Switch mode Power Supply

S82J Compact and Economical Switch mode Power Supplies with Capacities Up to 600 W DIN Track Mounting Bracket Type Now Available • Power range from 10 W up to 600 W. • Output Voltages: 5 V, 12 V, 15 V, or 24 V. • Mounting bracket provided for mounting to control panels. • Maintenance-free up to 300 W due to natural ventilation. • Protection-ON alarm indicator shows valuable protection functions in action (300-/600-W models). • Conforms to EMC standards: EN50081-2 and EN50082-2. • With an external filter, achieves conformance to EN50081-1 for universal usage on EMI (300-/600-W models). • Finger protection terminal block to meet VDE0106/P100 • Class 2 approved 10-W, 25-W (except for 5-V output), and 50-W (only for 24-V output) models. • UL508 approved. All models can be used at full load in UL508A industrial control panel applications. • Approved by UL/CSA standards, EN60950, and EN50178 (VDE0160). • Six-language instruction manual provided. (English, French, German, Italian, Spanish, and Japanese)

S82J

Covered Type

Open-frame Type

<10 W to 150 W> • 100 to 240-VAC input • 100 or 200 VAC (selected automatically) (100-W 5-/12-/15-V output, 150-W models)

<10 W to 150 W> • 100 to 240-VAC input • 100 or 200 VAC (selected automatically) (100-W 5-/12-/15-V output, 150-W models)

Enclosure Type

<300/600 W> • 100 or 200 VAC (selectable)

Model Number Structure ■ Model Number Legend S82J 2

3

4

1. Power Ratings 010: 10 W 025: 25 W 050: 50 W 100: 100 W 150: 150 W 300: 300 W 600: 600 W 4. Mounting Bracket None: Front-mounting Bracket Type D: DIN Track Mounting Bracket Type

2. Output Voltage 05: 5V 12: 12 V 15: 15 V 24: 24 V

3. Configuration A: Open-frame type, front terminals B: Open-frame type, top terminals C: Open-frame type, connector D: Covered type, front terminals E: Covered type, top terminals F: Covered type, connector N: Without Mounting Bracket None: Enclosure type, front terminals with Mounting Bracket

Switch mode Power Supply S82J

Power Supplies

1

L-79

Page 2

Ordering Information ■ Front-mounting Bracket Type Configuration

Input Voltage

Power ratings

Open-frame type 100 to 240 VAC 10 W

Front terminals

Top terminals

Connector

2A

S82J-01005A

---

---

12 V

1A

S82J-01012A

---

---

15 V

0.7 A

S82J-01015A

---

---

24 V

0.5 A

S82J-01024A

---

---

5V

5A

S82J-02505A

---

---

12 V

2.1 A

S82J-02512A

---

---

15 V

1.7 A

S82J-02515A

---

---

24 V

1.1 A

S82J-02524A

---

---

5V

10 A

S82J-05005A

---

---

12 V

4.2 A

S82J-05012A

---

---

24 V

2.1 A

S82J-05024A

---

---

100 or 200 VAC 100 W (selected automatically)

5V

20 A

S82J-10005A

S82J-10005B

S82J-10005C

12 V

8.5 A

S82J-10012A

S82J-10012B

S82J-10012C

15 V

7A

S82J-10015A

S82J-10015B

S82J-10015C

100 to 240 VAC

24 V

4.5 A

S82J-10024A

---

---

100 or 200 VAC 150 W (selected automatically)

24 V

6.5 A

S82J-15024A

S82J-15024B

S82J-15024C

100 to 240 VAC 10 W

5V

2A

S82J-01005D

---

---

12 V

1A

S82J-01012D

---

---

15 V

0.7 A

S82J-01015D

---

---

24 V

0.5 A

S82J-01024D

---

---

5V

5A

S82J-02505D

---

---

12 V

2.1 A

S82J-02512D

---

---

15 V

1.7 A

S82J-02515D

---

---

24 V

1.1 A

S82J-02524D

---

---

5V

10 A

S82J-05005D

---

---

12 V

4.2 A

S82J-05012D

---

---

24 V

2.1 A

S82J-05024D

---

---

100 or 200 VAC 100 W (selected automatically)

5V

20 A

S82J-10005D

S82J-10005E

S82J-10005F

12 V

8.5 A

S82J-10012D

S82J-10012E

S82J-10012F

15 V

7A

S82J-10015D

S82J-10015E

S82J-10015F

100 to 240 VAC

24 V

4.5 A

S82J-10024D

---

---

100 or 200 VAC 150 W (selected automatically)

24 V

6.5 A

S82J-15024D

S82J-15024E

S82J-15024F

100 or 200 VAC 300 W (selectable)

24 V

14 A

S82J-30024

---

---

S82J-30024N

---

---

S82J-60024

---

---

S82J-60024N

---

---

50 W

25 W

50 W

600 W

L-80

Output current

5V

25 W

Covered type

Output voltage

Switch mode Power Supply S82J

27 A

Page 3

■ DIN Track Mounting Bracket Type Input Voltage

Power ratings

Open-frame type 100 to 240 VAC 10 W

Output current

Front terminals

Top terminals

Connector

5V

2A

S82J-01005AD

---

---

12 V

1A

S82J-01012AD

---

---

15 V

0.7 A

S82J-01015AD

---

---

24 V

0.5 A

S82J-01024AD

---

---

5V

5A

S82J-02505AD

---

---

12 V

2.1 A

S82J-02512AD

---

---

15 V

1.7 A

S82J-02515AD

---

---

24 V

1.1 A

S82J-02524AD

---

---

5V

10 A

S82J-05005AD

---

---

12 V

4.2 A

S82J-05012AD

---

---

24 V

2.1 A

S82J-05024AD

---

---

100 or 200 VAC 100 W (selected automatically)

5V

20 A

S82J-10005AD

S82J-10005BD

S82J-10005CD

12 V

8.5 A

S82J-10012AD

S82J-10012BD

S82J-10012CD

15 V

7A

S82J-10015AD

S82J-10015BD

S82J-10015CD

100 to 240 VAC

24 V

4.5 A

S82J-10024AD

---

---

100 or 200 VAC 150 W (selected automatically)

24 V

6.5 A

S82J-15024AD

S82J-15024BD

S82J-15024CD

100 to 240 VAC 10 W

5V

2A

S82J-01005DD

---

---

12 V

1A

S82J-01012DD

---

---

15 V

0.7 A

S82J-01015DD

---

---

25 W

50 W

Covered type

Output voltage

24 V

0.5 A

S82J-01024DD

---

---

5V

5A

S82J-02505DD

---

---

12 V

2.1 A

S82J-02512DD

---

---

15 V

1.7 A

S82J-02515DD

---

---

24 V

1.1 A

S82J-02524DD

---

---

5V

10 A

S82J-05005DD

---

---

12 V

4.2 A

S82J-05012DD

---

---

24 V

2.1 A

S82J-05024DD

---

---

100 or 200 VAC 100 W (selected automatically)

5V

20 A

S82J-10005DD

S82J-10005ED

S82J-10005FD

12 V

8.5 A

S82J-10012DD

S82J-10012ED

S82J-10012FD

15 V

7A

S82J-10015DD

S82J-10015ED

S82J-10015FD

100 to 240 VAC

24 V

4.5 A

S82J-10024DD

---

---

100 or 200 VAC 150 W (selected automatically)

24 V

6.5 A

S82J-15024DD

S82J-15024ED

S82J-15024FD

25 W

50 W

Power Supplies

Configuration

Switch mode Power Supply S82J

L-81

Page 4 read from a scan by OCR; it may hold reading errors

omrRONn

L-82 Switch mode Power Supply S82J

Page 5

Specifications ■ Ratings/Characteristics Item

100 to 240 VAC input 10 W

25 W

50 W

100 or 200 VAC (selected automatically) 100 W (24 V)

100 W (5, 12, 15 V)

150 W

Efficiency (typical)

67% min. (77% min. for 50-W, 24- 83% min. V models)

75% min.

Input

100 to 240 VAC (85 to 264 VAC) 110 to 170 VDC (set the terminal (L) to + side) (10 and 25 W only) (See note 1.)

100 (85 to 132) or 200 (170 to 264) VAC (selected automatically)

Voltage

300 W

600 W

82% min. 100 (85 to 132) or 200 (170 to 253) VAC (selectable)

50/60 Hz (47 to 450 Hz)

Frequency

Output (See note 3.)

100 or 200 VAC (selectable)

Current (See note 2.)

100 VAC input

0.35 A max.

0.8 A max. 1.4 A max. 2.5 A max.

2.5 A max.

3.5 A max. 8 A max.

14 A max.

200 VAC input

0.3 A max. 0.6 A max. 0.8 A max. 1.5 A max.

1.4 A max.

2.1 A max. 4 A max.

7 A max.

Leakage current (See note 2.)

100 VAC input

0.5 mA max.

200 VAC input

1 mA max.

Inrush current (25°C, cold start) (See note 2.)

100 VAC input

25 A max.

30 A max.

200 VAC input

50 A max.

60 A max.

Noise filter

Yes

Voltage adjustment range

±10% (adjustable with variable resistor (V. ADJ))

Ripple (See note 2.)

2% (p-p) max.

Input variation influence

0.4% max.

Load variation influence

0.8% max. (with rated input, 10% to 100% load)

Temperature variation influence

0.05%/°C max. (with rated input and output)

Startup time

500 ms max. (up to 90% of output voltage at rated input and output)

300 ms max. (up to 90% of output voltage at rated input and output)

Hold time (See note 2.) 20 ms min. Overload protection

105% to 160% of rated load current, inverted L drop/intermittent operation type, automatic reset

No Overvoltage protection (See note 5.)

Overheat protection

No

Protection-ON alarm indicator

No

Parallel operation

No

Series operation

No

Yes (See note 5.)

105% min. of rated load current, inverted L drop type, automatic reset (For the 600-W model, the circuit will be shut OFF when the overload exceeds 5 ±3 s. Protection-ON alarm indicator lit (See note 4.)) Yes (5-V out- No put models only) (See note 5.)

Yes, protection-ON alarm indicator lit (See note 4.)

Yes, protectionON alarm indicator lit (See note 4.) Yes (color, red) Yes, 5 units max. Yes Power Supplies

Additional function

Switching Power Supply S82J

L-83

Page 6

Item

100 to 240 VAC input 10 W

Other

25 W

50 W

100 or 200 VAC (selected automatically) 100 W (24 V)

100 W (5, 12, 15 V)

Ambient temperature

Operating: See the derating curve in the Engineering Data section. −25 to 65°C (with no condensation and icing) Storage:

Ambient humidity

Operating: 25% to 85% Storage: 25% to 90%

Dielectric strength

3.0 kVAC, 50/60 Hz for 1 min (between all inputs and all outputs)

150 W

100 or 200 VAC (selectable) 300 W

600 W

2.2 kVAC, 50/60 Hz for 1 min (between all inputs and GR terminal) 1.0 kVAC, 50/60 Hz for 1 min (between all outputs and GR terminal) Insulation resistance

100 MΩ min. (between all outputs and all inputs/GR terminals at 500 VDC)

Vibration resistance

10 to 55 Hz, 0.375-mm double amplitude for 2 h each in X, Y, and Z directions

Shock resistance

300 m/s2, 3 times each in ±X, ±Y, and ±Z directions

Terminal screw tightening

0.74 N·m

Output indicator

Yes (green)

Electromagnetic interference (See note 2.)

Conforms to FCC Class A

EMC

Emission Enclosure: Emission AC Mains: Immunity ESD:

EMC standards

Conforms to EN50081-2 and EN50082-2

Approved standards

UL

UL508 (Listing), 1950, Class 2 (per UL1310) (See note 10.)

UL508 (Listing), 1012, 1950 (See note 8.) UL508/1012

CSA

CSA C22.2 No. 14, No. 950, Class 2 (See note 10.)

CSA C22.2 No. 14, No. 950

VDE

EN50178 (VDE0160) and EN60950 Terminal types (only terminal part): VDE0106/P100

EN55011 class A EN55011 class A EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: ENV50140: 10 Vm (80 MHz to 1 GHz) (level 3) Immunity Conducted Disturbance: ENV50141: 10 V (0.5 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 2 kV output line (level 4)

250 g max.

Weight (See note 9.) Note: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10.

1.08 N·m

350 g max.

400 g max.

500 g max.

Conforms to EN50081-2 and EN50082-2 (See note 6.) With noise filter, confirms to EN50081-1 (See note 6 and 7.)

1,000 g max.

CSA EB1402C

2,000 g max.

2,500 g max.

DC inputs not included in safety standard approvals. At 100% load for rated input voltage (100 VAC or 200 VAC). The output specification is defined at the power supply output terminals. For resetting, turn OFF the power supply, leave for more than three minutes (90 seconds min. for the 300-W models), and then turn ON the power supply. For resetting, turn OFF the power supply, leave for more than one minute, and then turn ON the power supply. To ensure the Emission Enclosure rating ferrite ring cores (recommended model: S82Y-JC-T) should be used on all cabling. To ensure the Emission AC Mains rating for EN50081-1 (only for 200-VAC input), a noise filter (recommended models: S82Y-JF3-N for 300-W, S82Y-JF6-N for 600-W) should be used on the input lines. With UL508, 150-W connector type has “Recognized” approval. The weight indicated is the weight of the open-frame type. (Includes the covers for 300-W and 600-W models) Class 2 approved for 10-W, 25-W (except for 5-V output), and 50-W (only for 24-V output) models.

■ Reference Value Value

Definition

Reliability (MTBF)

Item

135,000 hours min.

MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product.

Life expectancy

10 yrs. min.

The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the builtin aluminum electrolytic capacitor.

L-84

Switching Power Supply S82J

Page 7

Connections ■ Block Diagrams S82J-010@@@@ (10 W) S82J-025@@@@ (25 W) Fuse*

Smoothing circuit

Rectifier

+V

AC (L)

Input

Noise Noisefilter filter

DC Output −V

AC (N)

Inrush current protection circuit

Rectifier and smoothing circuit

* Fuse capacity: 10 W, 1 A 25 W, 2 A Control circuit

Overload detection circuit

Detector Photocoupler

S82J-050@@@@ (50 W) Fuse*

AC(L) Input

+V DC Output

Noise filter

AC(N) Rectifier

Inrush current Smoothing protection circuit circuit

Rectifier and smoothing circuit

−V

* Fuse capacity: 3 A

Control circuit

Overload detection circuit

Detector Photocoupler

S82J-100@@@@ (100 W, 5-/12-/15-V Output) Fuse* +V

AC (L)

Noise Noisefilter filter

DC Output −V

AC (N)

* Fuse capacity: 5 A

100 or 200 V Rectifier and Inrush current protection circuit (selected auto- smoothing matically) circuit

Rectifier and smoothing circuit

Control circuit Detector

Overload detection circuit

Photocoupler

Power Supplies

Input

Overvoltage detector

Overvoltage protection circuit (5 V only)

Switching Power Supply S82J

L-85

Page 8

S82J-10024@@ (100 W, 24-V Output) AC(L)

Fuse (5 A)

+V

Input

DC Output

Noise filter −V

AC(N) Rectifier

Inrush current Smoothing protection circuit circuit

Rectifier and smoothing circuit

Control circuit

Overload detection circuit

Detector Photocoupler Overload detection circuit Photocoupler

S82J-15024@@ (150 W) AC (L)

Fuse (8 A)

Input

+V DC Output

Noise filter

AC (N) Inrush current protection circuit

−V

Rectifier and smoothing circuit

Rectifier

100 or 200 V (selected automatically)

Control circuit

Detector

Overcurrent detector

Photocoupler

S82J-30024@ (300 W) Rectifier and smoothing circuit

Fuse (10 A) Input

DC Output

Noise filter Inrush current protection circuit

Rectifier and smoothing circuit

100/200 V (selectable) Control circuit

Overcurrent detector

Detector Photocoupler

Overvoltage detector Photocoupler Parallel operation selector

L-86

Switching Power Supply S82J

Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 230 VAC.

Page 9

S82J-60024@ (600 W) Fuse 20 A

Rectifier and smoothing circuit

Input

Noise filter

DC Output Inrush current protection circuit

Rectifier and smoothing circuit

100/200 V (selectable) Fan

Control circuit

Overcurrent detector

Detector Photocoupler

Overheat detector

Overvoltage detector Photocoupler

Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 to 230 VAC.

Parallel operation selector

■ Installation 10-/25-/50-/100-/150-W Models Note: 10-/25-/50-/100 (24 V)-W models are available only as Front Terminal Models.

Front Terminals Model

Top Terminals Model

Connector Model

5

5

5

6

6

6 +V

1

+V

+V 1 −V

−V 3

GR

1

3

AC (L)

GR 3

GR

2

AC (L) NC AC (N)

AC (L) 2

2 AC (N)

−V

AC (N) 9

Types of Connector for the Connector Model (Housing and Terminal Not Included) Connector

Connector on the PCB side

Housing

Terminal

Input

Wafer (Made by Molex) 5277-04A-RE

Housing (Made by Molex) 5196-04-RE or Terminal (Made by Molex) 5194T or 5196-04 5194TL

Output

Tab header (Made by Nippon AMP) 1-178140-5

Rise housing (Made by Nippon AMP) 1-178129-6

Rise contact (Made by Nippon AMP) 1-175196-5 or 1-175218-5

Power Supplies

Note: The permissible current of the output connector is 8 A per pin.

Switching Power Supply S82J

L-87

Page 10

300-W Models 5 6 1

Side view

+V +V −V −V

AC (L) AC (N)

2 4

GR

3

7 8

600-W Models 65 7

1 −V −V +V +V

Side view

8

AC (L) AC (N) GR

1. DC Output Terminals: Connect the load lines to these terminals. 2. Input Terminals: Connect the input lines to these terminals. 4 3 2 Note: A fuse is inserted into the AC (L) side. 3. Ground Terminal (GR): Connect a ground line to this terminal. 4. Input Voltage Selector Terminals: Short-circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 230 VAC 5. Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON. 6. Output Voltage Adjuster (V.ADJ): It is possible to increase or decrease the output voltage by 10%. 7. Protection-ON Alarm Indicator: The red indicator will be lit if the overvoltage (for a 300-/600-W model) or overheat protection (for a 600-W model) circuit is triggered. This indicator will also be lit when overcurrent (for a 600-W model) is detected. 8. Parallel/Single Operation Selector: Set the selector to PARALLEL if the Units are in parallel operation. 9. NC Terminals: Leave unconnected.

L-88

Switching Power Supply S82J