: NO contacts Muting sensor inputs: PNP transistor or NO contact; 4 sets max.
Indicators/Displays
Output indicators (Red/green LED indicators): Lit red when output is OFF. Lit green when output is ON. Input indicators (4 green LED indicators): Lit green when 24 V is input. Status display (7-segment, 1 digit) Displays F3SP status.
Test functions
Self-test (After power ON and during operation) External test (by test input)
Safety-related functions
Auto-reset/manual reset (interlock) Muting function and override function
Applicable Muting Lamps
Incandescence lamp, 24 VDC, 3 to 7 W (See notes 1 and 2.)
Ambient temperature
During operation: −10 to 50 °C During storage: −30 to 70 °C (with no icing or condensation)
Ambient humidity
15% to 95% (with no condensation)
Degree of protection
IEC60529 standard IP20
Vibration resistance (malfunction)
10 to 55 Hz, 0.7-mm double amplitude, 20 sweeps each in X, Y and Z directions
Shock resistance (malfunction)
100 m/s2 1,000 times each in X, Y, and Z directions
Weight (packaged)
Approx. 870 g
Accessories
Instruction manual
F3SP-U2P
Safety category
2. A Muting Lamp is required even when the muting function is not used. The following are recommended. (The power consumption is 5 W for either one.) • PS-24-Y B0568: By PATLITE Corporation. (Incandescence electric bulbs must be used for replacements. Fault detection will not function if an LED lamp is used. • ASSC-24: By ARROW ELECTRONICS IND. Co., Ltd. • F39-A11 (Order Separately)
Safety Application Controllers
Note: 1. The total power consumption cannot exceed 24 W, which is the F3SP fuse (self-resetting) rating. • Light curtain • Muting lamp: 3 to 7 W • F3SP alone (without load current): 8 W
PS-24-Y B0568 (by PATLITE Corporation)
ASSC-24 (by ARROW ELECTRONICS IND. Co., Ltd.)
Safety Sensor Muting Controller F3SP-U2P
H-97
Page 4
Connection Examples (Complies with Category 4)
Muting Sensors
Muting Sensors
OUT GND Vcc OUT GND Vcc OUT GND Vcc OUT GND Vcc
Using Two Safety Light Curtains and Eight Muting Sensors
OUT GND Vcc OUT GND Vcc OUT GND Vcc OUT GND Vcc
Using One Safety Light Curtain and Two Muting Sensors
Test
0V
Safety Output 1
Reset
24 VDC
OUT GND Vcc
OUT GND Vcc
Test
0V
Reset
24 VDC
Muting Sensors
Safety Output 2
OUT RX 2
OUT RX 1 RX2 _
A
1
2
+24 V dc
GND
3
4
Output 2: White
TX1
+
_
TEST
OMRON Muting Controller
10 11 12 13OUT 114 15OUT 216 D
A MUTING SENSOR
C MUTING SENSOR
N.C.
N.C.
TX2
+
N.C.
_
N.C.
STATUS RX 1A
F3SP-U2P N.C.
RX1
+
RX 1B
RX 2A
A
RX 2B
OUT RX 2
OUT RX 1
_
+
B
RX2 _
A
B
RS-485 (B): Pink RS-485 (A): Gray
RS-485 (B): Pink RS-485 (A): Gray
0 V: Blue
Output 2: White
Shield
Reset: Yellow
0 V: Blue
Vs: Brown
Test: Green
Shield
Interlock: White
F3SN-A or F3SH-A modes: Auto-reset mode Auxiliary output: Dark-ON output mode
Emitter
9
8
MUTING LAMP
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
N.C.: Red
Output 1: Green
0 V: Blue
Relay monitor: Red
Vs: Brown
Auxiliary output: Yellow
Shield
Reset: Yellow
0 V: Blue
Vs: Brown
N.C.: Red
Test: Green
Shield
Interlock: White
RS-485 (A): Gray
7
B RESET
OUT
RS-485 (B): Pink
6
5
B
Output 1: Green
+
Vs: Brown
B
Auxiliary output: Yellow
A
Shield
_
Relay monitor: Red
RX1
+
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Reset: Yellow
N.C.
RX 2B
0 V: Blue
N.C.
RX 2A
Vs: Brown
_
RX 1B
Test: Green
+
Safety Output 2
STATUS
Shield
TX2
N.C.
Safety Output 1
N.C.
RX 1A
F3SP-U2P N.C.
_
C MUTING SENSOR
Interlock: White
TX1
+
D
A MUTING SENSOR
N.C.: Red
B
OUT
9
8
0 V: Blue
7
MUTING LAMP
Output 2: White
6
5 TEST
OMRON Muting Controller
Vs: Brown
4 RESET
Output 1: Green
3
Relay monitor: Red
2 GND
Auxiliary output: Yellow
1 +24 V dc
10 11 12 13OUT 114 15OUT 216
Receiver
F3SN-A or F3SH-A (See note.)
F3SN-A or F3SH-A modes: • Auto-reset mode. • Auxiliary output: Dark-ON output mode.
Emitter
Note: When an F3SN-B is connected, Category 2 is satisfied.
Receiver
Emitter
F3SN-A or F3SH-A (See note.)
Receiver
F3SN-A or F3SH-A (See note.)
When two Safety Light Curtains are connected, there is a possibility of exceeding the F3SP-U2P's rated power consumption of 24 W. As shown in the wiring diagram, provide 24 V directly from an external power supply to either of the Safety Light Curtains. F3SN-A or F3SH-A modes: • Auto-reset mode. • Auxiliary output: Dark-ON output mode. Note: When an F3SN-B is connected, Category 2 is satisfied.
Nomenclature Output indicator (2-color LED, green/red)
Status display (1 digit)
F3SP-U2P
Sensor 1 input indicators (green, 2 LEDs) Sensor 2 input indicators (green, 2 LEDs)
Safety Application Controllers
H-98
Safety Sensor Muting Controller F3SP-U2P
Page 5
Dimensions Note: All units are in millimeters unless otherwise indicated.
F3SP-U2P
120
150
75
F3SP-U2P Safety Application Controllers
Safety Sensor Muting Controller F3SP-U2P
H-99
Page 6
Safety Precautions !WARNING The Muting Controller temporarily disables Safety Sensor outputs. If it is installed or used incorrectly, not only can safety not be assured, but an extremely dangerous situation may result. • This catalog is simply a guide to selecting products. Before attempting to operate the product, carefully read and understand the information provided in the Instruction Manual. Consult with your OMRON representative if you are not provided an Instruction Manual. • Carefully consider the installation environment and the performance and functionality of the equipment before using the product. • Have a risk assessment carried out by qualified personnel before using the product. • The product is designed to be used in combination with special safety sensors. Do not use it in combination with other sensors that do not conform to applicable international standards.
■ Precautions for Correct Use Do not use the F3SP-U2P in atmospheres or environments that exceed product ratings.
DIP Switches
Remove cover using flat-blade screwdriver or similar device. Two DIP switches
SW2
SW1
ON
1 2 3 4
• EN954-1, ISO13849-1 Safety on machinery: Safety-related parts of control systems, Part 1: General principles for design, Section 5.9 Muting. • IEC61496-1 Safety of machinery: Electro-sensitive protective equipment, Part 1: General requirements and tests, Annex A, A.7 Muting. • EN 415-4: “Safety of packaging machines part 4. Palletizers and depalletizers” Annex A, A2.2 Muting • ANSI B11.19-1990 “for Machine Tools - Safeguarding When Referenced by the Other B11 Machine Tool Safety Standards Performance Criteria for the Design, Construction, Care, and Operation” 4.2.3 Presence-Sensing Devices: Electro-Optical and Radio Frequency (R.F.)
1 2 3 4
The following international standards apply when implementing muting control. Refer to these standards when constructing actual safety circuits, and make sure that requirements are satisfied.
The F3SP has two DIP switches that can be used to change operating modes. Set the DIP switches as shown in the following table.
ON
Applicable International Standards
Note: 1. Code 8 (error) will be displayed if both switches are not set to the same setting. 2. The two DIP switches are facing in opposite directions. No. Setting
Function
1
X
Not used.
2
OFF
Muting sensor AB controls Light Curtain 1, and Muting sensor CD controls Light Curtain 2. (factory setting)
ON
Prohibited.
OFF
Maximum muting time: 60 s (factory setting)
ON
Maximum muting time: Infinite
OFF
Manual reset mode
ON
Auto-reset mode (factory setting)
3 4
Note: To ensure system safety, do not change the settings on the DIP switches during F3SP operation.
F3SP-U2P Safety Application Controllers
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. F066-E1-01
H-100
In the interest of product improvement, specifications are subject to change without notice.
Safety Sensor Muting Controller F3SP-U2P
Page 7
Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://oeweb.omron.com or contact your Omron representative for published information. 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 16. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 17. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Companies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
2. 3.
4.
5.
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
Page 8
omrRON
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron.com/oei, under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON.
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg, IL 60173
847-843-7900
For US technical support or other inquiries:
800-556-6766 Cat.No. GC SAFETY-3 07/05
OMRON CANADA, INC. OMRON ON-LINE
885 Milner Avenue Global - http://www.omron.com Toronto, Ontario M1B 5V8 USA - http://www.omron.com/oei 416-286-6465 Canada - http://www.omron.ca
Specifications subject to change without notice Printed in USA